Alarm systems - Intrusion and hold-up systems -- Part 2-7-2: Intrusion detectors - Glass break detectors (passive)

This Technical Specification is for passive surface mounted glass break detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors and uses environmental classes I to IV (see EN 50130-5). This Technical Specification does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.

Alarmanlagen - Einbruch- und Überfallmeldeanlagen -- Teil 2-7-2: Einbruchmelder - Glasbruchmelder (Passiv)

Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up -- Partie 2-7-2: Détecteurs d'intrusion - Détecteurs bris de glace (passifs)

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-2. del: Zahteve za javljalnike vloma - Javljalniki loma stekla (pasivni)

General Information

Status
Withdrawn
Publication Date
10-Sep-2009
Withdrawal Date
15-Jun-2015
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
16-Jun-2015
Due Date
09-Jul-2015
Completion Date
16-Jun-2015

Relations

Buy Standard

Technical specification
TS CLC/TS 50131-2-7-2:2009
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CLC/TS 50131-2-7-2:2009
01-oktober-2009
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-2. del: Zahteve za
javljalnike vloma - Javljalniki loma stekla (pasivni)
Alarm systems - Intrusion and hold-up systems -- Part 2-7-2: Intrusion detectors - Glass
break detectors (passive)
Alarmanlagen - Einbruch- und Überfallmeldeanlagen -- Teil 2-7-2: Einbruchmelder -
Glasbruchmelder (Passiv)
Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up -- Partie 2-7-2:
Détecteurs d'intrusion - Détecteurs bris de glace (passifs)
Ta slovenski standard je istoveten z: CLC/TS 50131-2-7-2:2009
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST-TS CLC/TS 50131-2-7-2:2009 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009

---------------------- Page: 2 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009

TECHNICAL SPECIFICATION
CLC/TS 50131-2-7-2

SPÉCIFICATION TECHNIQUE
March 2009
TECHNISCHE SPEZIFIKATION

ICS 13.320


English version


Alarm systems -
Intrusion and hold-up systems -
Part 2-7-2: Intrusion detectors -
Glass break detectors (passive)



Systèmes d’alarme -  Alarmanlagen -
Systèmes d'alarme contre l’intrusion Einbruch- und Überfallmeldeanlagen -
et les hold-up - Teil 2-7-2: Einbruchmelder -
Partie 2-7-2: Détecteurs d'intrusion - Glasbruchmelder (Passiv)
Détecteurs bris de glace (passifs)






This Technical Specification was approved by CENELEC on 2009-03-06.

CENELEC members are required to announce the existence of this TS in the same way as for an EN and to
make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting
national standards in force.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.



CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: avenue Marnix 17, B - 1000 Brussels


© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. CLC/TS 50131-2-7-2:2009 E

---------------------- Page: 3 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 2 –
Foreword
This Technical Specification was prepared by the Technical Committee CENELEC TC 79, Alarm systems.
The text of the draft was circulated for voting in accordance with the CEN/CENELEC Internal Regulations,
Part 2, Subclause 11.3.3.3 and was approved by CENELEC as CLC/TS 50131-2-7-2 on 2009-03-06.
The following date was fixed:
– latest date by which the existence of the CLC/TS
has to be announced at national level (doa) 2009-09-06
EN 50131 will consist of the following parts, under the general title “Alarm systems – Intrusion and hold-up
systems”:
Part 1 System requirements
Part 2-2 Intrusion detectors - Passive infrared detectors
Part 2-3 Requirements for microwave detectors
Part 2-4 Requirements for combined passive infrared and microwave detectors
Part 2-5 Requirements for combined passive infrared and ultrasonic detectors
Part 2-6 Opening contacts (magnetic)
Part 2-7-1 Intrusion detectors - Glass break detectors (acoustic)
Part 2-7-2 Intrusion detectors - Glass break detectors (passive)
Part 2-7-3 Intrusion detectors - Glass break detectors (active)
Part 3 Control and indicating equipment
Part 4 Warning devices
Part 5-3 Requirements for interconnections equipment using radio frequency techniques
Part 6 Power supplies
Part 7 Application guidelines
Part 8 Security fog device/system
This Technical Specification provides for security grades 1 to 4 (see EN 50131–1) glass break (passive)
detectors installed in buildings and uses environmental classes I to IV (see EN 50130–5).
The purpose of a detector is to detect the energy exclusively emitted by the physical destruction of
a glass pane, which allows intrusion to the monitored area, for example in doors, windows or enclosures,
and to provide the necessary range of signals or messages to be used by the rest of the intruder alarm
system.
Functions additional to the mandatory functions specified in this standard may be included in the detector,
providing they do not adversely influence the correct operation of the mandatory functions.
The number and scope of these signals or messages may be more comprehensive for systems that are
specified at the higher grades.
This Technical Specification is only concerned with the requirements and tests for the detector. Other types
of detectors are covered by other documents identified as EN 50131-2-X / CLC/TS 50131-2-X.
__________

---------------------- Page: 4 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
– 3 – CLC/TS 50131-2-7-2:2009
Contents
1 Scope . 5
2 Normative references . 5
3 Terms, definitions and abbreviations . 6
3.1 Terms and definitions . 6
3.2 Abbreviations . 6
4 Functional requirements . 7
4.1 Event processing . 7
4.2 Operational requirements . 8
4.3 Detection . 9
4.4 Immunity to false alarm sources . 10
4.5 Tamper security . 10
4.6 Electrical requirements . 12
4.7 Environmental classification and conditions . 12
5 Marking, identification and documentation . 13
5.1 Marking and/or identification . 13
5.2 Documentation . 13
6 Testing . 13
6.1 General test conditions . 13
6.2 Basic detection test . 14
6.3 Performance tests . 14
6.4 Switch-on delay, time interval between signals and indication of detection . 16
6.5 Fault condition signals or messages: self tests . 16
6.6 Tests of immunity to false alarm sources . 17
6.7 Tamper security . 20
6.8 Electrical tests . 21
6.9 Environmental classification and conditions . 22
6.10 Marking, identification and documentation . 23
Annex A (normative) Catalogue of standard glass types . 24
Annex B (normative) List of small tools suitable for testing immunity of casing to attack . 25
Annex C (normative) Dimensions & requirements of a standard test magnet . 26
C.1 Normative references . 26
C.2 Requirements . 26
Annex D (normative) Immunity test: Small objects hit sensitivity . 29
Annex E (normative) Immunity test: Soft objects hit sensitivity . 30
Annex F (normative) Immunity test: Hard objects hit sensitivity . 31
Annex G (normative) Immunity test: Static pressure sensitivity . 32
Annex H (normative) Immunity test: Dynamic pressure sensitivity . 33
Annex I (normative) General testing matrix . 34
Annex J (normative) Performance test setup . 36
J.1 Performance test setup. 36
J.2 Alternative performance test setup . 37
Annex K (normative) Performance sensitivity test . 39

---------------------- Page: 5 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 4 –
Figures
Figure C.1 — Test magnet – Magnet type 1 . 27
Figure C.2 — Test magnet – Magnet type 2 . 28
Figure D.1 – Immunity test: Small objects hit sensitivity . 29
Figure E.1 – Immunity test: Soft objects hit sensitivity . 30
Figure F.1 – Immunity test: Hard objects hit sensitivity . 31
Figure G.1 – Immunity test: Static pressure sensitivity . 32
Figure H.1 – Immunity test: Dynamic pressure sensitivity . 33
Figure J.1 – Performance test setup . 36
Figure J.2 – Potential test setup . 38
Figure K.1 – Passive surface mounted glass break detectors test setup . 39

Tables
Table 1 – Events to be processed by grade . 7
Table 2 – Generation of indication signals or messages . 8
Table 3 – Performance test requirements . 9
Table 4 – Tamper security requirements . 11
Table 5 – Electrical requirements . 12
Table 6 – Operational tests . 23
Table 7 – Endurance tests . 23
Table A.1 – Standard glass types . 24
Table H.1 – General testing matrix . 34
Table J.1 . 37
Table J.2 . 37

---------------------- Page: 6 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
– 5 – CLC/TS 50131-2-7-2:2009
1 Scope
This Technical Specification is for passive surface mounted glass break detectors installed in buildings and
provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors
and uses environmental classes I to IV (see EN 50130-5). This Technical Specification does not include
requirements for passive surface mounted glass break detectors intended for use outdoors.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this standard may be included in the detector,
providing they do not adversely influence the correct operation of the mandatory functions.
This Technical Specification does not apply to system interconnections.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 50130-4 Alarm systems – Part 4: Electromagnetic compatibility – Product family standard:
Immunity requirements for components of fire, intruder and social alarm systems
EN 50130-5 Alarm systems – Part 5: Environmental test methods
EN 50131-1 Alarm systems – Intrusion and hold-up systems – Part 1: System requirements
EN 50131-6 Alarm systems – Intrusion and hold-up systems – Part 6: Power supplies
EN 60068-1:1994 Environmental testing – Part 1: General and guidance
(IEC 60068-1:1988 + corrigendum Oct. 1988 + A1:1992)
EN 60068-2-52:1996 Environmental testing -- Part 2: Tests - Test Kb: Salt mist, cyclic (sodium chloride
solution) (IEC 60068-2-52:1996)
EN 60529 Degrees of protection provided by enclosures (IP code) (IEC 60529)
EN ISO 527-1 Plastics – Determination of tensile properties – Part 1: General principles
(ISO 527-1)
EN ISO 527-2 Plastics – Determination of tensile properties – Part 2: Test conditions for
moulding and extrusion plastics (ISO 527-2)
EN ISO 1183 series Plastics – Methods for determining the density of non-cellular plastics
(ISO 1183 series)
EN ISO 2039-2 Plastics – Determination of hardness – Part 2: Rockwell hardness (ISO 2039-2)

---------------------- Page: 7 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 6 –
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50131-1 and the following apply.
3.1.1
glass breakage
physical destruction of a glass pane, which allows intrusion to the monitored area. For example in doors,
windows or enclosures
3.1.2
passive surface mounted glass break detector
detector that is mounted on a glass pane, which detects the energy emitted by a glass breakage of the pane
the detector is mounted on
3.1.3
basic test source
signal simulator designed to verify the basic function of the detector
3.1.4
incorrect operation
physical condition that causes an inappropriate signal or message from a detector
3.1.5
basic detection test
test whose purpose is to verify the operation of a detector after conditioning
3.1.6
masking
interference with the detector input capability such as an introduction of a physical barrier (e.g. metal, plastic,
paper or sprayed paints or lacquers in close proximity to the detector) or changing the characteristics of the
monitored area (e.g. placing wet newspapers on the outside of the monitored glass pane)
3.1.7
standard immunity glass pane
this glass pane will be used for all immunity tests, where a glass pane is needed, according to Annex A
3.1.8
simultaneous installation
an installation of more than one detector or sensor pair of one detector type (e.g. sender and receiver) for
one or more detector´s processing units
3.2 Abbreviations
For the purposes of this document, the abbreviations given in EN 50131-1 and the following apply.
BTS – Basic Test Source
EMC – ElectroMagnetic Compatibility

---------------------- Page: 8 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
– 7 – CLC/TS 50131-2-7-2:2009
4 Functional requirements
4.1 Event processing
Detectors shall process the events shown in Table 1. Detectors shall generate signals or messages as
shown in Table 2.
Table 1 – Events to be processed by grade
Event Grade 1 Grade 2 Grade 3 Grade 4
Intrusion M M M M
No stimulus M M M M
Masking Op Op M M
Tamper Op M M M
Low supply voltage Op Op M M
Total loss of power supply Op M M M
Local self test Op Op M M
Remote self test Op Op Op M
Key
M = Mandatory
Op = Optional

---------------------- Page: 9 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 8 –
Table 2 – Generation of indication signals or messages
Event Signals or messages
Intrusion Tamper Fault
Intrusion M NP NP
No stimulus NP NP NP
a
Masking M Op M
Tamper NP M NP
Low supply voltage Op Op M
b
Total loss of power supply M Op Op
Local self test pass NP NP NP
Local self test fail NP NP M
Remote self test pass M NP NP
Remote self test fail NP NP M
Key
M = Mandatory
NP = Not Permitted
Op = Optional
a
An independent masking signal or message may be provided instead.
NOTE 1 This permits two methods of signalling a masking event: either by the intrusion
signal and fault signal or by a dedicated masking signal or message. Use of the intrusion
signal and fault signal is preferable, as this requires fewer connections between CIE and
detector. If multiple events overlap there will be some signal combinations that may be
ambiguous. To overcome this ambiguity it is suggested that detectors should not signal
‘intrusion’ and ‘fault’ at the same time except to indicate masking. This implies that the
detector should prioritise signals, e.g. 1 Intrusion, 2 Fault, 3 Masking.
b
Alternatively total loss of power supply shall be determined by loss of communication with
the detector.
NOTE 2 When, in Table 1, an event may optionally generate signals or messages, they shall
be as shown in this table.

4.2 Operational requirements
4.2.1 Time interval between intrusion signals or messages
Wired detectors shall be able to provide an intrusion signal or message not more than 15 s after the end of
the preceding intrusion signal or message.
Wire free detectors shall be able to provide an intrusion signal or message after the end of the preceding
intrusion signal or message within the following times:
– grade 1 300 s;
– grade 2 180 s;
– grade 3 30 s;
– grade 4 15 s.
4.2.2 Switch on delay
The detector shall meet all functional requirements within 180 s of the power supply reaching its nominal
voltage as specified by the manufacturer.

---------------------- Page: 10 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
– 9 – CLC/TS 50131-2-7-2:2009
4.2.3 Self tests
4.2.3.1 Local self test
The detector shall automatically test itself at least once every 24 h according to the requirements of Tables 1
and 2. If normal operation of the detector is inhibited during a local self-test, the detector inhibition time shall
be limited to a maximum of 30 s in any period of 2 h.
4.2.3.2 Remote self test
A detector shall process remote self tests and generate signals or messages in accordance with Tables 1
and 2 within 10 s of the remote self test signal being received and shall return to normal operation within 30 s
of the remote test signal being received.
4.3 Detection
4.3.1 Detection performance
The detector shall generate an intrusion signal or message when a simulated or real glass breakage
according to the corresponding requirements of Table 3 is performed.
Table 3 – Performance test requirements
Requirement Grade 1 Grade 2 Grade 3 Grade 4
Verification of detection performance M M M M
Performance test: hole drilling with Op Op Op M
diamond hole saw
Performance test: glass cutting Op Op Op M
Key
M = Mandatory
Op = Optional

4.3.1.1 Verification of detection performance
This test will verify the detection performance for sensitivity and a break through the glass according to the
supported conditions claimed by the manufacturer. It will verify the maximum covering range (sensitivity
performance test) and the break through detection (breakage performance test), according to Annex A for
different glass types and sizes claimed to be supported (types and dimensions) by the manufacturer.
A number of standard glass types and sizes need to be passed by this test according to the corresponding
test section.
4.3.1.2 Performance test for hole drilling with a diamond hole saw
This test will verify the detection performance by drilling a hole using a diamond hole saw on different glass
types and dimensions according to the supported conditions claimed by the manufacturer and Annex A.
It will verify if the detector is able to identify and signal the change of the integrity of the monitored side of the
glass pane.
4.3.1.3 Performance test for glass cutting
This test will verify the detection performance by cutting the glass using a standard glass cutter on different
glass types and dimensions according to the supported conditions claimed by the manufacturer and
Annex A. It will verify if the detector is able to identify and signal the change of the integrity of the monitored
side of the glass pane.

---------------------- Page: 11 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 10 –
4.3.2 Indication of detection
Powered detectors at grades 3 and 4 that include processing capabilities shall provide an indicator at the
detector to indicate when an intrusion signal or message has been generated. Self-powered detectors (e.g.
detectors which rely on the energy resulting from the glass breakage) do not require such an indicator.
At grades 3 and 4 this indicator shall be capable of being enabled and disabled remotely at access level 2.
4.4 Immunity to false alarm sources
The detector shall have sufficient immunity to false alarm sources if the following requirements have been
met. No intrusion signal or message shall be generated as a result of the false alarm sources according to
each individual test clause.
The tests for this clause will be performed on the standard immunity test glass pane as defined in 3.1.7,
wherever a glass pane is required.
4.4.1 Immunity to small objects hitting the glass
The detector shall not generate an intrusion signal or message when small objects such as hail, sand, gravel
etc. hit the outside of the monitored glass. The tests are described in 6.6.1.
4.4.2 Immunity to soft objects hitting the glass
The detector shall not generate an intrusion signal or message when soft objects (e.g. a human fist) hit the
outside of the monitored glass. The tests are described in 6.6.2.
4.4.3 Immunity to hard objects hitting the glass
The detector shall not generate an intrusion signal or message when hard objects (e.g. handlebars of a
bicycle) hit the outside of the monitored glass. The tests are described in 6.6.3.
4.4.4 Immunity to static pressure
The detector shall not generate an intrusion signal or message when permanent pressure changes applied
to the monitored glass. The tests are described in 6.6.4.
4.4.5 Immunity to dynamic pressure
The detector shall not generate an intrusion signal or message when dynamic pressure changes (due to
wind, etc.) applied to the monitored glass. The tests are described in 6.6.5.
4.4.6 Immunity to wide band noise
The detector shall not generate an intrusion signal or message when a wide band of frequencies at the same
time, which are close to the frequency of a glass breakage (e.g. branches of a tree moving against the
window) are applied to the detector. The tests are described in 6.6.6.
4.5 Tamper security
Tamper security requirements for each grade of a detector are shown in Table 4.

---------------------- Page: 12 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
– 11 – CLC/TS 50131-2-7-2:2009
Table 4 – Tamper security requirements
Requirement Grade 1 Grade 2 Grade 3 Grade 4
Resistance to access to the inside of the detector M M M M
Detection of access to the inside of the detector Op M M M
a
Removal from the mounting surface Op M M M
Detection of masking Op Op M M
Magnetic field immunity Op M M M
Magnet type defined in Annex C – Type 1 Type 2 Type 2
Key
M = Mandatory
Op = Optional
a
Required for wire free detectors only.

4.5.1 Resistance to and detection of unauthorised access to the inside of the detector through covers
and existing holes
All components and means of adjustment which, when interfered with, could adversely affect the operation of
the detector, shall be located within the detector housing. Such access shall require the use of an
appropriate tool and depending on the grade as specified in Table 4 shall generate a tamper signal or
message before access can be gained.
It shall not be possible to gain access without generating a tamper signal or message or causing visible
damage.
4.5.2 Detection of removal from the mounting surface
A tamper signal or message shall be generated if the detector is removed from its mounting surface, in
accordance with Table 4.
4.5.3 Detection of masking
Means shall be provided to detect inhibition of the operation of the detector by masking according to the
requirements of Table 4. Alternatively, the detector shall continue to operate normally.
NOTE 1 In an I&HAS, any masked detectors should prevent setting of the system.
The maximum response time for the masking detection device shall be 180 s. Masking shall be signalled
according to the requirements of Table 2. The signals or messages shall remain for at least as long as the
masking condition is present. A masking signal or message shall not be reset while the masking condition is
still present. Alternatively the masking signal or message shall be generated again within 180 s of being
reset if the masking condition is still present.
NOTE 2 From a system design point of view, it would be preferable for masked detectors to automatically reset after the masking
condition is removed.
The detection of masking shall operate when the I&HAS is both set and unset.
4.5.4 Immunity to magnetic field interference
It shall not be possible to inhibit any signals or messages with a magnet of grade dependence according to
Table 4. The magnet types shall be as described in Annex C.

---------------------- Page: 13 ----------------------

SIST-TS CLC/TS 50131-2-7-2:2009
CLC/TS 50131-2-7-2:2009 – 12 –
4.6 Electrical requirements
These requirements do not apply to detectors having type C power supplies. For these detectors refer to
EN 50131-6. For detectors having an external power supply, the requirements appear in Table 5.
Table 5 – Electrical requirements
Test Grade 1 Grade 2 Grade 3 Grade 4
Detector current consumption Required Required Required Required
Input voltage range Required Required Required Required
Slow input voltage rise Not Required Required Required Required
Input voltage ripple Not required Re
...