ASTM C16-81(2001)
(Test Method)Standard Test Method for Load Testing Refractory Brick at High Temperatures
Standard Test Method for Load Testing Refractory Brick at High Temperatures
SCOPE
1.1 This test method covers the determination of the resistance to deformation or shear of refractory brick when subjected to a specified compressive load at a specified temperature for a specified time.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: C 16 – 81 (Reapproved 2001)
Standard Test Method for
1
Load Testing Refractory Brick at High Temperatures
ThisstandardisissuedunderthefixeddesignationC16;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2 This test method is not applicable for refractory mate-
rials that are unstable in an oxidizing atmosphere unless means
1.1 This test method covers the determination of the resis-
are provided to protect the specimens.
tance to deformation or shear of refractory brick when sub-
jected to a specified compressive load at a specified tempera-
4. Apparatus
ture for a specified time.
4.1 The apparatus shall consist essentially of a furnace and
1.2 The values stated in inch-pound units are to be regarded
a loading device. It may be constructed in accordance with Fig.
as the standard. The values given in parentheses are for
3
1 or Fig. 2 or their equivalent.
information only.
4.1.1 The furnace shall be so constructed that the tempera-
1.3 This standard does not purport to address all of the
ture is substantially uniform in all parts of the furnace. The
safety concerns, if any, associated with its use. It is the
temperature as measured at any point on the surface of the test
responsibility of the user of this standard to establish appro-
specimens shall not differ by more than 10°F (5.5°C) during
priate safety and health practices and determine the applica-
the holding period of the test or, on test to failure, above
bility of regulatory limitations prior to use.
2370°F (1300°C). To accomplish this, it may be necessary to
2. Referenced Documents install and adjust baffles within the furnace.Aminimum of two
burners shall be used. If difficulty is encountered in following
2.1 ASTM Standards:
the low-temperature portion of the schedule (particularly for
E 220 Method for Calibration of Thermocouples by Com-
2
silica brick), a dual-burner system is recommended, one to
parison Techniques
supply heat for low temperatures and another for the higher
3. Significance and Use
temperatures.
4.2 The temperature shall be measured either with cali-
3.1 The ability of a refractory brick to withstand prescribed
, ,
4 5 6
brated platinum - platinum - rhodium thermocouples, each
loads at elevated temperatures is a measure of the high-
encased in a protection tube with the junction not more than 1
temperature service potential of the material. By definition,
in. (25 mm) from the center of the side or edge of each
refractory brick must resist change due to high temperature;
4,5,6
specimen or with a calibrated pyrometer.Arecording form
and the ability to withstand deformation or shape change when
of temperature indicator is recommended. If the optical pyrom-
subjected to significant loading at elevated temperatures is
eter is used, observations shall be made by sighting on the face
clearly demonstrated when refractory brick are subjected to
of the specimens and in the same relative positions as those
this test method.The test method is normally run at sufficiently
specified for the thermocouples.
high temperature to allow some liquids to form within the test
brick or to cause weakening of the bonding system. The result
5. Test Specimen
is usually a decrease in sample dimension parallel to the
5.1 The test specimen shall consist of a minimum of two 9
applied load and increase in sample dimensions perpendicular
1 1
by 4 ⁄2 by 2 ⁄2 or 3-in. (228 by 114 by 64 or 76-mm) straight
to the loading direction. Occasionally, shear fracture can occur.
refractory brick, or specimens of this size cut from larger
Since the test provides easily measurable changes in dimen-
shapes, utilizing as far as possible existing plane surfaces.
sions, prescribed limits can be established, and the test method
has been long used to determine refractory quality. The test
method has often been used in the establishment of written
3
Blueprints of detailed drawings of the furnaces shown in Figs. 1 and 2 are
specifications between producers and consumers.
available from ASTM. Request ADJC0016.
4
Method E 220 specifies calibration procedures for thermocouples.
5
The National Institutes of Standards andTechnology, Gaithersburg, MD 20899,
1
This test method is under the jurisdiction of ASTM Committee C08 on will, for a fee, furnish calibrations for radiation-type pyrometers and for thermo-
Refractories and is the direct responsibility of Subcommiteee C08.01 on Strength. couples.
6
Current edition approved Dec. 28, 1981. Published March 1982. Originally All temperatures specified in this test conform to the International Practical
e1
published as C 16 – 17 T. Last
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.