IEC 60704-2-2:2023 is available as IEC 60704-2-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-2-2:2023 applies to electric fan heaters, designed for placing on the floor, table or counter, etc., or for mounting. This document does not apply to: - electric storage room heaters; - room humidifiers; - room dehumidifiers; - air cleaners; - heaters designed exclusively for industrial purposes. For determining and verifying noise emission values declared in product specifications, refer to IEC 60704-3:2019. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with the latest edition of IEC 60704-1:2021, - addition of several ISO standards, - revision of built-in-conditions, - addition of requirements on climatic conditions and on background noise. This part 2-2 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements. This part 2-2 supplements or modifies the corresponding clauses in IEC 60704-1:2021.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Standard specifies methods for measuring the performance of electric storage water heaters to produce domestic potable or non-potable hot water for household and similar use. The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics. NOTE 1 This standard does not apply to; - storage water heaters that use electricity as a secondary source of heating the water; - storage water heaters that do not use a tank to storage hot water; - electric storage water heaters that do not meet the minimum (or maximum) output performance of the smallest (or biggest) load profile, as defined in Table 4. - water-heaters without thermal insulation NOTE 2 This standard does not specify safety requirements. For safety requirements see IEC 60335-1 in conjunction with IEC 60335-2-21.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-18:2022 applies to single-unit electric water heaters for household and similar use intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter. This document does not apply to: – combustion water heaters; – water kettles; – heat pump water heaters; – conventional electric storage water heaters as defined in IEC 60335-2-21:2012, Clause 1; – instantaneous electric water heaters without any noise-producing components such as motors and pumps. This document is intended to be used in conjunction with IEC 60704‑1:2021.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of IEC 63159-1:2021 is applicable except as follows. Addition: This document applies to open outlet, single point-of-use, electric instantaneous water heaters intended for household or similar use, for showering purposes without downstream mixing. This document only specifies tests for the assessment of energy efficiency. This document does not apply to electrical instantaneous water heaters covered by other parts of this series of standards.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to electric instantaneous water heaters for domestic hot water heating for household and similar applications, which show both of the following characteristics: - fulfilling at least one load pattern from Annex A; - heating up to temperatures below the boiling temperature. This document specifies terms, definitions and measurement methods for the assessment of energy efficiency. This document does not take into account requirements regarding the safety of the appliances.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of IEC 63159-1:2021 is applicable with the following exception: Addition: This document applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with an electric rated power > 2 kW. This document specifies tests for the assessment of the performance.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to electric direct -acting room heaters. They may be portable,
stationary, fixed, or built-in.
It does not apply to:
— thermal-storage room heaters (IEC 531);
- heating appliances incorporated in the building structure;
- central heating systems;
— heaters connected to an air duct;
- wall-paper, carpets or drapes incorporating flexible heating elements.
This standard defines the main performance characteristics of direct-acting room
heaters and specifies methods for measuring these characteristics, for the information of
users.
This standard does not specify values for performance characteristics.
NOTE - This standard does not deal with:
- safety requirements (IEC 335-2-30);
acoustical noise of fan heaters (IEC 704-2-2).

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60675-2:2020 applies to electric direct-acting room heaters. This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiant factor for the information of users. This document is used to measure the radiant factor of direct-acting room heaters. This International Standard is to be used in conjunction with IEC 60675:1994, IEC 60675:1994/AMD1:1998 and IEC 60675:1994/AMD2:2018.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60675-3:2020 applies to electric direct-acting room heaters. This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiation efficiency for the information of users. This document is used to measure the radiation efficiency of direct-acting room heaters. This International Standard is to be used in conjunction with IEC 60675:1994, IEC 60675:1994/AMD1:1998 and IEC 60675:1994/AMD2:2018.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60299:2014 applies to electric blankets, wraps and duvets for household use. This International Standard defines the main performance characteristics of electric blankets, wraps and duvets and specifies methods for measuring these characteristics, for the information of users. This International Standard does not specify values for performance characteristics. This edition includes the following significant technical changes with respect to the previous edition: a) extended classification; b) extended list of measurements; c) temperature measurement means changed to thermocouples.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61255:2014 applies to electric heating pads for household use. This International Standard defines the main performance characteristics of electric heating pads and specifies methods for measuring these characteristics, for the information of users. This International Standard does not specify values for performance characteristics. This edition includes the following significant technical changes with respect to the previous edition: a) extended classification; b) extended list of measurements; c) temperature measurement means changed to thermocouples.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-2:2009 provides the methods of determination of airborne acoustical noise emitted by electric fan heaters, designed for placing on the floor, table or counter,etc., or for wall mounting supplied from mains or from batteries. The main changes from the previous edition are as follows: provisions with regard to measurement uncertainty and standard deviation for declaration and verification have been included in the scope. This publication is to be read in conjunction with IEC 60704-1:2010.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to the electric thermal storage room heaters having forced convection output, designed for placing on the floor, for wall-mounting or for building-in.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to electric direct-acting room heaters. They may be portable, stationary, fixed or built-in. It defines the main performance characteristics and the methods for measuring these characteristics. For thermal-storage room heaters, see IEC 60531.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to hydraulic, closed electrical instantaneous water heaters, for household and similar use. This standard does not apply to storage water heaters (HD 500 S1) and to instantaneous water heaters with electronically controlled power input. This standard specifies definitions and measurement methods for assessing the performance characteristics. It does not deal with safety requirements which are covered by EN 60335-2-35

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Defines the main performance characteristics of electric heating pads and specifies methods for measuring these characteristics, for the information of users. Does not specify values for performance characteristics. Does not deal with safety requirements.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard defines the main performance characteristics of electric blankets and specifies methods for measuring these characteristics, for the information of users. This standard does not specify values for performance characteristics.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

States and defines the principal performance characteristics of electric storage water-heaters which are of interest to the user and to describe the standard methods for measuring these characteristics. This standard is concerned neither with safety nor with performance requirements.

  • Standardization document
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day