Leather - Determination of ethoxylated alkylphenols - Part 1: Direct method (ISO 18218-1:2015)

This standard specifies a method for the determination of ethoxylated alkylphenols  by a direct method

Leder - Chemische Bestimmung von ethoxylierten Alkylphenolen - Teil 1: Direktes Verfahren (ISO 18218-1:2015)

Diese Norm legt ein Verfahren zur Bestimmung von Alkylphenolethoxylat (Nonylphenolethoxylat und Octylphenolethoxylat) in Leder fest. Dieses direkte Verfahren ist geeignet, wenn eine größere Anzahl von Lederproben auf die Anwesenheit von Alkylphenolethoxylaten zu überprüfen sind.
Dieses Verfahren erfordert die Verwendung von HPLC mit einem Triple-Quadrupol-Massenspektrometer, um das Alkylphenolethoxylat zu identifizieren.
Anhang A dieser Norm ist informativ.

Cuir - Détermination chimique des alkylphénols éthoxylés - Partie 1: Méthode directe (ISO 18218-1:2015)

ISO 18218-1:2015 spécifie une méthode de détermination des alkylphénols éthoxylés (éthoxylate de nonylphénol [NPEOn, où 1 ≤ n ≤ 16] et éthoxylate d'octylphénol [OPEOn, où 1 ≤ n ≤ 16]) dans le cuir. Cette méthode d'analyse directe convient particulièrement lorsque les alkylphénols éthoxylés doivent être dosés sur un grand nombre d'échantillons de cuir.
L'analyse est effectuée par chromatographie en phase liquide à haute performance (CLHP) couplée à la spectrométrie de masse en tandem avec un analyseur à triple quadripôle, afin d'identifier et de quantifier les alkylphénols éthoxylés.
NOTE 1       Parmi les alkylphénols éthoxylés disponibles dans le commerce, celui qui est le plus utilisé dans l'industrie du cuir est l'éthoxylate de nonylphénol contenant en moyenne 9 groupes éthoxy. La température de trouble dans l'eau de cette substance est optimale compte tenu des températures généralement utilisées pour le traitement du cuir, qui sont comprises entre 40 °C et 55 °C.
NOTE 2       L'ISO 18218‑1 et l'ISO 18218‑2 impliquent l'utilisation de solvants différents pour l'extraction des alkylphénols éthoxylés du cuir. Par conséquent, on peut s'attendre à ce que les résultats obtenus en suivant l'une des deux méthodes analytiques soient comparables à ceux obtenus en suivant la seconde méthode, mais non nécessairement identiques, pour ce qui concerne la teneur en alkylphénols éthoxylés dans le cuir.

Usnje - Določevanje etoksilatnih alkilfenolov - 1. del: Neposredna metoda (ISO 18218-1:2015)

Ta standard določa metodo za določevanje etoksilatnih alkilfenolov z neposredno metodo.

General Information

Status
Withdrawn
Public Enquiry End Date
01-Mar-2015
Publication Date
26-Jul-2015
Withdrawal Date
03-Jul-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
03-Jul-2023
Due Date
26-Jul-2023
Completion Date
04-Jul-2023

Relations

Buy Standard

Standard
EN ISO 18218-1:2015
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN ISO 18218-1:2015
German language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 18218-1:2015
01-september-2015
8VQMH'RORþHYDQMHHWRNVLODWQLKDONLOIHQRORYGHO1HSRVUHGQDPHWRGD ,62

Leather - Determination of ethoxylated alkylphenols - Part 1: Direct method (ISO 18218-
1:2015)
Leder - Chemische Bestimmung von ethoxylierten Alkylphenolen - Teil 1: Direktes
Verfahren (ISO 18218-1:2015)
Cuir - Détermination chimique des alkylphénols éthoxylés - Partie 1: Méthode directe
(ISO 18218-1:2015)
Ta slovenski standard je istoveten z: EN ISO 18218-1:2015
ICS:
59.140.30 Usnje in krzno Leather and furs
SIST EN ISO 18218-1:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 18218-1:2015

---------------------- Page: 2 ----------------------

SIST EN ISO 18218-1:2015

EUROPEAN STANDARD
EN ISO 18218-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
June 2015
ICS 59.140.30
English Version
Leather - Determination of ethoxylated alkylphenols - Part 1:
Direct method (ISO 18218-1:2015)
Cuir - Détermination chimique des alkylphénols éthoxylés - Leder - Bestimmung von ethoxylierten Alkylphenolen - Teil
Partie 1: Méthode directe (ISO 18218-1:2015) 1: Direktes Verfahren (ISO 18218-1:2015)
This European Standard was approved by CEN on 28 February 2015.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 18218-1:2015 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 18218-1:2015
EN ISO 18218-1:2015 (E)
Contents Page
European foreword .3

2

---------------------- Page: 4 ----------------------

SIST EN ISO 18218-1:2015
EN ISO 18218-1:2015 (E)
European foreword
This document (EN ISO 18218-1:2015) has been prepared by Technical Committee CEN/TC 289 “Leather”,
the secretariat of which is held by UNI, in collaboration with Technical Committee IULTCS “International Union
of Leather Technologists and Chemists Societies”.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by December 2015, and conflicting national standards shall be withdrawn
at the latest by December 2015.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 18218-1:2015 has been approved by CEN as EN ISO 18218-1:2015 without any modification.
3

---------------------- Page: 5 ----------------------

SIST EN ISO 18218-1:2015

---------------------- Page: 6 ----------------------

SIST EN ISO 18218-1:2015
INTERNATIONAL ISO
STANDARD 18218-1
IULTCS/IUC 28-1
First edition
2015-06-15
Leather — Determination of
ethoxylated alkylphenols —
Part 1:
Direct method
Cuir — Détermination des alkylphénols éthoxylés —
Partie 1: Méthode directe
Reference numbers
ISO 18218-1:2015(E)
IULTCS/IUC 28-1:2015(E)
©
ISO 2015

---------------------- Page: 7 ----------------------

SIST EN ISO 18218-1:2015
ISO 18218-1:2015(E)
IULTCS/IUC 28-1:2015(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2015, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – All rights reserved

---------------------- Page: 8 ----------------------

SIST EN ISO 18218-1:2015
ISO 18218-1:2015(E)
IULTCS/IUC 28-1:2015(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Principle . 1
4 Apparatus and materials. 1
5 Chemicals . 2
6 Sampling . 2
7 Sample preparation and analysis . 3
7.1 Extraction . 3
7.2 Analysis. 3
7.3 Calibration . 3
7.4 Calculation . 3
8 Test report . 3
Annex A (informative) Chromatographic analysis operating parameters . 5
Bibliography . 7
© ISO 2015 – All rights reserved iii

---------------------- Page: 9 ----------------------

SIST EN ISO 18218-1:2015
ISO 18218-1:2015(E)
IULTCS/IUC 28-1:2015(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical Barriers
to Trade (TBT) see the following URL: Foreword - Supplementary information
ISO 18218-1 was prepared by the Chemical Test Commission of the International Union of Leather
Technologists and Chemists Societies (IUC Commission, IULTCS) in collaboration with the European
Committee for Standardization (CEN) Technical Committee CEN/TC 289, Leather, the secretariat of
which is held by UNI, in accordance with the Agreement on technical cooperation between ISO and CEN
(Vienna Agreement).
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to
further the advancement of leather science and technology. IULTCS has three Commissions, which are
responsible for establishing international methods for the sampling and testing of leather. ISO recognizes
IULTCS as an international standardizing body for the preparation of test methods for leather.
ISO 18218 consists of the following parts, under the general title Leather — Determination of ethoxylated
alkylphenols:
— Part 1: Direct method
— Part 2: Indirect method
iv © ISO 2015 – All rights reserved

---------------------- Page: 10 ----------------------

SIST EN ISO 18218-1:2015
ISO 18218-1:2015(E)
IULTCS/IUC 28-1:2015(E)
Introduction
Nonylphenol ethoxylate belongs to the non-ionic surfactants. The biodegradation of nonylphenol
ethoxylate releases the persistent pollutant, the branched nonylphenol. Nonylphenol is a hormonal
acting substance that is toxic for waterborne organisms and many other organisms. For this reason the
release of nonylphenol ethoxylate into the environme
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Leder - Chemische Bestimmung von ethoxylierten Alkylphenolen - Teil 1: Direktes Verfahren (ISO/FDIS 18218-1:2014)Cuir - Détermination chimique des alkylphénols éthoxylés - Partie 1: Méthode directe (ISO/FDIS 18218-1:2014)Leather - Determination of ethoxylated alkylphenols - Part 1: Direct method (ISO/FDIS 18218-1:2014)59.140.30Usnje in krznoLeather and fursICS:Ta slovenski standard je istoveten z:FprEN ISO 18218-1kSIST FprEN ISO 18218-1:2015de01-februar-2015kSIST FprEN ISO 18218-1:2015SLOVENSKI
STANDARD



kSIST FprEN ISO 18218-1:2015



EUROPÄISCHE NORM EUROPEAN STANDARD NORME EUROPÉENNE
SCHLUSS-ENTWURF
FprEN ISO 18218-1
November 2014 ICS 59.140.30 Deutsche Fassung
Leder - Bestimmung von ethoxylierten Alkylphenolen - Teil 1: Direktes Verfahren (ISO/FDIS 18218-1:2014)
Leather - Determination of ethoxylated alkylphenols - Part 1: Direct method (ISO/FDIS 18218-1:2014)
Cuir - Détermination chimique des alkylphénols éthoxylés - Partie 1: Méthode directe (ISO/FDIS 18218-1:2014) Dieser Europäische Norm-Entwurf wird den CEN-Mitgliedern zur parallelen formellen Abstimmung vorgelegt. Er wurde vom Technischen Komitee CEN/TC 289 erstellt.
Wenn aus diesem Norm-Entwurf eine Europäische Norm wird, sind die CEN-Mitglieder gehalten, die CEN-Geschäftsordnung zu erfüllen, in der die Bedingungen festgelegt sind, unter denen dieser Europäischen Norm ohne jede Änderung der Status einer nationalen Norm zu geben ist.
Dieser Europäische Norm-Entwurf wurde vom CEN in drei offiziellen Fassungen (Deutsch, Englisch, Französisch) erstellt. Eine Fassung in einer anderen Sprache, die von einem CEN-Mitglied in eigener Verantwortung durch Übersetzung in seine Landessprache gemacht und dem Management-Zentrum des CEN-CENELEC mitgeteilt worden ist, hat den gleichen Status wie die offiziellen Fassungen.
CEN-Mitglieder sind die nationalen Normungsinstitute von Belgien, Bulgarien, Dänemark, Deutschland, der ehemaligen jugoslawischen Republik Mazedonien, Estland, Finnland, Frankreich, Griechenland, Irland, Island, Italien, Kroatien, Lettland, Litauen, Luxemburg, Malta, den Niederlanden, Norwegen, Österreich, Polen, Portugal, Rumänien, Schweden, der Schweiz, der Slowakei, Slowenien, Spanien, der Tschechischen Republik, der Türkei, Ungarn, dem Vereinigten Königreich und Zypern.
Die Empfänger dieses Norm-Entwurfs werden gebeten, mit ihren Kommentaren jegliche relevante Patentrechte, die sie kennen, mitzuteilen und unterstützende Dokumentationen zur Verfügung zu stellen.
Warnvermerk : Dieses Schriftstück hat noch nicht den Status einer Europäischen Norm. Es wird zur Prüfung und Stellungnahme vorgelegt. Es kann sich noch ohne Ankündigung ändern und darf nicht als Europäischen Norm in Bezug genommen werden.
EUROPÄISCHES KOMITEE FÜR NORMUNG EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
CEN-CENELEC Management-Zentrum:
Avenue Marnix 17,
B-1000 Brüssel © 2014 CEN Alle Rechte der Verwertung, gleich in welcher Form und in welchem Verfahren, sind weltweit den nationalen Mitgliedern von CEN vorbehalten.Ref. Nr. FprEN ISO 18218-1:2014 DkSIST FprEN ISO 18218-1:2015



FprEN ISO 18218-1:2014 (D) 2 Inhalt
Seite Vorwort .3 Einleitung .4 1 Anwendungsbereich .5 2 Normative Verweisungen .5 3 Kurzbeschreibung .5 4 Prüfgeräte und Materialien .5 5 Chemikalien .6 6 Probenahme .7 7 Probenvorbereitung und Analyse .7 7.1 Extraktion .7 7.2 Analyse .7 7.3 Kalibrierung .7 7.4 Berechnung .7 8 Prüfbericht .8 Anhang A (informativ)
Betriebsparameter der chromatografischen Analyse.9 A.1 Vorbemerkung .9 A.2 Betriebsparameter für Hochleistungsflüssigkeitschromatographie (HPLC) und Triple-Quadrupol-Massenspektrometer (MSMS) .9 A.3 Beispiel von Chromatogramm und Massenspektrum von Nonylphenolethoxylat, NPEOn . 10 Literaturhinweise . 12
kSIST FprEN ISO 18218-1:2015



FprEN ISO 18218-1:2014 (D) 3 Vorwort Dieses Dokument (FprEN ISO 18218-1:2014) wurde vom Technischen Komitee CEN/TC 289 „Leder“ dessen Sekretariat vom UNI gehalten wird, in Zusammenarbeit mit dem Technischen Komitee ISO/TC IULTCS „International Union of Leather Technologists and Chemists Societies“ erarbeitet. Dieses Dokument ist derzeit zur parallelen formellen Abstimmung vorgelegt. ISO 18218, Leather — Determination of ethoxylated alkylphenols, besteht aus den folgenden Teilen:  Part 1: Direct Method  Part 2: Indirect Method Anerkennungsnotiz Der Text von ISO/FDIS 18218-1:2014 wurde vom CEN als FprEN ISO 18218-1:2014 ohne irgendeine Abänderung genehmigt. kSIST FprEN ISO 18218-1:2015



FprEN ISO 18218-1:2014 (D) 4 Einleitung Nonylphenolethoxylat gehört zu den nicht-ionischen Tensiden. Beim biologischen Abbau von Nonylphenolethoxylat wird der langlebige Schadstoff, das verzweigte Nonylphenol freigesetzt. Nonylphenol ist eine hormonell wirkende Substanz, die für Wasserorganismen und viele andere Organismen toxisch ist. Die Freisetzung von Nonylphenolethoxylat in die Umwelt sollte aus diesem Grund vermieden werden. Im Jahr 2003 hat die Europäische Richtlinie 2003/53/EG den Verkauf und die Verwendung von Nonylphenol und Nonylphenolethoxylat in Produktzubereitungen für Branchen mit Einleitungen ins Abwasser beschränkt. Zubereitungen, die Konzentrationen gleich oder höher als 0,1 % Nonylphenolethoxylat oder Nonylphenol enthalten, wurden verboten. Diese Richtlinie ist Teil der EU-Verordnung 1907/2006 (REACH). Eine detaillierte Zusammensetzung des chemischen Stoffes Nonylphenolethoxylat kann nicht angegeben werden, dem Stoff wird die allgemeine Strukturformel zugewiesen: (C9-Alkylkette, verzweigt oder linear) – Ph – [OCH2CH2]n−OH
(mit Ph = Phenyl, n ≥ 1). Die Europäische Chemikalienagentur (ECHA) hat, um die Gruppe der verzweigten oder linearen Ethoxylate von 4-Nonylphenol zu erfassen, dem Stoff die folgende Definition zugewiesen: 4-Nonylphenol, verzweigt oder linear, ethoxyliert [Stoffe mit einer linearen und/oder verzweigten Alkylkette mit einer Kohlenstoffzahl von 9, in Position 4 an Phenol kovalent gebunden, ethoxyliert, umfassen UVCB- und chemisch genau definierte Stoffe, Polymere und Homologe, die jedes der einzelnen Isomere und/oder Kombinationen aus ihnen einschließen]. In der Lederindustrie wurden Nonylphenolethoxylat und Octylphenolethoxylat als Tenside verwendet. Jedoch wurden die in Wasser unlöslichen Stoffe Nonylphenol und Octylphenol nicht verwendet. Aus diesem Grund wurden zwei unterschiedliche analytische Verfahren zur Analyse von Lederproben entwickelt. Dieser Teil der ISO 18218 ist ein Verfahren zur direkten Bestimmung des ethoxylierten Alkylphenols. Es ist ein effizientes Verfahren für die Analyse einer größeren Anzahl von Lederproben. Dieses Verfahren erfordert eine HPLC mit einem Triple-Quadrupol-Massenspektrometer (MSMS), um Nonylphenolethoxylat und Octylphenolethoxylat zu identifizieren. Die ISO 18218-2 ist ein Verfahren zur Analyse des Alkylphenols. Das ethoxylierte Alkylphenol wird unter Freisetzung des Alkylphenols gespalten, das mithilfe von Hochleistungsflüssigkeitschromatographie (HPLC) oder Gaschromatographie mit Massenspektrometrie-Kopplung (GC-MS) identifiziert wird. Dieses Verfahren kann auch angewendet werden, um den Gehalt an Alkylphenolethoxylat in Leder und Prozesshilfsstoffen indirekt zu bestimmen. kSIST FprEN ISO 18218-1:2015



FprEN ISO 18218-1:2014 (D) 5 1 Anwendungsbereich Dieser Teil der ISO 18218 legt ein Verfahren zur Bestimmung von ethoxylierten Alkylphenolen [Nonylphenolethoxylat (NPEOn mit 1 ≤ n ≤ 16) und Octylphenolethoxylat (OPEOn mit 1 ≤ n ≤ 16)] in Leder fest. Dieses direkte Verfahren ist besonders geeignet, wenn eine größere Anzahl von Lederproben auf
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.