IEC 60691:2023 is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions.
NOTE 1 The equipment is not designed to generate heat.
NOTE 2 The effectiveness of the protection against excessive temperatures logically depends upon the position and method of mounting of the thermal-link, as well as upon the current which it is carrying.
This document may be applicable to thermal-links for use under conditions other than indoors, provided that the climatic and other circumstances in the immediate surroundings of such thermal-links are comparable with those in this standard.
This document may be applicable to thermal-links in their simplest forms (e.g. melting strips or wires), provided that molten materials expelled during function cannot adversely interfere with the safe use of the equipment, especially in the case of hand-held or portable equipment, irrespective of its position.

  • Standard
    145 pages
    English language
    sale 15% off
  • Standard
    92 pages
    English language
    sale 15% off
  • Standard
    96 pages
    English and French language
    sale 15% off

IEC 60127-8:2018 relates to fuse resistors with particular overcurrent protection rated up to AC 500 V and/or DC 500 V for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors.
It does not apply to fuse resistors with particular overcurrent protection for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere.
The object of this part of IEC 60127 is
a) to establish uniform requirements for fuse resistors with particular overcurrent protection so as to protect appliances or parts of appliances in the most suitable way;
b) to define the performance of the fuse resistors with particular overcurrent protection, so as to give guidance to manufacturers of electrical appliances and electronic equipment and to ensure replacement of fuse resistors with particular overcurrent protection by those of similar dimensions and characteristics;
c) to establish uniform test methods for fuse resistors with particular overcurrent protection, so as to allow verification of the values (for example rated dissipation, functioning characteristic and rated breaking capacity values) specified by the manufacturer.
This part of IEC 60127 applies in addition to the requirements of IEC 60127-1.
This first edition of IEC 60127-8 cancels and replaces IEC PAS 60127-8:2014.
This international standard is to be used in conjunction with IEC 60127-1.
Keywords: Miniature Fuses, Fuse-Resistors, Overcurrent Protection

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    52 pages
    English language
    sale 15% off
  • Standard
    49 pages
    English and French language
    sale 15% off

IEC 60127-6:2023 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC 60127-2, sub-miniature fuse-links according to IEC 60127-3, universal modular fuse-links to IEC 60127-4 and miniature fuse-links for special applications to IEC 60127-7 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors.
NOTE Requirements for fuse-holders for miniature fuse-links complying with IEC 60127-4 and IEC 60127-7 are under consideration. It does not apply to fuse holders for fuses completely covered by the subsequent parts of IEC 60269-1.

  • Standard
    183 pages
    English language
    sale 15% off
  • Standard
    116 pages
    English and French language
    sale 15% off

IEC 60127-1:2023 covers the general requirements and tests applicable to all types of miniature fuse-links (e.g. cartridge fuse-links, sub-miniature fuse-links, universal modular fuse-links and miniature fuse-links for special applications) for the protection of electric appliances, electronic equipment and component parts thereof normally intended to be used indoors. This document does not apply to fuses intended for the protection of low-voltage electrical installations. These are covered by IEC 60269, Low Voltage Fuses. Specific details covering each major subdivision are given in subsequent parts. This document does not apply to fuses for appliances intended to be used under special conditions, such as in a corrosive or explosive atmos­phere.
The object of this document is
- to establish uniform requirements for miniature fuses so as to protect appliances or parts of appliances in the most suitable way,
- to define the performance of the fuses, so as to give guidance to designers of electrical appliances and electronic equipment and to ensure replacement of fuse-links by those of similar dimensions and characteristics,
- to define methods of testing,
- to define maximum sustained dissipation of fuse-links to ensure good compatibility of stated power acceptance when used with fuse-holders according to this document (see IEC 60127-6).

  • Standard
    112 pages
    English language
    sale 15% off
  • Standard
    71 pages
    English and French language
    sale 15% off

IEC 60127-2:2014 relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions measuring 5 mm x 20 mm and 6,3 mm x 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. It does not apply to cartridge fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This standard applies in addition to the requirements of IEC 60127-1. The object of this standard is to define special and additional test methods for cartridge fuse-links applying in addition to the requirements of IEC 60127-1. This third edition of IEC 60127-2 cancels and replaces the second edition published in 2010. This edition includes the following significant technical changes with respect to the previous edition: add 4 new standard sheets 7 up to 10. Keywords: cartridge fuse-links for miniature fuses, protection of electric appliances, electronic equipment and component
This publication is to be read in conjunction with IEC 60127-1:2006.

  • Standard
    89 pages
    English and French language
    sale 15% off
  • Standard
    196 pages
    English and French language
    sale 15% off
  • Standard
    6 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English and French language
    sale 15% off

IEC 60127-3:2015 is applicable to sub-miniature fuse-links adapted to printed circuits and used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors. It does not apply to sub-miniature fuse-links for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. This standard applies in addition to the requirements of IEC 60127-1. The object of this standard is to define special and additional test methods for sub-miniature fuse-links applying in addition to the requirements of IEC 60127-1. This third edition of IEC 60127-3 cancels and replaces the first edition published in 1988, its Amendment 1 (1991) and Amendment 2 (2002). This edition includes the following significant technical changes with respect to the previous edition:
- add a rectangular shape fuse-link as alternative in standard sheets 3 and 4;
- add a small cartridge fuse-link as alternative in standard sheets 2, 3 and 4;
- add the rated currents up to 10A in standard sheets 2, 3 and 4;
- add Subclause 6.5;
- add Subclause 9.7;
- the extra samples for termination test (E1 to E6) will be chosen by random and not sorted by voltage drop in Table 1, 2, 3, and 4. Keywords: sub-miniature fuse-links adapted to printed circuits, protection of electric appliances, electronic equipment and component parts
This publication is to be read in conjunction with IEC 60127-1:2006.

  • Standard
    64 pages
    English language
    sale 15% off
  • Standard
    60 pages
    English and French language
    sale 15% off
  • Standard
    168 pages
    English and French language
    sale 15% off
  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English and French language
    sale 15% off

IEC 60691:2015 is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions. This standard may be applicable to thermal-links for use under conditions other than indoors, provided that the climatic and other circumstances in the immediate surroundings of such thermal-links are comparable with those in this standard. This standard may be applicable to thermal-links in their simplest forms (e.g. melting strips or wires), provided that molten materials expelled during function cannot adversely interfere with the safe use of the equipment, especially in the case of hand-held or portable equipment, irrespective of its position. Annex H of this standard is applicable to thermal-link packaged assemblies where the thermal-link(s) has already been approved to this standard but packaged in a metallic or non-metallic housing and provided with terminals/wiring leads. This standard is applicable to thermal-links with a rated voltage not exceeding 690 V a.c. or d.c. and a rated current not exceeding 63 A. The objectives of this standard are: to establish uniform requirements for thermal-links, to define methods of test, to provide useful information for the application of thermal-links in equipment. This standard is not applicable to thermal-links used under extreme conditions such as corrosive or explosive atmospheres. This standard is not applicable to thermal-links to be used in circuits on a.c. with a frequency lower than 45 Hz or higher than 62 Hz. This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2010. This fourth edition constitutes a technical revision. This fourth edition includes the following significant technical changes with respect to the previous edition:
- requirements for thermal-link packaged assemblies;
- renew the requirements and definitions for Th-test;
- change starting temperature for interrupt current test;
- clarify requirements for marking (packing label);
- minimum Proof Tracking Index 175 instead 120. Keywords: thermal protection of equipment, thermal-links The contents of the corrigendum of August 2016 have been included in this copy.

  • Standard
    86 pages
    English language
    sale 15% off
  • Standard
    88 pages
    English and French language
    sale 15% off
  • Standard
    176 pages
    English and French language
    sale 15% off

IEC 60127-5:2016 gives a guide for tests for assessing the quality of miniature fuse-links other than type tests, for the case where there is no complete agreement between the user and the manufacturer on what such tests apply. This document provides guidelines and limits generally acceptable for quality control purposes by large scale users and manufacturers of miniature fuse-links. This document has validity for large scale series with lot sizes of 10 000 and more. It is also applicable for smaller lot sizes, if necessary. Periodic inspections by reduced type tests (Clause 5) are intended to be carried out periodically in order to ensure that the level of technical performance previously verified by complete type tests as given in subsequent parts of the IEC 60127 series is maintained. The frequency of periodic in relation to lot-by-lot inspections is not established in this document. This second edition cancels and replaces the first edition published in 1988. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of new tables in 4.3;
- addition of new tables in Clause 5.
Keywords: quality of miniature fuse-links

  • Standard
    25 pages
    English and French language
    sale 15% off

Provides general rules for all electrotechnical components installed in power circuits, control and indicating circuits on rail rolling stock. It supplements the rules given in part 1 of IEC 60077. This part and the part 1 replaces IEC 60077 published in 1968.

  • Standard
    10 pages
    English and French language
    sale 15% off

IEC 60127-7:2015 covers requirements for miniature fuse-links for special applications. This part of IEC 60127 is applicable to fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This part of IEC 60127 applies in addition to the requirements of IEC 60127-1. Miniature fuse-links for special applications are not intended to be replaced by the end-user of an electrical/electronic appliance. The object of this part of IEC 60127 is to establish uniform test methods for miniature fuse-links for special applications, so as to allow verification of the values (for example melting time and breaking capacity values) specified by the manufacturer. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition:
- defining a test board for surface mount fuse-links, Figure 2;
- defining test schedules for homogenous series.
This publication is to be read in conjunction with IEC 60127-1:2006. Keywords: fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    74 pages
    English and French language
    sale 15% off

This part of IEC 60127 covers the general requirements and tests applicable to all types of miniature fuse-links (e.g. cartridge fuse-links, sub-miniature fuse-links and universal modular fuse-links) for the protection of electric appliances, electronic equipment and component parts thereof normally intended to be used indoors.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English language
    sale 15% off

IEC 60127-6:2014 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC 60127-2 and sub-miniature fuse-links according to IEC 60127-3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Examples of fuse-holder types with different features are given. This part of IEC 60127 applies to fuse-holders with:
- a maximum rated current of 16 A; and
- a maximum rated voltage of 1 500 V d.c. or 1 000 V a.c.; and
- for use up to 2 000 m above sea-level, unless otherwise specified. The object of this standard is to establish uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links. This second edition cancels and replaces the first edition published in 1994, its Amendment 1 (1996) and Amendment 2 (2002). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modify the arrangement of the fuse-holder samples in the planes in 13.1.1;
- add a new test 13.2.2: Glow-wire ignition test;
- change maximum gauge size for standard sheets 3 and 4 from 0,70 to 0,63 in table 5;
- change minimum gauge size for standard sheets 3 and 4 from 0,55 to 0,56 in table 5. Keywords: fuse-holders for miniature cartridge fuse-links, sub-miniature fuse-links, protection of electric appliances, electronic equipment and component parts.

  • Standard
    110 pages
    English and French language
    sale 15% off

IEC 60127-7:2013 covers requirements for miniature fuse-links for special applications. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This standard applies in addition to the requirements of IEC 60127-1. This standard is applicable to fuse-links with a rated voltage not exceeding 1000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA. Miniature fuse-links for special applications are not intended to be replaced by the end-user of an electrical/electronic appliance. The object of this standard is to establish uniform test methods for miniature fuse-links for special applications, so as to allow verification of the values (for example melting time and breaking capacity values) specified by the manufacturer. Keywords: requirements for miniature fuse-links
This publication is to be read in conjunction with IEC 60127-1:2006.

  • Standard
    45 pages
    English and French language
    sale 15% off

Specifications for:[
]-single-core non-sheathed cable with rigid conductor for general purposes;[
]-single-core non-sheathed cable with flexible conductor for general purposes;[
]-single-core non-sheathed cable with solid conductor for internal wiring for a conductor temperature of 70°C and 105°C[
]-single-core non-sheathed cable with flexible conductor for internal wiring for a conductor temperature of 70°C and 105°C.

  • Standard
    4 pages
    English and French language
    sale 15% off

Relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions of 5 mm x 20 mm and 6.3 mm x 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors.

  • Standard
    55 pages
    English and French language
    sale 15% off
  • Standard
    65 pages
    English and French language
    sale 15% off
  • Standard
    68 pages
    English and French language
    sale 15% off

Applies to thermal-links, intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions. May be applicable to thermal-links for use under other than indoor conditions, provided that the climatic and other circumstances in the immediate surroundings of such thermal-links are comparable with those in this standard.

  • Standard
    77 pages
    English and French language
    sale 15% off
  • Standard
    154 pages
    English and French language
    sale 15% off
  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    5 pages
    English and French language
    sale 15% off
  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English and French language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English and French language
    sale 15% off

This part of IEC 60127 relates to universal modular fuse-links (UMF) for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment, and component parts thereof, normally intended to be used indoors. It does not apply to fuse-links for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. This standard applies in addition to the requirements of IEC 60127-1.

  • Standard
    59 pages
    English and French language
    sale 15% off
  • Standard
    61 pages
    English and French language
    sale 15% off

Related to changes in Clauses 7.2, 9.1 and Tables 3 and 4

  • Standard
    9 pages
    English and French language
    sale 15% off

This standard relates to miniature fuses for the protection of electric appliances, electronic equipment and component parts thereof normally intended to be used indoors. It relates to general requirements applicable to all fuses, which fall under the category of miniature fuses. Specific details covering each major subdivision are given in subsequent parts.

  • Standard
    1 page
    English and French language
    sale 15% off
  • Standard
    53 pages
    English and French language
    sale 15% off
  • Standard
    53 pages
    English and French language
    sale 15% off

Relates to miniature fuses for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors, as specified in IEC 60127-2, 60127-3 and 60127-4. It relates to fuse-holders for miniature fuse-links according to IEC 60127-6. The object of this guide is to introduce the user to the important properties of miniature fuse-links and fuse-holders for miniature fuses-links and to give some guidance on applying them.

  • Standard
    31 pages
    English and French language
    sale 15% off

Applies to thermal-links, intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions. May be applicable to thermal-links for use under other than indoor conditions, provided that the climatic and other circum- stances in the immediate surroundings of such thermal-links are comparable with those in this standard.

  • Standard
    43 pages
    English and French language
    sale 15% off

This standard relates to special requirements applicable to sub-miniature fuse-links adapted to printed circuits and used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors. This standard also applies to the requirements of IEC 60127-1.

  • Standard
    1 page
    English and French language
    sale 15% off
  • Standard
    10 pages
    English and French language
    sale 15% off

Relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions of 5 mm x 20 mm and 6.3 mm x 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. The contents of the corrigendum of March 1990 have been included in this copy.

  • Standard
    1 page
    English and French language
    sale 15% off

IEC/PAS 60127-8:2014(E) relates to fuse resistors with particular overcurrent protection rated up to 500 V a.c. and/or 500 V d.c. for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors. It does not apply to fuse resistors with particular overcurrent protection for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. The object of this PAS is:
- to establish uniform requirements for fuse resistors with particular overcurrent protection so as to protect appliances or parts of appliances in the most suitable way;
- to define the performance of the fuse resistors with particular overcurrent protection, so as to give guidance to manufacturers of electrical appliances and electronic equipment and to ensure replacement of fuse resistors with particular overcurrent protection by those of similar dimensions and characteristics;
- to define methods of testing. This PAS applies in addition to the requirements of IEC 60127-1. Keywords: resistors with particular overcurrent protection, protection of electric appliances, electronic equipment and component parts

  • Technical specification
    25 pages
    English language
    sale 15% off