Self-ballasted fluorescent lamps for general lighting services - Safety requirements (IEC 60968:2015, modified + COR1:2015, modified)

This International Standard specifies the safety and interchangeability requirements, together
with the test methods and conditions required to show compliance of tubular fluorescent
lamps with integrated means for controlling starting and stable operation (self-ballasted
fluorescent lamps).
These lamps are intended for domestic and similar general lighting purposes, having a rated
voltage of 50 V to 250 V, having a rated frequency of 50 Hz or 60Hz and having IEC 60061-1
compliant caps.
For a cap-holder system not specifically mentioned in this standard, the relevant information
on safety related tests provided by the manufacturer will apply.
The requirements of this standard relate only to type testing.
Recommendations for whole product testing or batch testing are given in Annex A.
This part of the standard covers photobiological safety according to IEC 62471 and
IEC TR 62471-2. Blue light and infrared hazards are below the level which requires marking.

Leuchtstofflampen mit eingebautem Vorschaltgerät für Allgemeinbeleuchtung - Sicherheitsanforderungen (IEC 60968:2015, modifiziert + COR1:2015, modifiziert)

Lampes à fluorescence à ballast intégré pour l'éclairage général - Règles de sécurité (IEC 60968:2015, modifiée + COR1:2015, modifiée)

L'IEC 60968:2015 spécifie les exigences de sécurité et d'interchangeabilité ainsi que les méthodes et les conditions d'essais exigés pour démontrer la conformité des lampes tubulaires à fluorescence à dispositif intégré d'amorçage et de stabilisation du fonctionnement (lampes à fluorescence à ballast intégré). Cette troisième édition annule et remplace la deuxième édition, parue en 2012. Cette édition constitue une révision technique. La présente édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente, avec des ajouts concernant:
a) les culots et la prévention de la mauvaise utilisation des culots;
b) l'interchangeabilité;
c) l'endurance mécanique et électrique;
d) les lignes de fuite et distances d'isolement;
e) les précautions sur la fin de la durée de vie des lampes;
f) le fonctionnement anormal;
g) les conditions d'essai pour les lampes à variation d'intensité et à trois intensités;
h) le marquage relatif au contact avec l'eau;
i) la vérification et évaluation;
j) les informations pour la conception du luminaire sous forme d'annexes.

Sijalke za splošno razsvetljavo z vgrajeno predstikalno napravo - Varnostne zahteve (IEC 60968:2015, spremenjen+ COR1:2015, spremenjen)

Ta mednarodni standard določa zahteve za varnost in zamenljivost vključno s preskusnimi metodami in pogoji, ki so potrebni za preverjanje skladnosti cevnih fluorescentnih sijalk z vključenimi sredstvi za nadzorovan vklop in stabilno delovanje (fluorescentne sijalke z vgrajeno predstikalno napravo).
Te sijalke so namenjene za domačo in podobno splošno razsvetljavo ter imajo nazivno napetost 50 V do 250 V, nazivno frekvenco 50 Hz ali 60 Hz in vznožke, skladne s standardom IEC 60061-1.
Za sistem vznožkov/okovov, ki ni izrecno naveden v tem standardu, se uporabljajo ustrezne informacije o preskusih v zvezi z varnostjo, ki jih zagotovi proizvajalec. Zahteve iz tega standarda se nanašajo samo na tipsko preskušanje. Priporočila za preskušanje celotnega izdelka ali serije so podana v dodatku A. Ta del standarda obravnava fotobiološko varnost glede na standarda IEC 62471 in IEC/TR 62471-2. Nevarnost zaradi modre ali infrardeče svetlobe je pod nivojem, ki zahteva označevanje.

General Information

Status
Published
Publication Date
04-Aug-2015
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
15-May-2015
Due Date
20-Jul-2015
Completion Date
05-Aug-2015

Relations

Buy Standard

Standard
EN 60968:2015
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60968:2015
01-september-2015
1DGRPHãþD
SIST EN 60968:2013
SIST EN 60968:2013/A11:2015
Sijalke za splošno razsvetljavo z vgrajeno predstikalno napravo - Varnostne
zahteve (IEC 60968:2015, spremenjen+ COR1:2015, spremenjen)
Self-ballasted fluorescent lamps for general lighting services - Safety requirements (IEC
60968:2015, modified + COR1:2015, modified)
Leuchtstofflampen mit eingebautem Vorschaltgerät für Allgemeinbeleuchtung -
Sicherheitsanforderungen (IEC 60968:2015, modifiziert + COR1:2015, modifiziert)
Lampes à fluorescence à ballast intégré pour l'éclairage général - Règles de sécurité
(IEC 60968:2015, modifiée + COR1:2015, modifiée)
Ta slovenski standard je istoveten z: EN 60968:2015
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN 60968:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60968:2015

---------------------- Page: 2 ----------------------

SIST EN 60968:2015


EUROPEAN STANDARD EN 60968

NORME EUROPÉENNE

EUROPÄISCHE NORM
May 2015
ICS 29.140.30 Supersedes EN 60968:2013
English Version
Self-ballasted fluorescent lamps for general lighting services -
Safety requirements
(IEC 60968:2015, modified + COR1:2015, modified)
Lampes à fluorescence à ballast intégré pour l'éclairage Leuchtstofflampen mit eingebautem Vorschaltgerät für
général - Règles de sécurité Allgemeinbeleuchtung - Sicherheitsanforderungen
(IEC 60968:2015, modifiée + COR1:2015, modifiée) (IEC 60968:2015, modifiziert + COR1:2015, modifiziert)
This European Standard was approved by CENELEC on 2015-03-30. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 60968:2015 E

---------------------- Page: 3 ----------------------

SIST EN 60968:2015
EN 60968:2015 - 2 -


Foreword
The text of document 34A/1811/FDIS, future edition 3 of IEC 60968 prepared by subcommittee 34A
“Lamps”, of IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN 60968:2015.
A draft amendment, which covers common modifications to IEC 60968 (34A/1811/FDIS), was
prepared by CLC/TC 34A "Lamps" and approved by CENELEC.
The following dates are fixed:
• latest date by which the document has
(dop) 2016-03-30
to be implemented at national level by
publication of an identical
national standard or by endorsement
• latest date by which the national
(dow) 2018-03-30
standards conflicting with the document

have to be withdrawn

This document supersedes EN 60968:2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Endorsement notice
The text of the International Standard IEC 60968:2015 + COR1:2015 was approved by CENELEC as
a European Standard with agreed common modifications.

---------------------- Page: 4 ----------------------

SIST EN 60968:2015
- 3 - EN 60968:2015
COMMON MODIFICATIONS
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with
their corresponding European publications

Delete all references to E17, E26 and E39 lamp caps in the following clauses and figures:
Clause 6 Interchangeability (Table 2)
Clause 9 Mechanical strength (Table 3 and 4)
Clause 10 Cap temperature rise (Table 5)
Figure 5 Holder for torsion test on lamps with screw caps

Bibliography Add the following standards:
Add the following notes for the standards indicated:
IEC 60432-1 NOTE Harmonized as EN 60432-1
IEC 60529:1989 NOTE Harmonized as EN 60529:1991 (not modified)
IEC 62471:2006 NOTE Harmonized as EN 62471:2008 (modified).
- - - - -

---------------------- Page: 5 ----------------------

SIST EN 60968:2015
EN 60968:2015 - 4 -


Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.

NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60061-1 - Lamp caps and holders together EN 60061-1 -
with gauges for the control of interchangeability
and safety -
Part 1: Lamp caps

IEC 60061-3 - Lamp caps and holders together EN 60061-3 -
with gauges for the control of interchangeability
and safety -
Part 3: Gauges

IEC 60360 - Standard method of measurement of lamp cap EN 60360 -
temperature rise
IEC 60598-1 - Luminaires – EN 60598-1 -
Part 1: General requirements and tests

IEC 60695-2-10 - Fire hazard testing - EN 60695-2-10 -
Part 2-10: Glowing/hot-wire based test methods -
Glow-wire apparatus and common test procedure

IEC 60695-2-11 2000 Fire hazard testing - EN 60695-2-11 2001
Part 2-11: Glowing/hot-wire based test methods -
Glow-wire flammability test method for end-
products

IEC 60901 - Single-capped fluorescent lamps - Performance EN 60901 -
specifications
IEC 61199 - Single-capped fluorescent lamps – Safety EN 61199 -
specifications
IEC 61347-1 2015 Lamp controlgear – EN 61347-1 2015
Part 1: General and safety requirements
ISO 4046-4 2002 Paper, board, pulps and related terms -
Vocabulary -
Part 4: Paper and board grades and converted
products

---------------------- Page: 6 ----------------------

SIST EN 60968:2015



IEC 60968

®


Edition 3.0 2015-02




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Self-ballasted fluorescent lamps for general lighting services – Safety

requirements




Lampes à fluorescence à ballast intégré pour l'éclairage général – Règles

de sécurité
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.140.30 ISBN 978-2-8322-2244-7



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 60968:2015
– 2 – IEC 60968:2015 © IEC 2015
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references. 6
3 Terms and definitions . 7
4 General requirements and general test requirements . 8
5 Marking . 8
5.1 Lamp marking . 8
5.2 Additional marking . 8
5.3 Compliance of marking . 9
5.4 Locations where marking is required (See Table 1) . 10
6 Interchangeability, mass and bending moment . 10
6.1 Interchangeability . 10
6.2 Bending moment and mass imparted by the lamp at the lampholder . 10
7 Protection against electric shock . 12
8 Insulation resistance and electric strength . 13
8.1 General . 13
8.2 Insulation resistance . 13
8.3 Electric strength . 13
9 Mechanical strength . 13
9.1 General . 13
9.2 Torsion resistance . 14
9.2.1 Torsion resistance of unused lamps . 14
9.2.2 Torsion resistance of lamps after a defined time of usage . 16
9.3 Axial strength of Edison caps . 16
10 Cap temperature rise . 17
11 Resistance to heat . 18
12 Resistance to flame and ignition. 19
13 Fault conditions . 20
13.1 General requirements . 20
13.2 Test conditions . 20
13.3 Test setup for non-starting lamp . 21
14 Creepage distances and clearances . 21
15 Lamp end of life . 21
15.1 General requirements . 21
15.2 Test setup . 21
15.3 Compliance . 22
16 Photobiological safety . 22
16.1 UV radiation . 22
16.2 Other photobiological effects . 22
17 Abnormal operation . 22
18 Test conditions for dimmable and three-way lamps . 23
19 Whole production assessment . 24
20 Collation of type test verification . 24
21 Information for luminaire design . 25

---------------------- Page: 8 ----------------------

SIST EN 60968:2015
IEC 60968:2015 © IEC 2015 – 3 –
Annex A (informative) Whole production assessment . 26
A.1 Assessment – General . 26
A.2 Whole production assessment by means of the manufacturer’s records . 26
Annex B (informative) Information for luminaire design . 28
B.1 Water contact . 28
Bibliography . 29

Figure 1 – Dimming not allowed . 9
Figure 2 – Lamp to be used in dry conditions or in a luminaire that provides protection . 9
Figure 3 – Sample test arrangement for bending moment imparted by the lamp at the
lampholder . 11
Figure 4 – Standard test finger (according to IEC 60529) . 12
Figure 5 – Holder for torsion test on lamps with screw caps . 15
Figure 6 – Holder for torsion test on lamps with bayonet caps . 15
Figure 7 – Test equipment for applying an axial force . 17
Figure 8 – Ball-pressure apparatus . 18
Figure 9 – Schematic diagram for non-starting lamp test . 21
Figure 10 – Test circuit for testing a non-dimmable lamp at a dimmer or electronic
switch . 23

Table 1 – Locations where marking is required . 10
Table 2 – Bending moments and masses . 11
Table 3 – Torsion test values for unused lamps . 16
Table 4 – Values for axial force . 17
Table 5 – Maximum cap temperature rise . 18
Table 6 – Sampling sizes for type test . 24
Table A.1 – Production assessment . 26

---------------------- Page: 9 ----------------------

SIST EN 60968:2015
– 4 – IEC 60968:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

SELF-BALLASTED FLUORESCENT LAMPS
FOR GENERAL LIGHTING SERVICES –
SAFETY REQUIREMENTS

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60968 has been prepared by subcommittee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
This third edition cancels and replaces the second edition published in 2012. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition, where additions have been made to the following:
a) caps and prevention of cap misuse;
b) interchangeability;
c) mechanical and electrical strength;
d) creepage distances and clearances;
e) end of lamp life precaution;
f) abnormal operation;

---------------------- Page: 10 ----------------------

SIST EN 60968:2015
IEC 60968:2015 © IEC 2015 – 5 –
g) test conditions for dimmable and three-way lamps;
h) water contact related marking;
i) verification, and assessment;
j) information for luminaire design in the form of annexes.
The text of this third edition is based on the following documents:
FDIS Report on voting
34A/1811/FDIS 34A/1838/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of March 2015 have been included in this copy.

---------------------- Page: 11 ----------------------

SIST EN 60968:2015
– 6 – IEC 60968:2015 © IEC 2015
SELF-BALLASTED FLUORESCENT LAMPS
FOR GENERAL LIGHTING SERVICES –
SAFETY REQUIREMENTS



1 Scope
This International Standard specifies the safety and interchangeability requirements, together
with the test methods and conditions required to show compliance of tubular fluorescent
lamps with integrated means for controlling starting and stable operation (self-ballasted
fluorescent lamps).
These lamps are intended for domestic and similar general lighting purposes, having a rated
voltage of 50 V to 250 V, having a rated frequency of 50 Hz or 60Hz and having IEC 60061-1
compliant caps.
For a cap-holder system not specifically mentioned in this standard, the relevant information
on safety related tests provided by the manufacturer will apply.
The requirements of this standard relate only to type testing.
Recommendations for whole product testing or batch testing are given in Annex A.
This part of the standard covers photobiological safety according to IEC 62471 and
IEC TR 62471-2. Blue light and infrared hazards are below the level which requires marking.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60061-1, Lamp caps and holders together with gauges for the control of
interchangeability and safety – Part 1: Lamp caps
IEC 60061-3, Lamp caps and holders together with gauges for the control of
interchangeability and safety – Part 3: Gauges
IEC 60360, Standard method of measurement of lamp cap temperature rise
IEC 60598-1, Luminaires – Part 1: General requirements and tests
IEC 60695-2-10, Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-
wire apparatus and common test procedure
IEC 60695-2-11:2000, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods –
Glow-wire flammability test method for end products
IEC 60901, Single-capped fluorescent lamps – Performance specifications
IEC 61199, Single-capped fluorescent lamps – Safety specifications

---------------------- Page: 12 ----------------------

SIST EN 60968:2015
IEC 60968:2015 © IEC 2015 – 7 –
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
ISO 4046-4:2002, Paper, board, pulp and related terms – Vocabulary – Part 4: Paper and
board grades and converted products
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply:
3.1
self-ballasted lamp
unit which cannot be dismantled without being permanently damaged, provided with a lamp
cap and incorporating a light source and any additional elements necessary for starting and
stable operation of the light source
3.2
nominal value
approximate quantity value used to designate or identify a lamp
[SOURCE: IEC 60901:1997, 1.4.3]
3.3
rated value
quantity value for a characteristic of a lamp for specified operating conditions
Note 1 to entry: The value and the conditions are specified in this standard, or assigned by the manufacturer or
responsible vendor.
[SOURCE: IEC 60901:1997, 1.4.4, modified — The second sentence is moved to a note to
entry.]
3.4
cap temperature rise
∆t
s
surface temperature rise (above ambient) of a standard test lampholder fitted to the lamp’s
cap, when measured in accordance with the standard method described in IEC 60360
[SOURCE: IEC 60432-1:1999, 1.3.8
3.5
live part
conductive part which may cause an electric shock in normal use
3.6
type test
test or series of tests made on a type test sample for the purpose of checking compliance of
the design of a given product with the requirements of the relevant standard
3.7
type test sample
sample consisting of one or more similar units submitted by the manufacturer or responsible
vendor for the purpose of the type test
3.8
specific effective radiant UV power
effective power of the UV radiation of a lamp related to its luminous flux

---------------------- Page: 13 ----------------------

SIST EN 60968:2015
– 8 – IEC 60968:2015 © IEC 2015
Note 1 to entry: The specific effective radiant UV power is expressed in mW/klm.
Note 2 to entry: The effective power of the UV radiation is obtained by weighting the spectral power distribution of
the lamp with the UV hazard function S (λ). Information about the relevant UV hazard function is given in
UV
IEC 62471. It only relates to possible hazards regarding UV exposure of human beings. It does not deal with the
possible influence of optical radiation on materials, like mechanical damage or discoloration.
3.9
test family
lamp groups which are distinguished by common features of materials relevant to the test
applied
4 General requirements and general test requirements
4.1 Self-ballasted lamps shall be so designed and constructed that in normal use they
function reliably and cause no danger to the user or surroundings.
In general, compliance is checked by carrying out all the tests specified.
4.2 All measurements unless otherwise specified in this standard, shall be carried out at
rated voltage and frequency and in a draught-proof room. The ambient temperature shall be
from 23 °C to 27 °C inclusive and shall not vary by more than 1 °C during the measurements.
If lamps are rated for alternative frequencies the test shall be carried out at the most onerous
of these.
The test voltages are specified in the relevant clauses.
4.3 Self-ballasted lamps are non-repairable, factory sealed units. They shall not be opened
for any tests with exemption of 13.2. In the case of substantiated doubt based on the
inspection of the lamp and the examination of the circuit diagram, and in agreement with the
manufacturer or responsible vendor, lamps specially prepared so that a fault condition can be
simulated shall be submitted for testing (see Clause 13 and Clause 15).
5 Marking
5.1 Lamp marking
The following information shall be marked on the lamp.
1) Mark of origin (this may take the form of a trademark, the manufacturer's name or the
name of the responsible vendor).
2) Rated voltage(s) or rated voltage range (marked "V" or "volts").
3) Rated power (marked "W" or "watts").
4) Rated frequency (frequencies) (marked in "Hz").
5) Any further information needed to identify the product type e.g. model number or type
reference.
5.2 Additional marking
In addition the following information shall be given by the lamp manufacturer either on the
lamp, the packaging or in the installation instructions.
1) Rated lamp current.
2) For lamps with a weight significantly higher than that of the lamps for which they are a
replacement, attention should be drawn to the fact that the increased weight may reduce
the mechanical stability of certain luminaires.

---------------------- Page: 14 ----------------------

SIST EN 60968:2015
IEC 60968:2015 © IEC 2015 – 9 –
3) Lamps that are not suitable for dimming shall be marked according to Figure 1 or be
provided with a written cautionary notice. The marking shall be provided on the packaging
or accompanying information and its height shall be at least 5 mm.
IEC

Figure 1 – Dimming not allowed
4) Lamps shall be marked with the symbol according to Figure 2. The marking shall be
provided on the packaging or accompanying information. The symbol is not needed if a
written cautionary notice is provided.


...

Questions, Comments and Discussion