Products and systems for the protection and repair of concrete structures - Test methods - Part 3: Determination of the adhesion of injection products, with or without thermal cycling - Slant shear method

This Part of this European Standard describes the method for determining the slant shear bond strength of all injection products intended to restore the integrity of cracked concrete and covered by prEN 1504-5.
The test may be performed upon cracks injected in the dry, damp, wet or with water flowing through them. It should always be carried out after the appropriate period of curing under the standard conditions of test detailed below, but may additionally be performed upon a further set of specimens after a period of artificial ageing by thermal cycling.
Whilst the testing of the repaired crack is normally by short term static load, it may also be performed as a creep test by long term static load, or as a dynamic test by the application of a cyclic load.

Produkte und Systeme für den Schutz und die Instandsetzung von Betontragwerken - Prüfverfahren - Teil 3: Bestimmung der Haftzugfestigkeit von Rissfüllstoffen mit oder ohne thermische Behandlung - Schrägscherfestigkeit

Dieses Dokument beschreibt ein Verfahren für die Bestimmung der Schrägscherfestigkeit von Rissfüllstoffen, die für das Wiederherstellen von gerissenem Beton vorgesehen sind und in prEN 1504 5 behandelt werden.
Die Prüfung kann auf Risse angewendet werden, bei denen die Injektion in trockene, feuchte, nasse oder wasserführende Risse erfolgt. Die Prüfung sollte immer nach der entsprechenden Aushärtedauer unter den nachfolgend beschriebenen, genormten Prüfbedingungen erfolgen, kann jedoch zusätzlich an einer weiteren Reihe von Prüfkörpern nach einer künstlichen Alterung durch thermische Behandlung durchgeführt werden.
Während die Prüfung eines instandgesetzten Risses üblicherweise mit kurzzeitiger statischer Belastung durchgeführt wird, kann sie auch als Kriechtest mit einer langzeitigen statischen Belastung oder als dynamische Prüfung durch eine zyklische Beanspruchung durchgeführt werden.

Produits et systemes pour la protection et la réparation des structures en béton - Méthodes d'essais - Partie 3: Détermination de l'adhérence des produits d'injection, apres cycles thermiques ou non - Méthode par cisaillement oblique

Le présent document décrit la méthode permettant de déterminer l'adhérence par cisaillement oblique de tous les produits d'injection destinés a rétablir l'intégrité d'un béton fissuré et couverts par le prEN 1504-5.
L'essai peut etre effectué sur des fissures injectées a l'état sec, humide, mouillé ou avec écoulement d'eau. Il convient de toujours l'effectuer apres la période de conservation appropriée, dans les conditions normalisées d'essai détaillées ci-apres, mais il peut également etre effectué sur un autre ensemble d'éprouvettes apres une période de vieillissement artificiel par cycles thermiques.
Bien que l'essai sur la fissure réparée soit normalement un essai sous charge statique a court terme, il peut également etre effectué sous forme d'un essai de fluage sous charge statique a long terme ou d'un essai dynamique sous l'application d'une charge cyclique.

Proizvodi in sistemi za zaščito in popravilo betonskih konstrukcij – Preskusne metode – 3. del: Določevanje sprijemnosti injekcijske mase s cikličnim spreminjanjem temperature ali brez njega – Metoda poševnega striga

General Information

Status
Published
Publication Date
30-Nov-2004
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2004
Due Date
01-Dec-2004
Completion Date
01-Dec-2004

Buy Standard

Standard
EN 12618-3:2004
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.LþQLPDProdukte und Systeme für den Schutz und die Instandsetzung von Betontragwerken - Prüfverfahren - Teil 3: Bestimmung der Haftzugfestigkeit von Rissfüllstoffen mit oder ohne thermische Behandlung - SchrägscherfestigkeitProduits et systemes pour la protection et la réparation des structures en béton - Méthodes d'essais - Partie 3: Détermination de l'adhérence des produits d'injection, apres cycles thermiques ou non - Méthode par cisaillement obliqueProducts and systems for the protection and repair of concrete structures - Test methods - Part 3: Determination of the adhesion of injection products, with or without thermal cycling - Slant shear method91.080.40Betonske konstrukcijeConcrete structuresICS:Ta slovenski standard je istoveten z:EN 12618-3:2004SIST EN 12618-3:2004en01-december-2004SIST EN 12618-3:2004SLOVENSKI
STANDARD



SIST EN 12618-3:2004



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12618-3August 2004ICS 91.080.40English versionProducts and systems for the protection and repair of concretestructures - Test methods - Part 3: Determination of theadhesion of injection products, with or without thermal cycling -Slant shear methodProduits et systèmes pour la protection et la réparation desstructures en béton - Méthodes d'essai - Partie 3:Détermination de l'adhérence des produits d'injection,après cycles thermiques ou non - Méthode par cisaillementobliqueProdukte und Systeme für den Schutz und dieInstandsetzung von Betontragwerken - Prüfverfahren - Teil3: Bestimmung der Haftzugfestigkeit von Rissfüllstoffen mitoder ohne thermische Behandlung - SchrägscherfestigkeitThis European Standard was approved by CEN on 27 February 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12618-3:2004: ESIST EN 12618-3:2004



EN 12618-3:2004 (E)
2 Contents page Foreword.3 1 Scope.4 2 Normative references.4 3 Terms and definitions.4 4 Test method.5 4.1 Principle.5 4.2 Apparatus.5 4.3 Preparations.5 5 Test procedure.10 5.1 Sample.10 5.2 Measurement.10 5.3 Test conditions.11 5.4 Compression testing.11 6 Calculation and expression of results.12 7 Test report.12 Annex A (normative)
Procedure for capping composite test specimens.13
SIST EN 12618-3:2004



EN 12618-3:2004 (E) 3 Foreword This document (EN 12618-3:2004) has been prepared by Technical Committee CEN /TC 104, "Concrete and related products", the secretariat of which is held by DIN. It has been drafted by Sub-Committee 8 "Products and systems for the protection and repair of concrete structures" (Secretariat AFNOR). This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2005, and conflicting national standards shall be withdrawn at the latest by February 2005. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. SIST EN 12618-3:2004



EN 12618-3:2004 (E)
4 1 Scope This document describes the method for determining the slant shear bond strength of all injection products intended to restore the integrity of cracked concrete and covered by prEN 1504-5. The test may be performed upon cracks injected in the dry, damp, wet or with water flowing through them. It should always be carried out after the appropriate period of curing under the standard conditions of test detailed below, but may additionally be performed upon a further set of specimens after a period of artificial ageing by thermal cycling. Whilst the testing of the repaired crack is normally by short term static load, it may also be performed as a creep test by long term static load, or as a dynamic test by the application of a cyclic load. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 196-1, Method of testing cements - Part 1: Determination of strength. EN 1504-1:1998, Products and systems for the protection and repair of concrete structures – Definitions, requirements, quality control and evaluation of conformity – Part 1: Definitions. prEN 1504-5:2001, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 5 : Concrete injection. EN 1766, Products and systems for the protection and repair of concrete structures - Tests methods - Reference concretes for testing. EN 12390-1, Testing hardened concrete – Part 1: Shape, dimensions and other requirements for test specimens and moulds. EN 12390-2, Testing hardened concrete – Part 2: Making and curing specimens for strength tests. EN 12390-4, Testing hardened concrete – Part 4: Compressive strength - Specification for testing machines. EN 13687-4, Products and systems for the protection and repair of concrete structures - Tests methods - Determination of thermal compatibility - Part 4: Dry thermal cycling.
3 Terms and definitions For the purpose of this document, the terms and definitions given in EN 1504-1:1998 and prEN 1504-5:2001 apply. SIST EN 12618-3:2004



EN 12618-3:2004 (E) 5 4 Test method 4.1 Principle The principle of this test is the compressive testing of a restored concrete prism that is scarf jointed at 30° to its main axis, the joint having been formed by the injection repair of a straight line crack in the concrete (see Figure 3). The joint is thus subjected to a combination of shear and compressive stresses. The result is presented as the compressive strength of the composite prism (with observations upon the mode of failure), since this is easily related to conventional concrete appraisal and design procedures. The test specimens are produced by sawing prisms from concrete slabs which have been split in a controlled manner and repaired by injecting the product or system under test. Control specimens of concrete used in the preparation of the slab are also prepared and tested in a similar manner to provide comparative information. 4.2 Apparatus 4.2.1 Compression testing machine conforming to EN 12390-4. 4.2.2 Moulds for casting the concrete slabs shall comply with the accuracy and tolerance requirements of EN 12390-1 and shall be of a size to produce slabs having the dimensions specified in 4.3.8. NOTE A suitable two-gang mould may be made by preparing a steel block 150 mm x 155 mm x 40 mm and machining a slot to receive it in two opposite faces of a 150 mm cube mould complying with EN 12390-1. This then forms two mould cavities each 55 mm wide. 4.2.3 Trapezoidal mild steel plates, having dimensions shown in Figure 1, subject to a tolerance of ± 0,5 mm. 4.2.4 Elastomeric pads 150 mm x 150 mm. The characteristics of the elastomeric material need to be such as to ensure a relatively straight crack when splitting a slab. 10 mm thick reinforced rubber sheet as used in conveyor belting has been found to be suitable, as has 6 mm thick unreinforced polyurethane elastomer sheet of 90 Shore A hardness. 4.2.5 Diamond saw, suitably mounted and capable of producing clean vertical cuts through the 55 mm thickness of the concrete slab. 4.3 Preparations 4.3.1 Preparation of concrete slabs The slabs shall be cast from a reference concrete of the type MC (0,40) or MC (0,45) as defined in EN 1766. After de-moulding they shall be cured for a total of 28 days in accordance with EN 12390-2 before any further conditioning or use. 4.3.2 Slab splitting Assemble the concrete slab with the trapezoidal plates and elastomeric pads as shown in Figure 1. Place this assembly between the platens of a press1) and apply load evenly and smoothly until the slab fractures. This is illustrated at Figure 2. Release the load and remove the assembly carefully from the press. Hold the two halves of the slab lightly together, to prevent loss of any debris from the crack. This may be done by lightly clamping the slab, or by fitting a stou
...

Questions, Comments and Discussion