This document specifies requirements for the ice plug technique with liquid nitrogen or dry ice as refrigerant (cryogenic medium) on metal pipes of nuclear power plants. The freezing liquid can be water or water mixture (e.g. boric acid mixture). This document specifies technical requirements of ice plug generation, formation judgment and removal, measures before, during and after ice plugging and requirements for personnel and non-destructive testing. The application of the ice plug isolation technique is principally not allowed on cladded pipes or pipes with internal coatings. The application for pressure test is not in the scope of this document and will be qualified separately.

  • Standard
    15 pages
    English language
    sale 15% off
  • Draft
    15 pages
    English language
    sale 15% off

This document specifies the basic requirements of thermal insulation design of reactor coolant system (RCS) equipment and piping. Among thermal insulation of various RCS equipment and piping, the following two kinds of thermal insulations are described in detailed based on common design logic and requirements: — thermal insulation of reactor pressure vessel (RPV); — thermal insulation of RCS piping and other equipment. This document is valid for two types of thermal insulation: — metallic thermal insulation; — non-metallic thermal insulation. This document mainly applies to nuclear power plants with pressurized water reactor (PWR). For other reactor types, this document can be taken as reference.

  • Standard
    24 pages
    English language
    sale 15% off
  • Draft
    24 pages
    English language
    sale 15% off

This document gives guidelines for pre-service inspection (PSI) and in-service inspections (ISI) by eddy current tests on non-ferromagnetic steam generator heating tubes of light water reactors, whereby the test is carried out using mechanised test equipment outwards from the tube inner side. An in-service eddy current test of steam generator heating tube plugs as a component of the primary circuit is not an object of this document. Owing to the different embodiments of steam generator heating tube plugs, the use of specially adapted test systems to be qualified is necessary. Test systems for the localisation of inhomogeneities (surface) and requirements for test personnel, test devices, the preparation of test and device systems, the implementation of the testing as well as the recording are defined. NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the nuclear safety standards. It is recommended that the technical specifications are based on experience on U-tube bends with even bend radius (similar to the S/KWU design). To test other kind of tube bends (e.g. U-tube bends with two 90° bends) further qualifications will be provided.

  • Standard
    19 pages
    English language
    sale 15% off
  • Draft
    19 pages
    English language
    sale 15% off

This document gives guidelines for pre-service inspection (PSI) and in-service inspections (ISI) for reactor coolant circuit components of light water reactors and their installations as direct or remote visual testing in the form of a — general visual testing (overview), or — selective visual testing (specific properties). This document is also applicable to other components of nuclear installations. The requirements in this document focuses on remote (mechanized) visual testing, but also specifies global requirements for direct visual testing. For specific requirements for direct visual testing of welds see ISO 17637. This document is not applicable to tests in respect to the general state that are carried out in conjunction with pressure and leak tests and regular plant inspections. This document specifies test methods that allow deviations from the expected state to be recognised, requirements for the equipment technology and test personnel, the preparation and performance of the testing as well as the recording. NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the applicable national nuclear safety standards.

  • Standard
    14 pages
    English language
    sale 15% off
  • Draft
    14 pages
    English language
    sale 15% off

This document gives guidelines for pre-service inspections (PSI) and in-service inspections (ISI) of the surfaces using the magnetic particle testing and penetrant testing on components of the reactor coolant circuit of light water reactors. This document is also applicable to other components of nuclear installations. Test systems for the localisation of surface inhomogeneities and requirements for test personnel, test devices, test media, accessories as well as optical auxiliaries, the preparation and implementation of the test as well as the recording are defined. NOTE 1 Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications are defined in the applicable national nuclear safety standards. NOTE 2 In general, this document is in accordance with ISO 3452 and ISO 9934 series. This document provides details to be considered in the standard test procedure (see Annex A).

  • Standard
    15 pages
    English language
    sale 15% off
  • Draft
    15 pages
    English language
    sale 15% off

This document gives guidelines for in-service system pressure tests of the reactor coolant circuit of light water reactors. This document specifies the test technique, the requirements for measuring equipment and additional devices, the preparation and performance of the test as well as the recording and documentation, for the purpose to ensure the reliability and comparability of tests. NOTE Data on (test) pressure, (test) temperature, scope of testing, rates of change of pressure and temperature, test schedule and inspection intervals can be obtained from the applicable national nuclear codes.

  • Standard
    8 pages
    English language
    sale 15% off
  • Draft
    8 pages
    English language
    sale 15% off

This document gives guidelines for pre-service-inspections (PSI) and in-service inspections (ISI) with mechanized ultrasonic test (UT) devices on components of the reactor coolant circuit of light water reactors. This document is also applicable on other components of nuclear installations. Mechanized ultrasonic inspections are carried out in order to enable an evaluation in case of — fault indications (e.g. on austenitic weld seams or complex geometry), — indications due to geometry (e.g. in case of root concavity), — complex geometries (e.g. fitting weld seams), or — if a reduction in the radiation exposure of the test personnel can be attained in this way. Ultrasonic test methods are defined for the validation of discontinuities (volume or surface open), requirements for the ultrasonic test equipment, for the preparation of test and device systems, for the implementation of the test and for the recording. This document is applicable for the detection of indications by UT using normal-beam probes and angle-beam probes both in contact technique. It is to be used for UT examination on ferritic and austenitic welds and base material as search techniques and for comparison with acceptance criteria by the national referencing nuclear safety standards. Immersion technique and techniques for sizing are not in the scope of this document and are independent qualified. NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the applicable national nuclear safety standards. Unless otherwise specified in national nuclear safety standards the minimum requirements of this document are applicable. This document does not define: — extent of examination and scanning plans; — acceptance criteria; — UT techniques for dissimilar metal welds and for sizing (have to be qualified separately); — immersion techniques; — time-of-flight diffraction technique (TOFD). It is recommended that UT examinations are nearly related to the component, the type and size of defects to be considered and are reviewed in specific national inspection qualifications.

  • Standard
    33 pages
    English language
    sale 15% off
  • Draft
    33 pages
    English language
    sale 15% off

The document provides: — guidelines for determining the thermal effects to consider on fire barriers inside a given room; — guidelines for determining the global performance of the fire barriers based on standard test characterization; — guidelines for assessing the need for additional tests to verify the robustness of the solution. Requirements of applicable standards, numerical tools validation and verification (V&V), and the expected qualification of fire resistance laboratories are detailed. The limitations of the method's applicability and scope are discussed. The purpose and justification of this document is to describe a new methodology for the verification of the efficiency of fire barriers, which is initially based on a standardized fire resistance test. The significance of this work relates to the fact that the present methodology will enhance the level of safety by providing more realism to hazards analysis in combination with standardized test data. It completes the standard ISO-fire rating required for justifying the performance. The most relevant benefit of this method concerns the determination of the global performance of a barrier in a fire of extended duration compared to the classification given by the ISO-fire rating.

  • Standard
    68 pages
    English language
    sale 15% off
  • Standard
    70 pages
    French language
    sale 15% off

ISO 18229:2018 defines the essential technical requirements that are addressed in the process of design and construction of Generation IV (GEN IV) nuclear reactors. It does not address operation, maintenance and in-service inspection of reactors. Six reactor concepts are considered for GEN IV: the sodium fast reactor, the lead fast reactor, the gas fast reactor, the very high temperature reactor, the supercritical water reactor and the molten salt reactor. Annex A details the main characteristics for the different concepts. The scope of application of this document is limited to mechanical components related to nuclear safety and to the prevention of the release of radioactive materials ? that are considered to be important in terms of nuclear safety and operability, ? that play a role in ensuring leaktightness, partitioning, guiding, securing and supporting, and ? that contain and/or are in contact with fluids (such as vessels, pumps, valves, pipes, bellows, box structures, heat exchangers, handling and driving mechanisms).