EN 14212:2024/prA1
(Amendment)Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
- Abstract
This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing.
NOTE 1 It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2 When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about:
— type testing conditions, test procedures and test requirements;
— analyser performance requirements;
— evaluation of the type testing results;
— evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about:
— initial installation of the analyser in the monitoring network and acceptance testing;
— ongoing quality assurance/quality control;
— calculation and reporting of measurement results;
— evaluation of the uncertainty of the measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
- Status
- Not Published
- Publication Date
- 03-Aug-2028
- Technical Committee
- CEN/TC 264 - Air quality
- Current Stage
- 4020 - Submission to enquiry - Enquiry
- Start Date
- 22-Oct-2026
- Due Date
- 23-Apr-2027
- Completion Date
- 22-Oct-2026
EN 14212:2024/prA1 is a draft CEN amendment to EN 14212:2024 for measuring sulfur dioxide in ambient air by ultraviolet fluorescence. It updates the European method used for continuous monitoring, type testing, installation checks, and uncertainty evaluation for fixed-site analysers.
The amendment is aimed at ambient air monitoring practice, especially where results are used for regulatory air-quality work. It tightens and clarifies parts of the standard that affect analyser selection, calibration, routine quality control, and reported measurement uncertainty.
What does EN 14212:2024/prA1 specify?
EN 14212:2024/prA1 specifies changes to the European standard for continuous sulfur dioxide measurement in ambient air using the ultraviolet fluorescence principle. It modifies the scope, definition of ambient air, performance criteria, sampling hardware, routine checks, type testing, and uncertainty calculations used with EN 14212:2024.
The amendment is organised as a foreword followed by 22 targeted modifications. These changes touch Clauses 1, 3, 5.2, 6.3.2, 6.5, 8.2, 8.4.6, 9.4.2, 9.5.4, 9.5.5, 9.6.1.2, 9.7.1, A.1, D.1, E.2 to E.5, F.2, G.2, and H.3.5.5.
What are the key requirements of EN 14212:2024/prA1?
EN 14212:2024/prA1 mainly corrects how the base method is applied and evaluated in practice. The most important effect is that it updates the technical rules used to judge analyser suitability and measurement quality.
Scope and applicability
- Clause 1 removes an obsolete note about older reference analysers.
- The scope still frames the method as a continuous ultraviolet fluorescence measurement for sulfur dioxide in ambient air, with use in rural, urban-background, traffic-influenced, and industrial-influenced locations.
In practice, this keeps the method focused on fixed-site ambient air monitoring and on comparability between analysers.
Definition and sampling details
- Clause 3 revises the definition of ambient air so it excludes workplaces as defined by Directive 89/654/EEC.
- Clause 6.3.2 updates the particle filter material to 316 L stainless steel.
- Clause 6.5 revises the sampling-pump-to-manifold requirement and tightens the leakage wording.
In practice, these changes affect where the method applies and how the sampling train is built and checked.
Performance and linearity checks
- Clause 5.2 updates the formula used for relevant performance characteristics and criteria.
- Clause 8.2 updates Table 1 performance criteria, including residual at zero and drift requirements.
- Clause 8.4.6 revises the linearity test sequence and the tolerance used when applying test concentrations.
In practice, laboratories and manufacturers must use the revised performance checks when demonstrating that an analyser meets the method.
Routine monitoring and quality assurance
- Clause 9.4.2 updates the routine schedule for calibration, checks, and maintenance.
- Clause 9.5.4 is deleted.
- Clause 9.5.5 removes one data-treatment reference after a performance exceedance.
- Clause 9.6.1.2 updates the action criteria for zero drift.
- Clause 9.7.1 adds an action criterion for particle-filter changes.
In practice, network operators need to follow the revised maintenance and intervention rules to keep data valid.
Type testing and uncertainty
- Annex E updates type-testing requirements, analyser availability, and the uncertainty calculation basis.
- Annex F and Annex G revise the combined standard uncertainty formulas.
- Annex H updates the uncertainty term linked to electrical voltage variations.
In practice, test houses and laboratories must use the revised calculation paths when qualifying analysers and reporting uncertainty.
What terms does EN 14212:2024/prA1 define?
- Ambient air - outdoor air in the troposphere, excluding workplaces as defined by Directive 89/654/EEC, and not regularly accessible to the public.
- Ultraviolet fluorescence analyser - the analyser type used by the standard to measure sulfur dioxide through the ultraviolet fluorescence principle.
- Type testing - the evaluation used to decide whether an analyser meets the method's selection and performance criteria.
- Fixed site - the monitoring location where the analyser is assessed for practical use in a network.
- Zero and span checks - routine checks used to confirm that the analyser stays within its expected response range.
- Quality assurance/quality control (QA/QC) - the ongoing checks, calibration, and maintenance used during routine monitoring.
- Combined standard uncertainty - the uncertainty value calculated by combining the listed contributors in the annex formulas.
Who uses EN 14212:2024/prA1?
EN 14212:2024/prA1 is used by air-quality monitoring networks, environmental laboratories, test houses, analyser manufacturers, and technical staff who install or maintain sulfur dioxide analysers. It is also relevant to procurement teams and quality managers who need to specify, test, accept, or audit UV fluorescence equipment for ambient air monitoring.
It matters most for work linked to regulated ambient air measurements in rural, urban-background, traffic, and industrial settings.
What changed in EN 14212:2024/prA1 from the previous edition?
EN 14212:2024/prA1 is a draft amendment to EN 14212:2024, and it is described as addressing critical errors in that edition. The amendment revises the scope note, the definition of ambient air, several performance criteria and test procedures, routine maintenance and filter-change rules, and the uncertainty equations in Annexes F, G, and H.
Which standards are used with EN 14212:2024/prA1?
EN 14212:2024/prA1 modifies EN 14212:2024, which is the base European Standard for sulfur dioxide measurement by ultraviolet fluorescence. The text also cites Council Directive 2008/50/EC for the air-quality context, and Directive 89/654/EEC in the revised definition of ambient air.
What does the EN 14212:2024/prA1 document contain?
The amendment contains revised wording for the scope and definition clauses, plus updated technical text in the measurement, sampling, testing, and uncertainty sections. It also updates formulas and tables in the annexes that support regression, test-gas application, type testing, and uncertainty calculation.
For users, the most important parts are the revised performance criteria in Clause 8, the revised monitoring practice in Clause 9, and the annex updates that affect how results are checked and justified. This is the material a laboratory, network operator, or test house would use when aligning equipment, procedures, and reported data with the amended standard.
Relations
- Effective Date
- 03-Jun-2026
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
EN 14212:2024/prA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence". This standard covers: This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing. NOTE 1 It is possible to use other ranges depending on the levels present in ambient air. NOTE 2 When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply. The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa). NOTE 3 1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2. This document contains information for different groups of users. Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about: — type testing conditions, test procedures and test requirements; — analyser performance requirements; — evaluation of the type testing results; — evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results. Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about: — initial installation of the analyser in the monitoring network and acceptance testing; — ongoing quality assurance/quality control; — calculation and reporting of measurement results; — evaluation of the uncertainty of the measurement results under practical monitoring conditions. This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document. NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid. NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing. NOTE 1 It is possible to use other ranges depending on the levels present in ambient air. NOTE 2 When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply. The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa). NOTE 3 1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2. This document contains information for different groups of users. Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about: — type testing conditions, test procedures and test requirements; — analyser performance requirements; — evaluation of the type testing results; — evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results. Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about: — initial installation of the analyser in the monitoring network and acceptance testing; — ongoing quality assurance/quality control; — calculation and reporting of measurement results; — evaluation of the uncertainty of the measurement results under practical monitoring conditions. This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document. NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid. NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
EN 14212:2024/prA1 is classified under the following ICS (International Classification for Standards) categories: 13.040.20 - Ambient atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 14212:2024/prA1 has the following relationships with other standards: It is inter standard links to EN 14212:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 14212:2024/prA1 is associated with the following European legislation: EU Directives/Regulations: 2008/50/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 14212:2024/prA1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2026
Zunanji zrak - Standardna metoda za določanje koncentracije žveplovega dioksida
z ultravijolično fluorescenco - Dopolnilo A1
Ambient air - Standard method for the measurement of the concentration of sulphur
dioxide by ultraviolet fluorescence
Außenluft - Messverfahren zur Bestimmung der Konzentration von Schwefeldioxid mit
Ultraviolett-Fluoreszenz Außenluft - Messverfahren zur Bestimmung der Konzentration
von Schwefeldioxid mit Ultraviolett-Fluoreszenz
Air ambiant - Méthode normalisée pour le mesurage de la concentration en dioxyde de
soufre par fluorescence U.V.
Ta slovenski standard je istoveten z: EN 14212:2024/prA1
ICS:
13.040.20 Kakovost okoljskega zraka Ambient atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 14212:2024
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
October 2026
ICS 13.040.20
English Version
Ambient air - Standard method for the measurement of the
concentration of sulphur dioxide by ultraviolet
fluorescence
Air ambiant - Méthode normalisée pour le mesurage de Außenluft - Messverfahren zur Bestimmung der
la concentration en dioxyde de soufre par fluorescence Konzentration von Schwefeldioxid mit Ultraviolett-
U.V. Fluoreszenz Außenluft - Messverfahren zur
Bestimmung der Konzentration von Schwefeldioxid
mit Ultraviolett-Fluoreszenz
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 264.
This draft amendment A1, if approved, will modify the European Standard EN 14212:2024. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14212:2024/prA1:2026 E
worldwide for CEN national Members.
EN 14212/prA1:2026 (E)
Contents Page
European foreword . 3
1 Modification to Clause 1 ”Scope” . 4
2 Modification to Clause 3 “Terms and definitions” . 4
3 Modification to 5.2, “Relevant performance characteristics and criteria” . 4
4 Modification to 6.3.2, “Particle filter”, Note 2 . 4
5 Modifications to 6.5 “Sampling pump to manifold” . 4
6 Modifications to 8.2, “Relevant performance characteristics and criteria” . 5
7 Modification to 8.4.6, “Lack of fit of linearity of the calibration function” . 5
8 Modification to 9.4.2, ‘Frequency of calibrations, checks and maintenance’ . 5
9 Modification to 9.5.4, “Testing the sampling system” . 6
10 Modification to 9.5.5 (9.5.4), “Treatment of data after exceedance of performance
criteria . 6
11 Modification to 9.6.1.2, “Performance of zero and span checks” . 6
12 Modification to 9.7.1, “Change of particle filters”. 6
13 Modification to A.1, “Establishment of the regression line” . 6
14 Modifications to D.1, “Procedure for applying test gas” . 7
15 Modification to E.2, “Type testing Requirement a)” . 7
16 Modification to E.3, “Type tesing Requirement b)” . 7
17 Modification to E.3.2.5.9, “Calibration gas” . 8
18 Modification to E.4, “Type testing Requirement c)” . 8
19 Modification to E.5, “Type testing Requirement d)”, Table E.6 . 8
20 Modification to F.2, “Combined standard uncertainty”. 9
21 Modification to H.3.5.5, “Electrical voltage” . 9
22 Modification to G.2, “Combined standard uncertainty” . 9
European foreword
This document (EN 14212:2024/prA1:2026) has been prepared by Technical Committee CEN/TC 264
“Air quality”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This amendment addresses only the critical errors identified in the EN 14212:2024. Errors considered as
minor by CEN/TC 264/WG 12 will be addressed in the subsequent revision of EN 14212.
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association, and supports essential requirements of
EU Directive(s) / Regulation(s).
1 Modification to Clause 1 ”Scope”
Remove the following sentence from NOTE 4:
“As newer versions of analysers tested under this document become available, discontinue the use of
older reference analysers.”.
2 Modification to Clause 3 “Terms and definitions”
Replace definition 3.2 ambient air:
“3.2
ambient air
outdoor
...