Abstract

The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in part 1-2: Transportation.
NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.

Status
Published
Publication Date
31-Jan-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Documents

Standard

SIST EN 300 019-1-1 V2.1.4:2006

English language (12 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 300 019-1-1 V2.1.4:2006 is the Slovenian adoption of ETSI EN 300 019-1-1 V2.1.4, an Environmental Engineering (EE) standard from the European Telecommunications Standards Institute (ETSI). It classifies the environmental conditions and severities that telecommunications equipment may face during storage, so engineers, quality managers, and buyers can specify the storage environment equipment is intended to withstand.

What does SIST EN 300 019-1-1 V2.1.4:2006 specify?

SIST EN 300 019-1-1 V2.1.4:2006 specifies storage classes for telecommunications equipment and the environmental severities linked to each class. It is about storage only, with temporary storage during transport covered by Part 1-2: Transportation, and it applies to packaged equipment when the equipment is stored in its package.

The document is organized into scope, references, definitions, environmental classes, and environmental conditions. Clause 4 defines the storage classes, and clause 5 sets out the environmental parameters used to describe them.

What are the key requirements of SIST EN 300 019-1-1 V2.1.4:2006?

SIST EN 300 019-1-1 V2.1.4:2006 classifies storage into four named classes: 1.1, 1.2, 1.3, and 1.3E. In practice, this gives a buyer or designer a common way to describe the intended storage site before packaging, warehousing, or acceptance testing is decided.

Clause 4 links each class to IEC 60721-3-1 class combinations and uses climatograms in Figures 1 to 3. That matters because the class label is shorthand for a full environmental profile, not just a temperature limit.

Clause 5.1 gathers the climatic conditions for the classes. It covers low and high air temperature, relative and absolute humidity, rain intensity, temperature change, air pressure, solar radiation, heat radiation, air movement, condensation, precipitation, water from sources other than rain, and icing or frosting. In practice, this is the main checklist for deciding whether a store room, shed, yard, or other location matches the intended class.

Clause 5.2 sets the biological conditions. It separates locations with no or negligible biological exposure from locations where mould, fungus, rodents, and other harmful animals may be present, excluding termites. This matters when storage is in damp, open, or poorly sealed areas.

Clause 5.3 covers chemically active substances, including salts, sulphur dioxide, hydrogen sulphide, chlorine, hydrogen chloride, hydrogen fluoride, ammonia, ozone, and nitrogen oxides. It gives mean and maximum levels, and it notes a special class 1C1 for classes 1.1 and 1.2. In practice, this is relevant for coastal, industrial, or polluted storage environments.

Clause 5.4 addresses mechanically active substances such as sand and dust, including suspension and sedimentation. This helps users judge whether dust control, sealing, or cleaning measures are needed.

Clause 5.5 specifies mechanical conditions: stationary vibration, non-stationary vibration including shock, and static load. It also points to IEC 60721-3-1 and IEC 60068-2-27 for shock-response spectrum definitions. For a storage plan, this is the part that captures vibration from nearby machines, passing vehicles, handling, and stacking load.

What terms does SIST EN 300 019-1-1 V2.1.4:2006 define?

Storage is a site where equipment is kept for long periods and is not intended for use during that time.

Weatherprotected location is a location where equipment is protected from weather influences.

Non-weatherprotected location is a location where equipment is not protected from direct weather influences.

Relative humidity is the ratio of water vapour pressure in moist air to the saturation vapour pressure at the same temperature.

Absolute humidity is the mass of water vapour per cubic metre of dry air in an air-water vapour mixture.

Partly weatherprotected location is a weatherprotected location where direct weather influences are not completely excluded.

Who uses SIST EN 300 019-1-1 V2.1.4:2006?

Telecommunications equipment manufacturers, system integrators, and design engineers use SIST EN 300 019-1-1 V2.1.4:2006 to define the storage environment a product must tolerate. Test laboratories and environmental engineers use it when selecting storage classes and preparing environmental assessments.

Quality managers and buyers use it to write storage conditions into specifications and procurement documents. Warehousing, logistics, and service organizations use it to judge whether a room, building, garage, yard, or other storage site fits a stated class.

Which standards are used with SIST EN 300 019-1-1 V2.1.4:2006?

The document refers to ETSI ETR 035 for guidance and terminology, IEC 60721-3-1 for the environmental classification framework, IEC 60068-2-27 for shock, and IEC 60721-2-4 for solar radiation and temperature context. The foreword also places this part within the ETSI series together with Part 1-0 as the overview, Part 1-2 for transportation, and Part 2 for environmental tests.

What does the SIST EN 300 019-1-1 V2.1.4:2006 document contain?

The document contains three class descriptions with climatograms in Figures 1 to 3, plus five tables that summarize climatic, biological, chemically active, mechanically active, and mechanical conditions. Clause 4 explains the storage classes and the environments they represent, while clause 5 turns those classes into measurable or observable parameters.

For practical use, the document helps readers map a real storage site to a standardized class and then compare the site against the environmental profile. It is a classification document, so it provides the environmental description that supports later testing and specification work rather than test methods itself.

Buy Documents

Standard

SIST EN 300 019-1-1 V2.1.4:2006

English language (12 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

IMP NDT d.o.o.

Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.

SA Slovenia Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 019-1-1 V2.1.4:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-1: Classification of environmental conditions; Storage". This standard covers: The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in part 1-2: Transportation. NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.

The present document defines classes of environmental conditions and their severities to which telecommunication equipment may be exposed during storage. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. NOTE 1: Temporary storage during transport is included in part 1-2: Transportation. NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.

SIST EN 300 019-1-1 V2.1.4:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 019-1-1 V2.1.4:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-2006
2NROMVNLLQåHQLULQJ (( ±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMD]D
WHOHNRPXQLNDFLMVNRRSUHPR±GHO.ODVLILNDFLMDRNROMVNLKSRJRMHY±
6NODGLãþHQMH
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-1: Classification of environmental conditions;
Storage
Ta slovenski standard je istoveten z: EN 300 019-1-1 Version 2.1.4
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

European Standard (Telecommunications series)

Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-1: Classification of environmental conditions;
Storage
2 ETSI EN 300 019-1-1 V2.1.4 (2003-04)

Reference
REN/EE-01027-1-1[2]
Keywords
environment, testing, equipment practice
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 019-1-1 V2.1.4 (2003-04)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Definitions.5
4 Environmental classes.6
4.1 Class 1.1: Weatherprotected, partly temperature-controlled storage locations .6
4.2 Class 1.2: Weatherprotected, not temperature-controlled storage locations.7
4.3 Class 1.3: Non-weatherprotected storage locations; class 1.3E: non-weatherprotected storage locations-
extended .8
5 Environmental conditions.9
5.1 Climatic conditions.9
5.2 Biological conditions.9
5.3 Chemically active substances .10
5.4 Mechanically active substances.10
5.5 Mechanical conditions.11
History .12

ETSI
4 ETSI EN 300 019-1-1 V2.1.4 (2003-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 1, sub-part 1 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 1-0 forms a general overview of part 1.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.

National transposition dates
Date of latest announcement of this EN (doa): 31 July 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 January 2004
Date of withdrawal of any conflicting National Standard (dow): 31 January 2004

ETSI
5 ETSI EN 300 019-1-1 V2.1.4 (2003-04)
1 Scope
The present document defines classes of environmental conditions and their severities to which telecommunication
equipment may be exposed during storage. The severities specified are those which will have a low probability of being
exceeded; generally less than 1 %.
NOTE 1: Temporary storage during transport is included in part 1-2: Transportation.
NOTE 2: If the equipment is stored in its package, the environmental conditions apply to the packaged equipment.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] ETSI ETR 035: "Equipment Engineering (EE); Environmental engineering; Guidance and
terminology".
[2] IEC 60721-3-1: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 1: Storage".
[3] IEC 60068-2-27: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[4] IEC 60721-2-4: "Classification of environmental conditions. Part 2: Environmental conditions
appearing in nature: Solar radiation and temperature".
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
storage: certain site where the equipment is placed for long periods but is not intended for use during these periods
weatherprotected location: location at which the equipment is protected from weather influences
NOTE 1: Totally weatherprotected location: Direct weather influences are totally excluded.
NOTE 2: Partly weatherprotected location: Direct weather influences are not completely excluded.
ETSI
6 ETSI EN 300 019-1-1 V2.1.4 (2003-04)
4 Environmental classes
The classes shown in parentheses, e.g. (1C1), may be selected for special applications.
4.1 Class 1.1: Weatherprotected, partly temperature-controlled
storage locations
This class is a combination of classes 1K3/1Z2/1B1/1C2(1C1)/1S2/1M2 in IEC 60721-3-1 [2].
This class applies to weatherprotected partly temperature controlled storage. Humidity
...