Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings

ABSTRACT
This specification covers requirements and test methods for fabricated poly(vinyl chloride) (PVC) plastic schedule 40 drainage and DWV fittings. These fabricated fittings are manufactured from pipe, or from a combination of pipe and injection molded parts. Resistance to bending test, leak test, and solvent weld bond area test shall be performed to meet the requirements prescribed. The spigot diameter, spigot length, wall thickness, socket diameter, and socket length shall be tested to meet the requirements prescribed.
SCOPE
1.1 This specification covers requirements and test methods for fabricated poly(vinyl chloride) (PVC) plastic schedule 40 drainage and DWV fittings to be used with piping manufactured in accordance with Specification D 2665, D 1785, or F 891. These fabricated fittings are manufactured from pipe, or from a combination of pipe and injection molded parts.
1.2 The requirements of this specification are to provide fabricated PVC fittings suitable for drainage and venting of sanitary waste systems, storm water systems, and certain other liquid wastes. Fittings shall have solvent cement joints, gasket joints or a combination thereof.
1.3 The text of this specification references notes, footnotes, and appendixes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Jun-2007
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1866-07 - Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1866 −07 AnAmerican National Standard
Standard Specification for
Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage
1
and DWV Fabricated Fittings
This standard is issued under the fixed designation F1866; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
(CPVC) Compounds
for fabricated poly(vinyl chloride) (PVC) plastic schedule 40
D1785 Specification for Poly(Vinyl Chloride) (PVC) Plastic
drainage and DWV fittings to be used with piping manufac-
Pipe, Schedules 40, 80, and 120
tured in accordance with Specifications D2665, D1785,or
D2122 Test Method for Determining Dimensions of Ther-
F891. These fabricated fittings are manufactured from pipe, or
moplastic Pipe and Fittings
from a combination of pipe and injection molded parts.
D2564 Specification for Solvent Cements for Poly(Vinyl
1.2 The requirements of this specification are to provide
Chloride) (PVC) Plastic Piping Systems
fabricated PVC fittings suitable for drainage and venting of
D2665 Specification for Poly(Vinyl Chloride) (PVC) Plastic
sanitary waste systems, storm water systems, and certain other
Drain, Waste, and Vent Pipe and Fittings
liquid wastes. Fittings shall have solvent cement joints, gasket
D2855 Practice for Making Solvent-Cemented Joints with
joints or a combination thereof.
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
1.3 The text of this specification references notes, footnotes, D3212 Specification for Joints for Drain and Sewer Plastic
and appendixes that provide explanatory material. These notes
Pipes Using Flexible Elastomeric Seals
and footnotes (excluding those in tables and figures) shall not
F412 Terminology Relating to Plastic Piping Systems
be considered as requirements of the specification.
F477 Specification for Elastomeric Seals (Gaskets) for Join-
ing Plastic Pipe
1.4 The values stated in inch-pound units are to be regarded
F656 Specification for Primers for Use in Solvent Cement
as the standard. The values given in parentheses are provided
Joints of Poly(Vinyl Chloride) (PVC) Plastic Pipe and
for information only.
Fittings
1.5 The following safety hazards caveat pertains only to the
F891 Specification for Coextruded Poly(Vinyl Chloride)
test method portion, Section 10, of this specification. This
(PVC) Plastic Pipe With a Cellular Core
standard does not purport to address all of the safety concerns,
F913 Specification for Thermoplastic Elastomeric Seals
if any, associated with its use. It is the responsibility of the user
(Gaskets) for Joining Plastic Pipe
of this standard to establish appropriate safety and health
practices and determine the applicability of regulatory limita-
3. Terminology
tions prior to use.
3.1 Definitions—Definitions are in accordance with Termi-
2. Referenced Documents
nology F412, and abbreviations are in accordance with Termi-
2
nology D1600, unless otherwise specified.
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
4. Materials and Manufacture
D1600 Terminology forAbbreviatedTerms Relating to Plas-
tics
4.1 Basic Materials—The molded components for fabri-
cated fittings shall be made of virgin or rework PVC com-
pounds meeting or exceeding the requirements of Class 12454
1
This standard is under the jurisdiction of Committee F17 on Plastic Piping
as defined in Specification D1784.
Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved June 15, 2007. Published July 2007. Originally
4.1.1 The pipe shall be made of PVC that meets the
approved in 1998. Last previous edition approved in 2005 as F1866–05. DOI:
requirements of the Materials Section of Specification D1785
10.1520/F1866-07.
2 or D2665.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
4.2 Gaskets—Elastomeric seals (gaskets) shall comply with
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. the requirements of Specification F477 or F913.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1866−07
4.3 Lubricant—The lubricant used for field assembly shall 6.4 Solvent Cement Sockets:
be the type recommended by the manufacturer of the fitting. 6.4.1 Socket Diameter—The inside diameter of the fitting
Prolonged exposure to the lubricant shall no
...

Questions, Comments and Discussion