Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector

Specifies: dimensions and tolerances of the interface features; port identification; identification of the result of operator actuation; dimensions, tolerances, and specifications for connector mateability. Does not apply to the functional characteristics of interfaces. The informative annex A contains the bibliography.

Transmissions pneumatiques -- Distributeurs à cinq orifices principaux -- Partie 2: Plans de pose avec connecteur électrique facultatif

Fluidna tehnika - Pnevmatika - Petpotni ventili - 2. del: Priključne površine z električnimi priključki

General Information

Status
Withdrawn
Publication Date
31-Jan-1997
Withdrawal Date
30-Jun-2002
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-Jul-2002
Due Date
01-Jul-2002
Completion Date
01-Jul-2002

Relations

Buy Standard

Standard
ISO 5599-2:1990 - Pneumatic fluid power -- Five-port directional control valves
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 5599-2:1997
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 5599-2:1990 - Transmissions pneumatiques -- Distributeurs a cinq orifices principaux
French language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 5599-2:1990 - Transmissions pneumatiques -- Distributeurs a cinq orifices principaux
French language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL
Is0
STANDARD
5599-2
First edition
1990-01-15
Pneumatic fluid power - Five-port directional
control valves -
Part 2:
Mounting interface surfaces with optional electrical
connector
Transmissions pneuma tiques - Distribu teurs Ei cinq orifices principaux -
Partie 2: Plans de pose avec connecteur klectrique facuitatif
Reference number
IS0 5599-Z : 1990 (El

---------------------- Page: 1 ----------------------
IS0 5599-2: 1990 (E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Each member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work. IS0
collaborates closely with the International Electrotechnical Commission (IEC) on all
matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 5599-Z was prepared by Technical Committee ISO/TC 131,
Fluid power systems.
This first edition of IS0 5599-2 cancels and replaces the first edition of
IS0 5599-l : 1978, of which it constitutes a technical revision in part.
IS0 5599-l : 1978 specified requirements both for mounting interface surfaces without
electrical connector and for mounting interface surfaces with optional electrical con-
nector. This part of IS0 5599 specifies requirements for mounting interface surfaces
with optional electrical connector only. Part 1 specifies requirements for mounting
interface surfaces without electrical connector.
IS0 5599 consists of the following parts, under the general title Pneumatic fluid
- Five-port directional control valves - Mounting interface surfaces :
power
-
Part 7: Mounting interface surfaces without electrical connector
-
Part 2: Mounting interface surfaces with optional electrical connector
-
Part 3: Code system for communication of valve functions
Annex A of this part of IS0 5599 is for information only.
0 IS0 1990
All rights reserved. No part of this publication may be reproduced or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in
writing from the publisher.
International Organization for Standardization
Case postale 56 l CH-1211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
IS0 5599-2 : 1990 (E)
Introduction
In pneumatic fluid power systems, power transmitted and controlled
through gas
under pressure within an enclosed
circuit.
The various devices for gas distribution and control can be either mounted directly
onto the pipeline, or mounted on interface surfaces, allowing quicker dismantling and
promoting equipment interchangeability.
Pneumatic directional control valves of the five-port, four-way type, mounted on inter-
face surfaces complying with the requirements of this part of IS0 5599 control the flow
of compressed gas. When the valve is electrically operated, it may be desirable to use
an electrical connector at the interface of the valve body and sub-base. Users of
pneumatic valves benefit when this electrical connector is standardized, allowing easy
electrical connection interchangeability between valves produced by different manu-
facturers.
Standardization of port and orifice identification, the result of operator actuation and a
system of dimensional tolerances are provided to enhance mounting interchangeability
of pneumatic control valves used on the mounting interface surfaces complying with
the requirements of this part of IS0 5599.
. . .
III

---------------------- Page: 3 ----------------------
This page intentionally left blank

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD IS0 5599-2 : 1990 (E)
Pneumatic fluid power - Five-port directional control
valves -
Part 2:
Mounting interface surfaces with optional electrical connector
1 Scope 3 Definitions
For the purposes of this part of IS0 5599, the definitions given
This part of IS0 5599 is applicable to mounting interface sur-
in IS0 5598, together with the following, apply.
faces and electrical connectors for five-port pneumatic direc-
tional control valves for a maximum working pressure of
3.1 electrical connector: A device consisting of two parts
1,6 MPa [I6 bat-J)]. It specifies
(contact and housing) which, when they are joined, provide
electrical and mechanical continuity.
- dimensions and tolerances of the interface features;
3.2 contact: A current-carrying component used at a
- port identification;
removable junction of an electric circuit.
-
identification of the result of operator actuation;
3.3 socket: A contact with an opening or hollow designed
to be the mechanical holder of a pin-type contact.
- dimensions, tolerances and specifications for optional
interface electrical connector mateability.
3.4 pin: A pointed contact designed to mate with a socket
contact.
It does not apply to the functional characteristics of interfaces.
3.5 housing: A device designed to orient, secure and
insulate contacts.
2 Normative references
4 Dimensional requirements and tolerances
The following standards contain provisions which, through
reference in this text, constitute provisions of this part of
4.1 Dimensional requirements for sizes 1 E, 2E and 3E are
IS0 5599. At the time of publication, the editions indicated
shown in figure 1 and given in table 1.
were valid. All standards are subject to revision, and parties to
agreements based on this part of IS0 5599 are encouraged to
Dimensional requirements for sizes 4E, 5E and 6E are
4.2
investigate the possibility of applying the most recent editions
shown in figure 2 and given in table 2.
of the standards listed below. Members of IEC and IS0 main-
tain registers of currently valid International Standards.
4.3 The main dimensions and tolerances of form and location
of the interface features are shown in figures 3, 4, 5 and 6, and
IS0 468 : 1982, Sutiace roughness - Parameters, their values
given in table 3.
and general rules for specifying requirements.
4.4 Tolerances on surface condition, withir the continuous
IS0 1101 : 1983, Technical drawings - Geometrical toleranc-
line, shall be as follows:
ing - Tolerancing of form, orientation, location and run-out -
- Surface roughness: 1,6 pm (class N7)
see IS0 468 and
Generalities, definitions, symbols, indications on drawings.
IS0 1302)
IS0 1302 : 1978, Technical drawings - Method of indicating
- Surface flatness : 0,l mm over a dist lnce of 100 mm
surface texture on drawings.
(see IS0 1101)
I
IS0 5598 : 1985, Fluid power systems and components -
p~o,l/loo f
Vocabulary.
1) 1 bar = 0,l MPa = 105 N/m2

---------------------- Page: 5 ----------------------
4.5 The mounting surface shall not include any orifices other 6.3 Contacts
than those shown on the figures. All passages shown in the
interface shall be included, and connected to open ports in the 6.3.1 Connectors shall comprise four live contacts and one
sub-base.
earth contact. The earth contact shall make first and break last.
It shall be 1,5 mm longer than the other contacts.
6.3.2 The pins shall have diameters of 2,03 mm to 2,18 mm.
5 Identification of ports and orifices
6.3.3 Socket contacts shall have an opening diameter that
5.1 The flow path orifices in the mounting surface interface, allows friction fits on the pin contacts.
and the ports serving these orifices, shall be designated as
follows (see figures 4 and 6) :
6.4 Insulation
-
ports 1, 2, 3, 4 and 5 are the principal flow paths;
6.4.1 Wire of sectional area 0,75 mm* to 2,5 mm* shall be
used.
-
ports 12 and 14 are the actuation orifices.
NOTE - Port 14 is preferred for single-source external solenoid
6.4.2 Same-colour insulation on diagonally opposite leads
pilot supply.
shall be used.
5.2 For monostable valves, the mandatory stable position of 6.4.3 Green insulation shall identify the
...

SLOVENSKI STANDARD
SIST ISO 5599-2:1997
01-februar-1997
)OXLGQDWHKQLND3QHYPDWLND3HWSRWQLYHQWLOLGHO3ULNOMXþQHSRYUãLQH]
HOHNWULþQLPLSULNOMXþNL
Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface
surfaces with optional electrical connector
Transmissions pneumatiques -- Distributeurs à cinq orifices principaux -- Partie 2: Plans
de pose avec connecteur électrique facultatif
Ta slovenski standard je istoveten z: ISO 5599-2:1990
ICS:
23.100.50 Krmilni sestavni deli Control components
SIST ISO 5599-2:1997 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 5599-2:1997

---------------------- Page: 2 ----------------------

SIST ISO 5599-2:1997
INTERNATIONAL
Is0
STANDARD
5599-2
First edition
1990-01-15
Pneumatic fluid power - Five-port directional
control valves -
Part 2:
Mounting interface surfaces with optional electrical
connector
Transmissions pneuma tiques - Distribu teurs Ei cinq orifices principaux -
Partie 2: Plans de pose avec connecteur klectrique facuitatif
Reference number
IS0 5599-Z : 1990 (El

---------------------- Page: 3 ----------------------

SIST ISO 5599-2:1997
IS0 5599-2: 1990 (E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Each member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work. IS0
collaborates closely with the International Electrotechnical Commission (IEC) on all
matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 5599-Z was prepared by Technical Committee ISO/TC 131,
Fluid power systems.
This first edition of IS0 5599-2 cancels and replaces the first edition of
IS0 5599-l : 1978, of which it constitutes a technical revision in part.
IS0 5599-l : 1978 specified requirements both for mounting interface surfaces without
electrical connector and for mounting interface surfaces with optional electrical con-
nector. This part of IS0 5599 specifies requirements for mounting interface surfaces
with optional electrical connector only. Part 1 specifies requirements for mounting
interface surfaces without electrical connector.
IS0 5599 consists of the following parts, under the general title Pneumatic fluid
- Five-port directional control valves - Mounting interface surfaces :
power
-
Part 7: Mounting interface surfaces without electrical connector
-
Part 2: Mounting interface surfaces with optional electrical connector
-
Part 3: Code system for communication of valve functions
Annex A of this part of IS0 5599 is for information only.
0 IS0 1990
All rights reserved. No part of this publication may be reproduced or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in
writing from the publisher.
International Organization for Standardization
Case postale 56 l CH-1211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 4 ----------------------

SIST ISO 5599-2:1997
IS0 5599-2 : 1990 (E)
Introduction
In pneumatic fluid power systems, power transmitted and controlled
through gas
under pressure within an enclosed
circuit.
The various devices for gas distribution and control can be either mounted directly
onto the pipeline, or mounted on interface surfaces, allowing quicker dismantling and
promoting equipment interchangeability.
Pneumatic directional control valves of the five-port, four-way type, mounted on inter-
face surfaces complying with the requirements of this part of IS0 5599 control the flow
of compressed gas. When the valve is electrically operated, it may be desirable to use
an electrical connector at the interface of the valve body and sub-base. Users of
pneumatic valves benefit when this electrical connector is standardized, allowing easy
electrical connection interchangeability between valves produced by different manu-
facturers.
Standardization of port and orifice identification, the result of operator actuation and a
system of dimensional tolerances are provided to enhance mounting interchangeability
of pneumatic control valves used on the mounting interface surfaces complying with
the requirements of this part of IS0 5599.
. . .
III

---------------------- Page: 5 ----------------------

SIST ISO 5599-2:1997
This page intentionally left blank

---------------------- Page: 6 ----------------------

SIST ISO 5599-2:1997
INTERNATIONAL STANDARD IS0 5599-2 : 1990 (E)
Pneumatic fluid power - Five-port directional control
valves -
Part 2:
Mounting interface surfaces with optional electrical connector
1 Scope 3 Definitions
For the purposes of this part of IS0 5599, the definitions given
This part of IS0 5599 is applicable to mounting interface sur-
in IS0 5598, together with the following, apply.
faces and electrical connectors for five-port pneumatic direc-
tional control valves for a maximum working pressure of
3.1 electrical connector: A device consisting of two parts
1,6 MPa [I6 bat-J)]. It specifies
(contact and housing) which, when they are joined, provide
electrical and mechanical continuity.
- dimensions and tolerances of the interface features;
3.2 contact: A current-carrying component used at a
- port identification;
removable junction of an electric circuit.
-
identification of the result of operator actuation;
3.3 socket: A contact with an opening or hollow designed
to be the mechanical holder of a pin-type contact.
- dimensions, tolerances and specifications for optional
interface electrical connector mateability.
3.4 pin: A pointed contact designed to mate with a socket
contact.
It does not apply to the functional characteristics of interfaces.
3.5 housing: A device designed to orient, secure and
insulate contacts.
2 Normative references
4 Dimensional requirements and tolerances
The following standards contain provisions which, through
reference in this text, constitute provisions of this part of
4.1 Dimensional requirements for sizes 1 E, 2E and 3E are
IS0 5599. At the time of publication, the editions indicated
shown in figure 1 and given in table 1.
were valid. All standards are subject to revision, and parties to
agreements based on this part of IS0 5599 are encouraged to
Dimensional requirements for sizes 4E, 5E and 6E are
4.2
investigate the possibility of applying the most recent editions
shown in figure 2 and given in table 2.
of the standards listed below. Members of IEC and IS0 main-
tain registers of currently valid International Standards.
4.3 The main dimensions and tolerances of form and location
of the interface features are shown in figures 3, 4, 5 and 6, and
IS0 468 : 1982, Sutiace roughness - Parameters, their values
given in table 3.
and general rules for specifying requirements.
4.4 Tolerances on surface condition, withir the continuous
IS0 1101 : 1983, Technical drawings - Geometrical toleranc-
line, shall be as follows:
ing - Tolerancing of form, orientation, location and run-out -
- Surface roughness: 1,6 pm (class N7)
see IS0 468 and
Generalities, definitions, symbols, indications on drawings.
IS0 1302)
IS0 1302 : 1978, Technical drawings - Method of indicating
- Surface flatness : 0,l mm over a dist lnce of 100 mm
surface texture on drawings.
(see IS0 1101)
I
IS0 5598 : 1985, Fluid power systems and components -
p~o,l/loo f
Vocabulary.
1) 1 bar = 0,l MPa = 105 N/m2

---------------------- Page: 7 ----------------------

SIST ISO 5599-2:1997
4.5 The mounting surface shall not include any orifices other 6.3 Contacts
than those shown on the figures. All passages shown in the
interface shall be included, and connected to open ports in the 6.3.1 Connectors shall comprise four live contacts and one
sub-base.
earth contact. The earth contact shall make first and break last.
It shall be 1,5 mm longer than the other contacts.
6.3.2 The pins shall have diameters of 2,03 mm to 2,18 mm.
5 Identification of ports and orifices
6.3.3 Socket contacts shall have an opening diameter that
5.1 The flow path orifices in the mounting surface interface, allows friction fits on the pin contacts.
and the ports serving these orifices, shall be designated as
follows (see figures 4 and 6) :
6.4 Insulation
-
ports 1, 2, 3, 4 and 5 are the principal flow paths;
6.4.1 Wire
...

IS0
NORME
INTER NATIONALE
Première edition
1990-01 -1 5
Transmissions pneumatiques - Distributeurs à
cinq orifices principaux -
Partie 2 :
Plans de pose avec connecteur électrique facultatif
Pneumatic fluid power - Five-port directional control valves -
Part 2: Mounting interface surfaces with optional electrical connector
Numbro de reference
IS0 5599-2 : 1990 (FI

---------------------- Page: 1 ----------------------
I
IS0 5599-2 : 1990 (FI
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
des Normes internationales est en général confiée aux comités techniques de I'ISO.
Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I'ISO participent également aux travaux. L'ISO col-
labore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui
concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
le Conseil de I'ISO. Les Normes internationales sont approuvées confor-
nationales par
mément aux procédures de l'lS0 qui requièrent l'approbation de 75 % au moins des
comités membres votants.
La Norme internationale IS0 5599-2 a été élaborée par le comité technique
Transmissions hydrauliques et pneumatiques.
ISOITC 131,
Cette première édition de I'ISO 5599-2 annule et remplace la première édition de
I'ISO 5599-1 : 1978, dont elle constitue une révision technique partielle.
L'ISO 5599-1 : 1978 prescrivait les caractéristiques pour tes deux types de plan de pose,
sans et avec connecteur électrique. La présente partie de I'ISO 5599 prescrit unique-
ment les caractéristiques des plans de pose (( avec connecteur électrique facultatif ))
alors que les caractéristiques des plans de pose ((sans connecteur électrique)) font
l'objet de I'ISO 5599-1.
L'ISO 5599 comprend les parties suivantes, présentées sous le titre général Transmis-
sions pneumatiques - Distributeurs à cinq orifices principaux :
-
Partie I: Plans de pose sans connecteur hlectrique
-
Partie 2: Plans de pose avec connecteur hlectrique facultatif
-
Partie 3: Codification de l'information sur les fonctions des distributeurs
L'annexe A de la présente partie de I'ISO 5599 est donnée uniquement à titre d'infor-
mation.
O IS0 1990
Droits de reproduction rBservBs. Aucune partie de cette publication ne peut être reproduite ni
utilisBe sous quelque forme que ce soit et par aucun procBdB, Blectronique ou mBcanique,
y compris la photocopie et les microfilms, sans l'accord Bcrit de I'Bditeur.
Organisation internationale de normalisation
Case postale 56 CH-1211 Genhve 20 Suisse
tmprirnr5 en Suisse
II

---------------------- Page: 2 ----------------------
Introduction
Dans les systèmes de transmissions pneumatiques, l’énergie est transmise et comman-
dée par l‘intermédiaire d’un gaz sous pression circulant dans un circuit.
Les différents appareils destinés à la distribution et A la régulation du gaz peuvent être
montés soit directement sur les tuyauteries, soit sur des plans de pose permettant un
démontage plus rapide et favorisant l‘interchangeabilité des appareils.
Les distributeurs B cinq orifices et quatre voies utilisés sur les plans de pose conformes
aux exigences de la présente partie de I‘ISO 5599 contrôlent le passage du gaz com-
primé.
Lorsque l‘appareil est actionné électriquement, il peut être souhaitable d’intercaler un
connecteur électrique entre le corps de l‘appareil et l’embase. Les usagers des appareils
Pneumatiques ne peuvent que bénéficier de la normalisation de ce connecteur électri-
que qui assure plus facilement l’interchangeabilité des raccordements entre appareils
de fabrications diverses.
La normalisation du repérage des orifices principaux, des effets de la commande du
distributeur et des tolérances dimensionnelles devrait améliorer l’interchangeabilité
géométrique des distributeurs pneumatiques utilisés sur les plans de pose conformes
aux exigences de la présente partie de I’ISO 5599.
iii

---------------------- Page: 3 ----------------------
NORME INTERNATIONALE IS0 5599-2 : 1990 (FI
Transmissions pneumatiques - Distributeurs à cinq
orifices principaux -
Partie 2:
Plans de pose avec connecteur électrique facultatif
1 Domaine d‘application 3 Définitions
Pour les besoins de la présente partie de I‘ISO 5599, les défini-
La présente partie de I‘ISO 5599 s’applique aux plans de pose et
tions données dans I’ISO 5598 et les définitions suivantes
aux connecteurs électriques des distributeurs à cinq orifices
s’appliquent.
principaux pour transmissions pneumatiques utilisés sous une
pression maximale de service de 1,6 MPa [16 bar’)]. Elle prescrit
3.1 connecteur électrique : Appareil composé de deux piè-
-
les dimensions et les tolérances des éléments situés à
ces (contact et boîtier) qui, lorsqu’elles sont jointes, assurent
l‘interface;
une continuité électrique et mécanique.
-
le repérage des orifices principaux;
contact: Elément porteur de courant utilisé à la jonction
3.2
-
le repérage des effets de la commande du distributeur;
détachable d’un circuit électrique.
-
les dimensions, tolérances et caractéristiques d’inter-
3.3 support: Contact femelle ayant une ouverture ou un
changeabilité du connecteur électrique facultatif.
à servir de support mécanique à un contact mâle
creux destiné
Elle ne s‘applique pas aux caractéristiques fonctionnelles des (broche).
plans de pose.
3.4 broche : Contact mâle en pointe destiné à s‘accoupler à
un contact femelle de la fiche.
2 Références normatives
3.5 boîtier : Système destiné à orienter, à fixer et à isoler les
Les normes suivantes contiennent des dispositions qui, par
contacts.
suite de la référence qui en est faite, constituent des disposi-
tions valables pour la présente partie de I’ISO 5599. Au moment
de la publication, les éditions indiquées étaient en vigueur.
4 Caractéristiques dimensionnelles
Toute norme est sujette à révision et les parties prenantes des
et tolérances
accords fondés sur la présente partie de I‘ISO 5599 sont invi-
tées à rechercher la possibilité d’appliquer les éditions les plus
récentes des normes indiquées ci-après. Les membres de la CE1 4.1 Les caractéristiques dimensionnelles des plans de pose
de tailles lE, 2E et 3E sont représentéesà la figure 1 et données
et de I’ISO possèdent le registre des Normes internationales en
dans le tableau 1.
vigueurà un moment donné.
IS0 468 : 1982, Rugosité de surface - Paramètres, leurs
4.2 Les caractéristiques dimensionnelles des plans de pose
valeurs et les règles générales de la détermination des spécifica-
de tailles 4E, 5E et 6E sont représentées A la figure 2 et données
tions.
dans le tableau 2.
IS0 1101 1 1983, Dessins techniques - Tolérancementgéomé-
4.3 Les dimensions et tolérances de forme et de localisation à
trique - Tolbrancement de forme, orientation, position et bat-
appliquer aux éléments situés à l‘interface sont représentées
tement - Généralités, définitions, symboles, indications sur les
aux figures 3, 4, 5 et 6 et données dans le tableau 3.
dessins.
IS0 1302 : 1978, Dessins techniques - Indications des états
4.4 La planéité de la rugosité de surface de l’aire délimitée par
de surface sur les dessins.
les traits continus doivent être comme suit :
-
IS0 5598 1 1985, Transmissions hydrauliques et pneumatiques Rugosité, Ra: 1,6 pm (classe N7) (voir IS0 468 et
- Vocabulaire.
IS0 1302)
1 bar = 0.1 MPa = 105 N/mz
1)
1

---------------------- Page: 4 ----------------------
IS0 5599-2 : 1990 (FI
-
Planéité: 0,l mm sur une longueur de 100 mm (voir
6.2.3 Des connecteurs ayant une isolation appropriée à une
IS0 1101) tension nominale de 300 V (volts) et à une température de
105 OC doivent être utilisés.
6.3 Contacts
6.3.1 Quatre contacts sous tension et un contact de mise à la
4.5 Les plans de pose ne doivent présenter aucune autre
terre doivent être utilisés. Le contact de mise à la terre doit être
ouverture que celles représentées sur les figures. Tous les pas-
le premier établi et le dernier coupé (différence de longueur:
sages indiqués dans les plans de pose doivent exister et être
1,5 mm).
à des orifices ouverts.
raccordés
...

IS0
NORME
INTERNATIONALE
Première édition
1990-01 -1 5
Transmissions pneumatiques - Distri buteurs à
cinq orifices principaux -
Partie 2 :
Plans de pose avec connecteur électrique facultatif
Pneumatic fluid power - Five-port directional control valves -
Part 2: Mounting interface surfaces with optional electrical connector
~~
~~~
Numéro de référence
IS0 5599-2 : 1990 (FI

---------------------- Page: 1 ----------------------
I
IS0 5599-2 : 1990 (FI
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
des Normes internationales est en général confiée aux comités techniques de I'ISO.
Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé 8 cet effet. Les organisations internationales, gouvernementales et non
I'ISO participent également aux travaux. L'ISO col-
gouvernementales, en liaison avec
labore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui
concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I'ISO. Les Normes internationales sont approuvées confor-
mément aux procédures de I'ISO qui requièrent l'approbation de 75 YO au moins des
comités membres votants.
La Norme internationale IS0 5599-2 a été élaborée par le comité technique
ISOITC 131, Transmissions hydrauliques et pneumatiques.
Cette première édition de I'ISO 5599-2 annule et remplace la première édition de
I'ISO 5599-1 : 1978, dont elle constitue une révision technique partielle.
L'ISO 5599-1 : 1978 prescrivait les caractéristiques pour les deux types de plan de pose,
sans et avec connecteur Blectrique. La présente partie de I'ISO 5599 prescrit unique-
ment les caractéristiques des plans de pose (( avec connecteur Blectrique facultatif ))
alors que les caractéristiques des plans de pose ((sans connecteur électriquen font
I'ISO 5599-1.
l'objet de
L'ISO 5599 comprend les parties suivantes, présentées sous le titre général Transmis-
sions pneumatiques - Distributeurs à cinq orifices princpaux:
-
Partie 1 : Plans de pose sans connecteur dectrique
-
Partie 2: Plans de pose avec connecteur Blectrique facultatif
-
Partie 3: Codification de l'information sur les fonctions des distributeurs
L'annexe A de la présente partie de I'ISO 5599 est donnée uniquement a titre d'infor-
mation.
O IS0 1990
Droits de reproduction rBservBs. Aucune partie de cette publication ne peut &re reproduite ni
utilisBe sous quelque forme que ce soit et par aucun procBd6, Blectronique ou mBcanique,
y compris la photocopie et les microfilms, sans l'accord Bcrit de 1'6diteur.
Organisation internationale de normalisation
Case postale 56 O CH-121 1 Genbve 20 O Suisse
Imprime en Suisse
II

---------------------- Page: 2 ----------------------
Introduction
Dans les systemes de transmissions pneumatiques, l'énergie est transmise et comman-
dée par l'intermédiaire d'un gaz sous pression circulant dans un circuit.
Les différents appareils destinés à la distribution et à la régulation du gaz peuvent être
montés soit directement sur les tuyauteries, soit sur des plans de pose permettant un
démontage plus rapide et favorisant l'interchangeabilité des appareils.
Les distributeurs à cinq orifices et quatre voies utilisés sur les plans de pose conformes
aux exigences de la présente partie de I'ISO 5599 contrôlent le passage du gaz com-
primé.
Lorsque l'appareil est actionné électriquement, il peut être souhaitable d'intercaler un
connecteur électrique entre le corps de l'appareil et l'embase. Les usagers des appareils
pneumatiques ne peuvent que bénéficier de la normalisation de ce connecteur électri-
que qui assure plus facilement l'interchangeabilité des raccordements entre appareils
de fabrications diverses.
La normalisation du repérage des orifices principaux, des effets de la commande du
distributeur et des tolérances dimensionnelles devrait améliorer l'interchangeabilité
géométrique des distributeurs pneumatiques utilisés sur les plans de pose conformes
aux exigences de la présente partie de I'ISO 5599.
iii

---------------------- Page: 3 ----------------------
IS0 5599-2 : 1990 (FI
NOR M E I NTE R NAT1 O NA LE
Transmissions pneumatiques - Distributeurs à cinq
orifices principaux -
Partie 2:
Plans de pose avec connecteur électrique facultatif
1 Domaine d‘application 3 Définitions
Pour les besoins de la présente partie de I’ISO 5599, les défini-
La présente partie de I‘ISO 5599 s’applique aux plans de pose et
tions données dans I‘ISO 5598 et les définitions suivantes
aux connecteurs électriques des distributeurs à cinq orifices
s’appliquent.
principaux pour transmissions pneumatiques utilisés sous une
pression maximale de service de 1,6 MPa [16 barl)]. Elle prescrit
3.1 connecteur électrique : Appareil composé de deux piè-
-
les dimensions et les tolérances des éléments situés a
ces (contact et boîtier) qui, lorsqu’elles sont jointes, assurent
l’interface;
une continuité électrique et mécanique.
-
le repérage des orifices principaux;
3.2 contact: Élément porteur de courant utilisé à la jonction
-
le repérage des effets de la commande du distributeur;
détachable d‘un circuit électrique.
-
les dimensions, tolérances et caractéristiques d’inter-
3.3 support: Contact femelle ayant une ouverture ou un
changeabilité du connecteur électrique facultatif.
creux destiné à servir de support mécanique à un contact mâle
Elle ne s‘applique pas aux caractéristiques fonctionnelles des (broche).
plans de pose.
broche : Contact mâle en pointe destiné à s‘accoupler à
3.4
un contact femelle de la fiche.
2 Références normatives
boîtier : Système destiné à orienter, à fixer et à isoler les
3.5
Les normes suivantes contiennent des dispositions qui, par
contacts.
suite de la référence qui en est faite, constituent des disposi-
tions valables pour la présente partie de I‘ISO 5599. Au moment
de la publication, les éditions indiquées étaient en vigueur.
4 Caractéristiques dimensionnelles
Toute norme est sujette à révision et les parties prenantes des
et tolérances
accords fondés sur la présente partie de l’lS0 5599 sont invi-
tées à rechercher la possibilité d’appliquer les éditions les plus
4.1 Les caractéristiques dimensionnelles des plans de pose
récentes des normes indiquées ci-après. Les membres de la CE1
de tailles 1 E, 2E et 3E sont représentées à la figure 1 et données
et de I’ISO possèdent le registre des Normes internationales en
dans le tableau 1.
vigueur à un moment donné.
IS0 468 : 1982, Rugosité de surface - Paramètres, leurs
4.2 Les caractéristiques dimensionnelles des plans de pose
valeurs et les règles générales de la détermination des spécifica-
4E, 5E et 6E sont représentées à la figure 2 et données
de tailles
tions.
dans le tableau 2.
IS0 1101 : 1983, Dessins techniques - Tolérancement géomé-
4.3 Les dimensions et tolérances de forme et de localisation à
- Tolérancement de forme, orientation, position et bat-
trique
appliquer aux éléments situés à l’interface sont représentées
tement - Généralités, définitions, symboles, indications sur les
aux figures 3, 4, 5 et 6 et données dans le tableau 3.
dessins.
IS0 1302 : 1978, Dessins techniques - Indications des états
4.4 La planéité de la rugosité de surface de l’aire délimitée par
de surface sur les dessins.
les traits continus doivent être comme suit :
-
IS0 5598 : 1985, Transmissions hydrauliques et pneumatiques Rugosité, Ra: 1,6 ym (classe N7) (voir IS0 468 et
- Vocabulaire. IS0 1302)
1 bar = 0.1 MPa = lO5N/mz
1)
1

---------------------- Page: 4 ----------------------
IS0 5599-2 : 1990 (FI
-
Planéité: 0,l mm sur une longueur de 100 mm (voir 6.2.3 Des connecteurs ayant une isolation appropriée à une
IS0 1101) tension nominale de 300 V (volts) et à une température de
105 OC doivent être utilisés.
6.3 Contacts
6.3.1 Quatre contacts sous tension et un contact de mise à la
4.5 Les plans de pose ne doivent présenter aucune autre
terre doivent être utilisés. Le contact de mise à la terre doit être
ouverture que celles représentées sur les figures. Tous les pas-
le premier établi et le dernier coupé (différence de longueur:
sages indiqués dans les plans de pose doivent exister et être
1.5 mm).
raccordés à des orifices ouver
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.