Copper and copper alloys - Seamless, round copper capillary tubes

This European Standard specifies the composition, property requirements and tolerances on dimensions and on form for seamless round copper capillary tubes for use as metering lines for liquids or gases where close controls over the smooth¬ness and dimensions of the bore are required to ensure uniform flow characteristics.
This European Standard applies to capillary tubes in straight lengths, or in coils, in the size range up to and including 6,10 mm outside diameter and from 0,30 mm up to and including 4,45 mm inside diameter which are intended for restrictor applications. The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.

Kupfer und Kupferlegierungen - Nahtlose, runde Kapillarrohre aus Kupfer

Diese Europäische Norm legt die Zusammensetzung, die Anforderungen an die Eigenschaften, Grenzabmaße und Formtoleranzen für nahtlose, runde Kapillarrohre aus Kupfer fest, die als Messleitung für Flüssigkeiten oder Gase verwendet werden, wobei eine enge Kontrolle der Oberflächenbeschaffenheit und der Maße der Bohrung gefordert wird, um eine gleichmäßige Durchflusscharakteristik zu gewährleisten. Diese Europäische Norm gilt für Kapillarrohre in geraden Längen oder in Ringen mit Außendurchmesser des Rohres bis 6,10 mm und Innendurchmesser von 0,30 mm bis 4,45 mm, die für Durchflussbegrenzer vorgesehen sind. Der Ablauf der Probenentnahme und die Prüfverfahren zur Feststellung der Übereinstimmung mit den Anfor-derungen dieser Europäischen Norm sind ebenfalls festgelegt.

Cuivre et alliages de cuivre - Tubes capillaires, ronds, sans soudure en cuivre

La présente Norme européenne spécifie la composition, les exigences relatives aux caractéristiques et les tolérances relatives aux dimensions et à la forme des tuyaux circulaires en cuivre, de faible diamètre, sans soudure, utilisés dans les installations pour compteur d’eau ou compteur à gaz pour lesquels des contrôles minutieux concernant l’absence de rugosité et les dimensions du diamètre intérieur sont nécessaires pour assurer un débit régulier.
La présente Norme européenne s’applique aux tuyaux de faible diamètre, rectilignes ou en couronne, d’un diamètre extérieur inférieur ou égal à 6,10 mm et d’un diamètre intérieur compris entre 0,30 mm et 4,45 mm, qui sont destinés à des applications de réduction de débit.
Les modes opératoires d’échantillonnage et les méthodes d’essai de vérification de la conformité aux exigences de la présente Norme européenne sont également spécifiés.

Baker in bakrove zlitine - Nevarjene kapilarne cevi z okroglim prerezom

Ta evropski standard določa sestavo, zahteve v zvezi z lastnostmi ter tolerance pri dimenzijah in obliki za nevarjene kapilarne cevi z okroglim prerezom za uporabo v merilnih vodih za tekočine ali pline, kjer je potrebno strogo preverjanje gladkosti in dimenzij izvrtine za zagotavljanje enakih lastnosti pretoka. Ta standard se uporablja za ravne kapilarne cevi ali kapilarne cevi v tuljavah velikosti do vključno 6,10 mm zunanjega premera in od 0,30 mm do vključno 4,45 mm notranjega premera za uporabo v obliki omejeval. Določeni so tudi postopki vzorčenja in preskusne metode za preverjanje skladnosti z zahtevami iz tega evropskega standarda.

General Information

Status
Published
Publication Date
26-Feb-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
19-Feb-2013
Due Date
26-Apr-2013
Completion Date
27-Feb-2013

Relations

Buy Standard

Standard
EN 12450:2013
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baker in bakrove zlitine - Nevarjene kapilarne cevi z okroglim prerezomKupfer und Kupferlegierungen - Nahtlose, runde Kapillarrohre aus KupferCuivre et alliages de cuivre - Tubes capillaires, ronds, sans soudure en cuivreCopper and copper alloys - Seamless, round copper capillary tubes77.150.30Bakreni izdelkiCopper products23.040.15Cevi iz neželeznih kovinNon-ferrous metal pipesICS:Ta slovenski standard je istoveten z:EN 12450:2012SIST EN 12450:2013en,de01-april-2013SIST EN 12450:2013SLOVENSKI
STANDARDSIST EN 12450:20001DGRPHãþD



SIST EN 12450:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12450
November 2012 ICS 23.040.15; 77.150.30 Supersedes EN 12450:1999English Version
Copper and copper alloys - Seamless, round copper capillary tubes
Cuivre et alliages de cuivre - Tuyaux circulaires en cuivre, de faible diamètre, sans soudure
Kupfer und Kupferlegierungen - Nahtlose, runde Kapillarrohre aus Kupfer This European Standard was approved by CEN on 6 October 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12450:2012: ESIST EN 12450:2013



EN 12450:2012 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Terms and definitions .44Designations .54.1Material .54.2Material condition .54.3Product .55Ordering information .66Requirements .76.1Composition .76.2Mechanical properties .76.3Dimensions and tolerances .76.4Tolerances on form.86.5Flow .86.6Surface quality .87Sampling .97.1General .97.2Analysis .97.3Mechanical tests .98Test methods .98.1Analysis .98.2Tensile test . 108.3Hardness test . 108.4Flow test . 108.5Cleanliness test. 108.6Retests . 108.7Rounding of results . 109Declaration of conformity and inspection documentation . 119.1Declaration of conformity . 119.2Inspection documentation . 1110Marking, packaging, labelling . 11Bibliography . 12 Tables Table 1 — Mechanical properties . 7Table 2 — Tolerances on tubes in straight lengths . 8Table 3 — Tolerances on flow . 8Table 4 — Sampling rate . 9 SIST EN 12450:2013



EN 12450:2012 (E) 3 Foreword This document (EN 12450:2012) has been prepared by Technical Committee CEN/TC 133 “Copper and copper alloys”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2013, and conflicting national standards shall be withdrawn at the latest by May 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12450:1999. In comparison with EN 12450:1999, the following significant technical changes were made: a) 6.6 "Surface quality", has been modified; b) In 8.5 "Cleanliness test" the text regarding the determination of lubricant residue as described in EN 723 has been added. This is one of a series of European Standards for copper and copper alloy tubes. Other products are, or will be, specified as follows:  EN 1057, Copper and copper alloys — Seamless, round copper tubes for water and gas in sanitary and heating applications  EN 12449, Copper and copper alloys — Seamless, round tubes for general purposes  EN 12451, Copper and copper alloys — Seamless, round tubes for heat exchangers  EN 12452, Copper and copper alloys — Rolled, finned, seamless tubes for heat exchangers  EN 12735-1, Copper and copper alloys — Seamless, round copper tubes for air conditioning and refrigeration — Part 1: Tubes for piping systems  EN 12735-2, Copper and copper alloys — Seamless, round copper tubes for air conditioning and refrigeration — Part 2: Tubes for equipment
 EN 13348, Copper and copper alloys — Seamless, round copper tubes for medical gases or vacuum  EN 13349, Copper and copper alloys — Pre-insulated copper tubes with solid covering  EN 13600, Copper and copper alloys — Seamless copper tubes for electrical purposes Within its programme of work, Technical Committee CEN/TC 133 requested CEN/TC 133/WG 3 "Copper tubes (installation and industrial)" to revise the following standard:  EN 12450:1999, Copper and copper alloys — Seamless, round copper capillary tubes. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 12450:2013



EN 12450:2012 (E) 4 1 Scope This European Standard specifies the composition, property requirements and tolerances on dimensions and on form for seamless round copper capillary tubes for use as metering lines for liquids or gases where close controls over the smoothness and dimensions of the bore are required to ensure uniform flow characteristics. This European Standard applies to capillary tubes in straight lengths, or in coils, in the size range up to and including 6,10 mm outside diameter and from 0,30 mm up to and including 4,45 mm inside diameter which are intended for restrictor applications. The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1057:2006, Copper and copper alloys — Seamless, round copper tubes for water and gas in sanitary and heating applications EN 1655, Copper and copper alloys — Declarations of conformity EN 10204, Metallic products — Types of inspection documents EN ISO 6507-1, Metallic materials — Vickers hardness test — Part 1: Test method (ISO 6507-1) EN ISO 6892-1, Metallic materials — Tensile testing — Part 1: Method of test at room temperature
(ISO 6892-1) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1057:2006 and the following apply. 3.1 seamless round tube hollow semi-finished product, circular in cross-section, having a uniform wall thickness, which at all stages of production has a continuous periphery 3.2 mean diameter arithmetical mean of the maximum and minimum outside diameters through the same cross-section of the tube [SOURCE: EN 1057:2006, 3.5] 3.3 deviation from circular form difference between the maximum and minimum outside diameters measured at any one cross-section of the tube [SOURCE: EN 1057:2006, 3.6] 3.4 capillary tube tube of small inside diameter with an inside surface of high quality and conforming to close diameter tolerances Note 1 to entry: It is subject to special tests to ensure precision and uniformity of bore, having been specially cleaned. SIST EN 12450:2013



EN 12450:2012 (E) 5 4 Designations 4.1 Material 4.1.1 General The material is designated either by symbol or number (see 6.1). 4.1.2 Symbol The material symbol designation is based on the designation system given in ISO 1190-1. NOTE Although material symbol designations used in this standard might be the same as those in other standards using the designation system given in ISO 1190-1, the detailed composition requirements are not necessarily the same. 4.1.3 Number The material number designation is in accordance with the system given in EN 1412. 4.2 Material condition For the purposes of this standard, the following designations, which
...