1.1   Scope of EN 12309
Appliances covered by this document include one or a combination of the following:
-   gas-fired sorption chiller;
-   gas-fired sorption chiller/heater;
-   gas-fired sorption heat pump.
This document applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This document applies to appliances having flue gas systems of Type B and Type C (according to EN 1749:2020) and to appliances designed for outdoor installations, including Type A. EN 12309 does not apply to air conditioners, it only applies to appliances having:
-   integral burners under the control of fully automatic burner control systems,
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,
-   mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in EN 12309-1:2023).
In the case of packaged units (consisting of several parts), this document applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.
All the symbols given in this document are used regardless of the language used.
1.2   Scope of this Part 6 to EN 12309
This part of EN 12309 specifies the calculation methods of seasonal performances for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW. It deals in particular with the calculation methods of reference seasonal performances in cooling and heating mode for monovalent and bivalent appliances.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage appliances; water-heaters and combination boilers that have:
-   heat input not exceeding 70 kW; and
-   hot water storage capacity (if any) not exceeding 500 l.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
This document sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 is applicable with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for multifunctional controls for burners and appliances burning one or more gaseous fuels, hereafter referred to as ‘MFC’. This document is applicable to MFCs with declared maximum inlet pressures up to and including 50 kPa and nominal connection sizes up to and including DN 150.
Addition:
This document is applicable to MFCs consisting of two or more functions, at least one of which is a mechanical control, as specified in the relevant control standard (see Figure 1).
This document does not apply to MFCs consisting only of electronics (an example is a combination of functions according to EN 298:2022 and EN 1643:2022).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for automatic shut-off valves for burners and appliances burning one or more gaseous fuels, hereafter referred to as “valves”.
This document is applicable to valves with declared maximum inlet pressures up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
-   electrically actuated valves;
-   valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to any external electrical devices for switching the control signal or actuating energy;
-   valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal;
-   valves fitted with closed position indicator switches.
An assessment method for valve designs is given by this document.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the essential terms, constructional requirements, tests, energy assessment and marking of indirectly heated water storage tanks for primary water (buffer tanks), with a capacity not exceeding 2,000 l, an operating temperature not exceeding 95 °C, and an operating pressure not exceeding 1,0 MPa (10 bar).
This document covers metallic and plastic made buffer tanks.
Although this document does not consider any buffer tanks mainly intended for direct firing, it allows for the provision of electric heating elements for auxiliary purposes.
NOTE   The energy assessment is performed by EN 15332 or EN 12897.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as “boilers”.
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1   For further background information on appliance types see EN 1749:2020.
a)   that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b)   that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c)   where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the water circuit does not exceed 6 bar;
e)   which are declared in the technical instructions to be either a “low temperature boiler” or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”;
f)   which are intended to be installed inside a building or in a partially protected place;
g)   which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h)   which are designed for either sealed water systems or for open water systems.
NOTE 2   This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa)   appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB);
ab)   appliances using flue dampers;
ac)   appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ad)   appliances of the types A, B14, B¬2, B3, B4, B5 and C;
ae)   appliances intended to be connected to a (common) flue having mechanical extraction;
af)   appliances with gas/air ratio control;
ag)   modular boilers;
ah)   boilers which can give rise to condensation under certain circumstances;
ai)   boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system;
aj)   surface temperatures of external parts particular to children and elderly people;
ak)   appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al)   boilers intended to be installed in areas accessible to elderly people and children;
am)   boilers equipped with an adaptive combustion control function (ACCF).
NOTE   Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of EN 16905 series
This series specifies the requirements, test methods and test conditions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor.
This series is used in conjunction with:
a)   the terms and definitions, EN 16905 1:2023;
b)   the safety, EN 16905 2:—1;
c)   the requirements, test conditions and test methods, EN 16905 4:—2;
d)   the calculation of seasonal performances in heating and cooling mode, EN 16905‐5:2022;
e)   the heat pump standards, EN 14511‐2:2022, EN 14511 3:2022 and EN 14825:2022.
This series only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This series only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This series only applies to appliances having:
a)   gas-fired endothermic engines under the control of fully automatic control systems;
b)   closed-system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the
1)   heating water circuit (if installed) does not exceed 6 bar;
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This series applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This series is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
1.2   Scope of EN 16905 3
This part of the EN 16905 series specifies the test conditions for the rating of energy parameters of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of EN 12309 series
Appliances covered by this document include one or a combination of the following:
-   gas-fired sorption chiller;
-   gas-fired sorption chiller/heater;
-   gas-fired sorption heat pump;
-   hybrids based on gas sorption appliances.
This document applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This document applies to appliances having flue gas systems of Type B and Type C (according to EN 1749:2020) and to appliances designed for outdoor installations, including Type A.
EN 12309 does not apply to air conditioners, it only applies to appliances having:
-   integral burners under the control of fully automatic burner control systems;
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated;
-   mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in EN 12309-1:2023).
In the case of packaged units (consisting of several parts), this document applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309. All the symbols given in this text are to be used regardless of the language used.
1.2   Scope of this Part 3 of EN 12309
This part of EN 12309 specifies the requirements, test methods and conditions for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW.
This part of EN 12309 deals particularly with test protocols and tools to calculate the capacity, the gas utilization efficiency and the electrical power input of the appliance. This data can be used in particular to calculate the seasonal efficiency of the appliance.

  • Standard
    75 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW (based on the net calorific value), thereafter referred to as appliances.
This document is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner, that uses one or more combustible gases of the three gas families at the pressures stated in EN 437:2021. The appliances are for decorative purposes only and are not heating appliances.
This document is applicable to type BAS, as described in 4.2, decorative fuel effect gas appliances that are designed to be installed within a non-combustible builder's opening or a non-combustible fireplace recess.
NOTE 1   This document specifies special national conditions in Annex C for appliances of category I2E+, marketed in Belgium.
NOTE 2   This document specifies special A-deviations in Annex D for appliances in Switzerland which require additional requirements for subclauses 6.6 and 6.7.
This document includes additional requirements for Type BBS appliances which are specified in Annex F.
In addition, this document is applicable to decorative fuel-effect gas appliances that are designed to be installed under a non-combustible canopy which is independent or integral with a flue box, for which additional requirements are specified in Annex A.
The use of toxic gases is not covered.
This document is not applicable to:
-   catalytic combustion appliances;
-   appliances in which the supply of combustion air and/or the evacuation of products of combustion is achieved by mechanical means.
NOTE 3   Requirements concerning the rational use of energy have not been included in this document, because the appliances are for decorative purposes.

  • Standard
    75 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test method for the rational use of energy of gas cooking appliances having forced-convection ovens and/or grills using combustible gases described in Clause 1 of EN 30 1 2:2012.
This document covers only type testing.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and the methods of test for the rational use of energy of gas burning domestic cooking appliances, in accordance with EN 30-1-1:2021+A1:2023, Clause 1.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
automatic vent valves for burners and appliances burning one or more gaseous fuels, hereafter referred
to as “valves”.
This document is applicable to valves with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 100.
Addition:
This document is applicable to:
— electrically actuated valves;
— valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to
any external electrical devices for switching the control signal or actuating energy;
— valves fitted with open position indicator switches.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
thermoelectric flame supervision devices, energized by a thermocouple intended for use with burners
and appliances burning one or more gaseous fuels, hereafter referred to as “controls”.
This document is applicable to controls with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 50.
Addition:
This document is not applicable to:
— the thermocouple;
— controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
pneumatic pressure regulators and safety devices for burners and appliances burning one or more
gaseous fuels, hereafter referred to as “pressure regulators”.
This document is applicable to pressure regulators with declared maximum inlet pressures above 50 kPa
up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— pressure regulators incorporating safety devices;
— pressure regulators and safety devices which use auxiliary energy;
— stand-alone pressure regulators or pressure regulators equipped with a control device for maximum
or minimum gas pressure.
This document is not applicable to:
— pressure regulators connected directly to a gas distribution network or to a container that maintains
a standard distribution pressure;
— pressure regulators intended for gas appliances to be installed in the open air and exposed to the
environment.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
electronic pressure and/or flow rate regulators for burners and appliances burning one or more gaseous
fuels, hereafter referred to as “regulators”.
This document is applicable to regulators with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— regulators which use auxiliary energy;
— regulators, which function by controlling a gas outlet pressure or a gas flow rate;
— regulators with a modular structure specified as a unit;
— regulators intended for gas appliances to be installed indoor or in the open air and exposed to the
environment.
This document is not applicable to:
— regulators connected directly to a gas distribution network or to a container that maintains a
standard distribution pressure.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Scope of CEN/TS 15502-3-1
EN 15502-2-1:2022, Clause 1 applies with the following modifications:
Add after k):
l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20).
m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance.
Replace ab) and ak) and al) by the following:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality.
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document);
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).

  • Technical specification
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance on hydrogen specific safety, design, construction, and performance requirements and testing of safety, control or regulating devices (hereafter referred to as controls) for burners and appliances burning gases with hydrogen content.
The following hydrogen concentrations are covered in this document:
- H2NG (hydrogen in natural gas) blends of 20 % hydrogen; or
- 100 % hydrogen; or
- varying blends / admixtures to natural gas.
Furthermore, it identifies the expected revision needs of the existing CEN/TC 58 standards as well as the need of potential further new standardization deliverables.

  • Technical report
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1   For further background information on appliance types see EN 1749:2020.
a)   that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b)   that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c)   where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the water circuit does not exceed 6 bar;
e)   which can give rise to condensation under certain circumstances;
f)   which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g)   which are intended to be installed inside a building or in a partially protected place;
h)   which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i)   which are designed for either sealed water systems or for open water systems;
j)   which are either modular boilers, or non-modular boilers.
k)   which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2   This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa)   appliances above 1 000 kW;
ab)   appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac)   appliances using flue dampers;
ad)   appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae)   C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af)   appliances incorporating flexible plastic flue liners;
ag)   C(10) boilers:
1)   without a gas-air ratio control, or
2)   which are non-condensing appliances, or
3)   which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah)   C(11) boilers that have boiler modules:
1)   without a gas-air ratio control, or
2)   which are non-condensing appliances, or
3)   which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai)   appliances intended to be connected to a flue having mechanical extraction;
aj)   surface temperatures of external parts particular to children and elderly people;
ak)   appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al)   appliances equipped with an adaptive combustion control function (ACCF);
am)   boilers intended to be installed in areas accessible to elderly people and children.

  • Standard
    105 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.

  • Standard
    213 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
mechanical thermostats intended for use with gas appliances and similar use, hereafter referred to as
“thermostats”.
This document is applicable to thermostats with declared maximum inlet pressures up to and including
50 kPa and of nominal connection sizes up to and including DN 50 for use with one or more fuel gases.
Addition:
This document is applicable to thermostats controlling the gas flow directly or indirectly through an
integral gas valve. This document applies to thermostats used with gas appliances which are not installed
in the open air.
Thermostats dealt with in this document are intended for control functions.
This document is not applicable to:
a) controls which use auxiliary energy (e.g. electrical energy supplied externally);
b) an assessment of the control regarding Performance Level (PL) and Safety Integrity Level (SIL).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
pressure regulators and pneumatic gas/air ratio pressure regulators (zero pressure regulators are
included as a special type of pneumatic gas/air ratio pressure regulators) for burners and appliances
burning one or more gaseous fuels, hereafter referred to as “pressure regulators”.
This document is applicable to pressure regulators with declared maximum inlet pressures up to and
including 50 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— pressure regulators which use auxiliary energy;
— pneumatic gas/air ratio pressure regulators, which function by controlling a gas outlet pressure in
response to an air signal pressure, air signal differential pressure, and/or to a furnace pressure signal
(zero pressure regulators are included as a special type of pneumatic gas/air ratio pressure
regulators);
— pneumatic gas/air ratio pressure regulators, which change an air outlet pressure in response to a gas
signal pressure or a gas signal differential pressure.
This document is not applicable to:
— pressure regulators connected directly to a gas distribution network or to a container that maintains
a standard distribution pressure;
— pressure regulators intended for gas appliances to be installed in the open air and exposed to the
environment;
— mechanically linked gas/air ratio controls;
— electronic gas/air ratio controls (EN 12067-2:2022).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for gas filters for burners and appliances burning one or more gaseous fuels.
This document is applicable to gas filters with declared maximum inlet pressures up to and including 600 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is not applicable to:
-   gas filters that are connected directly to mains pipe-work or to a container that maintains a standard distribution pressure.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the measurements of the emissions of carbon monoxide (CO) and nitrogen oxides (NOX) produced by the combustion of gaseous fuel in domestic appliances. It is also possible to adapt it to liquid fuel appliances.
It explains how to correct the measured values obtained at the testing conditions of temperature, humidity and gas used into the reference conditions, as well as their conversion to different aeration factor expressed as %O2 in the dry products of combustion.
The document also contains information on the types of sampling probes, mainly their form and their dimensions, which depend on the type of flue gas system.
It also gives detailed information on the sampling of the flue gas to be analysed, the transport / transfer lines and their components, and the materials recommended for their construction.
This document contains hints on the calculation of the uncertainties and the parameters to be considered in the whole analysis chain from the sampling probe to the analysers including the calibration gases.
The calculation of the uncertainties of the measurements of NOX and CO is not covered by this document.

  • Technical report
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the specifications and test methods concerning the construction, safety, rational use of energy and fitness for purpose, and also the classification and marking of gas-fired instantaneous water heaters for sanitary uses, hereafter called “water heaters”.
This European Standard applies to water heaters:
-   of types AAS, B11, B11BS, B12, B12BS, B13, B13BS, B14, B22, B23, B32, B33, B44, B52, B53, C11, C12, C13, C21, C22, C23, C32, C33, C42, C43, C52, C53, C62, C63, C72, C73, C82and C83 according to CEN/TR 1749;
-   fitted with atmospheric burners;
-   equipped with atmospheric burners assisted by a fan for the supply of combustion air or evacuation of combustion products or fully premix burners;
-   using one or more combustible gases corresponding to the three gas families and at the pressures stated in accordance to EN 437;
-   of nominal heat input not exceeding 70 kW;
-   with an ignition burner or with direct ignition of the main burner.
In this European Standard, the heat inputs are expressed in relation to the net calorific value (Hi).
This European Standard does not contain all the requirements necessary for:
-   boiling water appliances;
-   appliances intended to be connected to a mechanical means of evacuating the combustion products;
-   appliances which fulfil a dual role of space heating and heating water for sanitary use;
-   appliances making use of the heat of condensation of the water contained in the combustion products;
-   water heaters of types B21, B31, B41, B42, B43 and B51.
This European Standard only covers water heaters where the fan, if any, is an integral part of the appliance.
This European Standard:
-   does not apply to appliances not intended to be connected to a flue when they are not fitted with an atmosphere sensing device;
-   takes account of the information given in Technical Report CEN/CR 1472:1994 with respect to marking.
Type B appliances should be with a combustion products discharge safety device to comply with essential requirement 3.4.3 of the Gas Appliances Directive 2009/142/EC. In this European Standard, the appliance is identified as type B11BS.
Appliances intended to be installed outdoors or in a room separate from inhabited rooms and provided with appropriate ventilation are not required to have this combustion products discharge safety device but, in this case, appropriate warnings on the packaging, and in the instructions should clearly define the limited authorized use for this type of appliance. In this European Standard, the appliance is identified as type B11.
The main symbols used in this European Standard are summarized in Annex F.

  • Standard
    168 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of EN 203-1:2021 applies, with the following addition and modification of the 3rd paragraph:
This document applies to catering, bakery and pizza ovens.
This document applies to gas heated natural and forced convection ovens, multi-function ovens and
atmospheric steaming ovens.
This document does not cover appliances which are specifically designed for use in industrial processes
on industrial premises nor appliances intended to be operated with the door open.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special constructional and operational characteristics, as well as the requirements and methods of test for safety and marking, for domestic cooking appliances having forced-convection ovens and /or grills using combustible gases, as defined in EN 30-1-1:2008+A2:2010.
Unless specifically excluded, this European Standard applies to appliances or their component parts, whether the component parts are independent or incorporated as part of the appliance, even if the other heating components use electrical energy (for example combined gas-electric cookers).
This European Standard includes requirements covering the electrical safety of equipment incorporated in the appliance that are associated with the use of gas. It does not include requirements covering the electric safety of electrically-heated components or their associated equipment1).
This European Standard does not apply to:
- outdoor appliances;
- appliances connected to a combustion products evacuation duct;
- appliances having a pyrolytic gas oven;
- appliances having covered burners which do not comply with the constructional requirements
of EN 30-1-1:2008+A2:2010, 5.2.8.2.2;
- appliances incorporating flame supervision devices and having an automatic ignition device for which the duration of the ignition attempt is limited by design;
- appliances equipped with a burner that is periodically ignited and extinguished under the control of an automatic on/off device;
- appliances equipped with a burner having a fan for the supply of combustion air or for the evacuation of the products of combustion;
- appliances supplied at pressures greater than those defined in EN 30-1-1:2008+A2:2010, 7.1.2;
- appliances equipped with an oven and/or with a grill having a fan either for the supply of combustion air or for the evacuation of the products of combustion;
- appliances equipped with a compartment in which a burner and an electric heating element can function simultaneously;
- appliances having one or more burners that are capable of remote operation (type 1 or type 2), unless the burner(s) concerned are thermostatically controlled oven burners of time-controlled ovens that are designed for a delayed start without the user being present.
This European Standard does not cover the requirements relating to third family gas cylinders, their regulators and their connection.
This European Standard only covers type testing.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for manually operated taps and presetting taps for burners and appliances burning one or more gaseous fuels, hereafter referred to as "taps".
This document is applicable to taps with declared maximum inlet pressures up to and including 50 kPa and of nominal connection sizes up to and including DN 50 for use with one or more fuel gases.
Addition:
This document is not applicable to:
a)   manual operated shut-off valves conforming to EN 331:2015;
b)   controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and methods of test for the safety and marking of freestanding
and built-in domestic cooking appliances burning combustible gases given in EN 437:2021, referred to in
the text as “appliances”.
The appliances covered by this document are intended to be used in a domestic dwelling.
This document covers the following types of domestic cooking appliances:
— independent freestanding hobs;
— independent built-in hobs;
— hobs and grills;
— table cookers;
— freestanding ovens;
— built-in ovens;
— freestanding or built-in grills;
— griddles;
— freestanding cookers;
— built-in cookers.
This document also applies to gas cooking appliances incorporating electrical heating elements (e.g. gaselectric
cooking appliances).
For appliances intended to be used in caravans, or motorhomes/mobile homes or on board of ships or
aircraft, additional requirements may be necessary.
This document does not apply to:
a) outdoor appliances;
b) appliances connected to a combustion products evacuation duct;
c) appliances having a pyrolytic gas oven;
d) appliances incorporating flame supervision devices and having an automatic ignition device for
which the duration of the ignition attempt is limited by design;
e) appliances equipped with a burner that is periodically ignited and extinguished under the control of
an automatic on/off device;
f) appliances equipped with an oven and/or with a grill having a fan:
1) either for the supply of combustion air or for the evacuation of the products of combustion;
2) or for the circulation of the products of combustion within the compartments;
g) appliances incorporating one or more hob or grill burners that enable the user to program the
delayed start of the cooking cycle;
h) appliances of categories I2N, I2R, I3R, I2E(S), I2E(R), I2Esi, I2Er, I2R and the equivalent double and
triple categories which include these indices;
i) appliances of category II2E+3B.
This document does not cover the requirements relating to third family gas cylinders, their pressure
regulators and their connection.

  • Standard
    127 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of EN 203-1:2021 applies, with the following modifications:
- replace the 2nd paragraph with the following:
This document applies to open burners, non-enclosed covered burners and wok burners appliances.
- replace the 3rd paragraph with the following :
This document does not cover appliances of type B.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods for the construction and operating
characteristics relating to safety and rational use of energy for gas heated commercial catering and
bakery appliances intended to be used indoor.
This document applies to all professional cooking and bakery appliances using gas for preparing food and
drink.
Only appliances of types A1, A2, A3, B1 and B2, as defined in Clause 4, are considered in this document.
Only the net calorific value (Hi) and net Wobbe index (Wi) are used.
The requirements concerning specific types of appliances are given in the relevant Part 2.
Annex C (informative) lists the main types of equipment covered by the scope of this document.
Appliances covered by this document are not intended to use gases containing carbon monoxide or other
toxic components.
NOTE For appliances intended to be used in vehicles, in trailers or on-board ships, additional requirements
can be necessary.

  • Standard
    85 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The scope of EN 203-1:2021 applies, with the following addition and modification of the 3rd paragraph.
This document applies to catering fryers.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing of pressure sensing devices for burners and appliances burning one or more gaseous fuels.
This document is applicable to pressure sensing devices for gaseous fuels, air, or combustion products with declared maximum inlet pressures up to and including 500 kPa.
It applies to all types of pressure sensing devices, including electronic, differential and inferential types.
It also specifies requirements for pressure sensing devices which are intended to be applied to steam boilers and as such need to meet increased reliability requirements.
EN 13611:2019 Clause 1, 4th paragraph is not applicable.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies requirements and methods of test for lubricants to be used in gas appliances of all categories including auxilliary equipment mounted or intended to be mounted on such appliances and which may be in contact with combustible gases, except those designed for use in industrial processes.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and tests methods concerning the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid units.
A hybrid unit is composed of:
-   a gas boiler as a heat generator which is able to supply the heat demand in all operating conditions;
-   an electrical air-to-water heat pump, as a heat generator, which does not have to meet the heat demand in all operating conditions;
-   a control unit (see definition 3.1.10).
A hybrid unit can include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit.
A gas boiler as part of a hybrid unit covered by this document is a gas-fired central heating boiler from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020:
a)   that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW;
b)   that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c)   where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the water circuit does not exceed 6 bar;
e)   which are classified as a gas-fired central heating boiler;
f)   which are intended to be installed either indoors or outdoors in a partially protected place;
g)   which are designed for either sealed water systems or for open water systems.
This document provides requirements for boilers with known constructions.
NOTE 1   For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
NOTE 2   An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11.
This document does not cover all the requirements for:
aa)   appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see EN 15502-1:2021, Annex AB);
ab)   appliances using flue dampers;
ac)   appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81;
ad)   appliances incorporating flexible plastic flue liners;
ae)   appliances designed to become connected to a combined flue duct system.
af)   appliances of the types C(10),C(11), C(12) and C(13);
ag)   C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ah)   appliances intended to be connected to a flue having mechanical extraction;
ai)   surface temperatures of external parts particular to children and elderly people;
aj)   appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
ak)   appliances equipped with an adaptive combustion control function (ACCF);
al)   boilers intended to be installed in areas accessible to elderly people and children.
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the technical instructions when used for space heating and/or DHW production.
This document is intended to be used in conjunction with:
ba)   the gas-fired boiler, the generic part EN 15502-1:2021 and specific parts FprEN 15502-2-1:2022 and FprEN 15502-2-2:2022;
bb)   the electrical heat pump, EN 14511-4:2018, EN 378-1:2016+A1:2020, EN 378-2:2016 and EN 14825:2022;
bc)   electrical safety, EN 60335-1:2012 , EN 60335-2-102:2016 and IEC 60335-2-40:2018;
bd)   for domestic hot water production, EN 13203-5:2022.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of the EN 16905 series
This part of EN 16905 specifies the terms and definitions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor.
This European Standard specifies the terms and definitions.
This European Standard is to be used in conjunction with the following standards:
a)   FprEN 16905-2:2022 on safety;
b)   EN 16905-3:2017 on test conditions;
c)   prEN 16905-4:2022 on the requirements, test conditions and test methods;
d)   FprEN 16905‐5:2022 on the calculation of seasonal performances in heating and cooling mode;
e)   the heat pump standards, EN 14511‐2, EN 14511-3 and EN 14825.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
f)   gas fired endothermic engines under the control of fully automatic control systems;
g)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
h)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
i)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This European Standard is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of EN 12309
Appliances covered by this document include one or a combination of the following:
-   gas-fired sorption chiller;
-   gas-fired sorption chiller/heater;
-   gas-fired sorption heat pump;
-   hybrids based on gas sorption appliances.
This document applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This document applies to appliances having flue gas systems of type B and C (according to EN 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:
-   integral burners under the control of fully automatic burner control systems,
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,
-   mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery).
In the case of packaged units (consisting of several parts), this standard applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.
All the symbols given in this text are used regardless of the language used.
1.2   Scope of this Part 1 of EN 12309
This part of this document specifies the terms and definitions for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors.
This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This document only applies to appliances having:
a)   gas fired endothermic engines under the control of fully automatic control systems;
b)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar,
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 is replaced by following:
This document specifies the safety, design, construction and performance requirements, and testing for valve-proving systems, hereafter referred to as “VPS”, intended for use with gas burners and gas-burning appliances burning one or more gaseous fuels.
This document applies to all types of VPS used for the automatic detection of leakage in a gas burner section having at least two automatic shut-off valves, and which give a signal if the leakage of one of the valves, the piping in-between the valves or of the VPS itself and its components exceeds the detection limit.
This document applies to VPS for gases with a maximum inlet pressure up to and including 500 kPa.
This document does not apply to VPSs for use in explosive atmospheres.
This document is applicable to AC and DC supplied VPS (for VPS supplied by stand-alone battery system, battery systems for mobile applications, or VPS which are intended to be connected to DC supply networks, see Annex I).

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 is replaced by the following:
This document specifies the safety, design, construction and performance requirements, and testing for electronic fuel/air ratio control systems (ERC), electronic fuel/air ratio supervision systems (ERS) and electronic fuel/air ratio trim systems (ERT) intended for use with burners and appliances burning gaseous or liquid fuels. It also describes the procedures for evaluating these requirements and specifies information necessary for installation and use.
This document is applicable to:
-   closed loop fuel/air ratio control systems, see 3.101;
-   fuel/air ratio supervision systems, see 3.102;
-   closed loop fuel/air ratio trim systems, see 3.103;
and does not differentiate into classification by heat input.
NOTE   The documents for burners, appliances or processes which use ERC, ERS or ERT can override the requirements of this document.

  • Standard
    70 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General
This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer.
This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically.
The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber.
The boilers may operate in condensing condition.
NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery
Directive 2006/42/EC.
This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper).
This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard.
Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This European Standard does not apply to:
heating boilers and other heating appliances which are also designed for the direct heating of the place of installation;
cooking appliances;
the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler;
room sealed applications above a nominal heat output > 70 kW or operated with positive pressure in the combustion chamber or operated under natural draught;
This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements.
This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard).
1.2 Fuels
These boilers may burn either fossil fuels, biogenic fuels or other fuels such as peat, as specified for their use by the boiler manufacturer, in accordance with the requirements of this European Standard.
Solid fuels included in this European Standard are categorised as follows.
1.2.1 Biogenic fuels
Biomass in a natural state, in the form of:
Adaptation to new fuels standards and consideration of new fuels standards in preparation.
A log wood with moisture content w ≤ 25 %, according to EN 14961-5;
B1 chipped wood (wood chipped by machine, usually up to a maximum length of 15 cm) with moisture content from w 15 % to w 35 %, according to EN 14961-4;
B2 chipped wood as under B1, except with moisture content w > 35 %;
C1 compressed wood (e.g. pellets without additives, made of wood and/or bark particles; natural binding agents such as molasses, vegetable paraffins and starch are permitted), pellets according to EN 14961-2;
(...)

  • Standard
    103 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 is replaced by the following:
This document specifies the safety, design, construction and performance requirements, and testing for automatic burner control systems, programming units, flame detector devices and High Temperature Operation (HTO) detectors, intended for use with gas and oil burners and gas and oil burning appliances, with or without fans and similar use.
This document is applicable to automatic burner control systems that include additional functions.
This document is not applicable to automatic burner control systems utilizing thermo-electric flame supervision devices.
NOTE    Standards for burners, appliances or processes which use automatic burner control systems, programming units, flame detectors or HTO detectors can override the requirements of this document.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terminology, the general requirements for the construction and operation of forced draught gas burners and also the provision of control and safety devices, and the test procedure for these burners.
This European Standard is applicable to:
-   automatic gas burners with a combustion air fan (hereinafter called "burners") and gas line components, intended for use in appliances of different types, and that are operated with gaseous fuels;
-   pre mixed burners and nozzle mixed burners;
-   single burners with a single combustion chamber;
-   single fuel and dual fuel burners when operating only on gas;
-   the gas function of dual-fuel burners designed to operate simultaneously on gaseous and liquid fuels, which, for the latter, the requirements of EN 267 also apply.
This European Standard deals with all significant machine hazards, hazardous situations and events relevant to burners, when they are used as intended and under conditions of misuse which are reasonably foreseeable, see Annex J.
This European Standard specifies the requirements to ensure the safety during commissioning, start-up, operation, shut-down and maintenance.
This European Standard does not apply to burners specifically designed for use in industrial processes carried out on industrial premises.
This European Standard deals also with the additional requirements for the burners in the scope with pressurised parts and /or firing pressurised bodies, see Annex K.
This European Standard deals also with forced draught burners intended to be used with biogenous gaseous fuels, mixtures with line-conveyed gas and special gaseous fuels.
This European Standard deals also with burners and their equipment to increase the total appliance efficiency, see Annex M.

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the construction characteristics, performances and marking related to safety and the rational use of energy of portable, flat gas appliances directly supplied at the LPG vapour pressure, incorporating a gas cartridge complying with EN 417:2012, inserted horizontally in the chassis.
NOTE 1   These appliances are referred to in the body of the text as “appliances”.
This document covers appliances for outdoor or in well ventilated areas uses only.
This document does not cover appliances supplied by an external gas source.
For example, the following types of appliances are covered:
a)   cooking appliances (stoves, barbecues);
b)   heating appliances.
This document specifies the requirements applicable to these appliances or their functional sections whether or not the latter are independent or incorporated into an assembly.
Appliances covered by this document are not connected to a flue for the discharge of products of combustion and are not connected to the mains electricity supply.
This document covers neither appliances supplied with LPG in the liquid phase nor appliance with fixed integral container which could be refilled by the user.
This document does not cover appliances of direct pressure propane category.
Requirements for rational use of energy have been considered for stove burners.
NOTE 2   However, such requirements have not been considered for the other types of appliances because:
-   for barbecues, this type of cooking varies according to the type of food and region where the appliance is used;
-   for heating appliances, all the heat produced is discharged into the environment.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired appliances producing domestic hot water. It applies to sorption heat pumps connected to or including a domestic hot water storage tank. It applies to a package marketed as single unit or fully specified that have:
-   a heat input not exceeding 400 kW;
-   a hot water storage tank capacity (if any) not exceeding 2 000 l.
In the case of gas-fired sorption heat pumps, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. The present document sets out a method for assessing the energy performance of the appliances. It specifies a number of daily load profiles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user. Where other technologies are combined with a gas-fired sorption heat to produce domestic hot water, specific parts of EN 13203 apply.
Horizontal ground heat sources are not covered by the scope of the present document.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired appliances producing domestic hot water. It applies to condensing combination boilers with passive flue heat recovery device (PFHRD) that have:
-   a heat input not exceeding 400 kW;
-   a hot water storage tank capacity (if any) not exceeding 2 000 l;
-   a declared load profile between M to 4XL.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
For this document, some tests and calculation results of EN 13203-2:2022 are used to calculate the energy consumptions.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired mCHP appliances producing domestic hot water and electricity. The electricity is generated in a process linked to the production of useful heat.
It applies to a mCHP appliances marketed as single unit or as a package fully specified by a manufacturer that have:
-   a gas heat input not exceeding 400 kW;
-   an electrical output not exceeding 50 kW;
-   a hot water storage capacity (if any) not exceeding 2 000 l.
EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a variety of uses. It also gives a system for presenting the information to the user.
The present document sets out a method for assessing the energy performance of gas fired mCHP appliances. It defines several daily tapping cycles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user.
When the mCHP generator does not supply domestic hot water in the summer period, the present standard is not applicable. EN 13203-2:2022 is used for performance assessment of these generators.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage gas-fired combined with electric heat pump.
It applies to a package marketed as single unit or fully specified by the manufacturer that have:
-   a heat input not exceeding 400 kW;
-   a hot water storage tank capacity (if any) not exceeding 2 000 l.
EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. The present document sets out a method for assessing the energy performance of gas fired appliances combined with heat pump with electrically driven compressor according to EN 16147. It specifies a number of daily load profiles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user. Where other technologies are combined with a gas-fired boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.
The present document does not apply for gas boilers with recovery systems using combustion products as heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the present standard is not applicable for energy performances assessing, instead EN 13203-2:2022 is applicable.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage tank appliances; waters-heaters and combination boilers that have:
-   a heat input not exceeding 400 kW;
-   a hot water storage tank capacity (if any) not exceeding 2 000 l.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
The water heaters covered by the present standard are considered "conventional water heaters" as defined by the Transitional Methods (Commission Communication 2014/C 207/03) then in the calculation formula for the Annual Electricity Consumption (AEC), Qcor is equal to zero.
In case of the boiler is equipped with an internal or external Passive Flue Heat Recovery Device (PFHRD), the boiler efficiency can be assessed by applying EN 13203-2:2022 in combination with EN 13203-7:2022. In case of a PFHRD, where the technology has the ability to recover energy out of flue gasses during central heating production to be able to preheat the domestic hot water (indirect contribution), to assess this indirect contribution EN 13203-7:2022 applies. EN 13203-2:2022 is applicable for measuring and calculating the direct efficiency (direct contribution) while combining the measuring results of EN 13203-7:2022 the overall efficiency (direct and indirect) can be calculated. EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. The present document sets out a method for assessing the energy performance of the appliances. It specifies a few daily load profiles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user. Where other technologies are combined with a gas-fired boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for automatic shut-off valves for burners and appliances burning one or more gaseous fuels, hereafter referred to as “valves”.
This document is applicable to valves with declared maximum inlet pressures of more than 500 kPa and up to and including 6 300 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
-   electrically actuated valves;
-   valves actuated by fluids including the pilot valves for these fluids if actuated electrically and including release valves, but not to any external electrical devices for switching the actuating energy;
-   valves where the flow rate is controlled by external electrical signals proportional to the applied signal;
-   valves fitted with closed position indicator switches.
This document is not applicable to valves specifically designed for use in transmission and distribution networks.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.