This European Standard specifies a method for accelerated wear and corrosion, to be used prior to the detection of nickel release from coated items that come into direct and prolonged contact with the skin.
Simulierte Abrieb- und Korrosionsprüfung zum Nachweis der Nickelabgabe von mit Auflagen versehenen Gegenständen
Méthode de simulation de l'usure et de la corrosion pour la détermination du nickel libéré par les objets revêtus
La présente Norme européenne spécifie une méthode d’usure et de corrosion accélérées à utiliser avant la détection du nickel libéré par les objets revêtus qui entrent en contact direct et prolongé avec la peau.
Simulirana obrabno-korozijska metoda za odkrivanje niklja iz prevlečenih predmetov
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.OHþHQLKSUHGPHWRYSimulierte Abrieb- und Korrosionsprüfung zum Nachweis der Nickelabgabe von mit Auflagen versehenen GegenständenMéthode de simulation de l'usure et de la corrosion pour la détermination du nickel libéré par les objets revêtusMethod for the simulation of wear and corrosion for the detection of nickel release from coated items39.060NakitJewelleryICS:Ta slovenski standard je istoveten z:EN 12472:2005+A1:2009SIST EN 12472:2006+A1:2009en,fr,de01-september-2009SIST EN 12472:2006+A1:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12472:2005+A1
June 2009 ICS 39.060 Supersedes EN 12472:2005English Version
Method for the simulation of wear and corrosion for the detection of nickel release from coated items
Méthode de simulation de l'usure et de la corrosion pour la détermination du nickel libéré par les objets revêtus
Simulierte Abrieb- und Korrosionsprüfung zum Nachweis der Nickelabgabe von mit Auflagen versehenen Gegenständen This European Standard was approved by CEN on 21 November 2005 and includes Amendment 1 approved by CEN on 21 May 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12472:2005+A1:2009: ESIST EN 12472:2006+A1:2009
Detailed examples of how to attach different types of items . 10 A.1 General . 10 A.2 Attachment of items with only one side in contact with the skin . 10 A.3 Spectacle frames . 10 A.4 Chains, watches, bracelets, rings etc. . 12 Bibliography . 14
This procedure attempts to simulate the wear and corrosion on a coated article during two years of normal use.
By its nature this is a pragmatic solution to the problems posed by the evaluation of coated items in contact with the skin, which may be subject to several kinds and varying degrees of wear. In order to show compliance with Directive 94/27/EC, items should be tested in accordance with the appropriate European harmonised standard(s), the references of which have been published by the European Commission in the Official Journal of the European Communities.
Currently, these are EN 1810, EN 1811 and this European Standard. SIST EN 12472:2006+A1:2009
The barrel is rotated so as to subject the test pieces to wear from the wear medium.
The items are then tested for nickel release in accordance with EN 1811. 4 Reagents and materials Except where indicated, all reagents and materials that can come into contact with samples or reagents shall be demonstrably free of nickel, and all reagents shall be of recognized analytical grade or better. 4.1 Corrosion 4.1.1 Container Container with a lid and a device for suspending the test pieces, all parts made of inert material (e.g. glass or plastic). SIST EN 12472:2006+A1:2009
Dimensions in millimetres
Key l length of barrel axis, as required a axis of rotation Figure 1 — View of tumbling barrel
4.2.2 Wear test apparatus A device capable of imparting to the barrel (4.2.1) a constant (30 ± 2) rotations per minute.
The device shall be capable of allowing the direction of rotation to be reversed. NOTE Information on sourcing suitable equipment is available from the CEN Management Centre. 4.2.3 Abrasive paste Abrasive paste produced fo
...