Standard Test Method for Determination of Benzene-Soluble Particulate Matter in Workplace Atmospheres

SIGNIFICANCE AND USE
5.1 This test method provides a means of evaluating exposures to benzene-soluble particulate matter in a concentration range that can be related to occupational exposures.
SCOPE
1.1 This test method describes the sampling and gravimetric determination of benzene-soluble particulate matter that has become airborne as a result of certain industrial processes. This test method can be used to determine the total weight of benzene-soluble materials and to provide a sample that may be used for specific and detailed analyses of the soluble components.  
1.2 The limit of detection is 0.05 mg/m3 by sampling a 1 m3 volume of air.
Note 1: Other volatile organic solvents have been used for this determination and whereas a less toxic solvent for this analysis might be desirable, the substitution of a solvent other than benzene is unwise at this time. A tremendous volume of environmental sampling data based on benzene-soluble determinations has been accumulated over many years in several industries.2 Some of the determinations have been used in epidemiological studies. Furthermore, the use of benzene is specified in existing United States federal standards.3 As a result, it appears imprudent to use a different solvent until the qualitative and quantitative relationship of analyses derived from benzene and a substitute solvent is established. With proper care, benzene can be safely used in the laboratory.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
28-Feb-2022
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D4600-22 - Standard Test Method for Determination of Benzene-Soluble Particulate Matter in Workplace Atmospheres
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D4600-22 - Standard Test Method for Determination of Benzene-Soluble Particulate Matter in Workplace Atmospheres
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D4600 − 22
Standard Test Method for
Determination of Benzene-Soluble Particulate Matter in
1
Workplace Atmospheres
This standard is issued under the fixed designation D4600; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical
1.1 Thistestmethoddescribesthesamplingandgravimetric
Barriers to Trade (TBT) Committee.
determination of benzene-soluble particulate matter that has
becomeairborneasaresultofcertainindustrialprocesses.This
2. Referenced Documents
test method can be used to determine the total weight of
4
2.1 ASTM Standards:
benzene-soluble materials and to provide a sample that may be
D1356 Terminology Relating to Sampling and Analysis of
used for specific and detailed analyses of the soluble compo-
Atmospheres
nents.
D1357 Practice for Planning the Sampling of the Ambient
3 3
1.2 The limit of detection is 0.05 mg/m by sampling a 1 m
Atmosphere
volume of air.
D4840 Guide for Sample Chain-of-Custody Procedures
NOTE 1—Other volatile organic solvents have been used for this
D5337 Practice for Flow RateAdjustment of Personal Sam-
determination and whereas a less toxic solvent for this analysis might be
pling Pumps
desirable, the substitution of a solvent other than benzene is unwise at this
D8358 GuideforAssessmentandInclusionofWallDeposits
time. A tremendous volume of environmental sampling data based on
in the Analysis of Single-Stage Samplers for Airborne
benzene-soluble determinations has been accumulated over many years in
2
several industries. Some of the determinations have been used in Particulate Matter
5
epidemiological studies. Furthermore, the use of benzene is specified in
2.2 Other Documents:
3
existing United States federal standards. As a result, it appears imprudent
ISO/IEC 17025 General requirements for the competence of
to use a different solvent until the qualitative and quantitative relationship
testing and calibration laboratories
of analyses derived from benzene and a substitute solvent is established.
With proper care, benzene can be safely used in the laboratory.
3. Terminology
1.3 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this 3.1 Definitions: For definitions of terms used in this test
standard. method, refer to Terminology D1356.
1.4 This standard does not purport to address all of the
4. Summary of Test Method
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 4.1 By the use of a personal sampling pump, air is pulled
throughaglass-fiberfilterheldinasamplingcassette.Thefilter
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use. is extracted ultrasonically with benzene. After filtration, an
aliquot of the total extract is evaporated to dryness and the
1.5 This international standard was developed in accor-
dance with internationally recognized principles on standard- residue weighed.
ization established in the Decision on Principles for the
5. Significance and Use
5.1 This test method provides a means of evaluating expo-
1
This test method is under the jurisdiction of ASTM Committee D22 on Air sures to benzene-soluble particulate matter in a concentration
Quality and is the direct responsibility of Subcommittee D22.04 on Workplace Air
range that can be related to occupational exposures.
Quality.
Current edition approved March 1, 2022. Published June 2022. Originally
approved in 1986. Last previous edition approved in 2016 as D4600 – 95 (2016).
4
DOI: 10.1520/D4600-22. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
2
“Benzene-Soluble Compounds in Air, P&CAM 217,” NIOSH Manual of contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Analytical Methods, 2nd Ed., DHEW (NIOSH) Pub. No. 77-157-A, National Standards volume information, refer to the standard’s Document Summary page on
Institute of Occupational Safety and Health, Cincinnati, OH 1977. the ASTM website.
3 5
“Appendix B—Industrial Hygiene and Medical Surveillance Guidelines,” Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
20CFR 1910.1029 Coke Oven Emissions. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor D
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D4600 − 95 (Reapproved 2016) D4600 − 22
Standard Test Method for
Determination of Benzene-Soluble Particulate Matter in
1
Workplace Atmospheres
This standard is issued under the fixed designation D4600; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method describes the sampling and gravimetric determination of benzene-soluble particulate matter that has become
airborne as a result of certain industrial processes. This test method can be used to determine the total weight of benzene-soluble
materials and to provide a sample that may be used for specific and detailed analyses of the soluble components.
3 3
1.2 The limit of detection is 0.05 mg/m by sampling a 1-m1 m volume of air.
NOTE 1—Other volatile organic solvents have been used for this determination and whereas a less toxic solvent for this analysis might be desirable, the
substitution of a solvent other than benzene is unwise at this time. A tremendous volume of environmental sampling data based on benzene-soluble
2
determinations has been accumulated over many years in several industries. Some of the determinations have been used in epidemiological studies.
3
Furthermore, the use of benzene is specified in existing United States federal standards. As a result, it appears imprudent to use a different solvent until
the qualitative and quantitative relationship of analyses derived from benzene and a substitute solvent is established. With proper care, benzene can be
safely used in the laboratory.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
4
2.1 ASTM Standards:
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D1357 Practice for Planning the Sampling of the Ambient Atmosphere
D4840 Guide for Sample Chain-of-Custody Procedures
D5337 Practice for Flow Rate Adjustment of Personal Sampling Pumps
1
This test method is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.
Current edition approved May 15, 2016March 1, 2022. Published May 2016June 2022. Originally approved in 1986. Last previous edition approved in 20102016 as
D4600 – 95 (2010).(2016). DOI: 10.1520/D4600-95R16.10.1520/D4600-22.
2
“Benzene-Soluble Compounds in Air, P&CAM 217,” NIOSH Manual of Analytical Methods, 2nd Ed., DHEW (NIOSH) Pub. No. 77-157-A, National Institute of
Occupational Safety and Health, Cincinnati, OH 1977.
3
“Appendix B—Industrial Hygiene and Medical Surveillance Guidelines,” 20CFR 1910.1029 Coke Oven Emissions.
4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D4600 − 22
D8358 Guide for Assessment and Inclusion of Wall Deposits in the Analysis of Single-Stage Samplers for Airborne Particulate
Matter
5
2.2 Other Documents:
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories
3. Terminology
3.1 Definitions: For definitions of terms used in this test method, refer to Terminology D1356.
4. Summary of Test Method
4.1 By the use of a personal sampling pump, air is pulled through a glass-fiber filter held in a sampling cassette. The filter is
extracted ultrasonically with benzene. After filtration, an aliquot of the total extract i
...

Questions, Comments and Discussion