(Main)Explosives for civil uses - Detonators and detonating cord relays - Part 7: Verification of pull-out resistance of detonators
Explosives for civil uses - Detonators and detonating cord relays - Part 7: Verification of pull-out resistance of detonators
This document specifies a method for determining the mechanical strength of electric detonators, electronic detonators and non-electronic detonators, leading wires/shock tubes, and their connections into the crimp/closure or sealing arrangement.
This method is applicable to explosives for civil uses.
Explosivstoffe für zivile Zwecke - Zünder und Sprengschnurverbinder - Teil 7: Bestimmung der mechanischen Festigkeit von Zünderdrähten, Zündschläuchen, Verbindungen, Anwürgungen und Verschlüssen
Dieses Dokument legt ein Verfahren für die Bestimmung der mechanischen Festigkeit von elektrischen Zündern, elektronischen und nichtelektrischen Zündern, Zünderdrähten/Zündschläuchen und deren Verbindungen über Anwürgungen/Verschlüsse oder Verschlussstopfen fest.
Dieses Verfahren gilt für Explosivstoffe für zivile Zwecke.
Explosifs à usage civil - Détonateurs et relais pour cordeau détonant - Partie 7 : Détermination de la force mécanique des fils d’amorce, tubes à transmission d’onde de choc, liaisons, sertissages et fermetures
Le présent document spécifie une méthode de détermination de la résistance mécanique des fils d’amorces/tubes à transmission d’onde de choc des détonateurs électriques, des détonateurs électroniques et des détonateurs non électroniques, et de leurs raccords situés dans le sertissage/la fermeture ou autre type de bouchon.
La présente méthode s’applique aux explosifs à usage civil.
Eksplozivi za civilno uporabo – Detonatorji in zakasnilniki – 7. del: Ugotavljanje mehanske trdnosti vodnikov, detonacijskih cevk, konektorjev, stisnjenih spojev in stisnitev
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2021
Eksplozivi za civilno uporabo – Detonatorji in zakasnilniki – 7. del: Ugotavljanje
mehanske trdnosti vodnikov, detonacijskih cevk, konektorjev, stisnjenih spojev in
stisnitev
Explosives for civil uses - Detonators and relays - Part 7: Determination of the
mechanical strength of leading wires, shock tubes, connections, crimps and closures
Explosivstoffe für zivile Zwecke - Zünder und Verzögerungselemente - Teil 7:
Bestimmung der mechanischen Festigkeit von Zünderdrähten, Zündschläuchen,
Verbindungen, Anwürgung und Verschluss
Explosifs à usage civil - Détonateurs et relais - Partie 7: Déterminationde la force
mécanique des fils d'amorçage, tubes à transmission d'onde de choc, liaisons,
sertissags et fermetures
Ta slovenski standard je istoveten z: prEN 13763-7
ICS:
71.100.30 Eksplozivi. Pirotehnika in Explosives. Pyrotechnics and
ognjemeti fireworks
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
prEN 13763-7
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2021
ICS 71.100.30 Will supersede EN 13763-7:2003
English Version
Explosives for civil uses - Detonators and detonating cord
relays - Part 7: Determination of the mechanical strength
of leading wires, shock tubes, connections, crimps and
closures
Explosifs à usage civil - Détonateurs et relais pour Explosivstoffe für zivile Zwecke - Zünder und
cordeau détonant - Partie 7: Détermination de la Sprengschnurverbinder - Teil 7: Bestimmung der
résistance mécanique des fils d'amorçage, tubes à mechanischen Festigkeit von Zünderdrähten,
transmission d'onde de choc, liaisons, sertissages et Zündschläuchen, Verbindungen, Anwürgung und
fermeture Verschlus
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 321.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13763-7:2021 E
worldwide for CEN national Members.
prEN 13763-7:2021 (E)
Contents Page
European foreword . 3
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Principle . 6
5 Apparatus . 6
)
6 Preparation and handling of test samples and test pieces . 7
6.1 Handling of test samples . 7
6.2 Electric detonators and electronic detonators with leading wires . 7
6.3 Non-electric detonators and electronic detonators with shock tube . 7
7 Procedure . 8
7.1 General. 8
7.2 Sudden release test . 8
7.2.1 Electric detonators and electronic detonators with leading wires . 8
7.2.2 Non-electric detonators and electronic detonators with shock tube . 8
7.3 Slow release test (electric detonators and electronic detonators with leading
wires) . 8
7.4 Functioning test after sudden release test . 8
8 Expression of results . 9
9 Test report . 9
Annex ZA (informative) Relationship between this European Standard and the essential
safety requirements of Directive 2014/28/EU relating to the making available on the
market and supervision of explosives for civil uses aimed to be covered . 10
Bibliography . 11
prEN 13763-7:2021 (E)
European foreword
This document (prEN 13763-7:2021) has been prepared by Technical Committee CEN/TC 321
“Explosives for civil uses”, the secretariat of which is held by UNE.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 13763-7:2003.
In comparison with the previous edition, the following technical modifications have been made:
a) Clause 1, Scope, has been revised:
1) it is now specified which detonators are covered by the document and electronic detonators have
been added;
2) it has been added that the document applies to explosives for civil uses;
b) Clause 4, Principle, has been added;
c) Clause 8, Expression of results, has been added;
d) Annex A, Range of applicability of the test method, has been removed;
e) Annex ZA has been added.
This document has been prepared under a Standardization Request (M/562) annexed to the Commission
Implementing Decision C(2019)6634 final as regards Explosives for civil uses given to CEN by the
European Commission and the European Free Trade Association, and supports Essential Safety
requirements of Directive 2014/28/EU.
For relationship with Directive 2014/28/EU, see informative Annex ZA, which is an integral part of this
document.
EN 13763, Explosives for civil uses — Detonators and detonating cord relays, is currently composed with
the following parts:
— Part 1: Requirements
— Part 2: Verification of thermal stability
— Part 3: Determination of sensitiveness to impact
— Part 4: Determination of resistance to abrasion of leading wires and shock tubes
— Part 5: Determination of resistance to cutting damage of leading wires and shock tubes
— Part 6: Determination of resistance to cracking in low temperatures of leading wires
— Part 7: Determination of the mechanical strength of leading wires, shock tubes, connections, crimps and
closures
— Part 8: Determination of resistance to vibration
prEN 13763-7:2021 (E)
— Part 9: Determination of resistance to bending of detonators
— Part 11: Determination of drop resistance of detonators and relays
— Part 12: Determination of resistance to hydrostatic pressure
— Part 13: Determination of resistance of electric detonator to electrostatic discharge
— Part 15: Determination of equivalent initiating capability
— Part 16: Determination of delay accuracy
— Part 17: Determination of no-fire current of electric detonators
— Part 18: Determination of series firing current of electric detonators
— Part 19: Determination of firing pulse of electric detonators
— Part 20: Determination of total resistance of electric detonators
— Part 21: Determination of flash-over voltage of electric detonators
— Part 22: Determination of capacitance, insulation resistance and insulation breakdown of leading wires
— Part 23: Determination of the shock-wave velocity of shock tube
— Part 24: Determination of the non-conductivity of shock tube
— Part 25: Determination of transfer capacity of relay and coupling accessories
— Part 26: Definitions, methods and requirements for devices and accessories for reliable and safe function
of detonators and relays
— Part 27: Definitions, methods and requirements for electronic initiation system
prEN 13763-7:2021 (E)
Introduction
During normal use on site, the crimps/closures of detonators and their leading wires or shock tubes can
be subjected to pulling forces. Such forces can cause a pull-out of internal components of the detonator.
For example:
— the shock tube can be pulled out of the detonator through the sealing plug;
— the leading wire, fuse head and sealing plug
...
Questions, Comments and Discussion