ISO/TC 23/SC 18 - Irrigation and drainage equipment and systems
Matériels et réseaux d'irrigation et de drainage
General Information
This document specifies the general requirements and test methods for manually operated and hydraulically operated plastics valves intended for use in agricultural irrigation systems. It is applicable to manually operated and hydraulically operated plastics valves (as indicated in Table A.2) of nominal sizes DN 8 (1/4") to DN 200 (8").
- Standard13 pagesEnglish languagesale 15% off
- Draft13 pagesEnglish languagesale 15% off
This document specifies requirements for the components and method of installation of pressurized irrigation system control heads, referred to hereinafter as irrigation control heads, with a nominal size of up to and including 200 mm (nominal size of an irrigation control head or nominal size of a component). This document is applicable only to the above-ground components of irrigation control heads for sprinkler irrigation and micro-irrigation (mini-sprinklers, drip irrigation, etc.). It is applicable to the basic irrigation control head, on which other irrigation control and command components (electrical, electronic and hydraulic) can be assembled, but does not deal with these additional components. This document is not applicable to systems and/or components that can be required to prevent the water from freezing in the irrigation control head, such as dry-barrel hydrants or other types of hydrants. This document does not specify construction or operating requirements for the individual components that make up the irrigation control head. These requirements are specified in the relevant standards for each component.
- Standard16 pagesEnglish languagesale 15% off
- Draft16 pagesEnglish languagesale 15% off
This document specifies the construction, operational requirements and test methods for water-driven chemical injector pumps (hereinafter, water-driven injector pumps). These water-driven injector pumps are used to inject chemicals into irrigation systems. The chemicals include liquid fertilizers and solutions of fertilizers and other soluble agricultural chemicals such as acids and pesticides. This document is applicable to water-driven injector pumps intended to operate at water temperatures of up to 50 °C and with the types and concentrations of chemicals routinely applied in irrigation. It does not cover the function of backflow prevention devices, nor is it applicable to water-driven devices for injecting chemicals into an irrigation system operating on the basis of the Venturi principle.
- Standard12 pagesEnglish languagesale 15% off
- Draft12 pagesEnglish languagesale 15% off
This document specifies requirements and test methods for reinforced and non-reinforced thermoplastic collapsible hoses, intended to be used as main and sub-main supply lines for the conveyance and distribution of water for irrigation, at water temperatures up to 50 °C. PVC layflat hoses are excluded from this document. It is applicable to irrigation hoses with nominal diameters between 40 mm and 500 mm and working pressures between 0,3 bar (30 kPa) and 6 bar (600 kPa). This document is applicable to two types of hose configurations, with or without outlet connections (see Clause 4).
- Standard6 pagesEnglish languagesale 15% off
- Draft6 pagesEnglish languagesale 15% off
This document specifies construction and performance requirements and test methods for direct-acting pressure-regulating valves (hereinafter "pressure regulators") intended for operation in irrigation systems, with water at temperatures not exceeding 60 °C, which can contain fertilizers and chemicals of types and in concentrations commonly used in agricultural irrigation. This document applies to pressure regulators in nominal sizes up to and including 100 mm (4 in).
- Standard15 pagesEnglish languagesale 15% off
- Draft15 pagesEnglish languagesale 15% off
This document specifies the design and operational requirements of irrigation sprinklers and their test methods. The term sprinkler is used in this document in a broad generic sense and it means to cover a wide variety of products as classified by ISO 15886‑1. This document applies to rotating sprinklers. This document is applicable to sprinklers intended for installation on a pipe lateral and for operation with irrigation water.
- Standard11 pagesEnglish languagesale 15% off
- Draft11 pagesEnglish languagesale 15% off
This document specifies the conditions and methods used for testing and characterizing the water distribution patterns of irrigation sprinklers. The term sprinkler is used in this document in a broad generic sense and is meant to cover a wide variety of products. The specific performance measurements addressed include distribution uniformity, wetted radius, and water jet trajectory height. This document applies to all irrigation sprinkler classifications for which those three performance measurements are required to verify the design objectives as defined by the manufacturer. This document deals both with indoor and outdoor tests and with radial and full grid tests. It is organized so as to deal with conditions common to all tests first and then with conditions unique to indoor testing only and finally with conditions unique to outdoor testing only. For any given sprinkler, a wide range of nozzle configurations, operating conditions, and adjustments generate at least a theoretical need for a correspondingly large number of tests. Testing agencies and manufacturers can use interpolation techniques to reduce the number of actual test runs provided accuracy standards are still being met. This document does not address the specific performance testing required for sprinklers intended for use in frost protection. This document does not address the topic of drop spectrum measurement and characterization and the related questions of soil compaction, spray drift, evaporative losses, etc., all of which can be considerations in the design of sprinkler irrigation systems. This document is used for evaluating irrigation coverage of sprinklers that are identical and arranged in a fixed repeating geometric pattern. This document does not apply to moving systems. This document applies to part-circle sprinklers provided that the testing agency can satisfy questions of potential anomalies in performance parameters. NOTE Annex A addresses the procedures for the characterization of sprinkler pattern uniformity. Annex B addresses testing part-circle sprinklers.
- Standard21 pagesEnglish languagesale 15% off
- Draft21 pagesEnglish languagesale 15% off
This document specifies the conditions and methods for testing the durability of rotating sprinklers for irrigation. The term sprinkler is used here in a broad generic sense and is meant to cover a wide variety of products as classified in ISO 15886-1, which applies to all irrigation sprinkler classifications having both static parts and moving parts during operation, as defined by the manufacturer. For any given sprinkler, a wide range of nozzle configurations, operating conditions, and adjustments generates at least a theoretical need for a correspondingly large number of tests. Testing agencies and manufacturers can use interpolation techniques to reduce the number of actual test runs, provided accuracy standards are still being met.
- Standard10 pagesEnglish languagesale 15% off
This document gives guidelines for the design, selection, installation and use of the equipment required to establish basic test facilities for irrigation equipment evaluation. It provides the information sufficient to complement the detailed procedures included in ISO 7714, ISO 8026, ISO 9261, ISO 9635 (all parts), ISO 9644, ISO 9911, ISO 10522, ISO 15886 and ISO 16399 for the testing of agricultural irrigation system components, specifically emitters, sprinklers, valves, sprayers and water meters.
- Technical report22 pagesEnglish languagesale 15% off
This document applies to manually-activated valves only. This document specifies a test method for determining the pressure loss in agricultural irrigation valves under steady-state conditions when water flows through them. The scope and accuracy of the valve performance specifications presented will assist agricultural irrigation system designers in comparing pressure losses through various types of valves. The measurement of pressure losses provides a means for determining the relationship between pressure loss and flow rate through the valve. This document also describes the method of reporting pertinent test data. No attempt is made to define product use, design or applications. The test method is suitable for valves with equal inlet and outlet nominal sizes.
- Standard19 pagesEnglish languagesale 15% off
This document specifies construction requirements and test methods for pressurized granulated media filters, hereinafter referred to as media filters, intended for operation in agricultural irrigation systems. It is applicable to both manual cleaning media filters and automatic self-cleaning media filters, used as single unit or in batteries (two or more units working in parallel). This document covers the operation and performance of a media filter, together with all related valves, back flushing mechanism, underdrains, manifolds and other related accessories necessary for the operation of the filter. This document is applicable to three configurations of a filter. a) An empty filter vessel (tank) housing. b) A filter vessel filled with media filter material(s), complete with valves, connections, air release and/or other accessories. This configuration, when connected to and controlled by a flushing control device, is a complete operating single filter unit, usually positioned as a part of a filtration station. c) A filtration station, called "filter battery". Annex A provides information on types of irrigation media filters. Annex B provides information on granulated media.
- Standard16 pagesEnglish languagesale 15% off
This document specifies general requirements and test methods for volumetric valves able to automatically deliver preset quantities of water. It is applicable to valves actuated by pipeline pressure and flow alone, and which do not need any other, external, source of energy. NOTE Volumetric valves are typically required to operate correctly with different qualities of irrigation water at a variety of flow rates and at temperatures between 5 °C and 50 °C.
- Standard13 pagesEnglish languagesale 15% off
ISO 13460-1:2015 specifies the required properties and test methods for plastics saddles for assembly on polyethylene (hereinafter "PE") pressure pipes used in above-ground and underground irrigation systems conveying water at temperatures not exceeding 50 °C.
- Standard9 pagesEnglish languagesale 15% off
ISO 18471:2015 a test method for the verification of filtration grade of filters intended for operation in agricultural irrigation systems. It is intended to be used for verifying the filter manufacturer's declaration about the filtration grade of a specific filter. This test method uses a Clogging Capacity Meter (CCM) device to compare the filtration grade of the filter under test against the filtration grade of a test filtration screen. NOTE This test method may also be used by a filter manufacturer to determine the filtration grade.
- Standard7 pagesEnglish languagesale 15% off
ISO 13693-2:2015 specifies the construction and performance requirement and test methods for metal-bodied chemigation valves with water at temperatures not exceeding 50 °C, which might contain fertilizers and chemicals of the types and concentration used in agriculture. The valve is designed to prohibit backflow caused by either back pressure or back siphonage. It is not designed for use in potable water systems. It is not to be confused with other forms of backflow prevention devices including pressure vacuum breakers, double check valves, reduced pressure zone valves, or goose neck loops. ISO 13693-2:2015 specifies the minimum design, construction, and performance testing requirements for the chemigation valve assembly. The assembly consists of the following components: ? a valve body into which a spring-loaded check valve is mounted with a resilient disk cover on the sealing surface; a combination air release/vacuum relief valve located upstream of the check valve; a low pressure drain valve located upstream of the check valve; an inspection port located so as to permit visual and manual inspection of the valve working components.
- Standard8 pagesEnglish languagesale 15% off
ISO 9635-5:2014 specifies construction and performance requirements and test methods for control valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically-operated control irrigation valves of DN 15 (1/2 inch) diameter or greater, designed to operate in any position, from fully open to fully closed. The valves can either be directly operated (i.e. the force applied via a spring or diaphragm to the obturator), or pilot-operated (i.e. the force is applied through an adjustable pilot valve via a diaphragm). These valves can also function as check valves.
- Standard13 pagesEnglish languagesale 15% off
ISO 9635-3:2014 specifies construction and performance requirements and test methods for check valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated check irrigation valves of DN 15 diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard7 pagesEnglish languagesale 15% off
ISO 9635-4:2014 specifies construction and performance requirements and test methods for air valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated air irrigation valves of DN 15 diameter or greater, designed to be directly operated, i.e. the force is applied to the obturator by the float, either directly or via a mechanical linkage. The valves can be operated by a force applied through an adjustable pilot valve.
- Standard14 pagesEnglish languagesale 15% off
ISO 9635-1:2014 specifies construction and performance requirements and test methods for valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to irrigation valves of 8 mm diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard23 pagesEnglish languagesale 15% off
ISO 9635-2:2014 specifies construction and performance requirements and test methods for isolating valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to isolating irrigation valves of DN 8 in diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard15 pagesEnglish languagesale 15% off
ISO 16399:2014 applies to water meters intended for irrigation use (herein after referred to as water meters), regardless of the water quality used for this purpose, and specifies the requirements and certification procedures for water meters, irrespective of the design technologies used to meter the actual volume of cold water or heated water flowing through a fully charged closed conduit. These water meters incorporate devices which indicate the integrated volume. ISO 16399:2014 also applies to water meters based on electrical or electronic principles and to water meters based on mechanical principles, incorporating electronic devices used to meter the actual volume flow of cold water. It provides metrological requirements for electronic ancillary devices when they are subject to metrological control. As a rule, the ancillary devices are optional. However national or international regulations make some ancillary devices mandatory in relation to the utilization of the water meter.
- Standard47 pagesEnglish languagesale 15% off
- Standard47 pagesEnglish languagesale 15% off
ISO 9912-2:2013 specifies general construction requirements and test methods for strainer filters and disc filters intended for operation in agricultural irrigation systems. It does not cover the aspects of filtration ability, efficiency and capacity (like quality of filtered water or time of operation before a filter becomes entirely clogged), nor does it deal with structural requirements or tests of automatic flushing mechanism filters that are covered by ISO 9912-3.
- Standard10 pagesEnglish languagesale 15% off
ISO 9912-3:2013 specifies general construction requirements and test methods for automatic flushing strainer-type filters and disc filters intended for operation in agricultural irrigation systems. It does not cover the aspects of filtration ability, efficiency and capacity (like quality of filtered water or time of operation before filter becomes entirely clogged).
- Standard8 pagesEnglish languagesale 15% off
ISO 13693-1:2013 specifies the general requirements and test methods for small plastics-bodied valves used for chemigation, intended for operation in irrigation pipe systems which may contain fertilizers and chemicals of the type and concentration used in agriculture. It is applicable to controllable safety devices (also known as backflow preventers) with a reduced pressure zone (RPZ), intended to prevent backflow by back-siphonage or backpressure of irrigation water into an upstream potable water distribution system, whenever the pressure in the latter is lower than that in the system located downstream. It is applicable to such devices of nominal size up to and including DN 50 (2"), with a nominal pressure of PN10, that are capable of working without modification or adjustment at any pressure up to 1 MPa (10 bar), with any pressure variation up to 1 MPa (10 bar), and in permanent duty at temperatures up to 45 °C and for 1 h at 65 °C.
- Standard23 pagesEnglish languagesale 15% off
- Standard24 pagesFrench languagesale 15% off
ISO/TR 15155-2:2012 is intended to provide guidance on the operation of basic test facilities for irrigation equipment evaluation. Its purpose is to provide information sufficient to implement the detailed procedures included in ISO 7714, ISO 8026, ISO 9261, ISO 9635-1 to 5, ISO 9644, ISO 9911 and ISO 10522 and ISO 15886-3 for the testing of agricultural irrigation system components, specifically emitters, sprinklers and valves. The intent is that the structure of tISO/TR 15155-2 can be modified to be used as the operating manual of a test facility established to test the components referred to in these International Standards.
- Technical report33 pagesEnglish languagesale 15% off
ISO 15886-1:2012 defines terms related to irrigation sprinklers and specifies the classification of sprinklers according to the following categories: physical factors; characteristics of the water spray; the mechanism for operation and water distribution; the mechanism for sealing; the intended use; additional functions incorporated into the sprinkler. The scope is intentionally broad to cover the widest possible range of sprinkler construction, performance, and intended-use alternatives.
- Standard16 pagesEnglish languagesale 15% off
ISO 15081:2011 establishes graphical symbols for use on drawings and diagrams relating to the installation of pressurized agricultural irrigation systems.
- Standard10 pagesEnglish languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
ISO 8026:2009 specifies the general requirements and test methods for irrigation sprayers. It is applicable to sprayers intended for installation on a pipe lateral and for operation with irrigation water.
- Standard18 pagesEnglish languagesale 15% off
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 11545:2009 specifies an in-field method for determining the uniformity of water distribution in the field from centre-pivot and moving lateral irrigation machines equipped with sprayer or sprinkler nozzles. The calculation of the coefficient of uniformity is also specified. It is applicable to agricultural irrigation machines for which the water application device is more than 1,5 m above the soil surface and for which the water distribution from successive devices overlaps. It is not applicable to the evaluation of centre-pivot irrigation machines equipped with various corner arm application devices.
- Standard16 pagesEnglish languagesale 15% off
- Standard17 pagesFrench languagesale 15% off
ISO 16149:2006 specifies the requirements for unplasticized polyvinyl chloride (PVC) piping, used to supply and to distribute low-pressure irrigation water through gates. It is applicable to PVC piping with diameters of from 50 mm to 315 mm, operating at low pressures and exposed to sunlight.
- Standard8 pagesEnglish languagesale 15% off
ISO 9912-1:2004 defines terms used in relation to filters intended for agricultural micro-irrigation systems -- in particular, pressurized systems -- and provides a means of classifying those filters according to filtration method, structure, operating principle and function. It does not deal with classification according to the type of water intended to be filtered; nor does it apply to the classification of filters for potable or domestic water use.
- Standard8 pagesEnglish languagesale 15% off
ISO 9261:2004 gives mechanical and functional requirements for agricultural irrigation emitters and emitting pipes, and, where applicable, their fittings, and provides methods for testing conformity with such requirements. It also specifies the data to be supplied by the manufacturer to permit correct information, installation and operation in the field. It is applicable to emitters, emitting and dripping (trickling) pipes, hoses, including collapsible hoses ("tapes") and tubing of which the emitting units form an integral part, to emitters and emitting units with or without pressure regulation and with flow rates not exceeding 24 l/h per outlet (except during flushing), as well as to fittings dedicated to the connection of emitting pipes, hoses and tubing. It is not applicable to porous pipe (pipe that is porous along its entire length), nor does it cover the performance of pipes as regards clogging.
- Standard16 pagesEnglish languagesale 15% off
- Standard17 pagesFrench languagesale 15% off
ISO 8224-1:2002 specifies the operational characteristics of, and laboratory and field test methods for, traveller irrigation machines. It includes user-oriented technical information for presentation in the manufacturer's accompanying product literature, laboratory test procedures for evaluating the uniformity of water application on an irrigated strip by a machine operating within a specified range of conditions and for determining the maximum travelling rates the drive mechanism is able to achieve in response to specified operating conditions, and field test procedures for determining the uniformity of water application on a given irrigated strip under local conditions prevailing in the field at time of testing. It is applicable only to traveller irrigation machine types, and not to other types such as centre-pivot or lateral irrigation machines.
- Standard36 pagesEnglish languagesale 15% off
- Standard40 pagesFrench languagesale 15% off
ISO 15873 specifies the construction of, and operational requirements and test methods for, differential pressure Venturi-type liquid additive injectors -- a component of systems used to inject chemicals, including liquid fertilizers, liquid solutions of water-soluble fertilizers, acids, caustics, pesticides, herbicides and other liquid additives, into irrigation systems. ISO 15873 does not specify means of preventing backflow of liquid additives to potable water supply systems, the assembly of such means, near to the Venturi injector, being covered by water protection regulations.
- Standard7 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
Contains minimum requirements and test methods for aluminium tubes intended for use in agricultural irrigation systems at temperatures not exceeding 50 °C. Does not apply to tubes with integrated couplings.
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
Provides detailed information for the application of electrical apparatus to electrically driven or controlled agricultural irrigation machines. Covers all electrical equipment necessary from the point of connection of electric power to the machine.Applies to electrical equipment for use on circuits operating at voltages from 30 V to 600 V. Intended to improve the degree of personal safety in operation and application of products and materials.
- Standard9 pagesEnglish languagesale 15% off
This part applies to such hose and couplings used with stationary hose-coiling, mobile hose-laying or hose-coiling, and mobile hose-dragging irrigation machines used in agriculture and forestry. It specifies test methods for specific physical properties and accelerated durability tests. Eleven test procedures are given.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
This report deals with systems based on hydraulic devices using only the energy that can be obtained from the water in the irrigation system; it gives main definitions and a classification of these systems. Applies to control systems, in which the control of water application is achieved by means of water quantity measurement. Semi-automatic control systems are used for one irrigation cycle, each subsequent cycle requires a further manual operation to preset the required water quantities. Some figures illustrate the meaning of the description.
- Technical report7 pagesEnglish languagesale 15% off
- Technical report7 pagesFrench languagesale 15% off
- Technical report7 pagesFrench languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
ISO 16438:2012 specifies requirements and test methods for reinforced and non-reinforced thermoplastic collapsible hoses, which are intended to be used as main and sub-main supply lines for the conveyance and distribution of water for irrigation at water temperatures up to 50 °C. It is applicable to irrigation hoses with nominal diameters between 40 mm and 500 mm and working pressures between 0,3 bar (0,03 MPa) and 6 bar (0,6 MPa). ISO 16438:2012 is applicable to two types of hose configurations: distributor hose (with outlet connections) and plain hose (without outlet connections).
- Standard5 pagesEnglish languagesale 15% off
ISO 15886-3:2012 specifies the conditions and methods used for testing and characterizing the water distribution patterns of irrigation sprinklers. The term sprinkler is used in a broad generic sense and is meant to cover a wide variety of products as classified by ISO 15886-1. The specific performance measurements addressed include distribution uniformity, wetted radius, and water jet trajectory height. This standard applies to all irrigation sprinkler classifications for which these three performance measurements are required to verify the design objectives as defined by the manufacturer. ISO 15886-3:2012 deals both with indoor and outdoor tests and with radial and full grid tests. It is organized so as to deal with conditions common to all tests first and then with conditions unique to indoor testing only and finally with conditions unique to outdoor testing only. For any given sprinkler, a wide range of nozzle configurations, operating conditions, and adjustments generate at least a theoretical need for a correspondingly large number of tests. Testing agencies and manufacturers may use interpolation techniques to reduce the number of actual test runs provided accuracy standards are still being met. ISO 15886-3:2012 does not address the specific performance testing required for sprinklers intended for use in frost protection. It also does not address the topic of drop spectrum measurement and characterization and the related questions of soil compaction, spray drift, evaporative losses, etc., all of which can be considerations in the design of sprinkler irrigation systems. To apply ISO 15886-3:2012 for evaluating irrigation coverage, all sprinklers must be identical and arranged in a fixed repeating geometric pattern. ISO 15886-3:2012 does not apply to moving systems. ISO 15886-3:2012 applies to part-circle sprinklers provided that the testing agency can satisfy questions of potential anomalies in performance parameters. One annex addresses the procedures for the characterization of sprinkler pattern uniformity; another addresses testing part-circle sprinklers.
- Standard18 pagesEnglish languagesale 15% off
ISO 7714:2008 specifies general requirements and test methods for volumetric valves able to automatically deliver preset quantities of water. It is applicable to valves actuated by pipeline pressure and flow alone, and which do not need any other, external, source of energy.
- Standard13 pagesEnglish languagesale 15% off
ISO 13457:2008 specifies the construction, operational requirements and test methods for water‑driven chemical injector pumps, used to inject chemicals into irrigation systems. The chemicals include liquid fertilizers and solutions of fertilizers and other soluble agricultural chemicals such as acids and pesticides. ISO 13457:2008 is applicable to those pumps intended to operate at water temperatures of up to 50 °C and with the types and concentrations of chemicals routinely applied in irrigation. It does not cover the function of backflow prevention devices, nor is it applicable to water-driven devices for injecting chemicals into an irrigation system operating on the basis of the Venturi principle.
- Standard12 pagesEnglish languagesale 15% off
ISO 9644:2008 specifies a test method for determining the pressure loss in agricultural irrigation valves under steady-state conditions when water flows through them. The scope and accuracy of the valve performance specifications presented will assist agricultural irrigation system designers in comparing pressure losses through various types of valves.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard11 pagesEnglish languagesale 15% off
ISO 9635-3:2006 specifies construction and performance requirements and test methods for check valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated check irrigation valves of DN 15 (1/2 inch) diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard7 pagesEnglish languagesale 15% off
ISO 9635-5:2006 specifies construction and performance requirements and test methods for control valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated control irrigation valves of DN 15 (1/2 inch) diameter or greater, designed to operate in any position, from fully open to fully closed. The valves can either be directly operated (i.e. the force applied via a spring or diaphragm to the obturator), or pilot-operated (i.e. the force is applied through an adjustable pilot valve via a diaphragm).
- Standard11 pagesEnglish languagesale 15% off
ISO 9635-2:2006 specifies construction and performance requirements and test methods for isolating valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated isolating irrigation valves of DN 8 (1/4 inch) diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard15 pagesEnglish languagesale 15% off
ISO 9635-1:2006 specifies construction and performance requirements and test methods for valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to irrigation valves of 15 mm diameter or greater, designed to operate in the fully open and fully closed positions, but which can also operate for extended time periods in any intermediate position.
- Standard24 pagesEnglish languagesale 15% off
ISO 9635-4:2006 specifies construction and performance requirements and test methods for air valves, intended for operation in irrigation systems with water at temperatures not exceeding 60 °C, which can contain fertilizers and other chemicals of the types and concentrations used in agriculture. It is applicable to hydraulically operated air irrigation valves of DN 15 (1/2 inch) diameter or greater, designed to be directly operated, i.e. the force is applied to the obturator by the float, either directly or via a mechanical linkage. The valves can be operated by a force applied through an adjustable pilot valve.
- Standard11 pagesEnglish languagesale 15% off