ASTM C1005-18
(Specification)Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements
Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements
ABSTRACT
This specification covers the minimum requirements for scales, balances, reference masses, and glass graduates used in the physical testing of hydraulic cements. Requirements for analytical reference masses and balances are not included in this specification. Reference masses for use in the methods of physical testing of hydraulic cement and related and similar materials shall conform at least to the requirements of Class 6 reference masses given in this specification. The maintenance tolerances given in this specification for Class 6 reference masses are to be considered acceptance tolerances for purposes of this specification and the maintenance tolerances twice these values. Requirements for scales, balances, and glass graduates shall conform at least to the requirements for capacity, precision and accuracy, readability, and sensitivity.
SCOPE
1.1 This specification covers the minimum requirements for scales, balances, reference masses, and glass graduates used in the physical testing of hydraulic cements.
1.2 Requirements for analytical reference masses and balances are not included in this specification, but are to be found in Test Methods C114. The use of restrictive terminology, classes, ranges, and so forth has been intentionally avoided to allow the use of this specification by other standards-writing bodies with similar requirements for reference masses and devices for determining mass, if desired.
1.3 These requirements are not sufficiently descriptive to be used as the sole specifications for the purchase of reference masses or devices for determining mass without amplification.
1.4 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in IEEE/ASTM SI–10, of measurement made in other units.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1005 −18
Standard Specification for
Reference Masses and Devices for Determining Mass and
Volume for Use in the Physical Testing of Hydraulic
1
Cements
This standard is issued under the fixed designation C1005; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* E617 Specification for Laboratory Weights and Precision
Mass Standards
1.1 This specification covers the minimum requirements for
IEEE/ASTM SI–10 Standard for Use of the International
scales, balances, reference masses, and glass graduates used in
System of Units (SI): The Modern Metric System
the physical testing of hydraulic cements.
1.2 Requirements for analytical reference masses and bal-
3. Terminology
ances are not included in this specification, but are to be found
3.1 Definitions:
in Test Methods C114. The use of restrictive terminology,
3.1.1 accuracy, n—degree of conformity of the indication of
classes, ranges, and so forth has been intentionally avoided to
a device for determining mass to the true value of an applied
allow the use of this specification by other standards-writing
mass.
bodies with similar requirements for reference masses and
devices for determining mass, if desired.
3.1.2 balance, n—a device for determining mass that com-
pares a mass with standard masses.
1.3 These requirements are not sufficiently descriptive to be
used as the sole specifications for the purchase of reference
3.1.3 precision, n—reproducibility of the readings of a
masses or devices for determining mass without amplification.
device for determining mass when a given test mass is applied.
1.4 Values in SI units shall be obtained by measurement in
3.1.4 range of mass determination, n—the range of indica-
SI units or by appropriate conversion, using the Rules for
tions of a device from the minimum test load plus any aids or
Conversion and Rounding given in IEEE/ASTM SI–10,of
containers on the load-receiving elements to the maximum test
measurement made in other units.
load with the same aids or containers, as specified by the
particular method of test being used.
1.5 This international standard was developed in accor-
dance with internationally recognized principles on standard-
3.1.5 readability, n—the smallest fraction of a division to
ization established in the Decision on Principles for the
which the index scale of a device for determining mass can be
Development of International Standards, Guides and Recom-
read with ease either by estimation or by use of a vernier.
mendations issued by the World Trade Organization Technical
3.1.6 reference mass, n—a piece of material of known
Barriers to Trade (TBT) Committee.
specified mass for use in comparing or measuring the mass of
other masses (see Note 1).
2. Referenced Documents
3.1.6.1 Discussion—The definition of “reference mass” was
2
2.1 ASTM Standards:
formerly incorrectly designated “weight;” weight is a force
C114 Test Methods for Chemical Analysis of Hydraulic
(see IEEE/ASTM SI–10).
Cement
3.1.7 scale, n—a device for determining mass having a
load-receiving element and an index scale (possibly in combi-
nation with the use of internal masses or proportional masses),
1
This specification is under the jurisdiction of ASTM Committee C01 on
almost always calibrated to indicate mass; generally of lesser
Cement and is the direct responsibility of Subcommittee C01.95 on Coordination of
accuracy than a balance.
Standards.
Current edition approved May 1, 2018. Published June 2018. Originally
3.1.8 sensitivity, n—the minimum change of applied mass
approved in 1983. Last previous edition approved in 2017 as C1005 – 17. DOI:
requiredtoperceptiblymovetheindicatingelementofadevice
10.1520/C1005-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or for determining mass.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3.1.9 sensitivity requirement, n—the minimum change in
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. position of rest of the indicating element of a device for
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1005−18
determining mass in response to a specified change of mass 4.2 Amass used strictly as a mass, whose actual value need
load on the load-receiving element. not be known, need not meet the requirements of 4.1 (see Note
2).
3.1.10 test load, n—the mass to be determined in a single
determina
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1005 − 17 C1005 − 18
Standard Specification for
Reference Masses and Devices for Determining Mass and
Volume for Use in the Physical Testing of Hydraulic
1
Cements
This standard is issued under the fixed designation C1005; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers the minimum requirements for scales, balances, reference masses, and glass graduates used in the
physical testing of hydraulic cements.
1.2 Requirements for analytical reference masses and balances are not included in this specification, but are to be found in Test
Methods C114. The use of restrictive terminology, classes, ranges, and so forth has been intentionally avoided to allow the use of
this specification by other standards-writing bodies with similar requirements for reference masses and devices for determining
mass, if desired.
1.3 These requirements are not sufficiently descriptive to be used as the sole specifications for the purchase of reference masses
or devices for determining mass without amplification.
1.4 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion
and Rounding given in IEEE/ASTM SI–10, of measurement made in other units.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C114 Test Methods for Chemical Analysis of Hydraulic Cement
E617 Specification for Laboratory Weights and Precision Mass Standards
IEEE/ASTM SI–10 Standard for Use of the International System of Units (SI): The Modern Metric System
3. Terminology
3.1 Definitions:
3.1.1 accuracy, n—degree of conformity of the indication of a device for determining mass to the true value of an applied mass.
3.1.2 balance, n—a device for determining mass that compares a mass with standard masses.
3.1.3 precision, n—reproducibility of the readings of a device for determining mass when a given test mass is applied.
3.1.4 range of mass determination, n—the range of indications of a device from the minimum test load plus any aids or
containers on the load-receiving elements to the maximum test load with the same aids or containers, as specified by the particular
method of test being used.
3.1.5 readability, n—the smallest fraction of a division to which the index scale of a device for determining mass can be read
with ease either by estimation or by use of a vernier.
3.1.6 reference mass, n—a piece of material of known specified mass for use in comparing or measuring the mass of other
masses (See(see Note 1).
1
This specification is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.95 on Coordination of Standards.
Current edition approved March 15, 2017May 1, 2018. Published March 2017June 2018. Originally approved in 1983. Last previous edition approved in 20102017 as
C1005 – 10.C1005 – 17. DOI: 10.1520/C1005-17.10.1520/C1005-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1005 − 18
3.1.6.1 Discussion—
The definition of “reference mass” was formerly incorrectly designated “weight;” weight is a force (See(see IEEE/ASTM SI–10).
3.1.7 scale, n—a device for determining mass having a load-receiving element and an index scale (possibly in combination with
the use of internal masses or proportional masses), almost always calibrated to indicate mass; generally of lesser accuracy than a
balance.
3.1.8 sensitivity, n—the minimum change of applied mass required to perceptibly move the indicating element of a device for
determining mass.
3.1.9 sensitivity requirement, n—the minimum
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.