Aerospace series - Cable, electrical, aircraft use - Test methods - Part 407: Flammability

This standard specifies two methods of determining the flammability characteristics of a finished cable.
It shall be used together with EN 3475-100.

Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 407: Entflammbarkeit

Diese Norm legt die Anforderungen an
Aluminiumlegierung AL-R39002
Schmiedevormaterial
für Anwendungen in der Luft- und Raumfahrt fest.

Série aérospatiale - Câbles électriques a usage aéronautique - Méthodes d'essais - Partie 407 : Tenue a la flamme

Aeronavtika – Električni kabli za uporabo v zračnih plovilih – Preskusne metode – 407. del: Gorljivost

General Information

Status
Withdrawn
Publication Date
30-Jun-2006
Withdrawal Date
23-Aug-2009
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
24-Aug-2009
Due Date
16-Sep-2009
Completion Date
24-Aug-2009

Relations

Buy Standard

Standard
EN 3475-407:2006
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 3475-407:2006
01-julij-2006
$HURQDYWLND±(OHNWULþQLNDEOL]DXSRUDERY]UDþQLKSORYLOLK±3UHVNXVQHPHWRGH±
GHO*RUOMLYRVW
Aerospace series - Cable, electrical, aircraft use - Test methods - Part 407: Flammability
Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren -
Teil 407: Entflammbarkeit
Série aérospatiale - Câbles électriques a usage aéronautique - Méthodes d'essais -
Partie 407 : Tenue a la flamme
Ta slovenski standard je istoveten z: EN 3475-407:2005
ICS:
13.220.40
49.060
SIST EN 3475-407:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 3475-407
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2005
ICS 13.220.40; 49.060 Supersedes EN 3475-407:2002
English Version
Aerospace series - Cable, electrical, aircraft use - Test methods
- Part 407: Flammability
Série aérospatiale - Câbles électriques à usage Luft- und Raumfahrt - Elektrischen Leitungen für Luftfahrt
aéronautique - Méthodes d'essais - Partie 407 : Tenue à la Verwendung - Prüfverfahren - Teil 407: Entflammbarkeit
flamme
This European Standard was approved by CEN on 12 September 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 3475-407:2005: E
worldwide for CEN national Members.

---------------------- Page: 2 ----------------------

EN 3475-407:2005 (E)
Contents Page
Foreword .3
1 Scope.4
2 Normative references.4
3 Equipment.4
4 Procedures.5
4.1 Method 1.5
4.2 Method 2.7
4.3 Completion of test (methods 1 and 2) .9
5 Acceptance criteria.9
5.1 Method 1.9
5.2 Method 2.9

2

---------------------- Page: 3 ----------------------

EN 3475-407:2005 (E)
Foreword
This European Standard (EN 3475-407:2005) has been prepared by the European Association of Aerospace
Manufacturers - Standardization (AECMA-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of
AECMA, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by April 2006, and conflicting national standards shall be withdrawn at the
latest by April 2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This European Standard supersedes EN 3475-407:2002.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland
and the United Kingdom.
3

---------------------- Page: 4 ----------------------

EN 3475-407:2005 (E)
1 Scope
This standard specifies two methods of determining the flammability characteristics of a finished cable.
It shall be used together with EN 3475-100.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 3475-100, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 100: General.
3 Equipment
The following equipment shall be required for these tests:
a) Test chamber: this shall be a chamber measuring not less than 700 mm high × 500 mm wide × 300 mm
deep, enclosed at the top, open at the front and situated in a draught-free environment but with sufficient
air s
...