SIST EN 1319:2010
(Main)Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW
This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with a fan to assist the transportation of combustion air and/or combustion products, hereafter referred to as "appliances".
This European Standard applies to type B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, C12, C13, C32, C33, C62 and C63 appliances with an input not exceeding 70 kW (net cv basis), intended primarily for use in single unit residential dwellings. Provision of the heated air may be by means of ducting.
This European Standard does not contain all necessary requirements for :
a) appliances of the condensing type;
b) appliances for outdoor installation;
c) dual purpose air conditioning appliances (heating and cooling);
d) appliances where the air is heated by an intermediate fluid;
e) appliances with forced draught package burners or fully premixed burners;
f) appliances fitted with a manual means of adjusting the combustion air supply or the evacuation of the combustion products;
g) portable or transportable forced convection appliances;
h) appliances having multiple heating units with a single draught diverter;
i) appliances fitted with more than one flue outlet;
j) Type C22, C23, C42, C43, C52 and C53 appliances.
This European Standard covers type-testing only.
Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Räumen für den häuslichen Gebrauch, mit gebläseunterstützten Gasbrennern mit einer Nennwärmebelastung gleich oder kleiner als 70 kW
Diese Europäische Norm legt fest die Anforderungen an und Prüfverfahren für die Sicherheit und Leistungsfähigkeit gasbefeuerter Warmlufterzeuger für den häuslichen Gebrauch mit einem Gebläse zur Beförderung der Verbrennungsluft und/oder des Rauchgases (nachfolgend kurz "Geräte" genannt).
Diese Europäische Norm gilt für Geräte der Typen B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS B14BS, B22, B23, C12, C13, C32, C33, C62 und C63, deren Wärmebelastung 70 kW (bezogen auf den Heizwert) nicht übersteigt, und die hauptsächlich für den Gebrauch in aus nur einer Einheit bestehenden Wohnungen bestimmt sind. Die Abgabe der Warmluft kann durch Leitungen erfolgen.
Diese Norm enthält nicht alle notwendigen Anforderungen für:
a) Geräte mit Brennwertnutzung;
b) Geräte zur Aufstellung im Freien;
c) Doppelzweck-Klimaanlagen (zum Heizen und Kühlen);
d) Geräte, bei denen die Luft mittels einer Zwischenflüssigkeit erwärmt wird;
e) Geräte mit Gasbrennern mit Gebläse;
f) Geräte mit einer handbetätigten oder automatischen Einrichtung zur Einstellung der Verbrennungs¬luftzufuhr oder der Abgasabführung (einschließlich Abgasdrosselklappen);
g) tragbare oder transportable Geräte mit erzwungener Konvektion;
h) Geräte mit mehreren Heizelementen mit nur einer Strömungssicherung;
i) Geräte mit mehr als einem Abgasstutzen;
j) Geräte der Bauarten C22, C23, C42, C43, C52 und C53.
Die vorliegende Norm umfasst nur die Baumusterprüfung.
Générateurs d'air chaud à convection forcée utilisant les combustibles gazeux pour le chauffage de locaux à usage d'habitation, comportant des brûleurs avec ventilateur de débit calorifique inférieur ou égal à 70 kW (sur pouvoir calorifique inférieur)
La présente Norme européenne définit les exigences et les méthodes d’essai relatives à la sécurité et au rendement des générateurs d’air chaud à usage domestique fonctionnant au gaz comportant un ou plusieurs brûleurs avec ventilateur pour assister le transport de l’air de combustion et/ou des produits de combustion, appelés ci-après appareils.
La présente Norme européenne s’applique aux appareils de types B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS,B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 et C63 dont le débit calorifique est inférieur à 70 kW (sur PCI) et qui sont destinés en particulier à être utilisés dans l’habitat individuel. L’écoulement de l’air chaud peut se faire dans des canalisations ou directement dans l’espace à chauffer.
La présente Norme européenne ne contient pas toutes les exigences nécessaires pour examiner les appareils :
a) à condensation ;
b) destinés à être installés à l’extérieur ;
c) de climatisation à usage double (chauffage et refroidissement de l’air) ;
d) de chauffage de l’air par un fluide caloporteur intermédiaire ;
e) à équipement de chauffe à air soufflé ou équipés de brûleurs à prémélange total ;
f) comportant des moyens de réglage manuel de l’alimentation en air ou de l’évacuation des produits de combustion ;
g) portatifs ou transportables à convection forcée ;
h) comportant plusieurs modules de chauffage associés à un seul coupe-tirage antirefouleur ;
i) comportant plusieurs buses d’évacuation ;
j) des types C22, C23, C42, C43, C52 et C53 ;
k) conçus pour une condensation continue dans les conduits de fumées dans des conditions normales de fonctionnement ;
l) ayant des conduits d’évacuation des produits de combustion, POCEDs, qui ne sont pas métalliques.
Cette norme est applicable aux appareils destinés aux essais de types.
Plinski gospodinjski grelniki zraka s prisilno konvekcijo za gretje prostorov z ventilatorskimi gorilniki z imensko močjo do vključno 70 kW
Ta evropski standard določa zahteve in preskusne metode za varnost in učinkovitost plinskih gospodinjskih grelnikov zraka z ventilatorjem za zgorevalni zrak in/ali produkte izgorevanja, v nadaljevanju aparatov. Ta evropski standard velja za tipe aparatov B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 in C63 z dovodom, ki ne presega 70 kW (neto kalorična osnova), namenjene predvsem za uporabo v posameznih enotah stanovanjskih objektov. Preskrbovanje s segretim zrakom lahko poteka preko vodov. Ta standard velja za aparate, namenjene za tipsko preskušanje. Prav tako vsebuje zahteve glede ocenjevanja skladnosti, vključno s kontrolo proizvodnje, ki pa veljajo zgolj za POCEDs in z njimi povezane terminale.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Räumen für den häuslichen Gebrauch, mit gebläseunterstützten Gasbrennern mit einer Nennwärmebelastung gleich oder kleiner als 70 kWGénérateurs d'air chaud à convection forcée utilisant les combustibles gazeux pour le chauffage de locaux à usage d'habitation, comportant des brûleurs avec ventilateur de débit calorifique inférieur ou égal à 70 kW (sur pouvoir calorifique inférieur)Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW97.100.20Plinski grelnikiGas heatersICS:Ta slovenski standard je istoveten z:EN 1319:2009SIST EN 1319:2010en,fr,de01-februar-2010SIST EN 1319:2010SLOVENSKI
STANDARDSIST EN 1319:1999/A2:1999SIST EN 1319:1999/A1:2002SIST EN 1319:19991DGRPHãþD
SIST EN 1319:2010
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1319
December 2009 ICS 97.100.20 Supersedes EN 1319:1998English Version
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW
Générateurs d'air chaud à convection forcée utilisant les combustibles gazeux pour le chauffage de locaux à usage d'habitation, comportant des brûleurs avec ventilateur de débit calorifique inférieur ou égal à 70 kW (sur pouvoir calorifique inférieur)
Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Räumen für den häuslichen Gebrauch, mit gebläseunterstützten Gasbrennern mit einer Nennwärmebelastung gleich oder kleiner als 70 kW This European Standard was approved by CEN on 1 November 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1319:2009: ESIST EN 1319:2010
EN 1319:2009 (E) 2 Contents Page Foreword .41 Scope .62 Normative references .63 Terms and definitions .83.1 Appliance and its constituent parts .83.2 Adjustment, control and safety devices . 113.3 Operation of the appliance . 133.4 Gases . 163.5 Conditions of operation and measurement . 183.6 Marking of the appliance and packaging . 194 Classification of systems . 194.1 Classification according to the nature of the gases used (Categories). 194.2 Classification according to the gases capable of being used . 194.3 Classification according to the mode of evacuation of the combustion products . 215 Construction and design requirements . 235.1 General . 235.2 Adjusting, control and safety devices . 305.3 Ignition devices . 375.4 Flame supervision system . 375.5 Start-gas flame establishment . 385.6 Main flame establishment . 415.7 Main burner . 415.8 Facility for remote control . 415.9 Thermostats and control of air temperature . 425.10 Gas pressure test points . 426 Operational requirements . 436.1 Safety of operation . 436.2 Efficiency . 517 Test methods . 527.1 General . 527.2 Construction and design . 617.3 Safety of operation . 617.4 Efficiency . 918 Marking and instructions . 998.1 Marking of the appliance . 998.2 Marking of the packaging . 1008.3 Utilization of symbols on the appliance and packaging . 1018.4 Instructions . 1039 Evaluation of POCED conformity and their associated terminals . 1059.1 General . 1059.2 Type testing . 1059.3 Factory production control (FPC) . 106Annex A (informative)
National situations . 108A.1 General . 108A.2 Categories listed in the body of the standard and marketed in different countries . 108A.3 Appliance supply pressures corresponding to the categories given in A.2 . 110A.4 Special categories marketed nationally or locally . 111SIST EN 1319:2010
EN 1319:2009 (E) 3 A.5 Test gases corresponding to the special categories given in A.4 . 117A.6 Gas connections in the various countries . 120A.7 Flue connections in the various countries . 122Annex B (informative)
Equivalence rules . 123B.1 Conversion to categories within a restricted Wobbe index range . 123B.2 Conversion to categories within an identical Wobbe index range. 123B.3 Conversion to categories within a wider Wobbe index range . 124Annex C (normative)
Classification according to the evacuation of the combustion . 125C.1 Type B1 . 125C.2 Type B2 . 126C.3 Type B4 . 127C.4 Type B5 . 129C.5 Type C1 . 130C.6 Type C3 . 131Annex D (normative)
Requirements and tests for the ducting of C6 appliances . 132D.1 Requirements . 132D.2 Test methods . 132Annex E (informative)
A-deviations . 136E.1 General . 136E.2 Switzerland . 136Annex F (normative)
Special national conditions . 137F.1 General . 137F.2 Belgium. 137F.3 Italy . 137F.4 Poland . 137Annex G (informative)
Identification of gas types in use in various countries . 138Annex H (informative)
National solutions for countries whose national bodies are Affiliate Members of CEN . 139H.1 Categories listed in the body of the standard and marketed in different countries . 139H.2 Appliance supply pressures corresponding to the categories given in H.1 . 139H.3 Special categories marketed nationally or locally . 139H.4 Gases and test pressures corresponding to the special categories given in H.3 . 139Annex I (informative)
Calculation of conversions of NOx . 140Annex J (informative)
An example of sampling plans . 141J.1 Sampling plans . 141J.2 Inspection levels and procedures . 142Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 90/396/EEC . 143Annex ZB (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 145ZB.1 Scope and relevant characteristics . 145ZB.2 Procedure(s) for attestation of conformity of [construction products] . 147ZB.3
CE marking and labelling. 150Bibliography . 152 SIST EN 1319:2010
EN 1319:2009 (E) 4 Foreword This document (EN 1319:2009) has been prepared by Technical Committee CEN/TC 180 “Domestic and non-domestic gas-fired air heaters and non-domestic gas-fired overhead radiant heaters”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2010, and conflicting national standards shall be withdrawn at the latest by June 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1319:1998. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EC Directive(s). For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this document. This revision modifies EN 1319:1998. It has been prepared to incorporate requirements for combustion products evacuation ducts, POCEDs, supplied as an integral part of the system to support the EU Directive 89/106/EEC on construction products under mandate M105. To this end it extends the scope of the standard to cover type B4
and B5
appliances.
Furthermore, the opportunity presented by this revision has been taken to update the standard in respect to EN 437:2003. NOTE For countries requesting special categories (specified in EN 437), the absence of specific information concerning A.4.3 and A.4.4 implies that the general requirements described in the body of the standard (see 5.1.1, 5.2.2, 5.2.3 and 5.2.5) also apply to these special categories. Other European Standards covering gas-fired air heaters are: EN 525, Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW EN 621, Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products EN 778, Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products EN 1020, Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products EN 1196, Domestic and non-domestic gas-fired air heaters
Supplementary requirements for condensing air heaters EN 12669, Direct gas-fired hot air blowers for use in greenhouses and supplementary non-domestic space heating SIST EN 1319:2010
EN 1319:2009 (E) 5 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 1319:2010
EN 1319:2009 (E) 6 1 Scope This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with a fan to assist the transportation of combustion air and/or combustion products, hereafter referred to as appliances. This European Standard applies to Type B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with an input not exceeding 70 kW (net cv basis), intended primarily for use in single unit residential dwellings.
Provision of the heated air may be by means of ducting. This standard does not apply to: a) appliances of the condensing type; b) appliances for outdoor installation; c) dual purpose air conditioning appliances (heating and cooling); d) appliances where the air is heated by an intermediate fluid; e) appliances with forced draught package burners or fully premixed burners; f) appliances fitted with a manual means of adjusting the combustion air supply or the evacuation of the combustion products; g) portable or transportable forced convection appliances; h) appliances having multiple heating units with a single draught diverter; i) appliances fitted with more than one flue outlet; j) Type C22, C23, C42, C43, C52 and C53 appliances; k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 88-1:2007, Pressure regulators and associated safety devices for gas appliances — Part 1: Pressure regulators for inlet pressures up to and including 500 mbar
EN 125:1991, Flame supervision devices for gas burning appliances — Thermo-electric flame supervision devices
EN 126:2004, Multifunctional controls for gas burning appliances SIST EN 1319:2010
EN 1319:2009 (E) 7 EN 161:2007, Automatic shut-off valves for gas burners and gas appliances EN 257:1992, Mechanical thermostats for gas-burning appliances EN 298:2003, Automatic gas burner control systems for gas burners and gas burning appliances with or without fans EN 437:2003, Test gases — Test pressures — Appliance categories EN 1859:2000, Chimneys— Metal chimneys — Test methods EN 10226-1:2004, Pipe threads where pressure tight joints are made on the threads — Part 1: Taper external threads and parallel internal threads — Dimensions, tolerances and designation EN 10226-2:2005, Pipe threads where pressure tight joints are made on the threads — Part 2: Taper external threads and taper internal threads — Dimensions, tolerances and designation EN 12067-1:1998, Gas/air ratio controls for gas burners and gas burning appliances — Part 1: Pneumatic types EN 60335-1:2002, Household and similar electrical appliances — Safety — Part 1: General requirements (IEC 60335-1:2001, modified) EN 60335-2-102:2006, Household and similar electrical appliances — Safety — Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections (IEC 60335-2-102:2004, modified) EN 60529:1991, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989) EN 60584-1:1995, Thermocouples — Part 1: Reference tables (IEC 60584-1:1995) EN 60584-2:1993, Thermocouples; part 2: Tolerances (IEC 60584-2:1982 + A1:1989) EN 60730-2-1:1997, Automatic electrical controls for household and similar use — Part 2: Particular requirements for electrical controls for electrical household appliances (IEC 60730-2-1:1989, modified) EN 60730-2-9:2002, Automatic electrical controls for household and similar use — Part 2-9: Particular requirements for temperature sensing controls (IEC 60730-2-9:2000, modified) EN ISO 228-1:2003, Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) EN ISO 1182:2002, Reaction to fire tests for building products — Non-combustibility test (ISO 1182:2002) ISO 7005-1:1992, Metallic flanges — Part 1: Steel flanges ISO 7005-2:1988, Metallic flanges — Part 2: Cast iron flanges ISO 7005-3:1988, Metallic flanges — Part 3: Copper alloy and composite flanges CR 1404, Determination of emissions from appliances burning gaseous fuels during type testing SIST EN 1319:2010
EN 1319:2009 (E) 8 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 Appliance and its constituent parts 3.1.1 domestic air heater appliance designed for the heating by means of warm air and possibly ventilation of a single unit residential dwelling 3.1.2 forced convection air heater appliance designed to provide space heating from a central source by distributing heated air, by means of an air moving device, either through ducting or directly into the heated space 3.1.3 gas inlet connection part of the appliance intended to be connected to the gas supply 3.1.4 mechanical joint mechanical means of obtaining soundness means of ensuring the soundness of an assembly of several (generally metallic) parts without the use of liquids (e.g. pastes and tapes) EXAMPLES Metal to metal joints; conical joints; toroidal sealing rings (“O” rings); flat joints. 3.1.5
gas circuit part of the appliance that conveys or contains the gas between the appliance gas inlet connection and the burner(s) 3.1.6 restrictor device with an orifice, which is placed in the gas circuit so as to create a pressure drop and thus reduce the gas pressure at the burner to a predetermined value for a given supply pressure and rate 3.1.7
gas rate adjuster component allowing an authorized person to set the gas rate of the burner to a predetermined value according to the supply conditions NOTE 1 Adjustment may be progressive (screw adjuster) or in discrete steps (by changing restrictors). NOTE 2 The adjusting screw of an adjustable regulator is regarded as a gas rate adjuster. NOTE 3 The action of adjusting this device is called "adjusting the gas rate". NOTE 4 A factory sealed gas rate adjuster is considered to be non-existent. SIST EN 1319:2010
EN 1319:2009 (E) 9 3.1.8 setting an adjuster immobilizing of an adjuster (by some means such as e.g. a screw) after the manufacturer or installer has adjusted it setting an adjuster
3.1.9 sealing an adjuster setting of an adjuster using a material such that any attempt to change the adjustment breaks the sealing material and makes the interference with the adjuster apparent NOTE 1 The adjuster is then said to be "sealed" in its adjustment position. NOTE 2 A factory sealed adjuster is considered to be non-existent. NOTE 3 A regulator is considered to be non-existent if it has been factory sealed in a position such that it is not operational in the range of supply pressures corresponding to the appliance category. 3.1.10 putting an adjuster or a control out of service putting an adjuster or a control (e.g of temperature, pressure) out of action and sealing it in this position NOTE The appliance then functions as if the adjuster or control had been removed. 3.1.11 injector component that admits the gas into a burner 3.1.12 main burner burner that is intended to assure the thermal function of the appliance 3.1.13 ignition device any means (e.g flame, electrical ignition device or other device) used to ignite the gas at the ignition burner or at the main burner NOTE This device can operate intermittently or permanently. 3.1.14 ignition burner burner whose flame is intended to ignite another burner 3.1.15 permanent ignition burner ignition burner that operates continuously throughout the whole period that the appliance is in use 3.1.16 intermittent ignition burner ignition burner that is ignited before and extinguished at the same time as the main burner 3.1.17 alternating ignition burner ignition burner that is extinguished as soon as ignition of the main burner is effected, and that re-ignites at the main burner flame just before the latter goes out 3.1.18 interrupted ignition burner ignition burner that operates only during the ignition sequence SIST EN 1319:2010
EN 1319:2009 (E) 10 3.1.19 aeration adjuster device enabling the air to be set at the desired value according to the supply conditions NOTE The action of adjusting this device is called "adjusting the aeration". 3.1.20 combustion products circuit 3.1.20.1 combustion chamber enclosure inside which combustion of the air-gas mixture takes place 3.1.20.2 flue outlet part of a Type B appliance that connects with a flue to evacuate the products of combustion 3.1.20.3 draught diverter device placed in the combustion products circuit to reduce the influence of flue-pull and that of down-draught on the burner performance and combustion 3.1.20.4 flue damper manual or automatic device placed in the combustion products circuit intended to restrict or fully close off the passageways for the evacuation of products of combustion when the appliance is not in use 3.1.20.5 flue terminal device fitted at the end of the duct system which enables the discharge of flue gases and may, at the same time, allow entry of combustion air 3.1.20.6 C6 flue terminal terminal which is specially approved for Type C6 appliances 3.1.20.7 flue adaptor box means of adapting the appliance for connection to different duct systems (e.g. from concentric to separate ducts) 3.1.20.8 POCED combustion products evacuation duct that is intended to be used only with a specific appliance/system, this duct being either supplied with the appliance/system or specified in the manufacturers instructions 3.1.21 fully premixed burner pre-aerated burner system in which gas is mixed in a pre-determined and adjustable ratio with all of the air necessary for combustion 3.1.22 gas/air ratio control device that automatically adapts the combustion air rate to the gas rate and vice versa SIST EN 1319:2010
EN 1319:2009 (E) 11 3.2 Adjustment, control and safety devices 3.2.1 range rating device component on the appliance intended to be used by the installer to adjust the heat input of the appliance, within a range of heat inputs stated by the manufacturer, to suit the actual heat requirements of the installation NOTE This adjustm
...
Questions, Comments and Discussion