SIST EN 60598-2-2:1999
(Main)Luminaires - Part 2: Particular requirements - Section 2: Recessed luminaires (IEC 60598-2-2:1996)
Luminaires - Part 2: Particular requirements - Section 2: Recessed luminaires (IEC 60598-2-2:1996)
specfies requirements for recessed luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltage not exceeding 1000 V.
Leuchten - Teil 2: Besondere Anforderungen - Hauptabschnitt 2: Einbauleuchten (IEC 60598-2-2:1996)
Luminaires - Partie 2: Règles particulières - Section 2: Luminaires encastrés (CEI 60598-2-2:1996)
specifie les prescriptions applicables aux luminaires encastrés à utiliser avec des lampes tubulaires fluorescents et autres lampes à décharge pour des tensions ne dépassant pas 1000 V.
Svetilke - 2. del: Posebne zahteve - 2. oddelek: Vgradne svetilke (IEC 60598-2-2:1996)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 60598-2-2:1999
01-julij-1999
1DGRPHãþD
SIST EN 60598-2-2:1992/A2:1996
SIST EN 60598-2-2:1995
Svetilke - 2. del: Posebne zahteve - 2. oddelek: Vgradne svetilke (IEC 60598-2-
2:1996)
Luminaires - Part 2: Particular requirements - Section 2: Recessed luminaires (IEC
60598-2-2:1996)
Leuchten - Teil 2: Besondere Anforderungen - Hauptabschnitt 2: Einbauleuchten (IEC
60598-2-2:1996)
Luminaires - Partie 2: Règles particulières - Section 2: Luminaires encastrés (CEI 60598-
2-2:1996)
Ta slovenski standard je istoveten z: EN 60598-2-2:1996
ICS:
29.140.40 Svetila Luminaires
SIST EN 60598-2-2:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 60598-2-2:1999
---------------------- Page: 2 ----------------------
SIST EN 60598-2-2:1999
---------------------- Page: 3 ----------------------
SIST EN 60598-2-2:1999
---------------------- Page: 4 ----------------------
SIST EN 60598-2-2:1999
---------------------- Page: 5 ----------------------
SIST EN 60598-2-2:1999
---------------------- Page: 6 ----------------------
SIST EN 60598-2-2:1999
NORME
CEI
INTERNATIONALE
IEC
598-2-2
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
1996-05
Luminaires -
Partie 2:
Règles particulières -
Section 2: Luminaires encastrés
Luminaires -
Part 2:
Particular requirements -
Section 2: Recessed luminaires
© CEI 1996 Droits de reproduction réservés — Copyright — all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun pro- any form or by any means, electronic or mechanical,
cédé, électronique ou mécanique, y compris la photocopie et including photocopying and microfilm, without permission
les microfilms, sans l'accord écrit de l'éditeur.
in writing from the publisher.
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé
Genève, Suisse
Commission Electrotechnique Internationale
CODE PRIX
International Electrotechnical Commission
H
PRICE CODE
IEC
McN(AyHapoQHaR 3tteKrpoTeXHH gecKaR HOMHCCHR
Pour prix,
• voir catalogue en vigueur ^
For price, see current catalogue
---------------------- Page: 7 ----------------------
SIST EN 60598-2-2:1999
598-2-2 © IEC:1996
–3-
CONTENTS
Page
FOREWORD 5
SECTION 2: RECESSED LUMINAIRES
Clause
2.1 Scope 7
2.2 General test requirements 7
2.3 Definitions 7
2.4 Classification of luminaires 7
2.5 Marking 7
2.6 Construction 9
2.7 Creepage distances and clearances 9
2.8 Provision for earthing 9
2.9 Terminals 9
2.10 External and internal wiring 9
2.11 Protection against electric shock 11
2.12 Endurance tests and thermal tests 11
2.13 Resistance to dust and moisture 13
2.14 Insulation resistance and electric strength 13
2.15 Resistance to heat, fire and tracking 13
Annex A – Measurement of ambient temperature in an installation 15
---------------------- Page: 8 ----------------------
SIST EN 60598-2-2:1999
598-2-2 © IEC:1996 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
LUMINAIRES —
Part 2: Particular requirements —
Section 2: Recessed luminaires
FOREWORD
1)
The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international cooperation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising with
the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2)
The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on which
all the National Committees having a special interest therein are represented, express, as nearly as possible, an
international consensus of opinion on the subjects dealt with.
3) They have the form of recommendations for international use published in the form of standards, technical
report
s or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
6) The IEC has not laid down any procedure concerning marking as an indication of approval and has no
responsibility when an item of equipment is declared to comply with one of its standards.
International Standard IEC 598-2-2 has been prepared by subcommittee 34D: Luminaires, of
IEC technical committee 34: Lamps and related equipment.
This second edition cancels and replaces the first edition published in 1979, amendment 1
(1987) and amendment 2 (1991). This second edition constitutes a technical revision.
The text of this standard is based on the first edition, amendment 1 and amendment 2, and the
following documents:
FDIS
Report on voting
34D/394/FDIS 34D/409/RV D
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annex A is for information only.
This publication shall be read in conjunction with IEC 598-1: Luminaires – Part 1: General
requirements and tests.
---------------------- Page: 9 ----------------------
SIST EN 60598-2-2:1999
598-2-2 © IEC:1996 – 7 –
LUMINAIRES -
Part 2: Particular requirements -
Section 2: Recessed luminaires
2.1 Scope
This section of IEC 598-2 specifies requirements for recessed luminaires for use with tungsten
filament, tubular fluorescent and other discharge lamps on supply voltage not exceeding
1000 V. This section does not cover air-handing luminaires. This section does not apply to air-
handling or liquid-cooled luminaires.
2.1.1
Normative references
The following normative documents contains provisions which, through reference in this text,
constitute provisions of this section of IEC 598-2. At the time of publication, the editions
indicated were valid. All normative documents are subject to revision, and parties to
agreements based on this section of IEC 598-2 are encouraged to investigate the possibility of
applying the most recent editions of the normative document indicated below. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 227:
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
IEC 245:
Rubber insulated cables of rated voltages up to and including 450/750 V
2.2 General test requirements
The provisions of section 0 of IEC 598-1 apply. The tests described in each appropriate section
of part 1 shall be carried out in the order listed in this section of part 2.
A procedure measuring ambient temperature in an installation is given in annex A.
2.3 Definitions
For the purposes of this section, the definitions of section 1 of IEC 598-1 apply.
2.4 Classification of luminaires
Luminaires shall be classified in accordance with the provisions of section 2 of IEC 598-1.
2.5 Marking
The provisions of section 3 of IEC 598-1 apply, together with the following additional markings
requirements:
2.5.1 Insulating ceiling F mark, symbol V
Recessed luminaire suitable for mounting in normally flammable su
rfaces where thermal insulating
materia
...
Questions, Comments and Discussion