Insulating, sheathing and covering materials for low voltage energy cables -- Part 5: Halogen-free, cross-linked insulating compounds

This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free, cross-linked insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series, EN 50267-2 (series), EN 60684-2 and EN 50396.

Isolier-, Mantel- und Umhüllungswerkstoffe für Niederspannungskabel und -leitungen -- Teil 5: Halogenfreie, vernetzte Isoliermischungen

Dieser Teil der EN 50363 legt die Anforderungen an halogenfreie, vernetzte Isoliermischungen fest, die in Tabelle 1 aufgeführt sind. Die entsprechenden Prüfverfahren sind in den Normen der Reihe EN 60811, der  Reihe EN 50267-2, EN60684-2 und EN 50396  beschrieben.

Matériaux pour enveloppe isolante, gainage et revêtement pour les câbles d'énergie basse tension -- Partie 5: Mélanges réticulés sans halogène pour enveloppe isolante

La présente partie de la EN 50363 mentionne les exigences des essais pour les propriétés physiques de mélange(s) réticulé(s) sans halogène pour enveloppe isolante, donnés dans le Tableau 1. Les méthodes d’essais appropriées sont données dans la série EN 60811, la série EN 50267 2, la EN 60684 2 et la EN 50396.

Materiali za izoliranje, oplaščenje in prevleke nizkonapetostnih energetskih kablov - 5. del: Omrežene mase za izoliranje brez halogenov

General Information

Status
Published
Publication Date
30-Sep-2006
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Oct-2006
Due Date
01-Oct-2006
Completion Date
01-Oct-2006

Relations

Overview

EN 50363-5:2005 (CLC) specifies the physical property requirements for halogen‑free, cross‑linked insulating compounds used in low voltage energy cables. It is part of the EN 50363 series and is intended to be read in conjunction with EN 50363-0. The standard defines harmonised material types, required test methods and pass/fail limits for material performance (mechanical, thermal, ozone and halogen content) using referenced test standards.

Key topics and technical requirements

  • Material types and operating temperatures
    • EI 5 - ordinary duty insulating compound, maximum operating temperature 90 °C
    • EI 8 - ordinary duty for flexible cables, maximum operating temperature 70 °C
  • Mechanical properties (EN 60811 test methods)
    • Tensile strength (median, minimum): EI 5 = 10.0 N/mm², EI 8 = 5.0 N/mm²
    • Elongation at break (median, minimum): 125% for both types
    • Ageing in air oven: EI 5 at 135 ±2 °C, EI 8 at 110 ±2 °C, duration 7 × 24 h; variation limits apply
  • Hot set test
    • Test conditions: 200 ±3 °C, 15 min under load, mechanical stress 20 N/cm²
    • Performance limits: max elongation under load 100%, max elongation after unloading 25%
  • Low temperature performance
    • Bending and elongation tests at −15 ±2 °C; elongation without break ≥ 30%
  • Ozone resistance
    • Method A and Method B options with defined temperatures, durations and ozone concentrations (tests per EN 60811 / EN 50396)
  • Halogen assessment (EN 50267-2, EN 60684-2)
    • pH: ≥ 4.3
    • Conductivity: ≤ 10 µS/mm
    • Acid gas limits: HCl/HBr ≤ 0.5%, HF ≤ 0.1%
  • Note: Smoke emission requirements are specified in the relevant cable standards (tests on completed cables), not in this materials standard.

Applications and who uses it

  • Cable manufacturers specifying or qualifying halogen-free cross-linked insulation for low-voltage power cables
  • Material suppliers and compound formulators demonstrating compliance with EU harmonised material requirements
  • Test laboratories performing EN 60811, EN 50267-2, EN 60684-2 and EN 50396 test methods
  • Procurement engineers, specifiers and regulatory bodies requiring documented material performance for safety and reduced halogen content

Related standards

  • EN 50363-0 (general requirements for insulating, sheathing and covering materials)
  • EN 60811 series (material test methods)
  • EN 50267-2 series, EN 60684-2, EN 50396 (halogen and related test methods)
  • Relevant cable standards (for smoke emission and full-cable testing)

EN 50363-5:2005 is essential when specifying or verifying halogen‑free insulating compounds for low voltage energy cables and ensures standardized, testable criteria for safety and material performance.

Standard
SIST EN 50363-5:2006
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 50363-5:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Insulating, sheathing and covering materials for low voltage energy cables -- Part 5: Halogen-free, cross-linked insulating compounds". This standard covers: This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free, cross-linked insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series, EN 50267-2 (series), EN 60684-2 and EN 50396.

This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free, cross-linked insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series, EN 50267-2 (series), EN 60684-2 and EN 50396.

SIST EN 50363-5:2006 is classified under the following ICS (International Classification for Standards) categories: 29.035.20 - Plastics and rubber insulating materials; 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50363-5:2006 has the following relationships with other standards: It is inter standard links to SIST EN 50363-5:2006/A1:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50363-5:2006 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 50363-5:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI SIST EN 50363-5:2006

STANDARD
oktober 2006
Materiali za izoliranje, oplaščenje in prevleke nizkonapetostnih energetskih
kablov - 5. del: Omrežene mase za izoliranje brez halogenov
Insulating, sheathing and covering materials for low voltage energy cables - Part 5:
Halogen-free, cross-linked insulating compounds
ICS 29.035.20; 29.060.20 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 50363-5
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2005

ICS 29.035.20
English version
Insulating, sheathing and covering materials
for low voltage energy cables
Part 5: Halogen-free, cross-linked insulating compounds

Matériaux pour enveloppe isolante, Isolier-, Mantel- und
gainage et revêtement pour les câbles Umhüllungswerkstoffe für
d'énergie basse tension Niederspannungskabel und -leitungen
Partie 5: Mélanges réticulés sans Teil 5: Halogenfreie, vernetzte
halogène pour enveloppe isolante Isoliermischungen

This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50363-5:2005 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50363-5
on 2005-11-01.
EN 50363 (in all its parts) supersedes the equivalent information at present in HD 21.1 S4,
HD 21.14 S1, HD 22.1 S4, HD 22.10 S1, HD 22.14 S2 and prHD 21.15 S1. The existing information in
these HDs will be deleted at the next maintenance review.
EN 50363-5 should be read in conjunction with EN 50363-0.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-11-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-11-01

– 3 – EN 50363-5:2005
Contents
1 Scope.4
2 Normative references.4
3 Definitions.4
4 Properties.4
Table 1 – Types of halogen-free cross-linked insulating compound.4
Table 2 – Requirements for the tests for halogen-free crosslinked insulating compounds .5

1 Scope
This part of EN 50363 specifies the requirements for the physical properties of the harmonised
halogen-free, cross-linked insulating compounds given in Table 1. The relevant test me
...

Questions, Comments and Discussion