CORRECTED VERSION 2026-11
IEC 61000-6-3:2026 is applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.21) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial locations are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. Equipment that has a radio function (3.1.20) are included in the scope of this document. However, the emission requirements in this document are not intended to be applicable to the intentional transmissions from these radio transmitters, their harmonics and their out of band emissions. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document.
The objectives of this document are:
- to establish requirements that provide an adequate level of protection of radio reception in the frequency range 9 kHz to 400 GHz;
- to establish requirements that provide an adequate level of protection against conducted and radiated electromagnetic disturbances emitted by equipment in the scope of this document;
- to support the reproducibility of measurement and the repeatability of results.
NOTE 1 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example, where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed.
NOTE 2 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 3 The requirements in this document are more stringent or equivalent to the requirements specified in IEC 61000-6-4 and IEC 61000-6-8.
This fourth edition cancels and replaces the third edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of magnetic field emission requirements, including the measurement of WPT function;
b) the extension of low-voltage AC mains power requirements to cover the range 9 kHz to 150 kHz;
c) products with a radio function have been added to the scope;
d) limits in a FAR for rack mounted equipment have been added.

  • Standard
    70 pages
    English language
    sale 15% off
  • Standard
    142 pages
    English language
    sale 15% off
  • Standard
    76 pages
    French language
    sale 15% off
  • Standard
    146 pages
    English and French language
    sale 15% off
  • Standard
    146 pages
    English and French language
    sale 15% off

IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alternative method for measuring conducted emissions on DC ports;
b) limits and requirements applicable only to equipment intended to be used in residential locations;
c) more stringent limits for DC power ports.
NOTE 1 Safety considerations are not covered by this document.
NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.

  • Standard
    52 pages
    English and French language
    sale 15% off

IEC 61000-6-8: 2020 is a generic EMC emission standard and is applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use in commercial and light-industrial (see 3.1.3) locations. This document applies to equipment that satisfy the following restrictions of use:
is defined as professional equipment (see 3.1.13),
is professionally installed and maintained (see 3.1.14 and Clause 6),
is not intended to be used in residential locations (see 3.1.16).
IEC 61000-6-3 applies to electrical and electronic equipment intended for use at commercial and light-industrial locations that do not satisfy these restrictions. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt, the requirements in IEC 61000-6-3 apply. Emission requirements within the frequency range 0 Hz to 400 GHz are covered. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU.
NOTE 1 Safety considerations are not covered by this document.
NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, employ special mitigation measures to reduce any impact.
NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 4 Equipment which complies with IEC 61000-6-3 are suitable for use within these defined locations.

  • Standard
    64 pages
    English and French language
    sale 15% off

IEC 61000-6-4:2018 for emission requirements applies to electrical and electronic equipment intended for use within the environment existing at industrial (see 3.1.12) locations. This document does not apply to equipment that fall within the scope of IEC 61000-6-3. The environments encompassed by this document cover both indoor and outdoor locations. Emission requirements in the frequency range 9 kHz to 400 GHz are covered in this document and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. No measurement needs to be performed at frequencies where no requirement is specified. These requirements are considered essential to provide an adequate level of protection to radio services. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the environments included within this document. Requirements are specified for each port considered. This generic EMC emission standard is to be used where no applicable product or product-family EMC emission standard is available. This third edition cancels and replaces the second edition published in 2006 and Amendment 1:2010 This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) possible future requirements on DC ports;
b) possible future radiated polarity specific emission limits within a FAR;
c) the definition of which average detector is used for emission measurements at frequencies above 1GHz and that results using a peak detector are acceptable for all measurements;
d) the definition of different EUT test arrangements.
Keywords: emission standard for industrial environments

  • Standard
    81 pages
    English language
    sale 15% off
  • Standard
    52 pages
    English and French language
    sale 15% off

CISPR/TR 31:2012 covers the rationale behind the actual database covering the characteristics of radio services. The objective of the database is to register those characteristics which are relevant for derivation and specification of limits for disturbance emissions from electric and/or electronic equipment, systems and installations. Committees responsible for generic and/or product emission EMC standards should use this information together with CISPR 23. This second edition includes the replacement of CISPR 23 as reference standard for the determination of limits by CISPR 16-4-4:2007 on "model for the calculation of limits for the protection of radio services".

  • Technical report
    20 pages
    English and French language
    sale 15% off

This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in industrial environments as described below. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists. This standard applies to a apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus, which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. Industrial locations are in addition characterised by the existence of one or more of the following examples: - industrial, scientific and medical (ISM) apparatus; - heavy inductive or capacitive loads that are frequently switched; - high currents and associated magnetic fields. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in industrial locations do not exceed a level that could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements. Requirements are specified for each port considered.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off
  • Standard
    23 pages
    English and French language
    sale 15% off
  • Standard
    37 pages
    English and French language
    sale 15% off

This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source, which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations that are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations that are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in residential, commercial and light-industrial locations do not exceed a level which could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements. Requirements are specified for each port considered.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off
  • Standard
    27 pages
    English and French language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off

Frequently Asked Questions

WG 1 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Maintenance of the generic emission standards" and is responsible for: Maintenance of the generic emission standards This committee has published 1302 standards.

WG 1 develops IEC standards in the area of Information technology. The scope of work includes: Maintenance of the generic emission standards Currently, there are 1302 published standards from this technical committee.

The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.

A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.