Standard Specification for Linoleum Floor Tile

ABSTRACT
This specification covers floor tiles made of a homogeneous mixture of linoleum cement binder calendered or pressed onto a fibrous or suitable backing for use in commercial, light commercial and residential buildings based on serviceability characteristics. General information and performance characteristics, which determine serviceability and recommended use, are included in this document. The floor coverings shall be of the following types: Type I—linoleum floor tile with fibrous backing; Type II—linoleum floor tile with special backing; Type III—linoleum floor tile without backing; and Type IV—static dissipative linoleum floor tile with or without backing. Materials shall be tested and the individual grades shall conform to specified values of physical properties such as wear surface, size, thickness, and squareness; performance requirements such as residual indentation, static load resistance, flexibility, dimensional stability, resistance to chemicals, resistance to heat, resistance to light, and static dissipation.
SCOPE
1.1 This specification covers floor tiles made of a homogeneous mixture of linoleum cement binder calendered or pressed onto a fibrous or suitable backing. This specification also covers linoleum floor tile without backing.
1.2 Four types of linoleum floor tile are covered. The floor covering is intended for use in commercial, light commercial, and residential buildings based on serviceability characteristics. General information and performance characteristics, which determine serviceability and recommended use, are included in this document.
1.3 The following safety hazards caveat pertains only to the test methods portion, Sections 7 and 8, of this specification.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
1.4 The values stated in inch-pound units are to be regarded as the standard; the values in parentheses are provided for information only.

General Information

Status
Historical
Publication Date
30-Apr-2007
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2195-07 - Standard Specification for Linoleum Floor Tile
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F2195 −07
StandardSpecification for
1
Linoleum Floor Tile
This standard is issued under the fixed designation F2195; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope F925 Test Method for Resistance to Chemicals of Resilient
Flooring
1.1 This specification covers floor tiles made of a homoge-
F970 Test Method for Static Load Limit
neousmixtureoflinoleumcementbindercalenderedorpressed
F1514 TestMethodforMeasuringHeatStabilityofResilient
onto a fibrous or suitable backing. This specification also
Flooring by Color Change
covers linoleum floor tile without backing.
F1515 Test Method for Measuring Light Stability of Resil-
1.2 Four types of linoleum floor tile are covered. The floor
ient Flooring by Color Change
covering is intended for use in commercial, light commercial,
F2055 Test Method for Size and Squareness of Resilient
and residential buildings based on serviceability characteris-
Floor Tile by Dial Gage Method
tics. General information and performance characteristics,
2.2 Other Standards:
which determine serviceability and recommended use, are
ANSI/ASQC Z1.4 Sampling Procedures and Tables for In-
3
included in this document.
spection by Attributes
1.3 The following safety hazards caveat pertains only to the EN 433 Determination of Residual Indentation after Static
4
Loading
test methods portion, Sections 7 and 8, of this specification.
EN 669 Determination of the Dimensional Changes of Tiles
1.4 This standard does not purport to address all of the
4
Caused by Atmospheric Humidity Changes
safety concerns, if any, associated with its use. It is the
EN 670 Identification and Composition of Linoleum—
responsibility of the user of this standard to establish appro-
4
Determination of Cement and Ash Residue
priate safety and health practices and determine the applica-
bility of regulatory requirements prior to use.
3. Terminology
1.5 The values stated in inch-pound units are to be regarded
3.1 Definitions:
as the standard; the values in parentheses are provided for
3.1.1 For definitions, refer to Terminology F141.
information only.
4. Classification
2. Referenced Documents
4.1 The floor coverings shall be of the following types:
2
2.1 ASTM Standards:
4.1.1 Type I—Linoleum floor tile with fibrous backing.
F137 Test Method for Flexibility of Resilient Flooring Ma-
4.1.2 Type II—Linoleum floor tile with special backing.
terials with Cylindrical Mandrel Apparatus
4.1.3 Type III—Linoleum floor tile without backing.
F141 Terminology Relating to Resilient Floor Coverings
4.1.4 Type IV—Static dissipative linoleum floor tile with or
F150 Test Method for Electrical Resistance of Conductive
without backing.
and Static Dissipative Resilient Flooring
F386 Test Method for Thickness of Resilient Flooring Ma- NOTE 1—If any of the above structures incorporate a stabilizing
inner-layer mat or fabric between the top wear-layer and the back of the
terials Having Flat Surfaces
structure,theflooringtypewillincludethehyphenatedsuffixof“-IL.”(for
F410 Test Method for Wear Layer Thickness of Resilient
example,Type II-IL, a linoleum floor tile with a special backing including
Floor Coverings by Optical Measurement
an inner-layer mat or fabric).
5. Ordering Information
1
This specification is under the jurisdiction of ASTM Committee F06 on
5.1 Linoleum floor tile shall be ordered by type, thickness,
Resilient Floor Coverings and is the direct responsibility of Subcommittee F06.80
and other characteristics important to the purchaser for the
on Specifications.
Current edition approved May 1, 2007. Published June 2007. Originally
intended use.
´1
approved in 2002. Last previous edition aprpoved in 2003 as F 2195–03 . DOI:
10.1520/F2195-07.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM 4th Floor, New York, NY 10036.
4
Standards volume information, refer to the standard’s Document Summary page on Available from CEN European Committee for Standardization—Central Sec-
the ASTM website. retariat: rue de Stassart, 36 B-1050 Brussels.
Copyright ©ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2195−07
5.1.1 Title, number, and date of this specification, 7. Physical Properties
5.1.2 Type and pattern number,
7.1 Wear Surface—The thickness of the wear surface shall
5.1.3 Quantity in square feet, square meters, pieces or
be determined in accordance with Te
...