Standard Specification for Perfluoroalkoxy (PFA)-Fluoropolymer Tubing

ABSTRACT
This specification covers tubing produced from PFA fluoropolymer resins which are cited in another specification. This document specifies tubing dimensional tolerances, tensile properties and related electrical properties as noted in the appropriate tables when tested in accordance with the methods cited. Different tests shall be performed in order to determine the following properties of resins: inside diameter, wall thickness, specific gravity, tensile strength, elongation, and dimensional stability.
SCOPE
1.1 This specification covers tubing produced from PFA Fluoropolymer resins which are cited in Specification D3307. This document specifies tubing dimensional tolerances, tensile properties and related electrical properties as noted in the appropriate tables when tested in accordance with the methods cited in this specification. This specification is for virgin material only and does not address recycled material, as it is not appropriate for PFA tubing.
Note 1: Abbreviations are in accordance with Terminology D1600.
Note 2: There is no known ISO equivalent to this standard.  
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.  
1.3 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Sep-2019
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D6867-19 - Standard Specification for Perfluoroalkoxy (PFA)-Fluoropolymer Tubing
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM D6867-19 - Standard Specification for Perfluoroalkoxy (PFA)-Fluoropolymer Tubing
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D6867 −19
Standard Specification for
1
Perfluoroalkoxy (PFA)-Fluoropolymer Tubing
This standard is issued under the fixed designation D6867; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D1600 Terminology forAbbreviatedTerms Relating to Plas-
tics
1.1 This specification covers tubing produced from PFA
D1675 Test Methods for Polytetrafluoroethylene Tubing
Fluoropolymer resins which are cited in Specification D3307.
D3307 Specification for Perfluoroalkoxy (PFA) Resin Mold-
This document specifies tubing dimensional tolerances, tensile
ing and Extrusion Materials
properties and related electrical properties as noted in the
D4894 Specification for Polytetrafluoroethylene (PTFE)
appropriate tables when tested in accordance with the methods
Granular Molding and Ram Extrusion Materials
cited in this specification. This specification is for virgin
IEEE/ASTM SI 10 Standard for Use of the International
material only and does not address recycled material, as it is
3
System of Units (SI): The Modern Metric System
not appropriate for PFA tubing.
NOTE 1—Abbreviations are in accordance with Terminology D1600.
3. Terminology
NOTE 2—There is no known ISO equivalent to this standard.
3.1 Definitions:
1.2 The values stated in SI units are to be regarded as
3.1.1 Definitions are in accordance with Terminology D883
standard. The values given in parentheses are for information
unless otherwise specified.
only.
3.1.2 lot, n—one continuous production run or a uniform
1.3 The following safety hazards caveat pertains only to the
blend of two or more production runs of one size sheet or
test methods portion, Section 7, of this specification. This
molded basic shape.
standard does not purport to address all of the safety concerns,
if any, associated with its use. It is the responsibility of the user 4. Physical Requirements
of this standard to establish appropriate safety, health, and
4.1 The tubing shall be made of PFA-fluoropolymer resin
environmental practices and determine the applicability of
meeting the requirements of Specification D3307.
regulatory limitations prior to use.
4.2 Theinsidediameterandwallthicknessandtolerancesof
1.4 This international standard was developed in accor-
the tubing shall be as shown in Table 1, when determined in
dance with internationally recognized principles on standard-
accordance with 7.1.3.1 and 7.1.3.2.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
4.3 The specific gravity of the tubing shall be between 2.12
mendations issued by the World Trade Organization Technical
and 2.17 inclusive when determined in accordance with 7.1.4.
Barriers to Trade (TBT) Committee.
4.4 The tubing shall have a minimum tensile strength of
10.0 MPa (1500 psi) and a minimum elongation of 200 %
2. Referenced Documents
when determined in accordance with 7.1.5.
2
2.1 ASTM Standards:
4.5 The tubing shall remain free from cracks and exhibit no
D618 Practice for Conditioning Plastics for Testing
splitting when tested for dimensional stability in accordance
D792 Test Methods for Density and Specific Gravity (Rela-
with 7.1.6.
tive Density) of Plastics by Displacement
D883 Terminology Relating to Plastics
5. Sampling
5.1 Sampling shall be statistically adequate to satisfy the
1
This specification is under the jurisdiction of ASTM Committee D20 on
requirements of 8.2.
Plastics and is the direct responsibility of Subcommittee D20.15 on Thermoplastic
Materials.
6. Number of Tests
Current edition approved Oct. 1, 2019. Published October 2019. Originally
6.1 One set of test specimens as described in Section 7 shall
approved in 2003. Last previous edition approved in 2014 as D6867 - 03(2014).
DOI: 10.1520/D6867-19.
be considered sufficient for testing each batch. The average
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from ASTM International Headquarters, 100 Barr Harbor Drive, PO
the ASTM website. Box C700, West Conshohocken, PA 19428–2959.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6867 − 19
TABLE 1 Dimen
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6867 − 03 (Reapproved 2014) D6867 − 19
Standard Specification for
1
Perfluoroalkoxy (PFA)-Fluoropolymer Tubing
This standard is issued under the fixed designation D6867; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Scope*
1.1 This specification covers tubing produced from PFA Fluoropolymer resins which are cited in Specification D3307. This
document specifies tubing dimensional tolerances, tensile properties and related electrical properties as noted in the appropriate
tables when tested in accordance with the methods cited in this specification. This specification is for virgin material only and does
not address recycled material, as it is not appropriate for PFA tubing.
NOTE 1—Abbreviations are in accordance with Terminology D1600.
NOTE 2—There is no known ISO equivalent to this standard.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.3 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification. This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the applicability of
regulatory requirementslimitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D792 Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1675 Test Methods for Polytetrafluoroethylene Tubing
D3307 Specification for Perfluoroalkoxy (PFA) Resin Molding and Extrusion Materials
D4894 Specification for Polytetrafluoroethylene (PTFE) Granular Molding and Ram Extrusion Materials
3
IEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): The Modern Metric System
3. Terminology
3.1 Definitions:
3.1.1 Definitions are in accordance with Terminology D883 unless otherwise specified.
3.1.2 lot, n—one continuous production run or a uniform blend of two or more production runs of one size sheet or molded basic
shape.
4. Physical Requirements
4.1 The tubing shall be made of PFA-fluoropolymer resin meeting the requirements of Specification D3307.
4.2 The inside diameter and wall thickness and tolerances of the tubing shall be as shown in Table 1, when determined in
accordance with 7.1.3.1 and 7.1.3.2.
1
This specification is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materials.
Current edition approved Oct. 1, 2014Oct. 1, 2019. Published October 2014October 2019. Originally approved in 2003. Last previous edition approved in 20092014 as
D6867 - 03(2009).(2014). DOI: 10.1520/D6867-03R14.10.1520/D6867-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from ASTM International Headquarters, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428–2959.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6867 − 19
TABLE 1 Dimensions and Tolerances for PFA-Fluorocarbon Tubing-Dimensions, mm (in.)
Inside Diameter Wall Thickness
Nominal Inside Diameter, Inside Diameter Tolerance, Nominal Thickness, Thickness Tolerance,
mm (in.) mm (in.) mm (in.) mm (in.)
0 to 0.25 (0.000 to 0.010) ±0.03 (0.001) 0 to 0.13 (0.000 to 0.005) ±0.030 (0.001)
0.26 to 0.50 (0.011 to 0.020) ±0.05 (0.002) 0.14 to 0.30 (0.006 to 0.012) ±0.050 (0.002)
0.51
...