Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

This part of CISPR 16 is designated a basic standard, which specified the methods of measurement of immunity to EMC phenomena in the frequency range 9 kHz to 18 GHz.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit -- Teil 2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der gestrahlten Störaussendung

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnées

La présente partie de la CISPR 16 est une norme fondamentale qui spécifie la méthode de mesure du champ perturbateur rayonné, dans la gamme de fréquences de 9 kHz à 18 GHz. La publication CISPR 16-2 a été réorganisée en 4 parties, dans le but de pouvoir gérer plus facilement son évolution et maintenance. Cette première édition de la CISPR 16-2-3, ainsi que les CISPR 16-2-1, CISPR 16-2-2 et CISPR 16-2-4, annule et remplace la seconde édition de la CISPR 16-2 publiée en 2003. Elle contient les articles en rapport avec la CISPR 16-2 sans modifications de leur contenu technique.

Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti - 2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih motenj (CISPR 16-2-3:2006)

General Information

Status
Withdrawn
Publication Date
17-Jul-2007
Withdrawal Date
21-Nov-2013
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
22-Nov-2013
Due Date
15-Dec-2013
Completion Date
22-Nov-2013

Relations

Buy Standard

Standard
EN 55016-2-3:2007
English language
97 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 55016-2-3:2007
01-marec-2007
Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti -
2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih
motenj (CISPR 16-2-3:2006)
Specification for radio disturbance and immunity measuring apparatus and methods --
Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance
measurements
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit -- Teil
2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und
Störfestigkeit - Messung der gestrahlten Störaussendung
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-3:
Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations
rayonnées
Ta slovenski standard je istoveten z: EN 55016-2-3:2006
ICS:
17.240 Merjenje sevanja Radiation measurements
33.100.20 Imunost Immunity
SIST EN 55016-2-3:2007 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 55016-2-3:2007

---------------------- Page: 2 ----------------------

SIST EN 55016-2-3:2007


EUROPEAN STANDARD
EN 55016-2-3

NORME EUROPÉENNE
December 2006
EUROPÄISCHE NORM

ICS 33.100.10; 33.100.20 Supersedes EN 55016-2-3:2004 + A1:2005 + A2:2005


English version


Specification for radio disturbance
and immunity measuring apparatus and methods
Part 2-3: Methods of measurement of disturbances and immunity -
Radiated disturbance measurements
(CISPR 16-2-3:2006)


Spécifications des méthodes  Anforderungen an Geräte
et des appareils de mesure und Einrichtungen sowie Festlegung
des perturbations radioélectriques der Verfahren zur Messung
et de l'immunité aux perturbations der hochfrequenten Störaussendung
radioélectriques (Funkstörungen) und Störfestigkeit
Partie 2-3: Méthodes de mesure Teil 2-3: Verfahren zur Messung
des perturbations et de l'immunité - der hochfrequenten Störaussendung
Mesures des perturbations rayonnées (Funkstörungen) und Störfestigkeit -
(CISPR 16-2-3:2006) Messung der gestrahlten Störaussendung
(CISPR 16-2-3:2006)


This European Standard was approved by CENELEC on 2006-11-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55016-2-3:2006 E

---------------------- Page: 3 ----------------------

SIST EN 55016-2-3:2007
EN 55016-2-3:2006 - 2 -
Foreword
The text of document CISPR/A/657/FDIS, future edition 2 of CISPR 16-2-3, prepared by CISPR SC A,
Radio-interference measurements and statistical methods, was submitted to the IEC-CENELEC parallel
vote and was approved by CENELEC as EN 55016-2-3 on 2006-11-01.
This European Standard supersedes EN 55016-2-3:2004 + A1:2005 + A2:2005.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2007-08-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2009-11-01
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard CISPR 16-2-3:2006 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 55016-2-3:2007
- 3 - EN 55016-2-3:2006

Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

CISPR 13 (mod) 2001 Sound and television broadcast receivers EN 55013 2001
and associated equipment - Radio
disturbance characteristics - Limits and
methods of measurement


CISPR 14-1 2005 Electromagnetic compatibility - EN 55014-1 2006
Requirements for household appliances,
electric tools and similar apparatus
Part 1: Emission


CISPR 16-1-1 2003 Specification for radio disturbance and EN 55016-1-1 2004
immunity measuring apparatus and methods
Part 1-1: Radio disturbance and immunity
measuring apparatus - Measuring apparatus


CISPR 16-1-2 2003 Specification for radio disturbance and EN 55016-1-2 2004
immunity measuring apparatus and methods
Part 1-2: Radio disturbance and immunity
measuring apparatus - Ancillary equipment -
Conducted disturbances


CISPR 16-1-4 2003 Specification for radio disturbance and EN 55016-1-4 2004
immunity measuring apparatus and methods
Part 1-4: Radio disturbance and immunity
measuring apparatus - Ancillary equipment -
Radiated disturbances


CISPR 16-1-5 2003 Specification for radio disturbance and EN 55016-1-5 2004
immunity measuring apparatus and methods
Part 1-5: Radio disturbance and immunity
measuring apparatus - Antenna calibration
test sites for 30 MHz to 1 000 MHz


CISPR 16-2-1 2003 Specification for radio disturbance and EN 55016-2-1 2004
immunity measuring apparatus and methods
Part 2-1: Methods of measurement of
disturbances and immunity - Conducted
disturbance measurements


CISPR 16-2-2 2003 Specification for radio disturbance and EN 55016-2-2 2004
immunity measuring apparatus and methods
Part 2-2: Methods of measurement of
disturbances and immunity - Measurement of
disturbance power

---------------------- Page: 5 ----------------------

SIST EN 55016-2-3:2007
EN 55016-2-3:2006 - 4 -
Publication Year Title EN/HD Year
CISPR 16-2-4 2003 Specification for radio disturbance and EN 55016-2-4 2004
immunity measuring apparatus and methods
Part 2-4: Methods of measurement of
disturbances and immunity - Immunity
measurements


CISPR 16-3 2003 Specification for radio disturbance and - -
A1 2005 immunity measuring apparatus and methods - -
Part 3: CISPR technical reports


CISPR 16-4-1 2003 Specification for radio disturbance and - -
immunity measuring apparatus and methods
Part 4-1: Uncertainties, statistics and limit
modeling - Uncertainties in standardized EMC
tests


CISPR 16-4-2 2003 Specification for radio disturbance and EN 55016-4-2 2004
immunity measuring apparatus and methods
Part 4-2: Uncertainties, statistics and limit
modelling - Uncertainty in EMC
measurements


CISPR 16-4-3 2003 Specification for radio disturbance and - -
immunity measuring apparatus and methods
Part 4-3: Uncertainties, statistics and limit
modelling - Statistical considerations in the
determination of EMC compliance of mass-
produced products


1) 2)
IEC 61000-4-3 - Electromagnetic compatibility (EMC) EN 61000-4-3 2006
Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency,
electromagnetic field immunity test




1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 6 ----------------------

SIST EN 55016-2-3:2007
COMMISSION
CISPR

ÉLECTROTECHNIQUE
16-2-3

INTERNATIONALE



INTERNATIONAL
Deuxième édition
ELECTROTECHNICAL

Second edition
2006-07
COMMISSION


COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
Spécifications des méthodes et des appareils
de mesure des perturbations radioélectriques et
de l'immunité aux perturbations radioélectriques –
Partie 2-3:
Méthodes de mesure des perturbations et de
l'immunité – Mesures des perturbations rayonnées

Specification for radio disturbance and immunity
measuring apparatus and methods –
Part 2-3:
Methods of measurement of disturbances and
immunity – Radiated disturbance measurements

 IEC 2006 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
XD
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 7 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 3 –
CONTENTS
FOREWORD.9

1 Scope.13
2 Normative references .13
3 Terms and definitions .15
4 Types of disturbance to be measured .21
5 Connection of measuring equipment.23
6 General measurement requirements and conditions .25
7 Measurement of radiated disturbances .41
8 Automated measurement of emissions .123

Annex A (informative) Measurement of disturbances in the presence of ambient emissions135
Annex B (informative) Use of spectrum analyzers and scanning receivers (see clause 6) .163
Annex C (informative) Example of the uncertainty budget .169
Annex D  (informative)  Scan rates and measurement times for use with the average
detector .171
Annex E (informative) Explanation of APD measurement method applying to the
compliance test.179

Figure 1 – Measurement of a combination of a CW signal (“NB”) and an impulsive
signal (“BB”) using multiple sweeps with maximum hold.35
Figure 2 – Example of a timing analysis.37
Figure 3 – A broadband spectrum measured with a stepped receiver .39
Figure 4 – Intermittent narrowband disturbances measured using fast short repetitive
sweeps with maximum hold function to obtain an overview of the emission spectrum.39
Figure 5 – Concept of electric field strength measurements made on an open area test
site (OATS) with the direct and reflective rays arriving at the receiving antenna.43
Figure 6 – Typical test set-up in FAR, where a, b, c and e depend on the room
performance .51
Figure 7 – Typical test set-up for table-top equipment within the test volume of a FAR .55
Figure 8 – Typical test set-up for floor standing equipment within the test volume of a FAR .57
Figure 9 – Test set-up for tabletop equipment .71
Figure 10 – Test set-up for tabletop equipment, Top view .73
Figure 11 – Test set-up for floor-standing equipment .75
Figure 12 – Test set-up for floor-standing equipment, Top view .77
Figure 13 – Position of planes for uniform field calibration (top-view).79
Figure 14 – Measurement method above 1 GHz, receive antenna in vertical
polarization.85
Figure 15 – Illustration of height scan requirements for two different categories of EUTs .89

---------------------- Page: 8 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 5 –
Figure 16 – Method of measurement – Substitution method (see 7.4.1 and 7.4.3).101
Figure 17 – Determination of the transition distance .115
Figure 18 – Concept of magnetic field induced current measurements made with the
loop antenna system.121
Figure A.1 – Flow diagram for the selection of bandwidths and detectors and the
estimated measurement errors due to that selection .139
Figure A.2 – Relative difference in adjacent emission amplitudes during preliminary
testing .143
Figure A.3 – Disturbance by an unmodulated signal (dotted line) .145
Figure A.4 – Disturbance by an amplitude-modulated signal (dotted line).145
Figure A.5 – Indication of an amplitude-modulated signal as a function of modulation
frequency with the QP detector in CISPR bands B, C and D .147
Figure A.6 – Indication of a pulse-modulated signal (pulse width 50 µs) as a function of
pulse repetition frequency with peak, QP and average detectors.149
Figure A.7 – Disturbance by a broadband signal (dotted line) .149
Figure A.8 – Unmodulated EUT disturbance (dotted line) .151
Figure A.9 – Amplitude-modulated EUT disturbance (dotted line).151
Figure A.10 – Increase of peak value with superposition of two unmodulated signals
(U - level of ambient emission; U - level of EUT disturbance) .157
a i
Figure A.11 – Determination of the amplitude of the disturbance signal by means of the
amplitude ratio d and the factor i.157
Figure A.12 – Increase of average indication measured with a real receiver and
calculated from equation (A.8) .159
Figure D.1 – Weighting function of a 10 ms pulse for peak (“PK”) and average
detections with (“CISPR AV”) and without (“AV”) peak reading: meter time constant
160 ms.175
Figure D.2 – Weighting functions of a 10 ms pulse for peak (“PK”) and average
detections with (“CISPR AV”) and without (“AV”) peak reading: meter time constant
100 ms.175
Figure D.3 – Example of weighting functions (of a 1 Hz pulse) for peak (“PK”) and
average detections as a function of pulse width: meter time constant 160 ms .177
Figure D.4 – Example of weighting functions (of a 1 Hz pulse) for peak (“PK”) and
average detections as a function of pulse width: meter time constant 100 ms .177
Figure E.1 – Example of APD measurement method 1 for fluctuating disturbances .181
Figure E.2 – Example of APD measurement method 2 for fluctuating disturbances .183

Table 1 – Minimum scan times for the three CISPR bands with peak and quasi-peak
detectors .31
Table 2 – Minimum dimension of w (w .87
min)
Table 3 – Example values of w for three antenna types .89
Table 4 – Recommended antenna heights to guarantee signal interception (for
prescan) in the frequency range 30 MHz to 1 000 MHz.129

---------------------- Page: 9 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 7 –
Table A.1 – Combinations of EUT disturbance and ambient emissions.137
Table A.2 – Measurement error depending on the detector type and on the combination
of ambient and disturbing signal spectra .161
Table C.1 – Uncertainty budget for emission measurements in a 3 m FAR.169
Table D.1 – Pulse suppression factors and scan rates for a 100 Hz video bandwidth .173
Table D.2 – Meter time constants and the corresponding video bandwidths and
maximum scan rates .175

---------------------- Page: 10 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 9 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
____________

SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –

Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard CISPR 16-2-3 has been prepared by CISPR subcommittee A: Radio
interference measurements and statistical methods.
This second edition of CISPR 16-2-3 cancels and replaces the first edition published in 2003,
amendment 1 (2005) and amendment 2 (2005).
The document CISPR/A/657/FDIS, circulated to the National Committees as amendment 3,
led to the publication of the new edition.

---------------------- Page: 11 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 11 –
The text of this standard is based on the first edition, its amendment 1, amendment 2 and the
following documents:
FDIS Report on voting
CISPR/A/657/FDIS CISPR/A/672/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 12 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 13 –
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –

Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements



1 Scope
This part of CISPR 16 is designated a basic standard, which specifies the methods of
measurement of radiated disturbance phenomena in the frequency range 9 kHz to 18 GHz.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
CISPR 13:2001, Sound and television broadcast receivers and associated equipment – Radio
disturbance characteristics – Limits and methods of measurement
CISPR 14-1:2005, Electromagnetic compatibility – Requirements for household appliances,
electric tools and similar apparatus – Part 1: Emission
CISPR 16-1-1:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring
apparatus
CISPR 16-1-2:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-2: Radio disturbance and immunity measuring apparatus – Ancillary
equipment – Conducted disturbances
CISPR 16-1-4:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Ancillary
equipment - Radiated disturbances
CISPR 16-1-5:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-5: Radio disturbance and immunity measuring apparatus – Antenna
calibration and site validation
CISPR 16-2-1:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 2-1: Methods of measurement of disturbances and immunity – Conducted
disturbance measurements

---------------------- Page: 13 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 15 –
CISPR 16-2-2:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 2-2: Methods of measurement of disturbances and immunity –
Measurement of disturbance power
CISPR 16-2-4:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 2-4: Methods of measurement of disturbances and immunity – Immunity
measurements
CISPR 16-3:2003, Specification for radio disturbance and Immunity measuring apparatus and
methods – Part 3: CISPR technical reports
Amendment 1 (2005)
CISPR 16-4-1:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 4-1: Uncertainties, statistics and limit modelling – Uncertainties in
standardized EMC tests
CISPR 16-4-2:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 4-2: Uncertainties, statistics and limit modelling – Uncertainty in EMC
measurements
CISPR 16-4-3:2003, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 4-3: Uncertainties, statistics and limit modelling – Statistical
considerations in the determination of EMC compliance of mass-produced products
IEC 61000-4-3, Electromagnetic compatibility (EMC) – Part 4-3: Testing and measurement
techniques – Radiated, radio-frequency, electromagnetic field immunity test
3 Terms and definitions
For the purpose of this part of CISPR 16, the definitions of IEC 60050(161) apply, as well as
the following:
3.1
associated equipment
1) transducers (e.g. probes, networks and antennas) connected to a measuring receiver or
test generator
2) transducers (e.g. probes, networks, antennas) which are used in the signal or disturbance
transfer between an EUT and measuring equipment or a (test-) signal generator
3.2
EUT
the equipment (devices, appliances and systems) subjected to EMC (emission) compliance
tests

---------------------- Page: 14 ----------------------

SIST EN 55016-2-3:2007
CISPR 16-2-3  IEC:2006 – 17 –
3.3
product publication
publication specifying EMC requirements for a product or product family, taking into account
specific aspects of such a product or product family
3.4
emission limit (from a disturbing source)
the specified maximum emission level of a source of electromagnetic disturbance
[IEV 161-03-12]
3.5
ground reference
a connection that constitutes a defined parasitic capacitance to the surrounding of an EUT
and serves as reference potential
NOTE See also IEV 161-04-36.
3.6
(electromagnetic) emission
the phenomenon by which electromagnetic energy emanates from a source
[IEV 161-01-08]
3.7
coaxial cable
a cable containing one or more coaxial lines, typically used for a matched connection of
associated equipment to the measuring equipment or (test-)signal generator providing a
specified characteristic impedance and a specified maximum allowable cable transfer
impedance
3.8
measuring receiver
a receiver for the measurement of disturbances with different detectors
NOTE The receiver is specified according to CISPR 16-1-1.
3.9
test configuration
gives the specified measurement arrangement of the EUT in which an emission level i
...

Questions, Comments and Discussion