Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications

SCOPE
1.1 This specification covers cast iron soil pipe and fittings for use in gravity flow applications. It establishes standards covering material, principal dimensions, and dimensional tolerances for hubless cast iron soil pipe and fittings. These pipe and fittings are not intended for pressure applications, as the selection of the proper size for sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage.
1.2 This specification covers pipe and fittings of the following patterns and applies to any other patterns that conform with the requirements given herein.1.2.1 Lengths: FiguresEDP Identification Numbers for Hubless Pipe110 ft (3.0 m) in sizes 1 ½ , 2, 3, 4, 5, 6, 8, 10, 12, and 15 inch.1, 2Method of Specifying Fittings3
1.2.2Fittings: Quarter Bend4Quarter Bend, Reducing5Quarter Bend, With Side Opening6Quarter Bend, With Heel Opening7Quarter Bend, Tapped8Quarter Bend, Double9Quarter Bend, Long10Short Sweep11Long Sweep12Long Sweep, Reducing13Fifth Bend14Sixth Bend15Eighth Bend16Eighth Bend Long17Sixteenth Bend18Sanitary Tee19Sanitary Tee With Side Opening20Sanitary Tee With 2 in. Side Opening R or L/R and L21Sanitary Tee, New Orleans Special With Side Opening22Sanitary Tee With 45 Side Openings and New Orleans23Sanitary Special Tee Tapped24Sanitary Tapped Tee, Horizontal Twin25Sanitary Tapped Tee, Double Vertical26Y Branch27Y Branch, Double28Y Branch, Upright29Upright Y Wide Center Florida Special30Y Branch, Combination 1/8 Bend 31Y Branch, Combination 1/8 Bend Double32Sanitary Cross33Sanitary Cross With Side Opening34Sanitary Cross, New Orleans, With Side Openings35Sanitary Cross, New Orleans, With 45 Special andRegular Side Openings 36Sanitary Cross, Tapped37Test Tee38Tapped, Extension Piece39Increaser-Reducer40Increaser-Reducer, Short41Tapped Adapter42Blind Plug43Iron Body Cleanout-Tapped44P Trap 45P Trap, Long46P Trap, Long-Tapped47P Trap, Deep Seal48P Trap, Reducing49P Trap, With Primer50P Trap, With Tapped Inlet51Hub Adapter52Tapped Inlet, Double53Modified Combination Wye and 1/8 Bend, Double54Modified Combination Wye and 1/8 Bend, Double, Extended55Regular or Extended Left or Right Regular or ExtendedDouble56Regular or Extended Left or Right Regular or ExtendedDouble57Two-Way Cleanout58Twin Cleanout59Closet Bend, Regular and Reducing60Closet Flange61Tapping Bosses62
1.3 The values stated in inch-pound units shall be regarded as the standard. The values given in parentheses shall be for information only.
Note 1—The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
09-Jul-2003
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM A888-03 - Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications
English language
50 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: A 888 – 03
Standard Specification for
Hubless Cast Iron Soil Pipe and Fittings for Sanitary and
1
Storm Drain, Waste, and Vent Piping Applications
This standard is issued under the fixed designation A 888; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
Quarter Bend, Double Fig. 10
Quarter Bend, Long Fig. 11
1.1 This specification covers hubless cast iron soil pipe and
Short Sweep Fig. 12
fittings for use in gravity flow applications. It establishes
Long Sweep Fig. 13
Long Sweep, Reducing Fig. 14
standards covering material, manufacture, mechanical and
Fifth Bend Fig. 15
chemical properties, dimensions, coating, test methods, inspec-
Sixth Bend Fig. 16
tion,certificationandproductmarkingforhublesscastironsoil
Eighth Bend Fig. 17
Eighth Bend Long Fig. 18
pipe and fittings. These pipe and fittings are intended for
Sixteenth Bend Fig. 19
non-pressure applications, as the selection of the proper size
Sanitary Tee Fig. 20
for sanitary drain, waste, vent, and storm drain systems allows Sanitary Tee With Side Opening Fig. 21
Sanitary Tee With 2 in. Side Opening R or L/R and L Fig. 22
free air space for gravity drainage.
Sanitary Tee, New Orleans Special With Side Opening Fig. 23
1.2 The EDP/ASA numbers indicated in this section repre-
Sanitary Tee With 45° Side Openings and New Orleans Fig. 24
sent a Uniform Industry Code adopted by theAmerican Supply Sanitary Special Tee Tapped Fig. 25
Sanitary Tapped Tee, Horizontal Twin Fig. 26
Association (ASA). A group designation prefix, 022, is as-
Sanitary Tapped Tee, Double Vertical Fig. 27
signed to hubless products, followed by the four-digit identi-
Y Branch Fig. 28
fication assigned to individual items and a check digit. This Y Branch, Double Fig. 29
Y Branch, Upright Fig. 30
system has been instituted to facilitate EDP control through
Upright Y Wide Center Florida Special Fig. 31
distribution channels, and be used universally in ordering and 1
Y Branch, Combination ⁄8 Bend Fig. 32
1
specifying product items. Those items with no EDP numbers Y Branch, Combination ⁄8 Bend Double Fig. 33
Sanitary Cross Fig. 34
are either new, special or transitory and will be assigned
Sanitary Cross With Side Opening Fig. 35
numbers on subsequent prints of this specification.
Sanitary Cross, New Orleans, With Side Openings Fig. 36
1.3 This specification covers pipe and fittings of the follow- Sanitary Cross, New Orleans, With 45° Special and Fig. 37
Regular Side Openings
ing patterns and applies to any other patterns that conform with
Sanitary Cross, Tapped Fig. 38
2
the applicable requirements given herein.
Test Tee Fig. 39
Tapped, Extension Piece Fig. 40
1.3.1 Lengths:
Increaser-Reducer Fig. 41
Figures
Increaser-Reducer, Short Fig. 42
EDP/ASA Identification Numbers Fig. 1
Tapped Adapter Fig. 43
for Hubless Pipe
Blind Plug Fig. 44
10 ft (3.0 m) in sizes and 5 ft. (1.5 m) Fig. 1, Fig. 2
Iron Body Cleanout-Tapped Fig. 45
1
1 ⁄2 ,2,3,4,5,6,8,
P Trap Fig. 46
10, 12, and 15 inch.
P Trap, Long Fig. 47
Method of Specifying Fittings Fig. 3
P Trap, Long-Tapped Fig. 48
Sample Test Bar Fig. 4
P Trap, Deep Seal Fig. 49
P Trap, Reducing Fig. 50
1.3.2 Fittings:
P Trap, With Primer Fig. 51
Quarter Bend Fig. 5
P Trap, With Tapped Inlet Fig. 52
Quarter Bend, Reducing Fig. 6
Hub Adapter Fig. 53
Quarter Bend, With Side Opening Fig. 7
Tapped Inlet, Double Fig. 54
1
Quarter Bend, With Heel Opening Fig. 8
Modified Combination Wye and ⁄8 Bend, Double Fig. 55
1
Quarter Bend, Tapped Fig. 9
Modified Combination Wye and ⁄8 Bend, Double, Ex- Fig. 56
tended
Regular or Extended Left or Right Regular or Extended Fig. 57
Double
1
Regular or Extended Left or Right Regular or Extended Fig. 58
This specification is under the jurisdiction of ASTM Committee A04 on Iron
Double
CastingsandisunderthedirectresponsibilityofSubcommitteeA04.12onPipesand
Two-Way Cleanout Fig. 59
Tubes.
Twin Cleanout Fig. 60
Current edition approved July 10, 2003. Published September 2003. Originally
e1
Closet Bend, Regular and Reducing Fig. 61
approved in 1990. Last previous edition approved in 1998 as A 888 – 98 .
2 Closet Flange Fig. 62
Reprinted with permission from Cast Iron Soil Pipe Institute.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
A888–03
CF—Carlson fitting
Tapping Bosses Fig. 63
CLO—closet
1.4 The values stated in inch-pound un
...

Questions, Comments and Discussion