Guidelines for the simplified design of structural reinforced concrete for buildings

This International Standard applies to the planning, design and construction of structural reinforced concrete structures to be used in new low-rise buildings with restricted occupancy, number of stories, and area. The purpose of this International Standard is to provide a registered civil engineer or architect with sufficient information to design the reinforced-concrete structural framing of a low-rise building that complies with these limitations; see 6.1. The rules of design as set forth in the present document are simplifications of the more elaborate requirements.
This document may be used as an alternative to the development of a national concrete building code, or equivalent document, in countries where no national design codes themselves are available, or as an alternative to the national concrete building code in countries where it is specifically considered and accepted by the national standard body or other appropriate regulatory organization.
Although the provisions contained in this document were established to produce, when properly employed, a reinforced concrete structure with an appropriate margin of safety, this International Standard is not a substitute for sound and experienced engineering. In order for the resulting structure designed in accordance with these provisions to attain the intended margin of safety, the document must be used as a whole, and alternative procedures should be employed only when explicitly permitted by the provisions. The minimum dimensional provisions as prescribed in the document replace, in most cases, more elaborate procedures such as those prescribed in the national building code, and an eventual economic impact is realized from the simplicity of the procedures prescribed.
The professional performing the structural design in accordance with this International Standard should meet the legal requirements for structural designers in the country of adoption and have training and a minimum of appropriate knowledge of structural mechanics, statics, strength of materials, structural analysis, and reinforced concrete design and construction.

Lignes directrices pour la conception simplifiée du béton armé pour les structures de bâtiments

Smernice za poenostavljeno projektiranje armirano betonskih konstrukcij stavb

Ta mednarodni standard velja za načrtovanje, projektiranje in gradnjo armiranobetonskih konstrukcij, ki se uporabljajo pri novih nizkih stavbah z omejeno zasedenostjo, številom nadstropij in površino. Namen tega mednarodnega standarda je registriranemu gradbenemu inženirju ali arhitektu zagotoviti dovolj informacij za projektiranje armiranobetonskega konstrukcijskega ogrodja nizke stavbe, ki ustreza navedenim omejitvam; glej točko 6.1. Pravila projektiranja, kot jih določa ta dokument, so poenostavitve podrobnejših zahtev.
Ta dokument se lahko uporablja kot alternativa pripravi nacionalnih predpisov za betonsko gradnjo ali enakovrednega dokumenta v državah, kjer nacionalni predpisi za projektiranje niso na voljo, ali kot alternativa nacionalnim predpisom za betonsko gradnjo v državah, kjer ga posebej obravnava in sprejme organ za nacionalne standarde ali druga ustrezna regulatorna organizacija.
Čeprav so bile določbe v tem dokumentu, če se primerno uporabljajo, vzpostavljene za izvedbo armiranobetonske konstrukcije z ustrezno mejo varnosti, ta mednarodni standard ni nadomestek za preudarno in izkušeno gradbeništvo. Da bi bila konstrukcija pojektirana v skladu s temi določbami in da bi dosegla nameravano mejo varnosti, se mora dokument uporabljati v celoti, alternativni postopki pa se lahko uporabljajo le, če to izrecno dovoljujejo določbe. Minimalne dimenzijske določbe, kot jih predpisuje dokument, večinoma nadomeščajo podrobnejše postopke, kot so postopki, ki jih predpisujejo nacionalni gradbeni predpisi, morebitni gospodarski učinek pa je posledica preprostosti predpisanih postopkov.
Strokovnjak, ki izvaja konstrukcijsko projektiranje v skladu s tem mednarodnim standardom, mora izpolnjevati zakonske zahteve za konstrukcijske projektante v državi sprejetja in mora biti usposobljen in imeti minimalno ustrezno znanje iz konstrukcijske mehanike, statike, trdnosti materialov, konstrukcijske analize ter projektiranja in gradnje iz armiranega betona.

General Information

Status
Withdrawn
Public Enquiry End Date
27-Feb-2011
Publication Date
12-Apr-2011
Withdrawal Date
03-Jun-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
04-Jun-2018
Due Date
27-Jun-2018
Completion Date
04-Jun-2018

Relations

Buy Standard

Standard
ISO 15673:2005 - Guidelines for the simplified design of structural reinforced concrete for buildings
English language
172 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 15673:2011
English language
177 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 15673:2011
English language
177 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 15673
First edition
2005-07-15

Guidelines for the simplified design of
structural reinforced concrete for
buildings
Lignes directrices pour la conception simplifiée du béton armé pour
les structures de bâtiments




Reference number
ISO 15673:2005(E)
©
ISO 2005

---------------------- Page: 1 ----------------------
ISO 15673:2005(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2005 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 15673:2005(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 Symbols and abbreviated terms . 12
4.1 Symbols . 12
4.2 Abbreviated terms . 17
5 Design and construction procedure. 18
5.1 Procedure . 18
5.2 Design documentation . 20
6 General provisions . 20
6.1 Limitations. 20
6.2 Limit states . 22
6.3 Ultimate limit state design format. 22
6.4 Serviceability limit state design format. 24
7 Specific provisions. 24
7.1 Structural systems and layout . 24
7.2 Actions (loads) . 29
7.3 General reinforced concrete requirements. 31
7.4 Floor system. 69
7.5 Solid slabs supported on girders, beams, joists or structural concrete walls . 79
7.6 Girders, beams and joists. 106
7.7 Columns. 131
7.8 Lateral force resistance . 143
7.9 Structural concrete walls . 157
7.10 Foundations . 165
Annex A (normative) Equivalent equations for material factors. 168

© ISO 2005 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 15673:2005(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 15673 was prepared by Technical Committee ISO/TC 71, Concrete, reinforced concrete and pre-stressed
concrete, Subcommittee SC 5, Simplified design standard for concrete structures.
iv © ISO 2005 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 15673:2005(E)
Introduction
The aim of this International Standard is to provide rules for the design and construction of low-rise concrete
structures of small floor area to be built in the less developed areas of the world. The document is developed
for countries that do not have existing national standards. This document shall not be used in place of a
national standard unless specifically considered and accepted by the national standard body or other
appropriate regulatory organization. The design rules are based in simplified worldwide-accepted strength
models. The document is self-contained; therefore actions (loads) and simplified analysis procedures are
included, as well as minimum acceptable construction practice guidelines.
The minimum dimensional provisions contained in this document are intended to account for undesirable side
effects that will require more sophisticated analysis and design procedures. Material and construction
provisions are aimed at site-mixed concrete as well as ready-mixed concrete, and steel of the minimum
available strength grades.
The earthquake-resistance provisions are included to account for the fact that numerous underdeveloped
regions of the world occur in earthquake-prone areas. The earthquake resistance is based upon the
employment of structural concrete walls (shear walls) that limit the lateral deformations of the structure and
provide for its lateral strength.
The document contains provisions that can be modified by the national standards body due to local design
and construction requirements and practices. The specifications that can be modified are indicated using
[“boxed values”]. The authorities in each member country are expected to review the “boxed values” and may
substitute alternative definitive values for these elements for use in the national application of the document.
A great effort was made to include self-explanatory tables, graphics, and design aids to simplify the use of the
document and provide foolproof procedures. Notwithstanding, the economic implications of the conservatism
inherent in approximate procedures as a substitution to sound and experienced engineering should be a
matter of concern to the designer who employs the document, and to the owner who hires him.

© ISO 2005 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 15673:2005(E)

Guidelines for the simplified design of structural reinforced
concrete for buildings
1 Scope
This International Standard applies to the planning, design and construction of structural reinforced concrete
structures to be used in new low-rise buildings with restricted occupancy, number of stories, and area. The
purpose of this International Standard is to provide a registered civil engineer or architect with sufficient
information to design the reinforced-concrete structural framing of a low-rise building that complies with these
limitations; see 6.1. The rules of design as set forth in the present document are simplifications of the more
elaborate requirements.
This document may be used as an alternative to the development of a national concrete building code, or
equivalent document, in countries where no national design codes themselves are available, or as an
alternative to the national concrete building code in countries where it is specifically considered and accepted
by the national standard body or other appropriate regulatory organization.
Although the provisions contained in this document were established to produce, when properly employed, a
reinforced concrete structure with an appropriate margin of safety, this International Standard is not a
substitute for sound and experienced engineering. In order for the resulting structure designed in accordance
with these provisions to attain the intended margin of safety, the document must be used as a whole, and
alternative procedures should be employed only when explicitly permitted by the provisions. The minimum
dimensional provisions as prescribed in the document replace, in most cases, more elaborate procedures
such as those prescribed in the national building code, and an eventual economic impact is realized from the
simplicity of the procedures prescribed.
The professional performing the structural design in accordance with this International Standard should meet
the legal requirements for structural designers in the country of adoption and have training and a minimum of
appropriate knowledge of structural mechanics, statics, strength of materials, structural analysis, and
reinforced concrete design and construction.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 679, Methods of testing cements — Determination of strength
ISO 680, Cement — Test methods — Chemical analysis
ISO 863, Cement — Test methods — Pozzolanicity test for pozzolanic cements
ISO 2103, Loads due to use and occupancy in residential and public buildings
ISO 2633, Determination of imposed floor loads in production buildings and warehouses
ISO 3010, Basis for design of structures — Seismic actions on structures
ISO/TR 3956, Principles of structural fire-engineering design with special regard to the connection between
real fire exposure and the heating conditions of the standard fire-resistance test (ISO 834)
© ISO 2005 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 15673:2005(E)
ISO 4354, Wind actions on structures
ISO 4355, Bases for design of structures — Determination of snow loads on roofs
ISO 6274, Concrete — Sieve analysis of aggregates
ISO 6782, Aggregates for concrete — Determination of bulk density
ISO 6783, Coarse aggregates for concrete — Determination of particle density and water absorption —
Hydrostatic balance method
ISO 6935-1, Steel for the reinforcement of concrete — Part 1: Plain bars
ISO 6935-2, Steel for the reinforcement of concrete — Part 2: Ribbed bars
ISO 6935-3:1992, (as amended in 2000), Steel for the reinforcement of concrete — Part 3: Welded fabric
ISO 7033, Fine and coarse aggregates for concrete — Determination of the particle mass-per-volume and
water absorption — Pycnometer method
ISO 9194, Bases for design of structures — Actions due to the self-weight of structures, non-structural
elements and stored materials — Density
ISO 9597, Cements — Test methods — Determination of setting time and soundness
ISO 10144, Certification scheme for steel bars and wires for the reinforcement of concrete structures
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
acceleration of gravity
g
acceleration produced by gravity at the surface of earth
2
NOTE For the purposes of this International Standard, its value can be approximated as g ≈ [10] m/s .
3.2
admixture
material other than water, aggregate, or hydraulic cement, used as an ingredient of concrete and added to
concrete before or during its mixing to modify its properties
3.3
aggregate
granular material, such as sand, gravel, crushed stone, and iron blast-furnace slag, used in conjunction with a
cementing medium to form a hydraulic cement concrete or mortar
3.4
anchorage
device used to anchor a non-structural element to the structural framing
3.5
bar diameter, nominal
approximate diameter of a steel reinforcing bar, often used as a class designation
NOTE The nominal diameter for deformed bars is usually taken as the diameter of a plain bar having the same area.
2 © ISO 2005 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 15673:2005(E)
3.6
base of structure
level at which earthquake motions are assumed to be imparted to a building
NOTE This level does not necessarily coincide with the ground level.
3.7
beam
horizontal, or nearly horizontal, structural member supported at one (such as a cantilever) or more points, but
not throughout its length, transversely supporting a load, and subjected primarily to flexure
3.8
bearing capacity of the soil
maximum permissible stress on the foundation soil that provides adequate safety against bearing failure of the
soil, or settlement of the foundation of such magnitude as to impair the structure
NOTE The value of the bearing capacity of the soil is defined at the working stress level.
3.9
bending moment
product of a force and the distance to a particular axis, producing bending effects in a structural element
3.10
boundary element
portion along a wall edge strengthened by longitudinal and transverse reinforcement
NOTE A boundary element does not necessarily require an increase in thickness of the wall.
3.11
building
structure, usually enclosed by walls and a roof, constructed to provide support or shelter intended for
occupancy
3.12
caisson
foundation pile of large diameter, built partly or totally above ground and sunk below ground usually by digging
out the soil inside
3.13
cement
material as specified in the corresponding referenced International Standards, which, when mixed with water,
has hardening properties, used either in concrete or by itself
3.14
column
vertical member used primarily to support axial compressive loads
3.15
collector element
element that serves to transmit the inertia forces within the diaphragm to members of the lateral-force resisting
system
3.16
combined footing
footing that transmits to the supporting soil the load carried by several columns or structural concrete walls
3.17
compression reinforcement
reinforcement provided to resist compression stresses induced by flexural moments acting on the member
section
© ISO 2005 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 15673:2005(E)
3.18
concrete
mixture of Portland cement and any other hydraulic cement, fine aggregate, coarse aggregate, and water, with
or without admixtures
3.19
concrete mix design
choice and proportioning of the ingredients of concrete
3.20
confinement hook
hook on a stirrup, hoop, or crosstie having a bend of not less than 135° with a six-diameter (but not less than
75 mm) extension that engages the longitudinal reinforcement and projects into the interior of the stirrup or
hoop
3.21
confinement stirrup
tie
closed stirrup, tie or continuously wound spiral
NOTE A closed stirrup or tie can be made up of several reinforcement elements, each having a confinement hook at
both ends. A continuously wound spiral should have a confinement hook at both ends.
3.22
corrosion
gradual removal or weakening of metal from its surface that requires the presence of humidity and oxygen,
and is helped by the presence of other materials
3.23
cover
〈concrete〉 thickness of concrete between the surface of any reinforcing bar and the nearest face of the
concrete member
3.24
crosstie
continuous reinforcing bar having a 135° hook at one end and a hook of not less than 90° at least a
six-diameter extension at the other end
NOTE The hooks normally engage peripheral longitudinal bars. The 90° hooks of two successive crossties engaging
the same longitudinal bars are normally alternated end for end.
3.25
curing
keeping the concrete damp for a period of time, usually several days, starting from the moment it is cast, in
order to provide the cement with enough water to harden and attain the intended strength
NOTE Appropriate curing will greatly reduce shrinkage, increase strength of concrete, and normally reduces surface
cracking. Curing time will depend on the temperature and the relative humidity of the surrounding air, the amount of wind,
the direct sunlight exposure, the type of concrete mix employed, and other factors.
3.26
curtain wall
wall that is part of the façade or enclosure of the building
3.27
deformed reinforcement
steel reinforcement that has deformations in its surface to increase its bond to the concrete
NOTE The following steel reinforcement are normally considered deformed reinforcement under this International
Standard: deformed reinforcing bars, deformed wire, welded plain wire fabric, and welded deformed wire fabric conforming
to the appropriate International Standards.
4 © ISO 2005 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 15673:2005(E)
3.28
depth of member
h
vertical size of a cross-section of a horizontal structural element
3.29
design load combination
combination of factored loads and forces as specified in this International Standard
3.30
design strength
product of the nominal strength multiplied by a strength reduction factor, φ
3.31
development length
length of embedded reinforcement required to develop the design strength of reinforcement at a critical
section
3.32
development length
〈bar with a standard hook〉 the shortest distance between the critical section (where the strength of the bar is
to be developed) and a tangent to the outer edge of the 90° or 180° hook
3.33
differential settlement
movement of the foundation of different parts of a structure by different amounts
3.34
effective depth of section
d
distance measured from the extreme compression fibre to the centroid of tension reinforcement
3.35
embedment length
length of embedded reinforcement provided beyond a critical section
3.36
essential facility
building or other structure that is intended to remain operational in the event of extreme environmental loading
from wind, snow, or earthquakes
3.37
factored load
factored force
specified nominal load or force multiplied by the load factors specified in this International Standard
3.38
fire protection of reinforcement
amount of concrete cover necessary to insulate the reinforcement against the effects of the high temperatures
produced by fire
NOTE The concrete cover is a function of the number of hours of exposure to the fire.
3.39
flange
top or bottom part of an I-shaped section separated by the web
3.40
flexural
pertaining to the flexure bending moment
© ISO 2005 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 15673:2005(E)
3.41
flexural reinforcement
reinforcement provided to resist the tensile stresses induced by flexural moments acting on the member
section
3.42
floor system
structural elements that comprise the floor of a story in a building
NOTE The floor system includes the beams and girders, the joists (if employed), and the slab that spans between
them.
3.43
footing
portion of the foundation that transmits loads directly to the soil
NOTE The footing is often the widened part of a column, a structural concrete wall or several columns, in a combined
footing.
3.44
formwork
temporary construction to contain concrete in a plastic state while it is cast and setting and which forms the
final shape of the element as the concrete hardens
3.45
foundation
any part of the structure that serves to transmit loads to the underlying soil, or to contain it
3.46
foundation beam
beam that rests on the foundation soil and spans between footings, used either to support walls or to limit
differential settlement of the foundation
3.47
foundation mat
continuous slab laid over the ground as part of the foundation and that transmits to the underlying soil the
loads from the structure
3.48
girder
main horizontal support beam, usually supporting other beams
3.49
gravity load
load that acts downward and is caused by the acceleration of gravity, g, acting on the mass of the elements
that causes the dead and live loads
3.50
hook
bend at the end of a reinforcing bar
NOTE Hooks are classified by the angle that the bend forms with the bar as 90°, 135° or 180° hooks.
3.51
joist
T-shaped beam used in parallel series to directly support floor and ceiling loads, and are supported in turn by
larger girders, beams, or bearing structural concrete walls
6 © ISO 2005 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 15673:2005(E)
3.52
lap splice
splice between two reinforcing bars obtained by overlapping them for a specified length
3.53
lateral-force resisting system
that portion of the structure composed of members proportioned to resist loads related to earthquake effects
3.54
lightweight aggregate concrete
concrete made with coarse granular material that weighs less than the granular material used in normal-
weight aggregates
NOTE This type of concrete is not covered in this International Standard.
3.55
limit state
condition beyond which a structure or member becomes unfit for service and is judged either to be no longer
useful for its intended function (serviceability limit state) or to be unsafe (strength limit state)
3.56
live load
load produced by environmental factors or the use and occupancy of the building and do not include
construction or environmental loads
EXAMPLE Wind load, snow load, rain load, earthquake load, flood load, or dead load (without load factors).
3.57
load effect
force and deformation produced in structural members by the applied loads
3.58
load factor
factor that accounts for deviations of the actual load from the nominal load, for uncertainties in the analysis
that transforms the load into a load effect and for the probability that more than one extreme load will occur
simultaneously
3.59
load
force or other action that results from the weight of all building materials, occupants and their possessions,
environmental effects, differential movement, and restrained dimensional changes
3.60
longitudinal reinforcement
reinforcement that is laid parallel to the longitudinal axis of the element, generally to account for flexural
effects
3.61
mass
quantity of matter in a body
3.62
mesh wire
welded-wire fabric reinforcement
3.63
modulus of elasticity
ratio of the normal stress to the corresponding strain for tensile or compressive stresses below the
proportional limit of the material
© ISO 2005 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 15673:2005(E)
3.64
negative moment
flexural moment that produces tension stresses at the upper part of the section of a horizontal, or nearly
horizontal element, and that requires placing negative flexural reinforcement in the upper part of the element
section
3.65
negative reinforcement
flexural reinforcement in horizontal or nearly horizontal elements, required for negative moment and which is
placed in the upper part of the section of the element
3.66
nominal load
magnitude of the load specified in this International Standard (dead, live, soil, wind, snow, rain, flood, and
earthquake)
3.67
nominal strength
capacity of a structure or member to resist the effects of loads, as determined by computations using specified
material strengths and dimensions and the formulas set forth in this International Standard
NOTE The specified material strengths and dimensions in turn are derived from accepted principles of structural
mechanics or by field tests or laboratory tests of scaled models, allowing for modelling effects and differences between
laboratory and field conditions.
3.68
non-structural element
element corresponding to an architectural, a mechanical or an electrical component or system permanently
attached to the building
3.69
occupancy
purpose for which a building or other structure, or part thereof, is used or intended to be used
3.70
partition
non-structural wall that is employed to divide spaces
NOTE A non-structural wall does not support parts of the building other than itself. When it is on the exterior, it is
sometimes referred as a curtain wall.
3.71
pedestal
upright compression member with a ratio of unsupported height to average least lateral dimension of less
than 3
3.72
permanent load
load for which the variations over time are rare or of small magnitude
NOTE All other loads are variable loads (see also nominal loads).
3.73
pile
slender timber, concrete or structural steel element embedded in the ground to support loads
3.74
plain reinforcement
smooth-surfaced steel reinforcement or reinforcement that does not conform to the definition of deformed
reinforcement
8 © ISO 2005 – All rights reserved

---------------------- Page: 13 ----------------------
ISO 15673:2005(E)
3.75
positive moment
flexural moment that produces tension stresses at the lower part of the section of a horizontal or nearly
horizontal element and that requires placing positive flexural reinforcement in the lower part of the element
section
3.76
positive reinforcement
flexural reinforcement in horizontal or nearly horizontal elements required for positive moment and that is
placed in the lower part of the section of the element
3.77
reaction
resistance to a force or load, or upward resistance of a support such as a structural concrete wall or column
against the downward pressure of a loaded member such as a beam
3.78
reinforcement
steel bars, wire, or mesh wire, used for reinforcing the concrete where tensile stresses are expected, due
either to the applied loads or to environmental effects such as variation of temperature
3.79
required factored strength
strength of a member or cross-section required to resist factored loads or related internal moments and forces
in such combinations as are stipulated by this International Standard
3.80
retaining wall
wall built to hold back earth
3.81
selfweight
weight of the structural element, due to the material that composes the element
3.82
service load
load specified by this International Standard (without load factors)
3.83
settlement
downward movement of the supporting soil
3.84
shear
internal force acting tangential to the plane where it acts
NOTE Also called diagonal tension.
3.85
shear reinforcement
reinforcement designed to resist shear
3.86
shores
vertical or
...

SLOVENSKI STANDARD
SIST ISO 15673:2011
01-maj-2011
Smernice za poenostavljeno projektiranje armirano betonskih konstrukcij stavb
Guidelines for the simplified design of structural reinforced concrete for buildings
Lignes directrices pour la conception simplifiée du béton armé pour les structures de
bâtiments
Ta slovenski standard je istoveten z: ISO 15673:2005
ICS:
91.080.40 Betonske konstrukcije Concrete structures
SIST ISO 15673:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 15673:2011

---------------------- Page: 2 ----------------------

SIST ISO 15673:2011

INTERNATIONAL ISO
STANDARD 15673
First edition
2005-07-15

Guidelines for the simplified design of
structural reinforced concrete for
buildings
Lignes directrices pour la conception simplifiée du béton armé pour
les structures de bâtiments




Reference number
ISO 15673:2005(E)
©
ISO 2005

---------------------- Page: 3 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2005 – All rights reserved

---------------------- Page: 4 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 Symbols and abbreviated terms . 12
4.1 Symbols . 12
4.2 Abbreviated terms . 17
5 Design and construction procedure. 18
5.1 Procedure . 18
5.2 Design documentation . 20
6 General provisions . 20
6.1 Limitations. 20
6.2 Limit states . 22
6.3 Ultimate limit state design format. 22
6.4 Serviceability limit state design format. 24
7 Specific provisions. 24
7.1 Structural systems and layout . 24
7.2 Actions (loads) . 29
7.3 General reinforced concrete requirements. 31
7.4 Floor system. 69
7.5 Solid slabs supported on girders, beams, joists or structural concrete walls . 79
7.6 Girders, beams and joists. 106
7.7 Columns. 131
7.8 Lateral force resistance . 143
7.9 Structural concrete walls . 157
7.10 Foundations . 165
Annex A (normative) Equivalent equations for material factors. 168

© ISO 2005 – All rights reserved iii

---------------------- Page: 5 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 15673 was prepared by Technical Committee ISO/TC 71, Concrete, reinforced concrete and pre-stressed
concrete, Subcommittee SC 5, Simplified design standard for concrete structures.
iv © ISO 2005 – All rights reserved

---------------------- Page: 6 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
Introduction
The aim of this International Standard is to provide rules for the design and construction of low-rise concrete
structures of small floor area to be built in the less developed areas of the world. The document is developed
for countries that do not have existing national standards. This document shall not be used in place of a
national standard unless specifically considered and accepted by the national standard body or other
appropriate regulatory organization. The design rules are based in simplified worldwide-accepted strength
models. The document is self-contained; therefore actions (loads) and simplified analysis procedures are
included, as well as minimum acceptable construction practice guidelines.
The minimum dimensional provisions contained in this document are intended to account for undesirable side
effects that will require more sophisticated analysis and design procedures. Material and construction
provisions are aimed at site-mixed concrete as well as ready-mixed concrete, and steel of the minimum
available strength grades.
The earthquake-resistance provisions are included to account for the fact that numerous underdeveloped
regions of the world occur in earthquake-prone areas. The earthquake resistance is based upon the
employment of structural concrete walls (shear walls) that limit the lateral deformations of the structure and
provide for its lateral strength.
The document contains provisions that can be modified by the national standards body due to local design
and construction requirements and practices. The specifications that can be modified are indicated using
[“boxed values”]. The authorities in each member country are expected to review the “boxed values” and may
substitute alternative definitive values for these elements for use in the national application of the document.
A great effort was made to include self-explanatory tables, graphics, and design aids to simplify the use of the
document and provide foolproof procedures. Notwithstanding, the economic implications of the conservatism
inherent in approximate procedures as a substitution to sound and experienced engineering should be a
matter of concern to the designer who employs the document, and to the owner who hires him.

© ISO 2005 – All rights reserved v

---------------------- Page: 7 ----------------------

SIST ISO 15673:2011

---------------------- Page: 8 ----------------------

SIST ISO 15673:2011
INTERNATIONAL STANDARD ISO 15673:2005(E)

Guidelines for the simplified design of structural reinforced
concrete for buildings
1 Scope
This International Standard applies to the planning, design and construction of structural reinforced concrete
structures to be used in new low-rise buildings with restricted occupancy, number of stories, and area. The
purpose of this International Standard is to provide a registered civil engineer or architect with sufficient
information to design the reinforced-concrete structural framing of a low-rise building that complies with these
limitations; see 6.1. The rules of design as set forth in the present document are simplifications of the more
elaborate requirements.
This document may be used as an alternative to the development of a national concrete building code, or
equivalent document, in countries where no national design codes themselves are available, or as an
alternative to the national concrete building code in countries where it is specifically considered and accepted
by the national standard body or other appropriate regulatory organization.
Although the provisions contained in this document were established to produce, when properly employed, a
reinforced concrete structure with an appropriate margin of safety, this International Standard is not a
substitute for sound and experienced engineering. In order for the resulting structure designed in accordance
with these provisions to attain the intended margin of safety, the document must be used as a whole, and
alternative procedures should be employed only when explicitly permitted by the provisions. The minimum
dimensional provisions as prescribed in the document replace, in most cases, more elaborate procedures
such as those prescribed in the national building code, and an eventual economic impact is realized from the
simplicity of the procedures prescribed.
The professional performing the structural design in accordance with this International Standard should meet
the legal requirements for structural designers in the country of adoption and have training and a minimum of
appropriate knowledge of structural mechanics, statics, strength of materials, structural analysis, and
reinforced concrete design and construction.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 679, Methods of testing cements — Determination of strength
ISO 680, Cement — Test methods — Chemical analysis
ISO 863, Cement — Test methods — Pozzolanicity test for pozzolanic cements
ISO 2103, Loads due to use and occupancy in residential and public buildings
ISO 2633, Determination of imposed floor loads in production buildings and warehouses
ISO 3010, Basis for design of structures — Seismic actions on structures
ISO/TR 3956, Principles of structural fire-engineering design with special regard to the connection between
real fire exposure and the heating conditions of the standard fire-resistance test (ISO 834)
© ISO 2005 – All rights reserved 1

---------------------- Page: 9 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
ISO 4354, Wind actions on structures
ISO 4355, Bases for design of structures — Determination of snow loads on roofs
ISO 6274, Concrete — Sieve analysis of aggregates
ISO 6782, Aggregates for concrete — Determination of bulk density
ISO 6783, Coarse aggregates for concrete — Determination of particle density and water absorption —
Hydrostatic balance method
ISO 6935-1, Steel for the reinforcement of concrete — Part 1: Plain bars
ISO 6935-2, Steel for the reinforcement of concrete — Part 2: Ribbed bars
ISO 6935-3:1992, (as amended in 2000), Steel for the reinforcement of concrete — Part 3: Welded fabric
ISO 7033, Fine and coarse aggregates for concrete — Determination of the particle mass-per-volume and
water absorption — Pycnometer method
ISO 9194, Bases for design of structures — Actions due to the self-weight of structures, non-structural
elements and stored materials — Density
ISO 9597, Cements — Test methods — Determination of setting time and soundness
ISO 10144, Certification scheme for steel bars and wires for the reinforcement of concrete structures
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
acceleration of gravity
g
acceleration produced by gravity at the surface of earth
2
NOTE For the purposes of this International Standard, its value can be approximated as g ≈ [10] m/s .
3.2
admixture
material other than water, aggregate, or hydraulic cement, used as an ingredient of concrete and added to
concrete before or during its mixing to modify its properties
3.3
aggregate
granular material, such as sand, gravel, crushed stone, and iron blast-furnace slag, used in conjunction with a
cementing medium to form a hydraulic cement concrete or mortar
3.4
anchorage
device used to anchor a non-structural element to the structural framing
3.5
bar diameter, nominal
approximate diameter of a steel reinforcing bar, often used as a class designation
NOTE The nominal diameter for deformed bars is usually taken as the diameter of a plain bar having the same area.
2 © ISO 2005 – All rights reserved

---------------------- Page: 10 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.6
base of structure
level at which earthquake motions are assumed to be imparted to a building
NOTE This level does not necessarily coincide with the ground level.
3.7
beam
horizontal, or nearly horizontal, structural member supported at one (such as a cantilever) or more points, but
not throughout its length, transversely supporting a load, and subjected primarily to flexure
3.8
bearing capacity of the soil
maximum permissible stress on the foundation soil that provides adequate safety against bearing failure of the
soil, or settlement of the foundation of such magnitude as to impair the structure
NOTE The value of the bearing capacity of the soil is defined at the working stress level.
3.9
bending moment
product of a force and the distance to a particular axis, producing bending effects in a structural element
3.10
boundary element
portion along a wall edge strengthened by longitudinal and transverse reinforcement
NOTE A boundary element does not necessarily require an increase in thickness of the wall.
3.11
building
structure, usually enclosed by walls and a roof, constructed to provide support or shelter intended for
occupancy
3.12
caisson
foundation pile of large diameter, built partly or totally above ground and sunk below ground usually by digging
out the soil inside
3.13
cement
material as specified in the corresponding referenced International Standards, which, when mixed with water,
has hardening properties, used either in concrete or by itself
3.14
column
vertical member used primarily to support axial compressive loads
3.15
collector element
element that serves to transmit the inertia forces within the diaphragm to members of the lateral-force resisting
system
3.16
combined footing
footing that transmits to the supporting soil the load carried by several columns or structural concrete walls
3.17
compression reinforcement
reinforcement provided to resist compression stresses induced by flexural moments acting on the member
section
© ISO 2005 – All rights reserved 3

---------------------- Page: 11 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.18
concrete
mixture of Portland cement and any other hydraulic cement, fine aggregate, coarse aggregate, and water, with
or without admixtures
3.19
concrete mix design
choice and proportioning of the ingredients of concrete
3.20
confinement hook
hook on a stirrup, hoop, or crosstie having a bend of not less than 135° with a six-diameter (but not less than
75 mm) extension that engages the longitudinal reinforcement and projects into the interior of the stirrup or
hoop
3.21
confinement stirrup
tie
closed stirrup, tie or continuously wound spiral
NOTE A closed stirrup or tie can be made up of several reinforcement elements, each having a confinement hook at
both ends. A continuously wound spiral should have a confinement hook at both ends.
3.22
corrosion
gradual removal or weakening of metal from its surface that requires the presence of humidity and oxygen,
and is helped by the presence of other materials
3.23
cover
〈concrete〉 thickness of concrete between the surface of any reinforcing bar and the nearest face of the
concrete member
3.24
crosstie
continuous reinforcing bar having a 135° hook at one end and a hook of not less than 90° at least a
six-diameter extension at the other end
NOTE The hooks normally engage peripheral longitudinal bars. The 90° hooks of two successive crossties engaging
the same longitudinal bars are normally alternated end for end.
3.25
curing
keeping the concrete damp for a period of time, usually several days, starting from the moment it is cast, in
order to provide the cement with enough water to harden and attain the intended strength
NOTE Appropriate curing will greatly reduce shrinkage, increase strength of concrete, and normally reduces surface
cracking. Curing time will depend on the temperature and the relative humidity of the surrounding air, the amount of wind,
the direct sunlight exposure, the type of concrete mix employed, and other factors.
3.26
curtain wall
wall that is part of the façade or enclosure of the building
3.27
deformed reinforcement
steel reinforcement that has deformations in its surface to increase its bond to the concrete
NOTE The following steel reinforcement are normally considered deformed reinforcement under this International
Standard: deformed reinforcing bars, deformed wire, welded plain wire fabric, and welded deformed wire fabric conforming
to the appropriate International Standards.
4 © ISO 2005 – All rights reserved

---------------------- Page: 12 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.28
depth of member
h
vertical size of a cross-section of a horizontal structural element
3.29
design load combination
combination of factored loads and forces as specified in this International Standard
3.30
design strength
product of the nominal strength multiplied by a strength reduction factor, φ
3.31
development length
length of embedded reinforcement required to develop the design strength of reinforcement at a critical
section
3.32
development length
〈bar with a standard hook〉 the shortest distance between the critical section (where the strength of the bar is
to be developed) and a tangent to the outer edge of the 90° or 180° hook
3.33
differential settlement
movement of the foundation of different parts of a structure by different amounts
3.34
effective depth of section
d
distance measured from the extreme compression fibre to the centroid of tension reinforcement
3.35
embedment length
length of embedded reinforcement provided beyond a critical section
3.36
essential facility
building or other structure that is intended to remain operational in the event of extreme environmental loading
from wind, snow, or earthquakes
3.37
factored load
factored force
specified nominal load or force multiplied by the load factors specified in this International Standard
3.38
fire protection of reinforcement
amount of concrete cover necessary to insulate the reinforcement against the effects of the high temperatures
produced by fire
NOTE The concrete cover is a function of the number of hours of exposure to the fire.
3.39
flange
top or bottom part of an I-shaped section separated by the web
3.40
flexural
pertaining to the flexure bending moment
© ISO 2005 – All rights reserved 5

---------------------- Page: 13 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.41
flexural reinforcement
reinforcement provided to resist the tensile stresses induced by flexural moments acting on the member
section
3.42
floor system
structural elements that comprise the floor of a story in a building
NOTE The floor system includes the beams and girders, the joists (if employed), and the slab that spans between
them.
3.43
footing
portion of the foundation that transmits loads directly to the soil
NOTE The footing is often the widened part of a column, a structural concrete wall or several columns, in a combined
footing.
3.44
formwork
temporary construction to contain concrete in a plastic state while it is cast and setting and which forms the
final shape of the element as the concrete hardens
3.45
foundation
any part of the structure that serves to transmit loads to the underlying soil, or to contain it
3.46
foundation beam
beam that rests on the foundation soil and spans between footings, used either to support walls or to limit
differential settlement of the foundation
3.47
foundation mat
continuous slab laid over the ground as part of the foundation and that transmits to the underlying soil the
loads from the structure
3.48
girder
main horizontal support beam, usually supporting other beams
3.49
gravity load
load that acts downward and is caused by the acceleration of gravity, g, acting on the mass of the elements
that causes the dead and live loads
3.50
hook
bend at the end of a reinforcing bar
NOTE Hooks are classified by the angle that the bend forms with the bar as 90°, 135° or 180° hooks.
3.51
joist
T-shaped beam used in parallel series to directly support floor and ceiling loads, and are supported in turn by
larger girders, beams, or bearing structural concrete walls
6 © ISO 2005 – All rights reserved

---------------------- Page: 14 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.52
lap splice
splice between two reinforcing bars obtained by overlapping them for a specified length
3.53
lateral-force resisting system
that portion of the structure composed of members proportioned to resist loads related to earthquake effects
3.54
lightweight aggregate concrete
concrete made with coarse granular material that weighs less than the granular material used in normal-
weight aggregates
NOTE This type of concrete is not covered in this International Standard.
3.55
limit state
condition beyond which a structure or member becomes unfit for service and is judged either to be no longer
useful for its intended function (serviceability limit state) or to be unsafe (strength limit state)
3.56
live load
load produced by environmental factors or the use and occupancy of the building and do not include
construction or environmental loads
EXAMPLE Wind load, snow load, rain load, earthquake load, flood load, or dead load (without load factors).
3.57
load effect
force and deformation produced in structural members by the applied loads
3.58
load factor
factor that accounts for deviations of the actual load from the nominal load, for uncertainties in the analysis
that transforms the load into a load effect and for the probability that more than one extreme load will occur
simultaneously
3.59
load
force or other action that results from the weight of all building materials, occupants and their possessions,
environmental effects, differential movement, and restrained dimensional changes
3.60
longitudinal reinforcement
reinforcement that is laid parallel to the longitudinal axis of the element, generally to account for flexural
effects
3.61
mass
quantity of matter in a body
3.62
mesh wire
welded-wire fabric reinforcement
3.63
modulus of elasticity
ratio of the normal stress to the corresponding strain for tensile or compressive stresses below the
proportional limit of the material
© ISO 2005 – All rights reserved 7

---------------------- Page: 15 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.64
negative moment
flexural moment that produces tension stresses at the upper part of the section of a horizontal, or nearly
horizontal element, and that requires placing negative flexural reinforcement in the upper part of the element
section
3.65
negative reinforcement
flexural reinforcement in horizontal or nearly horizontal elements, required for negative moment and which is
placed in the upper part of the section of the element
3.66
nominal load
magnitude of the load specified in this International Standard (dead, live, soil, wind, snow, rain, flood, and
earthquake)
3.67
nominal strength
capacity of a structure or member to resist the effects of loads, as determined by computations using specified
material strengths and dimensions and the formulas set forth in this International Standard
NOTE The specified material strengths and dimensions in turn are derived from accepted principles of structural
mechanics or by field tests or laboratory tests of scaled models, allowing for modelling effects and differences between
laboratory and field conditions.
3.68
non-structural element
element corresponding to an architectural, a mechanical or an electrical component or system permanently
attached to the building
3.69
occupancy
purpose for which a building or other structure, or part thereof, is used or intended to be used
3.70
partition
non-structural wall that is employed to divide spaces
NOTE A non-structural wall does not support parts of the building other than itself. When it is on the exterior, it is
sometimes referred as a curtain wall.
3.71
pedestal
upright compression member with a ratio of unsupported height to average least lateral dimension of less
than 3
3.72
permanent load
load for which the variations over time are rare or of small magnitude
NOTE All other loads are variable loads (see also nominal loads).
3.73
pile
slender timber, concrete or structural steel element embedded in the ground to support loads
3.74
plain reinforcement
smooth-surfaced steel reinforcement or reinforcement that does not conform to the definition of deformed
reinforcement
8 © ISO 2005 – All rights reserved

---------------------- Page: 16 ----------------------

SIST ISO 15673:2011
ISO 15673:2005(E)
3.75
positive moment
flexural moment that produces tension stresses at the lower part of the section of a horizontal or nearly
horizontal element and that requires placing positive flexural reinforcement in the lower part of the element
section
3.76
positive reinforcement
flexural reinforcement in horizontal or nearly horizontal elements required for positive moment and that is
placed in the lower part of the section of the element
3.77
reaction
resistance to a force or load, or
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Smernice za poenostavljene ocene konstrukcije armiranih betonskih stavbLignes directrices pour la conception simplifiée du béton armé pour les structures de bâtimentsGuidelines for the simplified design of structural reinforced concrete for buildings91.080.40Betonske konstrukcijeConcrete structuresICS:Ta slovenski standard je istoveten z:ISO 15673:2005oSIST ISO 15673:2011en01-februar-2011oSIST ISO 15673:2011SLOVENSKI
STANDARD



oSIST ISO 15673:2011



Reference numberISO 15673:2005(E)© ISO 2005
INTERNATIONAL STANDARD ISO15673First edition2005-07-15Guidelines for the simplified design of structural reinforced concrete for buildings Lignes directrices pour la conception simplifiée du béton armé pour les structures de bâtiments
oSIST ISO 15673:2011



ISO 15673:2005(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
©
ISO 2005 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 • CH-1211 Geneva 20 Tel.
+ 41 22 749 01 11 Fax
+ 41 22 749 09 47 E-mail
copyright@iso.org Web
www.iso.org Published in Switzerland
ii © ISO 2005 – All rights reserved
oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved iiiContents Page Foreword.iv Introduction.v 1 Scope.1 2 Normative references.1 3 Terms and definitions.2 4 Symbols and abbreviated terms.12 4.1 Symbols.12 4.2 Abbreviated terms.17 5 Design and construction procedure.18 5.1 Procedure.18 5.2 Design documentation.20 6 General provisions.20 6.1 Limitations.20 6.2 Limit states.22 6.3 Ultimate limit state design format.22 6.4 Serviceability limit state design format.24 7 Specific provisions.24 7.1 Structural systems and layout.24 7.2 Actions (loads).29 7.3 General reinforced concrete requirements.31 7.4 Floor system.69 7.5 Solid slabs supported on girders, beams, joists or structural concrete walls.79 7.6 Girders, beams and joists.106 7.7 Columns.131 7.8 Lateral force resistance.143 7.9 Structural concrete walls.157 7.10 Foundations.165 Annex A (normative)
Equivalent equations for material factors.168
oSIST ISO 15673:2011



ISO 15673:2005(E) iv © ISO 2005 – All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 15673 was prepared by Technical Committee ISO/TC 71, Concrete, reinforced concrete and pre-stressed concrete, Subcommittee SC 5, Simplified design standard for concrete structures. oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved vIntroduction The aim of this International Standard is to provide rules for the design and construction of low-rise concrete structures of small floor area to be built in the less developed areas of the world. The document is developed for countries that do not have existing national standards. This document shall not be used in place of a national standard unless specifically considered and accepted by the national standard body or other appropriate regulatory organization. The design rules are based in simplified worldwide-accepted strength models. The document is self-contained; therefore actions (loads) and simplified analysis procedures are included, as well as minimum acceptable construction practice guidelines. The minimum dimensional provisions contained in this document are intended to account for undesirable side effects that will require more sophisticated analysis and design procedures. Material and construction provisions are aimed at site-mixed concrete as well as ready-mixed concrete, and steel of the minimum available strength grades. The earthquake-resistance provisions are included to account for the fact that numerous underdeveloped regions of the world occur in earthquake-prone areas. The earthquake resistance is based upon the employment of structural concrete walls (shear walls) that limit the lateral deformations of the structure and provide for its lateral strength. The document contains provisions that can be modified by the national standards body due to local design and construction requirements and practices. The specifications that can be modified are indicated using [“boxed values”]. The authorities in each member country are expected to review the “boxed values” and may substitute alternative definitive values for these elements for use in the national application of the document. A great effort was made to include self-explanatory tables, graphics, and design aids to simplify the use of the document and provide foolproof procedures. Notwithstanding, the economic implications of the conservatism inherent in approximate procedures as a substitution to sound and experienced engineering should be a matter of concern to the designer who employs the document, and to the owner who hires him.
oSIST ISO 15673:2011



oSIST ISO 15673:2011



INTERNATIONAL STANDARD ISO 15673:2005(E) © ISO 2005 – All rights reserved 1 Guidelines for the simplified design of structural reinforced concrete for buildings 1 Scope This International Standard applies to the planning, design and construction of structural reinforced concrete structures to be used in new low-rise buildings with restricted occupancy, number of stories, and area. The purpose of this International Standard is to provide a registered civil engineer or architect with sufficient information to design the reinforced-concrete structural framing of a low-rise building that complies with these limitations; see 6.1. The rules of design as set forth in the present document are simplifications of the more elaborate requirements. This document may be used as an alternative to the development of a national concrete building code, or equivalent document, in countries where no national design codes themselves are available, or as an alternative to the national concrete building code in countries where it is specifically considered and accepted by the national standard body or other appropriate regulatory organization. Although the provisions contained in this document were established to produce, when properly employed, a reinforced concrete structure with an appropriate margin of safety, this International Standard is not a substitute for sound and experienced engineering. In order for the resulting structure designed in accordance with these provisions to attain the intended margin of safety, the document must be used as a whole, and alternative procedures should be employed only when explicitly permitted by the provisions. The minimum dimensional provisions as prescribed in the document replace, in most cases, more elaborate procedures such as those prescribed in the national building code, and an eventual economic impact is realized from the simplicity of the procedures prescribed. The professional performing the structural design in accordance with this International Standard should meet the legal requirements for structural designers in the country of adoption and have training and a minimum of appropriate knowledge of structural mechanics, statics, strength of materials, structural analysis, and reinforced concrete design and construction. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 679, Methods of testing cements — Determination of strength ISO 680, Cement — Test methods — Chemical analysis ISO 863, Cement — Test methods — Pozzolanicity test for pozzolanic cements ISO 2103, Loads due to use and occupancy in residential and public buildings ISO 2633, Determination of imposed floor loads in production buildings and warehouses ISO 3010, Basis for design of structures — Seismic actions on structures ISO/TR 3956, Principles of structural fire-engineering design with special regard to the connection between real fire exposure and the heating conditions of the standard fire-resistance test (ISO 834) oSIST ISO 15673:2011



ISO 15673:2005(E) 2 © ISO 2005 – All rights reserved ISO 4354, Wind actions on structures ISO 4355, Bases for design of structures — Determination of snow loads on roofs ISO 6274, Concrete — Sieve analysis of aggregates ISO 6782, Aggregates for concrete — Determination of bulk density ISO 6783, Coarse aggregates for concrete — Determination of particle density and water absorption — Hydrostatic balance method ISO 6935-1, Steel for the reinforcement of concrete — Part 1: Plain bars ISO 6935-2, Steel for the reinforcement of concrete — Part 2: Ribbed bars ISO 6935-3:1992, (as amended in 2000), Steel for the reinforcement of concrete — Part 3: Welded fabric ISO 7033, Fine and coarse aggregates for concrete — Determination of the particle mass-per-volume and water absorption — Pycnometer method ISO 9194, Bases for design of structures — Actions due to the self-weight of structures, non-structural elements and stored materials — Density ISO 9597, Cements — Test methods — Determination of setting time and soundness ISO 10144, Certification scheme for steel bars and wires for the reinforcement of concrete structures 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 acceleration of gravity g acceleration produced by gravity at the surface of earth NOTE For the purposes of this International Standard, its value can be approximated as g ≈ [10] m/s2. 3.2 admixture material other than water, aggregate, or hydraulic cement, used as an ingredient of concrete and added to concrete before or during its mixing to modify its properties 3.3 aggregate granular material, such as sand, gravel, crushed stone, and iron blast-furnace slag, used in conjunction with a cementing medium to form a hydraulic cement concrete or mortar 3.4 anchorage device used to anchor a non-structural element to the structural framing 3.5 bar diameter, nominal approximate diameter of a steel reinforcing bar, often used as a class designation NOTE The nominal diameter for deformed bars is usually taken as the diameter of a plain bar having the same area. oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved 33.6 base of structure level at which earthquake motions are assumed to be imparted to a building NOTE This level does not necessarily coincide with the ground level. 3.7 beam horizontal, or nearly horizontal, structural member supported at one (such as a cantilever) or more points, but not throughout its length, transversely supporting a load, and subjected primarily to flexure 3.8 bearing capacity of the soil maximum permissible stress on the foundation soil that provides adequate safety against bearing failure of the soil, or settlement of the foundation of such magnitude as to impair the structure NOTE The value of the bearing capacity of the soil is defined at the working stress level. 3.9 bending moment product of a force and the distance to a particular axis, producing bending effects in a structural element 3.10 boundary element portion along a wall edge strengthened by longitudinal and transverse reinforcement NOTE A boundary element does not necessarily require an increase in thickness of the wall. 3.11 building structure, usually enclosed by walls and a roof, constructed to provide support or shelter intended for occupancy 3.12 caisson foundation pile of large diameter, built partly or totally above ground and sunk below ground usually by digging out the soil inside 3.13 cement material as specified in the corresponding referenced International Standards, which, when mixed with water, has hardening properties, used either in concrete or by itself 3.14 column vertical member used primarily to support axial compressive loads 3.15 collector element element that serves to transmit the inertia forces within the diaphragm to members of the lateral-force resisting system 3.16 combined footing footing that transmits to the supporting soil the load carried by several columns or structural concrete walls 3.17 compression reinforcement reinforcement provided to resist compression stresses induced by flexural moments acting on the member section oSIST ISO 15673:2011



ISO 15673:2005(E) 4 © ISO 2005 – All rights reserved 3.18 concrete mixture of Portland cement and any other hydraulic cement, fine aggregate, coarse aggregate, and water, with or without admixtures 3.19 concrete mix design choice and proportioning of the ingredients of concrete 3.20 confinement hook hook on a stirrup, hoop, or crosstie having a bend of not less than 135° with a six-diameter (but not less than 75 mm) extension that engages the longitudinal reinforcement and projects into the interior of the stirrup or hoop 3.21 confinement stirrup tie closed stirrup, tie or continuously wound spiral NOTE A closed stirrup or tie can be made up of several reinforcement elements, each having a confinement hook at both ends. A continuously wound spiral should have a confinement hook at both ends. 3.22 corrosion gradual removal or weakening of metal from its surface that requires the presence of humidity and oxygen, and is helped by the presence of other materials 3.23 cover 〈concrete〉 thickness of concrete between the surface of any reinforcing bar and the nearest face of the concrete member 3.24 crosstie continuous reinforcing bar having a 135° hook at one end and a hook of not less than 90° at least a six-diameter extension at the other end NOTE The hooks normally engage peripheral longitudinal bars. The 90° hooks of two successive crossties engaging the same longitudinal bars are normally alternated end for end. 3.25 curing keeping the concrete damp for a period of time, usually several days, starting from the moment it is cast, in order to provide the cement with enough water to harden and attain the intended strength NOTE Appropriate curing will greatly reduce shrinkage, increase strength of concrete, and normally reduces surface cracking. Curing time will depend on the temperature and the relative humidity of the surrounding air, the amount of wind, the direct sunlight exposure, the type of concrete mix employed, and other factors. 3.26 curtain wall wall that is part of the façade or enclosure of the building 3.27 deformed reinforcement steel reinforcement that has deformations in its surface to increase its bond to the concrete NOTE The following steel reinforcement are normally considered deformed reinforcement under this International Standard: deformed reinforcing bars, deformed wire, welded plain wire fabric, and welded deformed wire fabric conforming to the appropriate International Standards. oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved 53.28 depth of member h vertical size of a cross-section of a horizontal structural element 3.29 design load combination combination of factored loads and forces as specified in this International Standard 3.30 design strength product of the nominal strength multiplied by a strength reduction factor, φ 3.31 development length length of embedded reinforcement required to develop the design strength of reinforcement at a critical section 3.32 development length 〈bar with a standard hook〉 the shortest distance between the critical section (where the strength of the bar is to be developed) and a tangent to the outer edge of the 90° or 180° hook 3.33 differential settlement movement of the foundation of different parts of a structure by different amounts 3.34 effective depth of section d distance measured from the extreme compression fibre to the centroid of tension reinforcement 3.35 embedment length length of embedded reinforcement provided beyond a critical section 3.36 essential facility building or other structure that is intended to remain operational in the event of extreme environmental loading from wind, snow, or earthquakes 3.37 factored load factored force specified nominal load or force multiplied by the load factors specified in this International Standard 3.38 fire protection of reinforcement amount of concrete cover necessary to insulate the reinforcement against the effects of the high temperatures produced by fire NOTE The concrete cover is a function of the number of hours of exposure to the fire. 3.39 flange top or bottom part of an I-shaped section separated by the web 3.40 flexural pertaining to the flexure bending moment oSIST ISO 15673:2011



ISO 15673:2005(E) 6 © ISO 2005 – All rights reserved 3.41 flexural reinforcement reinforcement provided to resist the tensile stresses induced by flexural moments acting on the member section 3.42 floor system structural elements that comprise the floor of a story in a building NOTE The floor system includes the beams and girders, the joists (if employed), and the slab that spans between them. 3.43 footing portion of the foundation that transmits loads directly to the soil NOTE The footing is often the widened part of a column, a structural concrete wall or several columns, in a combined footing. 3.44 formwork temporary construction to contain concrete in a plastic state while it is cast and setting and which forms the final shape of the element as the concrete hardens 3.45 foundation any part of the structure that serves to transmit loads to the underlying soil, or to contain it 3.46 foundation beam beam that rests on the foundation soil and spans between footings, used either to support walls or to limit differential settlement of the foundation 3.47 foundation mat continuous slab laid over the ground as part of the foundation and that transmits to the underlying soil the loads from the structure 3.48 girder main horizontal support beam, usually supporting other beams 3.49 gravity load load that acts downward and is caused by the acceleration of gravity, g, acting on the mass of the elements that causes the dead and live loads 3.50 hook bend at the end of a reinforcing bar NOTE Hooks are classified by the angle that the bend forms with the bar as 90°, 135° or 180° hooks. 3.51 joist T-shaped beam used in parallel series to directly support floor and ceiling loads, and are supported in turn by larger girders, beams, or bearing structural concrete walls oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved 73.52 lap splice splice between two reinforcing bars obtained by overlapping them for a specified length 3.53 lateral-force resisting system that portion of the structure composed of members proportioned to resist loads related to earthquake effects 3.54 lightweight aggregate concrete concrete made with coarse granular material that weighs less than the granular material used in normal-weight aggregates NOTE This type of concrete is not covered in this International Standard. 3.55 limit state condition beyond which a structure or member becomes unfit for service and is judged either to be no longer useful for its intended function (serviceability limit state) or to be unsafe (strength limit state) 3.56 live load load produced by environmental factors or the use and occupancy of the building and do not include construction or environmental loads EXAMPLE Wind load, snow load, rain load, earthquake load, flood load, or dead load (without load factors). 3.57 load effect force and deformation produced in structural members by the applied loads 3.58 load factor factor that accounts for deviations of the actual load from the nominal load, for uncertainties in the analysis that transforms the load into a load effect and for the probability that more than one extreme load will occur simultaneously 3.59 load force or other action that results from the weight of all building materials, occupants and their possessions, environmental effects, differential movement, and restrained dimensional changes 3.60 longitudinal reinforcement reinforcement that is laid parallel to the longitudinal axis of the element, generally to account for flexural effects 3.61 mass quantity of matter in a body 3.62 mesh wire welded-wire fabric reinforcement 3.63 modulus of elasticity ratio of the normal stress to the corresponding strain for tensile or compressive stresses below the proportional limit of the material oSIST ISO 15673:2011



ISO 15673:2005(E) 8 © ISO 2005 – All rights reserved 3.64 negative moment flexural moment that produces tension stresses at the upper part of the section of a horizontal, or nearly horizontal element, and that requires placing negative flexural reinforcement in the upper part of the element section 3.65 negative reinforcement flexural reinforcement in horizontal or nearly horizontal elements, required for negative moment and which is placed in the upper part of the section of the element 3.66 nominal load magnitude of the load specified in this International Standard (dead, live, soil, wind, snow, rain, flood, and earthquake) 3.67 nominal strength capacity of a structure or member to resist the effects of loads, as determined by computations using specified material strengths and dimensions and the formulas set forth in this International Standard NOTE The specified material strengths and dimensions in turn are derived from accepted principles of structural mechanics or by field tests or laboratory tests of scaled models, allowing for modelling effects and differences between laboratory and field conditions. 3.68 non-structural element element corresponding to an architectural, a mechanical or an electrical component or system permanently attached to the building 3.69 occupancy purpose for which a building or other structure, or part thereof, is used or intended to be used 3.70 partition non-structural wall that is employed to divide spaces NOTE A non-structural wall does not support parts of the building other than itself. When it is on the exterior, it is sometimes referred as a curtain wall. 3.71 pedestal upright compression member with a ratio of unsupported height to average least lateral dimension of less than 3 3.72 permanent load load for which the variations over time are rare or of small magnitude NOTE All other loads are variable loads (see also nominal loads). 3.73 pile slender timber, concrete or structural steel element embedded in the ground to support loads 3.74 plain reinforcement smooth-surfaced steel reinforcement or reinforcement that does not conform to the definition of deformed reinforcement oSIST ISO 15673:2011



ISO 15673:2005(E) © ISO 2005 – All rights reserved 93.75 positive moment flexural moment that produces tension stresses at the lower part of the section of a horizontal or nearly horizontal element and that requires placing positive flexural reinforcement in the lower part of the element section 3.76 positive reinforcement flexural reinforcement in horizontal or nearly horizontal elements required for positive moment and that is placed in the lower part of the section of the element 3.77 reaction resistance to a force or load, or upward resistance of a support such as a structural concrete wall or column against the downward pressure of a loaded member such as a beam 3.78 reinforcement steel bars, wire, or mesh wire, used for reinforcing the concrete where tensile stresses are expected, due either to the applied loads or to environmental effects such as variation of temperature 3.79 required factored strength strength of a member or cross-section required to resist factored loads or related internal moments and forces in such combinations as are stipulated by this International Standard 3.80 retaining wall wall built to hold back earth 3.81 selfweight weight of the structural element, due to the material that composes the element 3.82 service load load specified by this International Standard (without load factors) 3.83 settlement downward movement of the supporting soil 3.84 shear internal force acting tangential to the plane where it acts NOTE Also called diagonal tension. 3.85 shear reinforcement reinforcement designed to resist shear 3.86 shores vertical or inclined support members designed to carry the weight of the formwork, concrete and construction loads above oSIST ISO 15673:2011



ISO 15673:2005(E) 10 © ISO 2005 – All rights reserved 3.87 shrinkage and temperature reinforcement reinforcement normal to flexural reinforcement provided for shrinkage and temperature stresses in structural solid slabs and footings where flexural reinforcement extends in only
...

Questions, Comments and Discussion