ASTM D822/D822M-13(2018)
(Practice)Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings
Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings
SIGNIFICANCE AND USE
4.1 The ability of a paint or coating to resist deterioration of its physical and optical properties caused by exposure to light, heat, and water can be very significant for many applications. This practice is intended to induce property changes associated with end-use conditions, including the effects of sunlight, moisture, and heat. The exposure used in this practice is not intended to simulate the deterioration caused by localized weather phenomena such as atmospheric pollution, biological attack, and saltwater exposure.
4.2 Cautions—Variation in results may be expected when different operating conditions are used. Therefore, no reference to the use of this practice shall be made unless accompanied by a report prepared according to Section 10 that describes the specific operating conditions used. Refer to Practice G151 for detailed information on the caveats applicable to use of results obtained according to this practice.
Note 1: Additional information on sources of variability and on strategies for addressing variability in the design, execution, and data analysis of laboratory accelerated exposure tests is found in Guide G141.
4.2.1 The spectral power distribution of light from an open-flame carbon-arc is significantly different from that produced in light and water exposure devices using other carbon-arc configurations or other light sources. The type and rate of degradation and the performance rankings produced by exposures to filtered open-flame carbon-arcs can be much different from those produced by exposures to other types of laboratory light sources.
4.2.2 Interlaboratory comparisons are valid only when all laboratories use the same type of carbon-arc, filters, and exposure conditions.
4.3 Reproducibility of test results between laboratories has been shown to be good when the stability of materials is evaluated in terms of performance ranking compared to other materials or to a control.4,5 Therefore, exposure of a similar material of known...
SCOPE
1.1 This practice covers the selection of test conditions for accelerated exposure testing of coatings and related products in filtered open-flame carbon-arc devices conducted according to Practices G151 and G152. This practice also covers the preparation of test specimens, the test conditions suited for coatings, and the evaluation of test results. Table 1 describes commonly used test conditions.
1.2 This practice does not cover enclosed carbon-arc exposures of paints and related coatings, which is described in Practice D5031/D5031M. Another procedure for exposing these products is covered by Practice D3361/D3361M, in which the specimens are subjected to radiation from an unfiltered open-flame carbon arc that produces shorter wavelengths and higher levels of short wavelength radiation than filtered open-flame or enclosed carbon arcs.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D822/D822M − 13 (Reapproved 2018)
Standard Practice for
Filtered Open-Flame Carbon-Arc Exposures of Paint and
Related Coatings
This standard is issued under the fixed designation D822/D822M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope 2. Referenced Documents
1.1 This practice covers the selection of test conditions for 2.1 ASTM Standards:
acceleratedexposuretestingofcoatingsandrelatedproductsin D358 Specification for Wood to Be Used as Panels in
filtered open-flame carbon-arc devices conducted according to Weathering Tests of Coatings (Withdrawn 2014)
Practices G151 and G152. This practice also covers the D523 Test Method for Specular Gloss
preparation of test specimens, the test conditions suited for D609 Practice for Preparation of Cold-Rolled Steel Panels
coatings, and the evaluation of test results. Table 1 describes for Testing Paint, Varnish, Conversion Coatings, and
commonly used test conditions. Related Coating Products
D610 Practice for Evaluating Degree of Rusting on Painted
1.2 This practice does not cover enclosed carbon-arc expo-
Steel Surfaces
sures of paints and related coatings, which is described in
D659 Method for Evaluating Degree of Chalking of Exterior
Practice D5031/D5031M. Another procedure for exposing
Paints (Withdrawn 1990)
these products is covered by Practice D3361/D3361M,in
D660 Test Method for Evaluating Degree of Checking of
which the specimens are subjected to radiation from an
Exterior Paints
unfiltered open-flame carbon arc that produces shorter wave-
D662 Test Method for Evaluating Degree of Erosion of
lengths and higher levels of short wavelength radiation than
Exterior Paints
filtered open-flame or enclosed carbon arcs.
D714 Test Method for Evaluating Degree of Blistering of
1.3 The values stated in either SI units or inch-pound units
Paints
are to be regarded separately as standard. The values stated in
D772 Test Method for Evaluating Degree of Flaking (Scal-
each system may not be exact equivalents; therefore, each
ing) of Exterior Paints
system shall be used independently of the other. Combining
D823 Practices for Producing Films of Uniform Thickness
values from the two systems may result in non-conformance
of Paint, Coatings and Related Products on Test Panels
with the standard.
D1005 Test Method for Measurement of Dry-Film Thick-
1.4 This standard does not purport to address all of the ness of Organic Coatings Using Micrometers
safety concerns, if any, associated with its use. It is the D1186 Test Methods for Nondestructive Measurement of
responsibility of the user of this standard to establish appro- Dry Film Thickness of Nonmagnetic Coatings Applied to
priate safety, health, and environmental practices and deter- a Ferrous Base (Withdrawn 2006)
mine the applicability of regulatory limitations prior to use.
D1400 TestMethodforNondestructiveMeasurementofDry
1.5 This international standard was developed in accor- Film Thickness of Nonconductive Coatings Applied to a
dance with internationally recognized principles on standard- Nonferrous Metal Base (Withdrawn 2006)
ization established in the Decision on Principles for the D1729 Practice for Visual Appraisal of Colors and Color
Development of International Standards, Guides and Recom-
Differences of Diffusely-Illuminated Opaque Materials
mendations issued by the World Trade Organization Technical D1730 Practices for Preparation of Aluminum and
Barriers to Trade (TBT) Committee.
Aluminum-Alloy Surfaces for Painting
1 2
This practice is under the jurisdiction of ASTM Committee D01 on Paint and For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Related Coatings, Materials, and Applications and is the direct responsibility of contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Subcommittee D01.27 on Accelerated Testing. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Sept. 1, 2018. Published September 2018. Originally the ASTM website.
approved in 1945. Last previous edition approved in 2013 as D822/D822M – 13. The last approved version of this historical standard is referenced on
DOI: 10.1520/D0822_D0822M-13R18. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D822/D822M − 13 (2018)
A
TABLE 1 Test Cycles Commonly Used for Filtered Open-Flame Carbon-Arc Exposure Testing of Paints and Related Coatings
Uninsulated Black
B,C,D
Panel Temperature
B,C E
Cycle Number Cycle Description °C °F Typical Uses
F
1 Continuous light 63 ± 2.5 145 ± 5 General coatings and historical convention
102 min light only at 50 ± 10 % RH
G
18 min light and water spray
Repeat continuously
2 18 h continuous light using: 63±2.5 145±5 General coatings
102 min light only at 50 ± 10 % RH 24±1.5 75±3
18 min light and water spray
6 h dark using:
95 % relative humidity (no water spray)
Repeat continuously
3 48min light at 50±10%RH 63 ± 2.5 145 ± 5 Coatings used in original equipment manufacturing
12 min light and water spray
Repeat continuously
4 4 h light at 50 ± 10% RH 63 ± 2.5 145 ± 5 Exterior pigmented stains
4 h dark with water spray
Repeat continuously
5 12hlight at 50±10%RH 63 ± 2.5 145 ± 5 Exterior wood stains and clears
12 h dark water spray
Repeat continuously
6 8hlight at 50±10%RH 63 ± 2.5 145 ± 5 Marine enamels
10 h light and water spray
6 h dark with water spray
Repeat continuously
A
The cycles described are not listed in any order indicating importance, and are not necessarily recommended for the applications listed.
B
Unless otherwise specified, operate the device so that the allowable deviations about the set points given in Table 1 are within the specified limits specified in the
corresponding entry. If the actual operating conditions do not agree with the machine settings after the equipment has stabilized, discontinue the test and correct the cause
of the disagreement before continuing.
C
Set points and operational fluctuations are listed as set point ± operational fluctuation in Table 1. They are sometimes listed in separate columns. The set point is the
target condition for the sensor used at the operational control point as programmed by the user. Operational fluctuations are deviations from the indicated set point at the
control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty. At the operational control
point, the operational fluctuation can exceed no more than the listed value at equilibrium. Therefore, when a standard calls for a particular set point, the user programs
that exact number. The operational fluctuations specified with the set point do not imply that the user is allowed to program a set point higher or lower than the exact set
point specified.
D
Unless otherwise indicated, black panel temperatures apply during the light-only portion of the cycle. The equilibrium black panel temperature is obtained without a spray
period. For light intervals less than 30 min, the black panel temperature might not reach equilibrium.
E
Typical uses do not imply that results from exposures of these materials according to the cycle described will correlate to those from actual use conditions.
F
Historical convention has established this as a very commonly used test cycle. This cycle may not adequately simulate the effects of outdoor exposure.
G
Unless otherwise specified, water spray refers to water sprayed on the exposed surfaces of the test specimens.
D2244 Practice for Calculation of Color Tolerances and G151 Practice for Exposing Nonmetallic Materials inAccel-
Color Differences from Instrumentally Measured Color erated Test Devices that Use Laboratory Light Sources
Coordinates G152 Practice for Operating Open Flame Carbon Arc Light
D2616 Test Method for Evaluation of Visual Color Differ- Apparatus for Exposure of Nonmetallic Materials
ence With a Gray Scale G169 Guide for Application of Basic Statistical Methods to
D3361/D3361M Practice for Unfiltered Open-Flame Weathering Tests
Carbon-Arc Exposures of Paint and Related Coatings
3. Terminology
D4214 Test Methods for Evaluating the Degree of Chalking
3.1 The definitions given in Terminology G113 are appli-
of Exterior Paint Films
cable to this practice.
D5031/D5031M Practice for Enclosed Carbon-Arc Expo-
sure Tests of Paint and Related Coatings
4. Significance and Use
D5870 Practice for Calculating Property Retention Index of
4.1 The ability of a paint or coating to resist deterioration of
Plastics
its physical and optical properties caused by exposure to light,
E691 Practice for Conducting an Interlaboratory Study to
heat, and water can be very significant for many applications.
Determine the Precision of a Test Method
This practice is intended to induce property changes associated
E1347 Test Method for Color and Color-Difference Mea-
with end-use conditions, including the effects of sunlight,
surement by Tristimulus Colorimetry
moisture, and heat. The exposure used in this practice is not
G113 Terminology Relating to Natural andArtificial Weath-
intended to simulate the deterioration caused by localized
ering Tests of Nonmetallic Materials
weather phenomena such as atmospheric pollution, biological
G141 Guide for Addressing Variability in Exposure Testing
attack, and saltwater exposure.
of Nonmetallic Materials
G147 Practice for Conditioning and Handling of Nonmetal- 4.2 Cautions—Variation in results may be expected when
lic Materials for Natural and Artificial Weathering Tests different operating conditions are used.Therefore, no reference
D822/D822M − 13 (2018)
to the use of this practice shall be made unless accompanied by 6.2 The burning carbon rods used in these devices become
a report prepared according to Section 10 that describes the very hot during use. Make sure to allow at least 15 min for the
specific operating conditions used. Refer to Practice G151 for arcs to cool after the device is turned off before attempting to
detailed information on the caveats applicable to use of results change the carbon rods.
obtained according to this practice.
6.3 Carbon residue and ash are known respiratory irritants.
Wearanappropriatehigh-efficiencydustrespirator,gloves,and
NOTE 1—Additional information on sources of variability and on
strategies for addressing variability in the design, execution, and data
safety glasses when handling or changing carbon rods. Make
analysis of laboratory accelerated exposure tests is found in Guide G141.
sure to wash any carbon residue from hands or arms prior to
4.2.1 The spectral power distribution of light from an
eating or drinking.
open-flame carbon-arc is significantly different from that
produced in light and water exposure devices using other
7. Test Specimens
carbon-arc configurations or other light sources. The type and
7.1 Apply the coating to flat (plane) panels with the
rate of degradation and the performance rankings produced by
substrate, method of preparation, method of application, coat-
exposures to filtered open-flame carbon-arcs can be much
ing system, film thickness, and method of drying consistent
different from those produced by exposures to other types of
with the anticipated end use, or as mutually agreed upon
laboratory light sources.
between the producer and user.
4.2.2 Interlaboratory comparisons are valid only when all
7.2 Panel specifications and methods of preparation include
laboratories use the same type of carbon-arc, filters, and
but are not limited to Practices D609 or D1730, or Specifica-
exposure conditions.
tion D358. Select panel sizes suitable for use with the exposure
4.3 Reproducibility of test results between laboratories has
apparatus.
been shown to be good when the stability of materials is
7.3 Coat test panels in accordance withTest Methods D823,
evaluated in terms of performance ranking compared to other
4,5
then measure the film thickness in accordance with an appro-
materials or to a control. Therefore, exposure of a similar
priate procedure selected fromTest MethodsD1005, D1186,or
material of known performance (a control) at the same time as
D1400. Nondestructive methods are preferred because panels
the test materials is strongly recommended. It is recommended
so measured need not be repaired.
that at least three replicates of each material be exposed to
allow for statistical evaluation of results.
7.4 Prior to exposing coated panels in the apparatus, condi-
tion them at 23 6 2°C [73 6 3°F] and 50 6 10 % relative
4.4 Test results will depend upon the care that is taken to
humidity for one of the following periods in accordance with
operate the equipment according to Practice G152. Significant
the type of coating:
factors include regulation of line voltage, freedom from salt or
other deposits from water, temperature and humidity control,
Baked coatings 24 h
Radiation-cured coatings 24 h
and conditions of the electrodes.
All other coatings 7 days
4.5 All references to exposures in accordance with this
7.4.1 Other procedures for preparation of test specimens
practice must include a complete description of the test cycle
may be used if agreed upon between all interested parties.
used.
7.5 Mount specimens in holders so that only the minimum
5. Apparatus
specimen area required for support by the holder is covered.
Do not use this covered area of the specimen as part of the test
5.1 Use filtered open-flame carbon-arc apparatus that con-
area.
forms to the requirements defined in Practices G151 and G152.
7.6 Unless otherwise specified, expose at least three repli-
5.2 Unless otherwise specified, the spectral power distribu-
cate specimens of each test and control material.
tion of the filtered open-flame carbon-arc shall conform to the
requirements in Practice G152 for carbon arc with daylight
7.7 Follow the procedures described in Practice G147 for
filters.
identification and conditioning and handling of specimens of
test, control, and reference materials prior to, during, and after
6. Hazards
exposure.
6.1 Warning—In addition to other precautions, never look
7.8 Do not mask the face of a specimen for the purpose of
directly at the carbon arc because UVradiation can damage the
showing on one panel
...
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D822/D822M − 13 (Reapproved 2018)
Standard Practice for
Filtered Open-Flame Carbon-Arc Exposures of Paint and
Related Coatings
This standard is issued under the fixed designation D822/D822M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope 2. Referenced Documents
1.1 This practice covers the selection of test conditions for 2.1 ASTM Standards:
accelerated exposure testing of coatings and related products in D358 Specification for Wood to Be Used as Panels in
filtered open-flame carbon-arc devices conducted according to Weathering Tests of Coatings (Withdrawn 2014)
Practices G151 and G152. This practice also covers the D523 Test Method for Specular Gloss
preparation of test specimens, the test conditions suited for D609 Practice for Preparation of Cold-Rolled Steel Panels
coatings, and the evaluation of test results. Table 1 describes for Testing Paint, Varnish, Conversion Coatings, and
commonly used test conditions. Related Coating Products
D610 Practice for Evaluating Degree of Rusting on Painted
1.2 This practice does not cover enclosed carbon-arc expo-
Steel Surfaces
sures of paints and related coatings, which is described in
D659 Method for Evaluating Degree of Chalking of Exterior
Practice D5031/D5031M. Another procedure for exposing
Paints (Withdrawn 1990)
these products is covered by Practice D3361/D3361M, in
D660 Test Method for Evaluating Degree of Checking of
which the specimens are subjected to radiation from an
Exterior Paints
unfiltered open-flame carbon arc that produces shorter wave-
D662 Test Method for Evaluating Degree of Erosion of
lengths and higher levels of short wavelength radiation than
Exterior Paints
filtered open-flame or enclosed carbon arcs.
D714 Test Method for Evaluating Degree of Blistering of
1.3 The values stated in either SI units or inch-pound units
Paints
are to be regarded separately as standard. The values stated in
D772 Test Method for Evaluating Degree of Flaking (Scal-
each system may not be exact equivalents; therefore, each
ing) of Exterior Paints
system shall be used independently of the other. Combining
D823 Practices for Producing Films of Uniform Thickness
values from the two systems may result in non-conformance
of Paint, Coatings and Related Products on Test Panels
with the standard.
D1005 Test Method for Measurement of Dry-Film Thick-
1.4 This standard does not purport to address all of the ness of Organic Coatings Using Micrometers
safety concerns, if any, associated with its use. It is the D1186 Test Methods for Nondestructive Measurement of
responsibility of the user of this standard to establish appro- Dry Film Thickness of Nonmagnetic Coatings Applied to
priate safety, health, and environmental practices and deter- a Ferrous Base (Withdrawn 2006)
mine the applicability of regulatory limitations prior to use. D1400 Test Method for Nondestructive Measurement of Dry
1.5 This international standard was developed in accor- Film Thickness of Nonconductive Coatings Applied to a
dance with internationally recognized principles on standard- Nonferrous Metal Base (Withdrawn 2006)
ization established in the Decision on Principles for the D1729 Practice for Visual Appraisal of Colors and Color
Development of International Standards, Guides and Recom- Differences of Diffusely-Illuminated Opaque Materials
mendations issued by the World Trade Organization Technical
D1730 Practices for Preparation of Aluminum and
Barriers to Trade (TBT) Committee. Aluminum-Alloy Surfaces for Painting
1 2
This practice is under the jurisdiction of ASTM Committee D01 on Paint and For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Related Coatings, Materials, and Applications and is the direct responsibility of contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Subcommittee D01.27 on Accelerated Testing. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Sept. 1, 2018. Published September 2018. Originally the ASTM website.
approved in 1945. Last previous edition approved in 2013 as D822/D822M – 13. The last approved version of this historical standard is referenced on
DOI: 10.1520/D0822_D0822M-13R18. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D822/D822M − 13 (2018)
A
TABLE 1 Test Cycles Commonly Used for Filtered Open-Flame Carbon-Arc Exposure Testing of Paints and Related Coatings
Uninsulated Black
B,C,D
Panel Temperature
B,C E
Cycle Number Cycle Description °C °F Typical Uses
F
1 Continuous light 63 ± 2.5 145 ± 5 General coatings and historical convention
102 min light only at 50 ± 10 % RH
G
18 min light and water spray
Repeat continuously
2 18 h continuous light using: 63 ± 2.5 145 ± 5 General coatings
102 min light only at 50 ± 10 % RH 24 ± 1.5 75 ± 3
18 min light and water spray
6 h dark using:
95 % relative humidity (no water spray)
Repeat continuously
3 48 min light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Coatings used in original equipment manufacturing
12 min light and water spray
Repeat continuously
4 4 h light at 50 ± 10% RH 63 ± 2.5 145 ± 5 Exterior pigmented stains
4 h dark with water spray
Repeat continuously
5 12 h light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Exterior wood stains and clears
12 h dark water spray
Repeat continuously
6 8 h light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Marine enamels
10 h light and water spray
6 h dark with water spray
Repeat continuously
A
The cycles described are not listed in any order indicating importance, and are not necessarily recommended for the applications listed.
B
Unless otherwise specified, operate the device so that the allowable deviations about the set points given in Table 1 are within the specified limits specified in the
corresponding entry. If the actual operating conditions do not agree with the machine settings after the equipment has stabilized, discontinue the test and correct the cause
of the disagreement before continuing.
C
Set points and operational fluctuations are listed as set point ± operational fluctuation in Table 1. They are sometimes listed in separate columns. The set point is the
target condition for the sensor used at the operational control point as programmed by the user. Operational fluctuations are deviations from the indicated set point at the
control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty. At the operational control
point, the operational fluctuation can exceed no more than the listed value at equilibrium. Therefore, when a standard calls for a particular set point, the user programs
that exact number. The operational fluctuations specified with the set point do not imply that the user is allowed to program a set point higher or lower than the exact set
point specified.
D
Unless otherwise indicated, black panel temperatures apply during the light-only portion of the cycle. The equilibrium black panel temperature is obtained without a spray
period. For light intervals less than 30 min, the black panel temperature might not reach equilibrium.
E
Typical uses do not imply that results from exposures of these materials according to the cycle described will correlate to those from actual use conditions.
F
Historical convention has established this as a very commonly used test cycle. This cycle may not adequately simulate the effects of outdoor exposure.
G
Unless otherwise specified, water spray refers to water sprayed on the exposed surfaces of the test specimens.
D2244 Practice for Calculation of Color Tolerances and G151 Practice for Exposing Nonmetallic Materials in Accel-
Color Differences from Instrumentally Measured Color erated Test Devices that Use Laboratory Light Sources
Coordinates G152 Practice for Operating Open Flame Carbon Arc Light
D2616 Test Method for Evaluation of Visual Color Differ- Apparatus for Exposure of Nonmetallic Materials
ence With a Gray Scale G169 Guide for Application of Basic Statistical Methods to
D3361/D3361M Practice for Unfiltered Open-Flame Weathering Tests
Carbon-Arc Exposures of Paint and Related Coatings
3. Terminology
D4214 Test Methods for Evaluating the Degree of Chalking
3.1 The definitions given in Terminology G113 are appli-
of Exterior Paint Films
cable to this practice.
D5031/D5031M Practice for Enclosed Carbon-Arc Expo-
sure Tests of Paint and Related Coatings
4. Significance and Use
D5870 Practice for Calculating Property Retention Index of
4.1 The ability of a paint or coating to resist deterioration of
Plastics
its physical and optical properties caused by exposure to light,
E691 Practice for Conducting an Interlaboratory Study to
heat, and water can be very significant for many applications.
Determine the Precision of a Test Method
This practice is intended to induce property changes associated
E1347 Test Method for Color and Color-Difference Mea-
with end-use conditions, including the effects of sunlight,
surement by Tristimulus Colorimetry
moisture, and heat. The exposure used in this practice is not
G113 Terminology Relating to Natural and Artificial Weath-
intended to simulate the deterioration caused by localized
ering Tests of Nonmetallic Materials
weather phenomena such as atmospheric pollution, biological
G141 Guide for Addressing Variability in Exposure Testing
attack, and saltwater exposure.
of Nonmetallic Materials
G147 Practice for Conditioning and Handling of Nonmetal- 4.2 Cautions—Variation in results may be expected when
lic Materials for Natural and Artificial Weathering Tests different operating conditions are used. Therefore, no reference
D822/D822M − 13 (2018)
to the use of this practice shall be made unless accompanied by 6.2 The burning carbon rods used in these devices become
a report prepared according to Section 10 that describes the very hot during use. Make sure to allow at least 15 min for the
specific operating conditions used. Refer to Practice G151 for arcs to cool after the device is turned off before attempting to
detailed information on the caveats applicable to use of results change the carbon rods.
obtained according to this practice.
6.3 Carbon residue and ash are known respiratory irritants.
NOTE 1—Additional information on sources of variability and on Wear an appropriate high-efficiency dust respirator, gloves, and
strategies for addressing variability in the design, execution, and data
safety glasses when handling or changing carbon rods. Make
analysis of laboratory accelerated exposure tests is found in Guide G141.
sure to wash any carbon residue from hands or arms prior to
4.2.1 The spectral power distribution of light from an eating or drinking.
open-flame carbon-arc is significantly different from that
produced in light and water exposure devices using other 7. Test Specimens
carbon-arc configurations or other light sources. The type and
7.1 Apply the coating to flat (plane) panels with the
rate of degradation and the performance rankings produced by
substrate, method of preparation, method of application, coat-
exposures to filtered open-flame carbon-arcs can be much
ing system, film thickness, and method of drying consistent
different from those produced by exposures to other types of
with the anticipated end use, or as mutually agreed upon
laboratory light sources.
between the producer and user.
4.2.2 Interlaboratory comparisons are valid only when all
7.2 Panel specifications and methods of preparation include
laboratories use the same type of carbon-arc, filters, and
but are not limited to Practices D609 or D1730, or Specifica-
exposure conditions.
tion D358. Select panel sizes suitable for use with the exposure
4.3 Reproducibility of test results between laboratories has
apparatus.
been shown to be good when the stability of materials is
7.3 Coat test panels in accordance with Test Methods D823,
evaluated in terms of performance ranking compared to other
4,5
then measure the film thickness in accordance with an appro-
materials or to a control. Therefore, exposure of a similar
priate procedure selected from Test Methods D1005, D1186, or
material of known performance (a control) at the same time as
D1400. Nondestructive methods are preferred because panels
the test materials is strongly recommended. It is recommended
so measured need not be repaired.
that at least three replicates of each material be exposed to
allow for statistical evaluation of results.
7.4 Prior to exposing coated panels in the apparatus, condi-
tion them at 23 6 2°C [73 6 3°F] and 50 6 10 % relative
4.4 Test results will depend upon the care that is taken to
humidity for one of the following periods in accordance with
operate the equipment according to Practice G152. Significant
the type of coating:
factors include regulation of line voltage, freedom from salt or
other deposits from water, temperature and humidity control,
Baked coatings 24 h
Radiation-cured coatings 24 h
and conditions of the electrodes.
All other coatings 7 days
4.5 All references to exposures in accordance with this
7.4.1 Other procedures for preparation of test specimens
practice must include a complete description of the test cycle
may be used if agreed upon between all interested parties.
used.
7.5 Mount specimens in holders so that only the minimum
5. Apparatus specimen area required for support by the holder is covered.
Do not use this covered area of the specimen as part of the test
5.1 Use filtered open-flame carbon-arc apparatus that con-
area.
forms to the requirements defined in Practices G151 and G152.
7.6 Unless otherwise specified, expose at least three repli-
5.2 Unless otherwise specified, the spectral power distribu-
cate specimens of each test and control material.
tion of the filtered open-flame carbon-arc shall conform to the
requirements in Practice G152 for carbon arc with daylight
7.7 Follow the procedures described in Practice G147 for
filters.
identification and conditioning and handling of specimens of
test, control, and reference materials prior to, during, and after
6. Hazards
exposure.
6.1 Warning—In addition to other precautions, never look
7.8 Do not mask the face of a specimen for the purpose of
directly at the carbon arc because UV radiation can damage the
showing on one panel the effects of various exposure times.
eye. Most carbo
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D822/D822M − 13 D822/D822M − 13 (Reapproved 2018)
Standard Practice for
Filtered Open-Flame Carbon-Arc Exposures of Paint and
Related Coatings
This standard is issued under the fixed designation D822/D822M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*Scope
1.1 This practice covers the selection of test conditions for accelerated exposure testing of coatings and related products in
filtered open-flame carbon-arc devices conducted according to Practices G151 and G152. This practice also covers the preparation
of test specimens, the test conditions suited for coatings, and the evaluation of test results. Table 1 describes commonly used test
conditions.
1.2 This practice does not cover enclosed carbon-arc exposures of paints and related coatings, which is described in Practice
D5031/D5031M. Another procedure for exposing these products is covered by Practice D3361/D3361M, in which the specimens
are subjected to radiation from an unfiltered open-flame carbon arc that produces shorter wavelengths and higher levels of short
wavelength radiation than filtered open-flame or enclosed carbon arcs.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2.1 ASTM Standards:
D358 Specification for Wood to Be Used as Panels in Weathering Tests of Coatings (Withdrawn 2014)
D523 Test Method for Specular Gloss
D609 Practice for Preparation of Cold-Rolled Steel Panels for Testing Paint, Varnish, Conversion Coatings, and Related Coating
Products
D610 Practice for Evaluating Degree of Rusting on Painted Steel Surfaces
D659 Method for Evaluating Degree of Chalking of Exterior Paints (Withdrawn 1990)
D660 Test Method for Evaluating Degree of Checking of Exterior Paints
D662 Test Method for Evaluating Degree of Erosion of Exterior Paints
D714 Test Method for Evaluating Degree of Blistering of Paints
D772 Test Method for Evaluating Degree of Flaking (Scaling) of Exterior Paints
D823 Practices for Producing Films of Uniform Thickness of Paint, Coatings and Related Products on Test Panels
D1005 Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
This practice is under the jurisdiction of ASTM Committee D01 on Paint and Related Coatings, Materials, and Applications and is the direct responsibility of
Subcommittee D01.27 on Accelerated Testing.
Current edition approved Oct. 1, 2013Sept. 1, 2018. Published October 2013September 2018. Originally approved in 1945. Last previous edition approved in 20062013
as D822 – 01 (2006).D822/D822M – 13. DOI: 10.1520/D0822_D0822M-13.10.1520/D0822_D0822M-13R18.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
The last approved version of this historical standard is referenced on www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D822/D822M − 13 (2018)
A
TABLE 1 Test Cycles Commonly Used for Filtered Open-Flame Carbon-Arc Exposure Testing of Paints and Related Coatings
Uninsulated Black
B,C,D
Panel Temperature
B,C E
Cycle Number Cycle Description °C °F Typical Uses
F
1 Continuous light 63 ± 2.5 145 ± 5 General coatings and historical convention
102 min light only at 50 ± 10 % RH
G
18 min light and water spray
Repeat continuously
2 18 h continuous light using: 63 ± 2.5 145 ± 5 General coatings
102 min light only at 50 ± 10 % RH 24 ± 1.5 75 ± 3
18 min light and water spray
6 h dark using:
95 % relative humidity (no water spray)
Repeat continuously
3 48 min light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Coatings used in original equipment manufacturing
12 min light and water spray
Repeat continuously
4 4 h light at 50 ± 10% RH 63 ± 2.5 145 ± 5 Exterior pigmented stains
4 h dark with water spray
Repeat continuously
5 12 h light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Exterior wood stains and clears
12 h dark water spray
Repeat continuously
6 8 h light at 50 ± 10 % RH 63 ± 2.5 145 ± 5 Marine enamels
10 h light and water spray
6 h dark with water spray
Repeat continuously
A
The cycles described are not listed in any order indicating importance, and are not necessarily recommended for the applications listed.
B
Unless otherwise specified, operate the device so that the allowable deviations about the set points given in Table 1 are within the specified limits specified in the
corresponding entry. If the actual operating conditions do not agree with the machine settings after the equipment has stabilized, discontinue the test and correct the cause
of the disagreement before continuing.
C
Set points and operational fluctuations are listed as set point ± operational fluctuation in Table 1. They are sometimes listed in separate columns. The set point is the
target condition for the sensor used at the operational control point as programmed by the user. Operational fluctuations are deviations from the indicated set point at the
control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty. At the operational control
point, the operational fluctuation can exceed no more than the listed value at equilibrium. Therefore, when a standard calls for a particular set point, the user programs
that exact number. The operational fluctuations specified with the set point do not imply that the user is allowed to program a set point higher or lower than the exact set
point specified.
D
Unless otherwise indicated, black panel temperatures apply during the light-only portion of the cycle. The equilibrium black panel temperature is obtained without a spray
period. For light intervals less than 30 min, the black panel temperature might not reach equilibrium.
E
Typical uses do not imply that results from exposures of these materials according to the cycle described will correlate to those from actual use conditions.
F
Historical convention has established this as a very commonly used test cycle. This cycle may not adequately simulate the effects of outdoor exposure.
G
Unless otherwise specified, water spray refers to water sprayed on the exposed surfaces of the test specimens.
D1186 Test Methods for Nondestructive Measurement of Dry Film Thickness of Nonmagnetic Coatings Applied to a Ferrous
Base (Withdrawn 2006)
D1400 Test Method for Nondestructive Measurement of Dry Film Thickness of Nonconductive Coatings Applied to a
Nonferrous Metal Base (Withdrawn 2006)
D1729 Practice for Visual Appraisal of Colors and Color Differences of Diffusely-Illuminated Opaque Materials
D1730 Practices for Preparation of Aluminum and Aluminum-Alloy Surfaces for Painting
D2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
D2616 Test Method for Evaluation of Visual Color Difference With a Gray Scale
D3361/D3361M Practice for Unfiltered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings
D4214 Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films
D5031/D5031M Practice for Enclosed Carbon-Arc Exposure Tests of Paint and Related Coatings
D5870 Practice for Calculating Property Retention Index of Plastics
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E1347 Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry
G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials
G141 Guide for Addressing Variability in Exposure Testing of Nonmetallic Materials
G147 Practice for Conditioning and Handling of Nonmetallic Materials for Natural and Artificial Weathering Tests
G151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
G152 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials
G169 Guide for Application of Basic Statistical Methods to Weathering Tests
3. Terminology
3.1 The definitions given in Terminology G113 are applicable to this practice.
D822/D822M − 13 (2018)
4. Significance and Use
4.1 The ability of a paint or coating to resist deterioration of its physical and optical properties caused by exposure to light, heat,
and water can be very significant for many applications. This practice is intended to induce property changes associated with
end-use conditions, including the effects of sunlight, moisture, and heat. The exposure used in this practice is not intended to
simulate the deterioration caused by localized weather phenomena such as atmospheric pollution, biological attack, and saltwater
exposure.
4.2 Cautions—Variation in results may be expected when different operating conditions are used. Therefore, no reference to the
use of this practice shall be made unless accompanied by a report prepared according to Section 10 that describes the specific
operating conditions used. Refer to Practice G151 for detailed information on the caveats applicable to use of results obtained
according to this practice.
NOTE 1—Additional information on sources of variability and on strategies for addressing variability in the design, execution, and data analysis of
laboratory accelerated exposure tests is found in Guide G141.
4.2.1 The spectral power distribution of light from an open-flame carbon-arc is significantly different from that produced in light
and water exposure devices using other carbon-arc configurations or other light sources. The type and rate of degradation and the
performance rankings produced by exposures to filtered open-flame carbon-arcs can be much different from those produced by
exposures to other types of laboratory light sources.
4.2.2 Interlaboratory comparisons are valid only when all laboratories use the same type of carbon-arc, filters, and exposure
conditions.
4.3 Reproducibility of test results between laboratories has been shown to be good when the stability of materials is evaluated
4,5
in terms of performance ranking compared to other materials or to a control. Therefore, exposure of a similar material of known
performance (a control) at the same time as the test materials is strongly recommended. It is recommended that at least three
replicates of each material be exposed to allow for statistical evaluation of results.
4.4 Test results will depend upon the care that is taken to operate the equipment according to Practice G152. Significant factors
include regulation of line voltage, freedom from salt or other deposits from water, temperature and humidity control, and
conditions of the electrodes.
4.5 All references to exposures in accordance with this practice must include a complete description of the test cycle used. All
references to exposures in accordance with this practice must include a complete description of the test cycle used.
5. Apparatus
5.1 Use filtered open-flame carbon-arc apparatus that conforms to the requirements defined in Practices G151 and G152.
5.2 Unless otherwise specified, the spectral power distribution of the filtered open-flame carbon-arc shall conform to the
requirements in Practice G152 for carbon arc with daylight filters.
6. Hazards
6.1 Warning—In addition to other precautions, never look directly at the carbon arc because UV radiation can damage the eye.
Most carbon-arc machines are equipped with door safety switches, but users of old equipment must be certain to turn off the power
to the carbon arc before opening the test-chamber door.
6.2 The burning carbon rods used in these devices become very hot during use. Make sure to allow at least 15 min for the arcs
to cool after the device is turned off before attempting to change the carbon rods.
6.3 Carbon residue and ash are known respiratory irritants. Wear an appropriate high-efficiency dust respirator, gloves, and
safety glasses when handling or changing carbon rods. Make sure to wash any carbon residue from hands or arms prior to eating
or drinking.
7. Test Specimens
7.1 Apply the coating to flat (plane) panels with the substrate, method of preparation, method of application, coating system,
film thickness, and method of drying consistent with the anticipated end use, or as mutually agreed upon between the producer
and user.
7.2 Panel specifications and methods of preparation include but are not limited to Practices D609 or D1730, or Specification
D358. Select panel sizes suitable for use with the exposure apparatus.
Fischer, R., “Results of Round-Robin Studies of Light- and Water-Exposure Standard Practices,” Accelerated and Outdoor Durability Testing of Organic Materials,
ASTM STP 1202, ASTM, 1993.
Ketola, W., and Fischer, R., “Characterization and Use of Reference Materials in Accelerated Durability Tests,” VAMAS Technical Report No. 30, NIST, June 1997.
D822/D822M − 13 (2018)
7.3 Coat test panels in accordance with Test Methods D823, then measure the film thickness in accordance with an appropriate
procedure selected from Test Methods D1005, D1186, or D14
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.