Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for establishing the performance

UAP of 4 months (TC Res 146c/1998) (CC/001115)
2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

Wärmeaustauscher - Flüssigkeitsgekühlte Kältemittelverflüssiger - Prüfverfahren zur Leistungsfeststellung

Echangeurs de chaleur - Condenseurs refroidis par un liquide - Procédures d'essais pour la détermination de la performance

Prenosniki toplote – Kondenzatorji hladiv, hlajeni s tekočino – Postopki preskušanja za ugotavljanje tehničnih karakteristik - Dopolnilo A1

General Information

Status
Published
Publication Date
22-Oct-2002
Withdrawal Date
29-Apr-2003
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
23-Oct-2002
Completion Date
23-Oct-2002

Relations

Overview

EN 1117:1998/A1:2002 is a CEN European standard that defines test procedures for establishing the performance of liquid‑cooled refrigerant condensers (heat exchangers). The amendment A1 (2002) updates the original 1998 standard to accommodate newer refrigerants (e.g., R404A, R407C, R410A) and adds clarifications and measurement requirements relevant for modern refrigerants and non‑azeotropic mixtures.

ICS classifications: 27.060.30 (Boilers and heat exchangers) and 27.200 (Refrigerating technology).

Key topics and technical requirements

  • Scope: Performance testing methodology for liquid‑cooled refrigerant condensers (condensers used in refrigeration systems).
  • Definitions added/clarified: condensing pressure, condensing (dew point) temperature, bubble point temperature, subcooling, superheat, oil content, and high glide refrigerants (defined as mixtures with >3 K difference between condensing and bubble point at 40 °C condensing temperature).
  • Standard capacity (Δt) values for common refrigerants (as specified in the amendment):
    • R134a: 25 K
    • R404A: 25 K
    • R407C: 35 K
    • R410A: 40 K
    • NH3: 50 K
  • Measurement and uncertainty:
    • Refrigerant mixture composition: 1% by mass uncertainty for each refrigerant component.
    • For high‑glide (non‑azeotropic) refrigerants, the mixture shall be measured unless the mass fraction is guaranteed to vary by less than 2% from manufacturer data.
  • Test arrangement and equipment:
    • Ensure free drainage of liquid refrigerant to the liquid receiver.
    • Prevent accumulation of liquid refrigerant in the cycle for non‑azeotropic refrigerants.
    • Do not modify the liquid flow through the condenser under test.
    • Air recirculation should be treated the same way as in normal operation (neither artificially created nor prevented).
    • For high‑glide refrigerants the liquid receiver internal volume shall be < 4% of the total system volume.
  • Manufacturer data: amendment removes previous requirement for correction factors for other refrigerants.

Practical applications

  • Standardizes how condenser performance is measured for product rating, certification and comparative testing.
  • Ensures test labs and manufacturers produce comparable, repeatable performance data for condensers using modern refrigerants.
  • Guides HVAC‑R engineers and test rig designers on instrumentation, measurement uncertainty, and setup requirements-especially important when testing non‑azeotropic (high‑glide) refrigerant mixtures.
  • Useful for compliance testing, product datasheets, and evaluation during design validation or R&D.

Who should use this standard

  • Heat‑exchanger and condenser manufacturers
  • Independent testing laboratories and certification bodies
  • HVAC‑R design and performance engineers
  • Product compliance and quality assurance teams
  • Standards bodies and technical committees (CEN/TC 110)

Related standards

  • Other CEN standards on heat exchangers and refrigerating technology (refer to CEN/TC 110 for related normative references and national implementations).

Keywords: EN 1117, liquid‑cooled refrigerant condensers, heat exchangers, test procedures, condensing pressure, bubble point, high glide refrigerants, R407C, R410A, measurement uncertainty.

Amendment
EN 1117:1999/A1:2004
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 1117:1998/A1:2002 is a amendment published by the European Committee for Standardization (CEN). Its full title is "Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for establishing the performance". This standard covers: UAP of 4 months (TC Res 146c/1998) (CC/001115) 2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

UAP of 4 months (TC Res 146c/1998) (CC/001115) 2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

EN 1117:1998/A1:2002 is classified under the following ICS (International Classification for Standards) categories: 27.060.30 - Boilers and heat exchangers; 27.200 - Refrigerating technology. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1117:1998/A1:2002 has the following relationships with other standards: It is inter standard links to EN 1117:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 1117:1998/A1:2002 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2004
3UHQRVQLNLWRSORWH±.RQGHQ]DWRUMLKODGLYKODMHQLVWHNRþLQR±3RVWRSNL
SUHVNXãDQMD]DXJRWDYOMDQMHWHKQLþQLKNDUDNWHULVWLN'RSROQLOR$
Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for
establishing the performance
Wärmeaustauscher - Flüssigkeitsgekühlte Kältemittelverflüssiger - Prüfverfahren zur
Leistungsfeststellung
Echangeurs de chaleur - Condenseurs refroidis par un liquide - Procédures d'essais pour
la détermination de la performance
Ta slovenski standard je istoveten z: EN 1117:1998/A1:2002
ICS:
27.060.30 Grelniki vode in prenosniki Boilers and heat exchangers
toplote
27.200 Hladilna tehnologija Refrigerating technology
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 1117:1998/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2002
ICS 27.060.30; 27.200
English version
Heat exchangers - Liquid cooled refrigerant condensors - Test
procedures for establishing the performance
Echangeurs de chaleur - Condenseurs refroidis par un Wärmeaustauscher - Flüssigkeitsgekühlte
liquide - Procédures d'essais pour la détermination de la Kältemittelverflüssiger - Prüfverfahren zur
performance Leistungsfeststellung
This amendment A1 modifies the European Standard EN 1117:1998; it was approved by CEN on 14 September 2002.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this
amendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references concerning such
national standards may be obtained on application to the Management Centre or to any CEN member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2002 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1117:1998/A1:2002 E
worldwide for CEN national Members.

Contents
page
Foreword.3
3 Definitions.3
4 Symbols .4
5 Standard capacity .4
6 Manufacturer's data .5
7 Measurements.5
8 Testing methods and equipment.5
Foreword
This document (EN 1117:1998/A1:2002) has been prepared by Technical Committee CEN /TC 110 "Heat
exchangers", the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by April 2003, and conflicting national standards shall be withdrawn at the latest by
April 2003.
This amendment is introduced to accommodate newly available refrigerants such as R404A, R407C and R410A.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Iceland, Irelan
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...