Fertilizers - Determination of trace elements - Determination of cadmium, chromium, lead and nickel by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after aqua regia dissolution

This European Standard specifies a method for the determination of the content of cadmium, chromium, nickel and lead in fertilizers with inductively coupled plasma atomic emission spectrometry (ICP-AES) after extraction with aqua regia. Limits of quantification are dependent on the sample matrix as well as on the instrument, but can roughly be expected to be 0,3 mg/kg for Cd and 1 mg/kg for Cr, Ni and Pb.
NOTE   Due to significant interference from Cu, Fe and Mn, no valid results can be reported using this method for fertilizer matrices containing high concentrations (>/= 10 %) of these micro-nutrients.

Düngemittel - Bestimmung von Elementspuren - Bestimmung von Cadmium, Chrom, Blei und Nickel mit Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-AES) nach Königswasseraufschluss

Diese Europäische Norm legt ein Verfahren zur Bestimmung des Gehalts an Cadmium, Chrom, Nickel und Blei in Düngemitteln mit Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-AES) nach Königswasseraufschluss fest. Die Bestimmungsgrenzen sind sowohl von der Probenmatrix als auch vom verwendeten Gerät abhängig, werden jedoch etwa bei 0,3 mg/kg für Cd und 1 mg/kg für Cr, Ni und Pb erwartet.
ANMERKUNG   Aufgrund signifikanter Störungen durch Cu, Fe und Mn können bei Anwendung dieses Verfahrens für Düngemittelmatrizes mit hohen Konzentrationen (≥ 10 %) dieser Spurennährstoffe keine zuverlässigen Ergebnisse ausgewiesen werden.

Engrais - Dosage des éléments trace - Détermination du cadmium, chrome, plomb et nickel par spectrométrie d'émission atomique avec plasma induit par haute fréquence (ICP-AES) après digestion à l'eau régale

La présente norme européenne spécifie une méthode permettant de déterminer la teneur en cadmium, chrome, nickel et plomb dans les engrais par spectrométrie d’émission atomique avec plasma à couplage inductif (ICP-AES) après extraction à l’eau régale. Les limites de quantification dépendent de la matrice de l’échantillon ainsi que de l’instrument, mais peuvent être attendues de l’ordre de 0,3 mg/kg pour Cd et 1 mg/kg pour Cr, Ni et Pb.
NOTE Du fait d’une interférence significative du Cu, Fe et Mn, aucun résultat valide ne peut être donné en utilisant cette méthode pour les matrices engrais contenants des concentrations élevés (≥ 10%) en ces oligo-éléments.

Gnojila - Določevanje elementov v sledovih - Določevanje kadmija, kroma, svinca in niklja z atomsko emisijsko spektrometrijo z induktivno sklopljeno plazmo (ICP-AES) po raztapljanju v zlatotopki

Ta evropski standard določa metodo za določevanje vsebnosti kadmija, kroma, niklja in svinca v gnojilih z atomsko emisijsko spektrometrijo z induktivno sklopljeno plazmo (ICP-AES) po ekstrakciji z zlatotopko. Meje kvantifikacije so odvisne od matrice vzorca in instrumenta, vendar za Cd običajno znašajo približno 0,3 mg/kg, za Cr, Ni in Pb pa 1 mg/kg.

General Information

Status
Withdrawn
Publication Date
22-Oct-2013
Withdrawal Date
22-Dec-2015
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
23-Dec-2015

Relations

Buy Standard

Standard
EN 16319:2013
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Düngemittel - Bestimmung von Elementspuren - Bestimmung von Cadmium, Chrom, Blei und Nickel mit Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-AES) nach KönigswasseraufschlussEngrais - Dosage des éléments traces - Détermination du cadmium, chromium, plomb et nickel par spectrométrie d'émission atomique avec plasma induit par haute fréquence (ICP-AES) après digestion à l'eau régaleFertilizers - Determination of trace elements - Determination of cadmium, chromium, lead and nickel by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after aqua regia dissolution65.080GnojilaFertilizersICS:Ta slovenski standard je istoveten z:EN 16319:2013SIST EN 16319:2013en,fr,de01-december-2013SIST EN 16319:2013SLOVENSKI
STANDARDSIST-TS CEN/TS 16319:20121DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16319
October 2013 ICS 65.080 Supersedes CEN/TS 16319:2012English Version
Fertilizers - Determination of trace elements - Determination of cadmium, chromium, lead and nickel by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after aqua regia dissolution
Engrais - Dosage des éléments trace - Détermination du cadmium, chrome, plomb et nickel par spectrométrie d'émission atomique avec plasma induit par haute fréquence (ICP-AES) après digestion à l'eau régale
Düngemittel - Bestimmung von Elementspuren - Bestimmung von Cadmium, Chrom, Blei und Nickel mit Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-AES) nach Königswasseraufschluss This European Standard was approved by CEN on 15 September 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16319:2013: ESIST EN 16319:2013

Results of the inter-laboratory test . 15 A.1 Inter-laboratory tests . 15 A.2 Statistical results for the determination of cadmium, chromium, lead and nickel . 15 Bibliography . 17
 the document has been editorially revised. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
≈ 1,18 g/ml. 6.3 Nitric acid, c(HNO3) = 16 mol/l; not less than 65 % volume fraction;
≈ 1,42 g/ml. SIST EN 16319:2013

6.4 Mixed solution of 0,8 mol/l nitric acid and 1,8 mol/l hydrochloric acid. Mix 150 ml of hydrochloric acid (6.2) and 50 ml nitric acid (6.3) to 1,0 l of water (6.1). 6.5 Standard stock solutions, cadmium, chromium, nickel and lead standard stock solutions, e.g.
= 1 000 mg/l for each element. Use suitable stock solutions. Both single-element stock solutions and multi-element stock solutions with adequate specification stating the acid used and the preparation technique are commercially available. It is recommended to use commercially available standard stock solutions for cadmium, chromium, nickel and lead. 6.6 Working standard solutions. Depending on the scope, different working standard solutions may be necessary. In general, when combining elements in working standard solutions, their chemical compatibility shall be regarded. Spectral interferences from other elements present in working standard solutions also need to be considered. Various combinations of elements at different concentrations may be used, provided that the standard stock solutions (6.5) are diluted with the same acid and in equal concentration as the acid in the test solution.
NOTE In equal concentrations (in mg/l), cadmium, chromium, nickel and lead are compatible in a multi-element standard solution for the determination by ICP-AES for this application. 6.6.1 Working standard solution I,
= 100 mg/l for cadmium, chromium, nickel and lead.
Dilute 10,0 ml of each standard stock solution of cadmium, chromium, nickel and lead (6.5) to 100,0 ml with the mixed acid solution (6.4) in the same 100 ml flask. If non-equal concentrations of cadmium, chromium, nickel and lead are needed, dilute the required volumes into 100,0 ml. This solution is used to prepare spiked test solutions and standard and calibration solutions. 6.6.2 Working standard solution II,
= 10 mg/l for cadmium, chromium, nickel and lead. Dilute 10,0 ml of the working standard solution I of cadmium, chromium, nickel and lead (6.6.1) to 100,0 ml with the mixed acid solution (6.4) in a 100 ml flask. If non-equal concentrations of cadmium, chromium, nickel and lead are needed, dilute the require volume from the standard stock solutions (6.5) into 100,0 ml. This solution is used to prepare spiked test solutions and calibration solutions. 7 Apparatus 7.1 Common laboratory glassware. 7.2 Analytical balance, capable of weighing to an accuracy of 1 mg. 7.3 Inductively coupled plasma-atomic emission spectrometer, with axial or radial viewing of the plas
...