NEW!IEC 60099-5:2018 is available as IEC 60099-5:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60099-5:2018 provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure – rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex J, some aspects regarding the old type of SiC gapped arresters are discussed. Surge arrester residual voltage is a major parameter to which most users have paid a lot of attention to when selecting the type and rating. Typical maximum residual voltages are given in Annex F. It is likely, however, that for some systems, or in some countries, the requirements on system reliability and design are sufficiently uniform, so that the recommendations of the present standard may lead to the definition of narrow ranges of arresters. The user of surge arresters will, in that case, not be required to apply the whole process introduced here to any new installation and the selection of characteristics resulting from prior practice may be continued. Annexes H and I present comparisons and calculations between old line discharge classification and new charge classification. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition regarding the new surge arrester classification introduced in IEC 60099-4:2014: a) Expanded discussion of comparison between the old and new classification and how to calculate or estimate the corresponding charge for different stresses. b) New annexes dealing with: - Comparison between line discharge classes and charge classification - Estimation of arrester cumulative charges and energies during line switching Keywords: selection and application of surge arrestors, nominal voltages above 1 kV

  • Standard
    193 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60099-8:2017 is available as IEC 60099-8:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers. This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document: - switching impulse spark-over voltage; - residual voltage at steep current and switching current impulse; - thermal stability; - long-duration current impulse withstand duty; - power-frequency voltage versus time characteristics of an arrester; - disconnector test; - aging duties by power-frequency voltage. Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced. - Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA. - Definitions for new terms have been added - A number of NOTES in Ed. 1 have been converted to normative requirements Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

  • Standard
    70 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60099-4:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits with Us above 1 kV. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. The numerous changes between the second and third editions are listed in the Foreward of the document. Keywords: testing of gapless metal-oxide surge arresters for a.c.power systems

  • Standard
    172 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    174 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed arresters (GIS-arresters) solely used as d.c. bus and d.c. line/cable arresters. Arresters for voltage source converters are not covered. Arresters applied on the a.c. systems at the converter station and subjected to power-frequency voltage of 50 or 60 Hz principally without harmonics are tested as per IEC 60099-4. The arresters on a.c.-filters are tested according to this standard. Keywords: testing of gapless metal-oxide surge arrestors for HVDC converter stations

  • Standard
    92 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Work merged into 37/324/FDIS (pr=16386) * Standstill maintained

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Work merged into 37/324/FDIS (pr=16386) * Standstill maintained

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60099-5:2013(E) is not a mandatory standard but provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure - rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex H, some aspects regarding the old type of SiC gapped arresters are discussed. This second edition cancels and replaces the first edition published in 1996 and its amendment 1 published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Expanded discussion of different types of arresters and their application, including additions of discussion on transmission of line arresters, arresters for shunt capacitor switching arresters for series capacitor protection, application of arresters between phases connecting arresters in parallel; - Addition of section on asset management, including: managing surge arresters in the power grid, arrester maintenance, significantly expanded discussion of performance diagnostic tools, end-of-life considerations; - New annexes dealing with: arrester modelling for system studies, example of data needed for specifying arresters. Key words: selection and application of surge arrestors, nominal voltages above 1 kV

  • Standard
    149 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60099-8:2011 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers. This standard defines surge arresters to protect the insulator assembly from lightning-caused overvoltages only. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this standard.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 60099-4:2014

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 60099-4:2014

  • Amendment
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits.

  • Standard
    156 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 60099-4:2004

  • Amendment
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Superseded by EN 60099-5:2013

  • Amendment
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Corrigendum to be issued taking into account DE & PT comments * Superseded by EN 60099-4:2004

  • Amendment
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Provides recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1kV. It applies to non-linear resistor type gapped surge arresters as defined in EN 60099-1 and to gapless metal-oxide surge arresters as defined in EN 60099-4.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits.

  • Standard
    62 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies, in particular, to surge arresters consisting of single or multiple spark gaps in series with one or more non-linear resistors.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day