Semiconductor devices - Semiconductor interface for human body communication - Part 1: General requirements (IEC 62779-1:2016)

This part of IEC 62779 defines general requirements for a semiconductor interface used in
human body communication (HBC). It includes general and functional specifications of the
interface, as well as limiting values and its operating conditions.
NOTE Additional information on HBC is provided in Annex A.

Halbleiterbauelemente - Halbleiterschnittstelle zur Kommunikation über den menschlichen Körper - Teil 1: Allgemeine Anforderungen

Dispositifs à semi-conducteurs - Interface à semi-conducteurs pour les communications via le corps humain - Partie 1: Exigences générales (IEC 62779-1:2016)

L'IEC 62779-1:2016 définit des exigences générales d'une interface à semiconducteurs utilisée pour les communications via le corps humain (HBC). Elle inclut des spécifications générales et fonctionnelles de l'interface, ainsi que des valeurs limites et ses conditions de fonctionnement.

Polprevodniški elementi - Polprevodniški vmesnik za komuniciranje človeškega telesa - 1. del: Splošne zahteve (IEC 62779-1:2016)

Ta del standarda IEC 62779 določa splošne zahteve za polprevodniški vmesnik za komuniciranje človeškega telesa (HBC). Vključuje splošne in funkcionalne specifikacije vmesnika, pa tudi mejne vrednosti in pogoje za njegovo delovanje.
OPOMBA: Dodatne informacije o HBC so v dodatku A.

General Information

Status
Published
Publication Date
19-Jun-2016
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Jun-2016
Due Date
19-Aug-2016
Completion Date
20-Jun-2016

Buy Standard

Standard
EN 62779-1:2016 - BARVE
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62779-1:2016
01-september-2016
3ROSUHYRGQLãNLHOHPHQWL3ROSUHYRGQLãNLYPHVQLN]DNRPXQLFLUDQMHþORYHãNHJD
WHOHVDGHO6SORãQH]DKWHYH ,(&
Semiconductor devices - Semiconductor interface for human body communication - Part
1: General requirements (IEC 62779-1:2016)
Dispositifs à semi-conducteurs - Interface à semi-conducteurs pour les communications
via le corps humain - Partie 1: Exigences générales (IEC 62779-1:2016)
Ta slovenski standard je istoveten z: EN 62779-1:2016
ICS:
31.080.01 Polprevodniški elementi Semiconductor devices in
(naprave) na splošno general
SIST EN 62779-1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62779-1:2016

---------------------- Page: 2 ----------------------

SIST EN 62779-1:2016


EUROPEAN STANDARD EN 62779-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
June 2016
ICS 31.080.01

English Version
Semiconductor devices - Semiconductor interface for human
body communication - Part 1: General requirements
(IEC 62779-1:2016)
Dispositifs à semiconducteurs - Interface à Halbleiterbauelemente - Halbleiterschnittstelle zur
semiconducteurs pour les communications via le corps Kommunikation über den menschlichen Körper -
humain - Partie 1: Exigences générales Teil 1: Allgemeine Anforderungen
(IEC 62779-1:2016) (IEC 62779-1:2016)
This European Standard was approved by CENELEC on 2016-03-24. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 62779-1:2016 E

---------------------- Page: 3 ----------------------

SIST EN 62779-1:2016
EN 62779-1:2016
European foreword
The text of document 47/2267/FDIS, future edition 1 of IEC 62779-1, prepared by IEC/TC 47
"Semiconductor devices" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN 62779-1:2016.
The following dates are fixed:
(dop) 2016-12-24
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2019-03-24
• latest date by which the national standards conflicting with
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62779-1:2016 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated :
IEC 62779 NOTE Harmonized in EN 62779 series.

2

---------------------- Page: 4 ----------------------

SIST EN 62779-1:2016




IEC 62779-1

®


Edition 1.0 2016-02




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Semiconductor devices – Semiconductor interface for human body

communication –

Part 1: General requirements




Dispositifs à semiconducteurs – Interface à semiconducteurs pour les

communications via le corps humain –


Partie 1: Exigences générales














INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 31.080.01 ISBN 978-2-8322-3176-0



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 5 ----------------------

SIST EN 62779-1:2016
– 2 – IEC 62779-1:2016 © IEC 2016
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references. 6
3 Terms, definitions and letter symbols . 6
3.1 General terms . 6
3.2 Rating and characteristics . 7
3.2.1 Input characteristics . 7
3.2.2 Transfer characteristics . 7
3.3 Letter symbols . 9
4 General requirements for HBC semiconductor interface . 9
4.1 General specifications . 9
4.1.1 General . 9
4.1.2 Function . 9
4.1.3 Implementation types . 10
4.2 Constructional specifications . 10
4.3 Electrical specifications . 11
4.3.1 General . 11
4.3.2 Power supply characteristics . 11
4.3.3 Power supply type . 11
4.3.4 Dynamic characteristics of analog front end . 11
4.3.5 CDR circuit interface . 11
4.3.6 Modem interface . 12
4.3.7 Limiting values . 12
4.3.8 Temperatures . 12
4.4 Operating specifications . 12
4.4.1 Application . 12
4.4.2 Grounding condition . 13
4.4.3 Contact condition . 13
Annex A (informative) General description of HBC . 14
Annex B (informative) Generation of powerline noise signal in HBC . 15
Annex C (informative) Calculation of sensitivity level . 16
Bibliography . 17

Figure 1 – Definition of cut-off frequency and bandwidth . 8
Figure 2 – Block diagram (example) . 10
Figure A.1 – HBC applications . 14
Figure B.1 – Coupling of electromagnetic fields and the human body . 15

Table 1 – Letter symbols . 9

---------------------- Page: 6 ----------------------

SIST EN 62779-1:2016
IEC 62779-1:2016 © IEC 2016 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

SEMICONDUCTOR DEVICES –
SEMICONDUCTOR INTERFACE FOR HUMAN BODY COMMUNICATION –

Part 1: General requirements

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62779-1 has been prepared by IEC technical
committee 47:Semiconductor devices.
The text of this standard is based on the following documents:
FDIS Report on voting
47/2267/FDIS 47/2277/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 7 ----------------------

SIST EN 62779-1:2016
– 4 – IEC 62779-1:2016 © IEC 2016
A list of all parts in the IEC 62779 series, published under the general title Semiconductor
devices – Semiconductor interface for human body communication, can be found on the IEC
website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 8 ----------------------

SIST EN 62779-1:2016
IEC 62779-1:2016 © IEC 2016 – 5 –
INTRODUCTION
The IEC 62779 series is composed of three parts as follow:
• IEC 62779-1 defines general requirements of a semiconductor interface for human body
communication. It includes general and functional specifications of the interface.
• IEC 62779-2 defines a measurement method on electrical performances of an electrode
that constructs a semiconductor interface for human body communication.
1
• IEC 62779-3 defines functional type of a semiconductor interface for human body
communication, and operational conditions of the interface.
IEC 60748-4 gives requirements on interface integrated circuits for semiconductor devices.
Especially, Chapter III, Section 7 in this standard is applied to interface circuits for a
communication network using a general channel, such as wire or wireless. However, a
channel for HBC is the human body whose channel properties, such as signal loss and delay
profile, are different from the general channel, so Chapter III, Section 7 can’t be applied to an
interface for HBC. Furthermore, a standard on a communication protocol for body area
network (BAN) − IEEE 802.15.6, which includes a communication protocol for HBC was
published in 2012. A common interface for HBC should be defined to secure communication
compatibility between various devices that are implemented on/inside the human body or
embedded in peripheral equipments.

___________
1
 To be published.

---------------------- Page: 9 ----------------------

SIST EN 62779-1:2016
– 6 – IEC 62779-1:2016 © IEC 2016
SEMICONDUCTOR DEVICES –
SEMICONDUCTOR INTERFACE FOR HUMAN BODY COMMUNICATION –

Part 1: General requirements



1 Scope
This part of IEC 62779 defines general requirements for a semiconductor interface used in
human body communication (HBC). It includes general and functional specifications of the
interface, as well as limiting values and its operating conditions.
NOTE Additional information on HBC is provided in Annex A.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
None.
3 Terms, definitions and letter symbols
For the purposes of this document, the following terms and definitions apply.
3.1 General terms
3.1.1
HBC semiconductor interface
semiconductor interface to process an electrical signal that is transmitted to the human body
or received from the human body while located between the human body and HBC modem;
implemented on/inside the human body and embedded in peripheral equipment
Note 1 to entry: HBC semiconductor interface consists of an electrode and analog front end. The HBC modem
converts data into an electrical signal and sends it to the electrode, or receives an electrical signal from the analog
f
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.