SIST ISO 11264:2006
(Main)Soil quality -- Determination of herbicides -- Method using HPLC with UV-detection
Soil quality -- Determination of herbicides -- Method using HPLC with UV-detection
ISO 11264:2005 specifies a high-performance liquid chromatography (HPLC) method for qualitative and quantitative determination of herbicides of various substance classes in soils. This method covers triazines including their related metabolites, phenyl urea compounds and other herbicides. Compounds are identified and quantified with UV-detection.
Qualité du sol -- Dosage des herbicides -- Méthode par CLHP avec détection par UV
L'ISO 11264:2005 spécifie une méthode de chromatographie liquide à haute performance (CLHP) pour le dosage qualitatif et quantitatif des herbicides dans différentes classes de substances contenues dans le sol. Cette méthode traite des triazines ainsi que des métabolites qui leur sont associés, des composés à base de phénylurées et d'autres herbicides. Les composés sont identifiés et quantifiés par détection UV.
Kakovost tal – Določevanje herbicidov – Metoda tekočinske kromatografije visoke ločljivosti z ultravijolično detekcijo
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2006
.DNRYRVWWDO±'RORþHYDQMHKHUELFLGRY±0HWRGDWHNRþLQVNHNURPDWRJUDILMHYLVRNH
ORþOMLYRVWL]XOWUDYLMROLþQRGHWHNFLMR
Soil quality -- Determination of herbicides -- Method using HPLC with UV-detection
Qualité du sol -- Dosage des herbicides -- Méthode par CLHP avec détection par UV
Ta slovenski standard je istoveten z: ISO 11264:2005
ICS:
13.080.10 .HPLMVNH]QDþLOQRVWLWDO Chemical characteristics of
soils
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERNATIONAL ISO
STANDARD 11264
First edition
2005-05-01
Soil quality — Determination of
herbicides — Method using HPLC with
UV-detection
Qualité du sol — Dosage des herbicides — Méthode par CLHP avec
détection par UV
Reference number
©
ISO 2005
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2005 – All rights reserved
Contents Page
Foreword. iv
1 Scope. 1
2 Normative reference . 1
3 Principle . 1
4 Reagents . 1
5 Apparatus. 4
6 Procedure. 5
6.1 Sample preparation. 5
6.2 Sample preservation and pretreatment . 5
6.3 Addition of water to the sample . 5
6.4 Preparation of soil extract. 6
6.5 HPLC-determination . 6
7 Calculation. 9
7.1 Calculation of the mass concentration ρ of the substance in extract solution E2
EX
according to Equation (2). 9
7.2 Calculation of the content w of the substance in the soil extract solution E2 according to
Equation (3) . 10
7.3 Expression of results. 10
8 Test report. 10
9 Accuracy . 10
Annex A (informative) Chromatograms. 11
Annex B (normative) Validation . 13
Annex C (informative) Additional compounds which were tested with this method
(see 6.4 and 6.5) . 16
Bibliography . 17
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11264 was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3, Chemical
methods and soil characteristics.
iv © ISO 2005 – All rights reserved
INTERNATIONAL STANDARD ISO 11264:2005(E)
Soil quality — Determination of herbicides — Method using
HPLC with UV-detection
1 Scope
This International Standard specifies a high-performance liquid chromatography (HPLC) method for qualitative
and quantitative determination of herbicides of various substance classes in soils. This method covers
triazines including their related metabolites, phenyl urea compounds and other herbicides. Compounds are
identified and quantified with UV-detection.
The limit of detection for triazines and phenyl urea compounds is ~ 0,01 mg/kg dry matter. It is dependent
upon both the compound and the soil matrix.
2 Normative reference
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 10381-1, Soil quality — Sampling —- Part 1: Guidance on the design of sampling programmes
ISO 10381-2, Soil quality — Sampling — Part 2: Guidance on sampling techniques
ISO 11465, Soil quality — Determination of dry matter and water content on a mass basis — Gravimetric
method
ISO 14507, Soil quality — Pretreatment of samples for determination of organic contaminants
3 Principle
The field-moist soil sample is extracted with a mixture of acetone and water (2:1). After addition of NaCl and
dichloromethane or petroleum, the isolated organic phase is concentrated and transferred to a
acetonitrile/water mixture and without further clean-up is analysed using RP-HPLC, gradient of acetonitrile and
water, with UV-detection. Results can be confirmed using diode array UV spectra, GC-MS, GC-NPD or
GC-AED (some may need derivatisation).
4 Reagents
All reagents shall be of known analytical grade. The purity of the reagents used shall be checked by running a
blank determination as described in 6.5. If the blank value is unreasonably high, i.e. more than 10 % of the
lowest value of interest, find the cause through a step-by-step examination of the whole procedure. For
measurements at the limit of determination, even reagents suitable for residue analyses may not fulfil this
criterion. In this case, sufficient blank determinations shall be incorporated in each series of samples.
4.1 Water, for residue analysis, normally tap water (drinking water) is suitable.
4.2 Acetone, for residue analysis.
4.3 Sodium chloride.
4.4 Dichloromethane, for residue analysis.
4.5 Petroleum ether, boiling range 40 °C to 60 °C, for residue analysis.
4.6 Sodium sulfate, anhydrous, for residue analysis.
4.7 Acetonitrile, HPLC grade.
4.8 Water, HPLC grade.
4.9 2-propanol, for chromatography.
4.10 Acetonitrile (4.7)/water (4.8) mixture, 1 + 1 (V + V) for dissolving the sample.
4.11 Methanol, HPLC grade.
4.12 Standard substances (including Chemical Abstracts Number).
Alachlor [015972-60-8], Atrazine [001912-24-9], Atrazine-desethyl [06190-65-4], Atrazine-desisopropyl
[01007-28-9], Bromacil [000314-40-9], Chlortoluron [015545-48-9], Chloroxuron [001982-47-4], Cyanazine
[021725-46-2], Dichlobenil [001194-65-6], Diuron [000330-54-1], Ethofumesate [026225-79-6], Hexazinon
[051235-04-2], Isoproturon [034123-59-6], Metazachlor [061729-08-2], Metamitron [041394-05-2],
Metabenzthiazuron [018691-97-9], Metobromuron [003060-89-7], Metolachlor [051218-45-2], Metoxuron
[019937-59-8], Monuron [000150-68-5], Pendimethalin [040487-42-1], Propazine [000139-40-2], Propyzamide
[023950-58-5], Sebuthylazine [00728-69-3], Simazine [000122-34-9], Terbutryn [000886-50-0], Terbutylazine
[005915-41-3].
4.13 Standard solutions for HPLC determination
4.13.1 Stock solutions, ρ = 1 mg/ml
Weigh 10,0 mg of each standard substance (4.12) and place in individual 10 ml measuring flasks (5.13).
Dissolve with 2-propanol (4.9) or, in the case of sebuthylazine and simazine, with small portions of acetone
(4.2) or, in the case of metamitron, with methanol (4.11). Then make up to the mark with 2-propanol (4.9).
4.13.2 Intermediate dilutions, ρ = 100 µg/ml
Pipette 1,0 ml of each of the stock solutions (4.13.1) into an individual 10 ml measuring flask (5.13) and make
up to the mark with 2-propanol (4.9).
4.13.3 Working solutions I, ρ = 10 µg/ml
NOTE Working solutions are made to establish the retention time. Different concentrations are made because the
analytes have different detector responses.
Pipette 1,0 ml of each of the intermediate dilutions (4.13.2) into an individual 10 ml measuring flask (5.13) and
make up to the mark with acetonitrile/water mixture (4.10).
4.13.4 Working solutions ll, ρ = 1 µg/ml
Transfer, with a microlitre syringe (5.14), 100 µl of each of the intermediate dilutions (4.13.2) into a 10 ml
measuring flask (5.13) and make up to the mark with acetonitrile/water mixture (4.10).
2 © ISO 2005 – All rights reserved
4.13.5 Working solutions lll, ρ = 0,1 µg/ml
Transfer, with a microlitre syringe (5.14), 100 µl of working solution I (4.13.3) into a 10 ml measuring flask
(5.13) and make up to the mark with acetonitrile/water mixture (4.10).
4.13.6 Mixed solutions I, ρ = 5 µg/ml to 100 µg/ml
According to Table 1, transfer with a microlitre syringe (5.14), between 50 µI and 1 000 µl of the stock
solutions (4.13.1) into a 10 ml measuring flask (5.13) and make up to the mark with 2-propanol (4.9).
4.13.7 Mixed solutions ll, ρ = 0,5 µg/ml to 10 µg/ml
Pipette 1,0 ml of the mixed solution I (4.13.6) into a 10 ml measuring flask (5.13) and make up to the mark
with acetonitrile/water mixture (4.10) (see Table 1).
4.13.8 Mixed solutions III, ρ = 0,05 µg/ml to 1 µg/ml
Pipette 1,0 ml of the mixed solution ll (4.13.7) into a 10 ml measuring flask (5.13) and make up to the mark
with acetonitrile/water mixture (4.10).
Table 1 — Concentration of compounds of mixed solutions I (4.13.6), II (4.13.7) and III (4.13.8)
a
b
No. Compound
Volume Mixed solution I Mixed solution II Mixed solution III
µl µg/ml µg/ml µg/ml
1 Atrazine-desisopropyl 200 20 2 0,2
2 Metamitron 500 50 5 0,5
3 Atrazine-desethyl 200 20 2 0,2
4 Hexazinon 200 20 2 0,2
5 Metoxuron 200 20 2 0,2
6 Bromacil 400 40 4 0,4
7 Simazine 100 10 1 0,1
8 Monuron 100 10 1 0,1
9 Cyanazine 100 10 1 0,1
10 Methabenzthiazuron 100 10 1 0,1
11 Chlortoluron 100 10 1 0,1
12 Atrazine 100 10 1 0,1
13 Isoproturon 100 10 1 0,1
14 Diuron 200 20 2 0,2
15 Metobromuron 100 10 1 0,1
16 Metazachlor 500 50 5 0,5
17 Sebuthylazine 100 10 1 0,1
18 Propazine 100 10 1 0,1
19 Dichlobenil 200 20 2 0,2
20 Terbutylazine 100 10 1 0,1
21 Chloroxuron 100 10 1 0,1
22 Propyzamide 100 10 1 0,1
23 Terbutryn 50 5 0,5 0,05
...
INTERNATIONAL ISO
STANDARD 11264
First edition
2005-05-01
Soil quality — Determination of
herbicides — Method using HPLC with
UV-detection
Qualité du sol — Dosage des herbicides — Méthode par CLHP avec
détection par UV
Reference number
©
ISO 2005
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2005 – All rights reserved
Contents Page
Foreword. iv
1 Scope. 1
2 Normative reference . 1
3 Principle . 1
4 Reagents . 1
5 Apparatus. 4
6 Procedure. 5
6.1 Sample preparation. 5
6.2 Sample preservation and pretreatment . 5
6.3 Addition of water to the sample . 5
6.4 Preparation of soil extract. 6
6.5 HPLC-determination . 6
7 Calculation. 9
7.1 Calculation of the mass concentration ρ of the substance in extract solution E2
EX
according to Equation (2). 9
7.2 Calculation of the content w of the substance in the soil extract solution E2 according to
Equation (3) . 10
7.3 Expression of results. 10
8 Test report. 10
9 Accuracy . 10
Annex A (informative) Chromatograms. 11
Annex B (normative) Validation . 13
Annex C (informative) Additional compounds which were tested with this method
(see 6.4 and 6.5) . 16
Bibliography . 17
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11264 was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3, Chemical
methods and soil characteristics.
iv © ISO 2005 – All rights reserved
INTERNATIONAL STANDARD ISO 11264:2005(E)
Soil quality — Determination of herbicides — Method using
HPLC with UV-detection
1 Scope
This International Standard specifies a high-performance liquid chromatography (HPLC) method for qualitative
and quantitative determination of herbicides of various substance classes in soils. This method covers
triazines including their related metabolites, phenyl urea compounds and other herbicides. Compounds are
identified and quantified with UV-detection.
The limit of detection for triazines and phenyl urea compounds is ~ 0,01 mg/kg dry matter. It is dependent
upon both the compound and the soil matrix.
2 Normative reference
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 10381-1, Soil quality — Sampling —- Part 1: Guidance on the design of sampling programmes
ISO 10381-2, Soil quality — Sampling — Part 2: Guidance on sampling techniques
ISO 11465, Soil quality — Determination of dry matter and water content on a mass basis — Gravimetric
method
ISO 14507, Soil quality — Pretreatment of samples for determination of organic contaminants
3 Principle
The field-moist soil sample is extracted with a mixture of acetone and water (2:1). After addition of NaCl and
dichloromethane or petroleum, the isolated organic phase is concentrated and transferred to a
acetonitrile/water mixture and without further clean-up is analysed using RP-HPLC, gradient of acetonitrile and
water, with UV-detection. Results can be confirmed using diode array UV spectra, GC-MS, GC-NPD or
GC-AED (some may need derivatisation).
4 Reagents
All reagents shall be of known analytical grade. The purity of the reagents used shall be checked by running a
blank determination as described in 6.5. If the blank value is unreasonably high, i.e. more than 10 % of the
lowest value of interest, find the cause through a step-by-step examination of the whole procedure. For
measurements at the limit of determination, even reagents suitable for residue analyses may not fulfil this
criterion. In this case, sufficient blank determinations shall be incorporated in each series of samples.
4.1 Water, for residue analysis, normally tap water (drinking water) is suitable.
4.2 Acetone, for residue analysis.
4.3 Sodium chloride.
4.4 Dichloromethane, for residue analysis.
4.5 Petroleum ether, boiling range 40 °C to 60 °C, for residue analysis.
4.6 Sodium sulfate, anhydrous, for residue analysis.
4.7 Acetonitrile, HPLC grade.
4.8 Water, HPLC grade.
4.9 2-propanol, for chromatography.
4.10 Acetonitrile (4.7)/water (4.8) mixture, 1 + 1 (V + V) for dissolving the sample.
4.11 Methanol, HPLC grade.
4.12 Standard substances (including Chemical Abstracts Number).
Alachlor [015972-60-8], Atrazine [001912-24-9], Atrazine-desethyl [06190-65-4], Atrazine-desisopropyl
[01007-28-9], Bromacil [000314-40-9], Chlortoluron [015545-48-9], Chloroxuron [001982-47-4], Cyanazine
[021725-46-2], Dichlobenil [001194-65-6], Diuron [000330-54-1], Ethofumesate [026225-79-6], Hexazinon
[051235-04-2], Isoproturon [034123-59-6], Metazachlor [061729-08-2], Metamitron [041394-05-2],
Metabenzthiazuron [018691-97-9], Metobromuron [003060-89-7], Metolachlor [051218-45-2], Metoxuron
[019937-59-8], Monuron [000150-68-5], Pendimethalin [040487-42-1], Propazine [000139-40-2], Propyzamide
[023950-58-5], Sebuthylazine [00728-69-3], Simazine [000122-34-9], Terbutryn [000886-50-0], Terbutylazine
[005915-41-3].
4.13 Standard solutions for HPLC determination
4.13.1 Stock solutions, ρ = 1 mg/ml
Weigh 10,0 mg of each standard substance (4.12) and place in individual 10 ml measuring flasks (5.13).
Dissolve with 2-propanol (4.9) or, in the case of sebuthylazine and simazine, with small portions of acetone
(4.2) or, in the case of metamitron, with methanol (4.11). Then make up to the mark with 2-propanol (4.9).
4.13.2 Intermediate dilutions, ρ = 100 µg/ml
Pipette 1,0 ml of each of the stock solutions (4.13.1) into an individual 10 ml measuring flask (5.13) and make
up to the mark with 2-propanol (4.9).
4.13.3 Working solutions I, ρ = 10 µg/ml
NOTE Working solutions are made to establish the retention time. Different concentrations are made because the
analytes have different detector responses.
Pipette 1,0 ml of each of the intermediate dilutions (4.13.2) into an individual 10 ml measuring flask (5.13) and
make up to the mark with acetonitrile/water mixture (4.10).
4.13.4 Working solutions ll, ρ = 1 µg/ml
Transfer, with a microlitre syringe (5.14), 100 µl of each of the intermediate dilutions (4.13.2) into a 10 ml
measuring flask (5.13) and make up to the mark with acetonitrile/water mixture (4.10).
2 © ISO 2005 – All rights reserved
4.13.5 Working solutions lll, ρ = 0,1 µg/ml
Transfer, with a microlitre syringe (5.14), 100 µl of working solution I (4.13.3) into a 10 ml measuring flask
(5.13) and make up to the mark with acetonitrile/water mixture (4.10).
4.13.6 Mixed solutions I, ρ = 5 µg/ml to 100 µg/ml
According to Table 1, transfer with a microlitre syringe (5.14), between 50 µI and 1 000 µl of the stock
solutions (4.13.1) into a 10 ml measuring flask (5.13) and make up to the mark with 2-propanol (4.9).
4.13.7 Mixed solutions ll, ρ = 0,5 µg/ml to 10 µg/ml
Pipette 1,0 ml of the mixed solution I (4.13.6) into a 10 ml measuring flask (5.13) and make up to the mark
with acetonitrile/water mixture (4.10) (see Table 1).
4.13.8 Mixed solutions III, ρ = 0,05 µg/ml to 1 µg/ml
Pipette 1,0 ml of the mixed solution ll (4.13.7) into a 10 ml measuring flask (5.13) and make up to the mark
with acetonitrile/water mixture (4.10).
Table 1 — Concentration of compounds of mixed solutions I (4.13.6), II (4.13.7) and III (4.13.8)
a
b
No. Compound
Volume Mixed solution I Mixed solution II Mixed solution III
µl µg/ml µg/ml µg/ml
1 Atrazine-desisopropyl 200 20 2 0,2
2 Metamitron 500 50 5 0,5
3 Atrazine-desethyl 200 20 2 0,2
4 Hexazinon 200 20 2 0,2
5 Metoxuron 200 20 2 0,2
6 Bromacil 400 40 4 0,4
7 Simazine 100 10 1 0,1
8 Monuron 100 10 1 0,1
9 Cyanazine 100 10 1 0,1
10 Methabenzthiazuron 100 10 1 0,1
11 Chlortoluron 100 10 1 0,1
12 Atrazine 100 10 1 0,1
13 Isoproturon 100 10 1 0,1
14 Diuron 200 20 2 0,2
15 Metobromuron 100 10 1 0,1
16 Metazachlor 500 50 5 0,5
17 Sebuthylazine 100 10 1 0,1
18 Propazine 100 10 1 0,1
19 Dichlobenil 200 20 2 0,2
20 Terbutylazine 100 10 1 0,1
21 Chloroxuron 100 10 1 0,1
22 Propyzamide 100 10 1 0,1
23 Terbutryn 50 5 0,5 0,05
24 Ethofumesate 500 50 5 0,5
25 Metolachlor 500 50 5 0,5
26 Alachlor 1 000 100 10 1
27 Pendimethalin 100 10 1 0,1
a
Compounds are in elution order using the conditions stated in 6.5. For additional compounds, see Annex C.
b
Volume to be taken from the stock solution (4.13.1) to prepare 10 ml of the mixed solution I (4.13.6).
5 Apparatus
5.1 Glass bottles, with screw cap and sealing ring of polytetrafluor ethylene, nominal capacity 250 ml and
1 000 ml.
5.2 Extraction apparatus (see Figure 1), consisting of the following.
5.2.1 Measuring cylinder, of 1 000 ml nominal volume with ground neck and ground-glass stopper.
5.2.2 Ground-glass insert (wash-bottle principle) with adjustable U-tube, the bent end of which can be
placed at the interface between the two phase
...
NORME ISO
INTERNATIONALE 11264
Première édition
2005-05-01
Qualité du sol — Dosage des
herbicides — Méthode par CLHP avec
détection par UV
Soil quality — Determination of herbicides — Method using HPLC with
UV-detection
Numéro de référence
©
ISO 2005
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2005
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Version française parue en 2007
Publié en Suisse
ii © ISO 2005 – Tous droits réservés
Sommaire Page
Avant-propos. iv
1 Domaine d'application. 1
2 Références normatives . 1
3 Principe. 1
4 Réactifs . 2
5 Appareillage . 4
6 Mode opératoire . 6
6.1 Préparation des échantillons. 6
6.2 Conservation et prétraitement des échantillons . 6
6.3 Ajout d'eau à l'échantillon. 6
6.4 Préparation de l'extrait de sol. 7
6.5 Dosage par CLHP. 7
7 Calculs . 10
7.1 Calcul de la concentration massique ρ de la substance dans l'extrait E2 à l'aide
EX
de l'Équation (2) . 10
7.2 Calcul de la teneur w de la substance dans l'extrait de sol E2 à l'aide de l'Équation (3). 11
7.3 Expression des résultats . 11
8 Rapport d'essai . 11
9 Justesse. 11
Annexe A (informative) Chromatogrammes . 12
Annexe B (normative) Validation.14
Annexe C (informative) Autres composants soumis à essai suivant la présente méthode (voir 6.4
et 6.5). 17
Bibliographie . 18
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 11264 a été élaborée par le comité technique ISO/TC 190, Qualité du sol, sous-comité SC 3, Méthodes
chimiques et caractéristiques du sol.
iv © ISO 2005 – Tous droits réservés
NORME INTERNATIONALE ISO 11264:2005(F)
Qualité du sol — Dosage des herbicides — Méthode par CLHP
avec détection par UV
1 Domaine d'application
La présente Norme internationale spécifie une méthode de chromatographie liquide à haute performance
(CLHP) pour le dosage qualitatif et quantitatif des herbicides dans différentes classes de substances
contenues dans le sol. Cette méthode traite des triazines ainsi que des métabolites qui leur sont associés,
des composés à base de phénylurées et d'autres herbicides. Les composés sont identifiés et quantifiés par
détection UV.
La limite de détection des triazines et des composés à base de phénylurées est d'environ 0,01 mg/kg de
matière sèche. Elle varie en fonction tant du composé que de la matrice du sol.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 10381-1, Qualité du sol — Échantillonnage — Partie 1: Lignes directrices pour l'établissement des
programmes d'échantillonnage
ISO 10381-2, Qualité du sol — Échantillonnage — Partie 2: Lignes directrices pour les techniques
d'échantillonnage
ISO 11465, Qualité du sol — Détermination de la teneur pondérale en matière sèche et en eau — Méthode
gravimétrique
ISO 14507, Qualité du sol — Prétraitement des échantillons pour la détermination des contaminants
organiques
3 Principe
Extraction d'un échantillon de sol humide à l'aide d'un mélange d'acétone et d'eau (2:1). Après addition de
NaCl et de dichlorométhane ou d'éther de pétrole, concentration de la phase organique isolée et transfert
dans un mélange d'acétonitrile et d'eau, puis, sans autre purification, analyse par chromatographie à haute
performance en phase inverse (CLHP – PI) avec gradient d'acétonitrile et d'eau et détection UV. Confirmation
des résultats par détecteur UV à barrette de diodes, chromatographie en phase gazeuse couplée à la
spectrométrie de masse (CPG-MS), chromatographie en phase gazeuse avec détecteur azote/phosphore
(CPG-NPD) ou à émission atomique (CPG-AED) (certaines méthodes pouvant nécessiter une dérivatisation).
4 Réactifs
Tous les réactifs doivent être de qualité analytique reconnue. La pureté des réactifs utilisés doit être vérifiée
par un dosage à blanc du type décrit en 6.5. Si la valeur du blanc est déraisonnablement élevée, c'est-à-dire
supérieure à 10 % de la valeur d'intérêt la plus basse, il faut en trouver la cause en analysant tout le mode
opératoire étape par étape. Pour les mesurages effectués à la limite de détermination, même des réactifs
adaptés à l'analyse des résidus peuvent ne pas respecter ce critère. Dans ce cas, des dosages de blanc
suffisants doivent être introduits dans chaque série d'échantillons.
4.1 Eau, pour analyse des résidus; l'eau du robinet (eau potable) est généralement utilisable.
4.2 Acétone, pour analyse des résidus.
4.3 Chlorure de sodium.
4.4 Dichlorométhane, pour analyse des résidus.
4.5 Éther de pétrole, pour analyse des résidus, plage d'ébullition de 40 °C à 60 °C.
4.6 Sulfate de sodium, anhydre, pour analyse des résidus.
4.7 Acétonitrile, qualité pour CLHP.
4.8 Eau, qualité pour CLHP.
4.9 2-Propanol, pour chromatographie.
4.10 Mélange acétonitrile (4.7)/eau (4.8), 1 + 1 (V + V) pour mise en solution de l'échantillon.
4.11 Méthanol, qualité pour CLHP.
4.12 Substances étalons (avec leur numéro CAS).
Alachlore [015972-60-8], Atrazine [001912-24-9], Atrazine-deséthyl [06190-65-4], Atrazine-désisopropyl
[01007-28-9], Bromacil [000314-40-9], Chlortoluron [015545-48-9], Chloroxuron [001982-47-4], Cyanazine
[021725-46-2], Dichlobénil [001194-65-6], Diuron [000330-54-1], Éthofumesate [026225-79-6], Hexazinone
[051235-04-2], Isoproturon [034123-59-6], Métazachlore [061729-08-2], Métamitrone [041394-05-2],
Métabenzthiazuron [018691-97-9], Métobromuron [003060-89-7], Métolachlore [051218-45-2], Métoxuron
[019937-59-8], Monuron [000150-68-5], Pendiméthaline [040487-42-1], Propazine [000139-40-2],
Propyzamide [023950-58-5], Sébuthylazine [00728-69-3], Simazine [000122-34-9], Terbutryne [000886-50-0],
Terbuthylazine [005915-41-3].
4.13 Solutions étalons pour dosage par CLHP.
4.13.1 Solutions mères, ρ = 1 mg/ml
Peser 10,0 mg de chaque substance étalon (4.12) et les placer dans des fioles jaugées de 10 ml (5.13).
Mettre en solution avec du 2-propanol (4.9) ou, dans le cas de la sébuthylazine et de la simazine, avec de
petites portions d'acétone (4.2) ou encore, dans le cas de la métamitrone, avec du méthanol (4.11).
Compléter ensuite au trait repère avec du 2-propanol (4.9).
4.13.2 Solutions intermédiaires, ρ = 100 µg/ml
Verser à la pipette 1,0 ml de chacune des solutions mères (4.13.1) dans une fiole jaugée de 10 ml (5.13) et
compléter au trait repère avec du 2-propanol (4.9).
2 © ISO 2005 – Tous droits réservés
4.13.3 Solutions de travail I, ρ = 10 µg/ml
NOTE Les solutions de travail servent à déterminer le temps de rétention. Les concentrations sont différentes, car les
substances analysées ont des coefficients de réponse différents.
Verser à la pipette 1,0 ml de chacune des dilutions intermédiaires (4.13.2) dans une fiole jaugée de 10 ml
(5.13) et compléter au trait repère avec le mélange d'acétonitrile et d'eau (4.10).
4.13.4 Solutions de travail ll, ρ = 1 µg/ml
Transférer, à l'aide d'une microseringue (5.14), 100 µl de chacune des dilutions intermédiaires (4.13.2) dans
une fiole jaugée de 10 ml (5.13) et compléter au trait repère avec le mélange d'acétonitrile et d'eau (4.10).
4.13.5 Solutions de travail lll, ρ = 0,1 µg/ml
Transférer, à l'aide d'une microseringue (5.14), 100 µl de la solution de travail I (4.13.3) dans une fiole jaugée
de 10 ml (5.13) et compléter au trait repère avec le mélange d'acétonitrile et d'eau (4.10).
4.13.6 Solutions mixtes I, ρ = 5 µg/ml à 100 µg/ml
Conformément au Tableau 1, transférer, à l'aide d'une microseringue (5.14), entre 50 µI et 1 000 µl des
solutions mères (4.13.1) dans une fiole jaugée de 10 ml (5.13) et compléter au trait repère avec du 2-propanol
(4.9).
4.13.7 Solutions mixtes ll, ρ = 0,5 µg/ml à 10 µg/ml
Verser à la pipette 1,0 ml de la solution mixte I (4.13.6) dans une fiole jaugée de 10 ml (5.13) et compléter au
trait repère avec le mélange d'acétonitrile et d'eau (4.10) (voir Tableau 1).
4.13.8 Solutions mixtes III, ρ = 0,05 µg/ml à 1 µg/ml
Verser à la pipette 1,0 ml de la solution mixte ll (4.13.7) dans une fiole jaugée de 10 ml (5.13) et compléter au
trait repère avec le mélange d'acétonitrile et d'eau (4.10).
Tableau 1 — Concentration des composés des solutions mixtes I (4.13.6), II (4.13.7) et III (4.13.8)
a b
N° Composé Volume Solution mixte I Solution mixte II Solution mixte III
µl µg/ml µg/ml µg/ml
1 Atrazine-désisopropyl 200 20 2 0,2
2 Métamitrone 500 50 5 0,5
3 Atrazine-deséthyl 200 20 2 0,2
4 Hexazinone 200 20 2 0,2
5 Métoxuron 200 20 2 0,2
6 Bromacil 400 40 4 0,4
7 Simazine 100 10 1
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.