Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 to 1 000 MHz, IEC 61169-8 connectors (IEC 60966-2-3:2009)

This part of IEC 60966 is a detail specification that applies to flexible coaxial cables described in IEC 60096-2. It relates to flexible coaxial cable assemblies using BNC connectors. This detail specification gives subfamily requirements and severities which shall be applied . Under qualification approval, the qualification will be conducted in accordance with 12.2 of IEC 60966-2-1 taking into account the specified variants. Only the tests whose results might depend on the variants will be repeated. Under capability approval, the qualification will be conducted on the relating CQCs as defined in 12.3 of IEC 60966-2-1 and described in the CM. Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, all other tests will be performed on CQCs as defined in 12.3 of IEC 60966-2-1 and described in the CM.

Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 2-3: Bauartspezifikation für flexible konfektionierte Koaxialkabel - Frequenzbereich 0 bis 1000 MHz, Stecker nach IEC 61169-8 (IEC 60966-2-3:2009)

Ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques - Partie 2-3: Spécification particulière pour cordons coaxiaux souples - Bande de fréquences de 0 MHz à 1 000 MHz, connecteurs CEI 61169-8 (CEI 60966-2-3:2009)

La CEI 60966-2-3:2009 est une spécification particulière qui s'applique aux câbles coaxiaux souples décrits dans la CEI 60096-2. Elle concerne les cordons coaxiaux souples munis de connecteurs BNC. La présente spécification particulière donne les exigences et les sévérités de sous-famille qui doivent être appliquées. Pour obtenir l'homologation, les opérations de qualification seront réalisées conformément au 12.2 de la CEI 60966-2-1 en tenant compte des variantes spécifiées. Seuls les essais dont les résultats pourraient dépendre des variantes seront répétés. Pour obtenir l'agrément de savoir-faire, les opérations de qualification seront réalisées sur les CQC correspondants comme cela est défini en 12.3 de la CEI 60966-2-1 et décrit dans le manuel CM. Sauf spécification contraire dans le manuel CM, seuls les essais lot par lot des groupes Ba et Eb seront réalisés sur les produits livrés, tous les autres essais seront réalisés sur les CQC comme cela est défini en 12.3 de la CEI 60966-2-1 et décrit dans le manuel CM.
Cette publication doit être lue conjointement avec la CEI 60966-1:1999.
IEC 60966-2-1:2008 et IE 60966-2-2:2003
C

Radijska frekvenca in sestavi koaksialnih kablov - 2-1. del: Podrobna specifikacija za sestave fleksibilnih (zvijavih) koaksialnih kablov - Frekvenčno območje od 0 do 1 000 MHz, konektorji po IEC 61169-8 (IEC 60966-2-3:2009)

General Information

Status
Published
Publication Date
20-Sep-2009
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
12-Aug-2009
Due Date
17-Oct-2009
Completion Date
21-Sep-2009

Relations

Buy Standard

Standard
EN 60966-2-3:2009 - BARVE
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60966-2-3:2009
01-oktober-2009
1DGRPHãþD
SIST EN 60966-2-3:2004
5DGLMVNDIUHNYHQFDLQVHVWDYLNRDNVLDOQLKNDEORYGHO3RGUREQDVSHFLILNDFLMD
]DVHVWDYHIOHNVLELOQLK ]YLMDYLK NRDNVLDOQLKNDEORY)UHNYHQþQRREPRþMHRGGR
0+]NRQHNWRUMLSR,(& ,(&
Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible
coaxial cable assemblies - Frequency range 0 to 1 000 MHz, IEC 61169-8 connectors
(IEC 60966-2-3:2009)
Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 2-3: Bauartspezifikation für
flexible konfektionierte Koaxialkabel - Frequenzbereich 0 bis 1000 MHz, Stecker nach
IEC 61169-8 (IEC 60966-2-3:2009)
Ensembles de cordons coaxiaux et de cordons pour fréquences radioélectriques - Partie
2-3: Spécification particulière pour cordons coaxiaux souples - Bande de fréquences de
0 MHz à 1 000 MHz, connecteurs CEI 61169-8 (CEI 60966-2-3:2009)
Ta slovenski standard je istoveten z: EN 60966-2-3:2009
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
SIST EN 60966-2-3:2009 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60966-2-3:2009

---------------------- Page: 2 ----------------------

SIST EN 60966-2-3:2009


EUROPEAN STANDARD
EN 60966-2-3

NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM

ICS 33.120.10 Supersedes EN 60966-2-3:2003


English version


Radio frequency and coaxial cable assemblies -
Part 2-3: Detail specification for flexible coaxial cable assemblies -
Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors
(IEC 60966-2-3:2009)



Ensembles de cordons coaxiaux Konfektionierte Koaxial- und
et de cordons pour Hochfrequenzkabel -
fréquences radioélectriques - Teil 2-3: Bauartspezifikation
Partie 2-3: Spécification particulière für flexible konfektionierte Koaxialkabel -
pour cordons coaxiaux souples - Frequenzbereich 0 MHz bis 1000 MHz,
Bande de fréquences Steckverbinder nach IEC 61169-8
de 0 MHz à 1 000 MHz, (IEC 60966-2-3:2009)
connecteurs CEI 61169-8
(CEI 60966-2-3:2009)




This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels


© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60966-2-3:2009 E

---------------------- Page: 3 ----------------------

SIST EN 60966-2-3:2009
EN 60966-2-3:2009 - 2 -
Foreword
The text of document 46/302/FDIS, future edition 3 of IEC 60966-2-3, prepared by IEC TC 46, Cables,
wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was
submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-2-3 on
2009-07-01.
This European Standard supersedes EN 60966-2-3:2003.
The major change with respect to EN 60966-2-3:2003 is the reference to EN 61169-8 instead of
EN 60169-8.
This detail specification is to be read in conjunction with EN 60966-1:1999, with EN 60966-2-1:2009, and
with EN 60966-2-2:2003.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60966-2-3:2009 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 60966-2-3:2009
- 3 - EN 60966-2-3:2009
Annex ZA
(normative)

Reference documents with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60966-1 1999 Radio frequency and coaxial cable EN 60966-1 1999
assemblies -
Part 1: Generic specification - General
requirements and test methods


IEC 60966-2-1 2008 Radio frequency and coaxial cable EN 60966-2-1 2009
assemblies -
Part 2-1: Sectional specification for flexible
coaxial cable assemblies


IEC 60966-2-2 2003 Radio frequency and coaxial cable EN 60966-2-2 2003
assemblies -
Part 2-2: Blank detail specification for flexible
coaxial cable assemblies


1) 2)
IEC 61169-8 - Radio-frequency connectors - EN 61169-8 2007
Part 8: Sectional specification - RF coaxial
connectors with inner diameter of outer
conductor 6,5 mm (0,256 in) with bayonet
lock - Characteristics impedance 50 ohms
(type BNC)


1)
IEC 61196-6 - Coaxial communication cables - - -
Part 6: Sectional specification for CATV drop
cables




1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 5 ----------------------

SIST EN 60966-2-3:2009

---------------------- Page: 6 ----------------------

SIST EN 60966-2-3:2009
IEC 60966-2-3
Edition 3.0 2009-01
INTERNATIONAL
STANDARD


Radio frequency and coaxial cable assemblies –
Part 2-3: Detail specification for flexible coaxial cable assemblies – Frequency
range 0 MHz to 1 000 MHz, IEC 61169-8 connectors


INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
F
ICS 33.120.10 ISBN 2-8318-1022-1
® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 7 ----------------------

SIST EN 60966-2-3:2009
– 2 – 60966-2-3 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES –

Part 2-3: Detail specification for flexible coaxial cable assemblies –
Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.