Mobile non-sewer-connected toilet cabins - Requirements of services and products relating to the deployment of cabins and sanitary products

This standard covers the requirements for services for mobile, non sewer-connected toilet cabins considering also hygiene, health and safety. Minimum qualitative requirements for cabins and sanitary products are also dealt with.

Mobile anschlussfreie Toilettenkabinen - Anforderungen an Dienstleistungen und Produkte für den Einsatz von Kabinen und Sanitärprodukten

Diese Norm gilt für mobile, anschlussfreie Toilettenkabinen.
Sie legt Anforderungen fest an die Dienstleistung bezüglich des Einsatzes der Kabinen und die benötigten Anforderungen an Kabinen und Sanitärprodukte unter Berücksichtigung von Hygiene, Gesundheit und Sicherheit.
Sie legt Mindest-Qualitätsvorgaben fest für die Kabinen und Sanitärprodukte sowie für den Reinigungsumfang, Anzahl der zu stellenden Kabinen, Standorte und Reinigungs-/Entsorgungsintervalle.

Cabines sanitaires mobiles autonomes - Exigences relatives aux services et produits, liées à la mise en place des cabines et des produits sanitaires

La présente norme s’applique aux cabines sanitaires mobiles qui ne sont pas raccordées à un collecteur d’assainissement.
Elle spécifie les exigences de service liées à la mise en place de cabines et les exigences correspondantes relatives aux cabines et produits sanitaires, en tenant compte de l’hygiène, de la santé et de la sécurité.
Elle spécifie des exigences de qualité minimales relatives aux cabines et aux produits sanitaires, l’étendue de nettoyage exigée, le nombre de cabines devant être fournies, les emplacements et les intervalles d’entretiens (pompage des effluents et leur évacuation).

Premične toaletne kabine brez odvajanja v kanalizacijo - Zahteve za servis in proizvode glede na uporabo kabin in sanitarnih proizvodov

Ta standard zajema zahteve za servis za premične toaletne kabine brez odvajanja v kanalizacijo, pri čemer upošteva tudi higieno, zdravje in varnost. Obravnava tudi minimalne kakovostne zahteve za kabine in sanitarne proizvode.

General Information

Status
Withdrawn
Public Enquiry End Date
24-Dec-2010
Publication Date
10-Apr-2012
Withdrawal Date
27-Jun-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
27-Jun-2023
Due Date
20-Jul-2023
Completion Date
28-Jun-2023

Relations

Buy Standard

Standard
EN 16194:2012
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 16194:2010
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Mobile anschlussfreie Toilettenkabinen - Anforderungen an Dienstleistungen und Produkte für den Einsatz von Kabinen und SanitärproduktenCabines sanitaires mobiles autonomes - Exigences relatives aux services et produits, liées à la mise en place des cabines et des produits sanitairesMobile non-sewer-connected toilet cabins - Requirements of services and products relating to the deployment of cabins and sanitary products91.140.70Sanitarne napraveSanitary installationsICS:Ta slovenski standard je istoveten z:EN 16194:2012SIST EN 16194:2012en,fr,de01-maj-2012SIST EN 16194:2012SLOVENSKI
STANDARD



SIST EN 16194:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16194
February 2012 ICS 03.080.30; 91.040.99 English Version
Mobile non-sewer-connected toilet cabins - Requirements of services and products relating to the deployment of cabins and sanitary products
Cabines sanitaires mobiles autonomes - Exigences relatives aux services et produits, liées à la mise en place des cabines et des produits sanitaires
Mobile anschlussfreie Toilettenkabinen - Anforderungen an Dienstleistungen und Produkte für den Einsatz von Kabinen und Sanitärprodukten This European Standard was approved by CEN on 14 January 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16194:2012: ESIST EN 16194:2012



EN 16194:2012 (E) 2 Contents Page Foreword .3 Introduction .3 1 Scope .3 2 Terms and definitions .4 3 Types of deployment of mobile non-sewer-connected toilet cabins .4 4 Frequency of use, number of cabins, servicing intervals and accessibility .5 4.1 General provisions, except for events (deployment type A) .5 4.2 Deployment on construction sites (type D), agriculture (type E) and industry (type F) .5 4.3 Deployment on events (type A) .6 5 Product requirements .7 5.1 Mobile non-sewer-connected toilet cabins .7 5.1.1 General .7 5.1.2 Toilet cabin .7 5.1.3 Wheelchair-accessible toilet cabin .8 5.2 Sanitary products .9 5.2.1 Sanitary concentrates .9 5.2.2 Scented oils .9 5.2.3 Toilet paper .9 6 Service requirements .9 6.1 Precondition .9 6.2 Planning and advice .9 6.2.1 Long-term rental .9 6.2.2 Short-term rental .9 6.3 Delivery of the cabin . 10 6.4 On-site servicing . 10 6.5 Disposal of waste. 11 6.6 Collection of the cabin . 11 7 Documentation and records . 11 8 Designation of service . 11 Annex A (informative)
Legal requirements . 12
SIST EN 16194:2012



EN 16194:2012 (E) 3 Foreword This document (EN 16194:2012) has been prepared by Technical Committee CEN/TC 183 “Waste Management”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2012, and conflicting national standards shall be withdrawn at the latest by August 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Introduction There has been a necessity to use mobile sanitary facilities in many locations for more than 50 years. Since the early days, where they were mainly used on various construction sites, they have, over the years, been a convenient facility at both large and small events (such as the Olympic Games, the Football World Cup, World Youth Day, marathons, open-air-concerts, street festivals, weddings, during military missions, Papal visits, harvests, after natural disasters, in refugee camps, motorway rest areas, in open-cast mining, etc.). Whenever large numbers of people congregate over a longer period in places where there are no or only insufficient stationary sanitary facilities, it has become established practice to deploy mobile non-sewer-connected toilet cabins.
Adequate provision of cabins allows hygiene
and privacy.
This European Standard is directed at manufacturers, rental companies and renters of the cabins. 1 Scope This European Standard applies to mobile toilet cabins (excluding dry toilets) that are not connected to a sewerage system. It specifies requirements of the services relating to the deployment of cabins and the relevant requirements for cabins and sanitary products, taking into account hygiene, health and safety. It specifies minimum quality requirements relating to cabins and sanitary products and also relating to the extent of cleaning required, the number of cabins to be provided, locations and cleaning/disposal intervals. SIST EN 16194:2012



EN 16194:2012 (E) 4 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 mobile non-sewer-connected toilet cabin portable, self-contained unit intended to be used by a single person, with a waste tank that is not connected to a sewerage system 2.2 sanitary product concentrate with sanitary effect (liquid or solid); antifreeze for the waste tank; scented oils; toilet paper 2.3 service planning and advice, delivery of the cabin, on-site servicing, waste disposal and collection of the cabin 2.4 on-site servicing specified process of cleaning, replenishment and maintenance 2.5 rental company company which provides planning and advice, delivery of the cabin, on-site servicing, waste disposal and collection of the cabin 2.6 renter/owner companies, organizations or persons, that make use of the planning and advice service, the delivery of the cabin, on-site servicing, waste disposal and collection of the cabin 3 Types of deployment of mobile non-sewer-connected toilet cabins Mobile non-sewer-connected toilet cabins
...

SLOVENSKI STANDARD
oSIST prEN 16194:2010
01-december-2010
3UHPLþQHWRDOHWQHNDELQHEUH]RGYDMDQMDYNDQDOL]DFLMR=DKWHYH]DVHUYLVLQ
SURL]YRGHJOHGHQDXSRUDERNDELQLQVDQLWDUQLKSURL]YRGRY
Mobile non-sewer-connected toilet cabins - Requirements of services and products
relating to the deployment of cabins and sanitary products
Mobile anschlussfreie Toilettenkabinen - Anforderungen an Dienstleistungen und
Produkte für den Einsatz von Kabinen und Sanitärprodukten
Cabines sanitaires mobiles autonomes - Exigences relatives aux services et produits,
liées à la mise en place des cabines et des produits sanitaires
Ta slovenski standard je istoveten z: prEN 16194
ICS:
91.140.70 Sanitarne naprave Sanitary installations
oSIST prEN 16194:2010 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 16194:2010

---------------------- Page: 2 ----------------------
oSIST prEN 16194:2010


EUROPEAN STANDARD
DRAFT
prEN 16194
NORME EUROPÉENNE

EUROPÄISCHE NORM

October 2010
ICS 03.080.30; 91.040.99
English Version
Mobile non-sewer-connected toilet cabins - Requirements of
services and products relating to the deployment of cabins and
sanitary products
Cabines sanitaires mobiles autonomes - Exigences Mobile anschlussfreie Toilettenkabinen - Anforderungen an
relatives aux services et produits, liées à la mise en place Dienstleistungen und Produkte für den Einsatz von Kabinen
des cabines et des produits sanitaires und Sanitärprodukten
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 183.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16194:2010: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 16194:2010
prEN 16194:2010 (E)
Contents Page
Foreword .3
Introduction .3
1 Scope .3
2 Terms and definitions .3
3 Types of deployment of mobile non-sewer-connected toilet cabins .4
4 Frequency of use, number of cabins, servicing intervals and accessibility .4
4.1 General provisions, except for events (deployment type A) .4
4.2 Construction sites (deployment type D), industry (deployment type F) and agriculture
(deployment type E).5
4.3 Events (deployment type A) .5
5 Product requirements .6
5.1 Mobile non-sewer-connected toilet cabins .6
5.1.1 General .6
5.1.2 Toilet cabin .7
5.1.3 Wheelchair-accessible toilet cabin .8
5.2 Sanitary products .8
5.2.1 Sanitary concentrates .8
5.2.2 Scented oils .9
5.2.3 Toilet paper .9
6 Service requirements .9
6.1 Precondition .9
6.2 Planning and advice .9
6.2.1 Long-term rental .9
6.2.2 Short-term rental .9
6.3 Delivery of the cabin . 10
6.4 On-site servicing . 10
6.5 Disposal of waste. 11
6.6 Collection of the cabin . 11
7 Documentation and records . 11
8 Designation of service . 11
Annex A (informative) Legal requirements . 12

2

---------------------- Page: 4 ----------------------
oSIST prEN 16194:2010
prEN 16194:2010 (E)
Foreword
This document (prEN 16194:2010) has been prepared by Technical Committee CEN/TC 183 “Waste
Management”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
Annex A is informative.
Introduction
There has been a necessity to use mobile sanitary facilities in many locations for more than 50 years. From
the early days (where they were mainly used on a wide variety of construction sites) they have, over the
years, been a convenient facility at large and small events (such as the Olympic Games, the Football World
Cup, World Youth Day, marathons, open-air-concerts, street festivals, weddings, during military missions,
Papal visits, harvests, after natural disasters, in refugee camps, motorway rest areas, in open-cast mining,
etc.).
Whenever large numbers of people congregate over a longer period in places where there are no or only
insufficient stationary sanitary facilities, it has become established practice to deploy mobile non-sewer-
connected toilet cabins.
Adequate provision of cabins allows people to answer “the call of nature” hygienically and in privacy.
This standard is directed at manufacturers, rental companies and renters of the cabins.
1 Scope
This standard applies to mobile toilet cabins that are not connected to a sewerage system.
It specifies requirements of the services relating to the deployment of cabins and the relevant requirements for
cabins and sanitary products, taking into account hygiene, health and safety.
It specifies minimum quality requirements relating to cabins and sanitary products and also relating to the
extent of cleaning required, the number of cabins to be provided, locations and cleaning/disposal intervals.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
mobile non-sewer-connected toilet cabin
portable, self-contained unit with a waste tank that is not connected to a sewerage system and is intended to
be used by a single person
3

---------------------- Page: 5 ----------------------
oSIST prEN 16194:2010
prEN 16194:2010 (E)
2.2
sanitary product
concentrate with sanitary effect (liquid or solid); antifreeze for the waste tank; scented oils; toilet paper
2.3
service
planning and advice, delivery of the cabin, on-site servicing, waste disposal and collection of the cabin
2.4
on-site servicing
specified process of cleaning, replenishment and maintenance
2.5
rental company
company which provides planning and advice, delivery of the cabin, on-site servicing, waste disposal and
collection of the cabin
2.6
renter
companies, organizations or persons, that make use of the planning and advice service, the delivery of the
cabin, on-site servicing, waste disposal and collection of the cabin
3 Types of deployment of mobile non-sewer-connected toilet cabins
Mobile non-sewer-connected toilet cabins are deployed as follows:
 for events (deployment type A);
 for military missions (deployment type B);
 for disaster-relief work (deployment type C);
 on construction sites (deployment type D);
 in agricultur
...

Questions, Comments and Discussion