EN ISO 11609:2026
(Main)Dentistry - Dentifrices - Requirements, test methods and marking (ISO 11609:2026)
- Abstract
This document specifies requirements for the physical and chemical properties of dentifrices and provides guidelines for suitable test methods. It also specifies requirements for the marking, labelling and packaging of dentifrices.
This document is applicable to dentifrices, including toothpastes, destined to be used by consumers on a daily basis with a toothbrush to promote oral hygiene.
This document does not apply to specific qualitative and quantitative requirements for freedom from biological and toxicological hazards. These are covered in ISO 7405 and ISO 10993-1.
- Status
- Published
- Publication Date
- 04-Aug-2026
- Technical Committee
- CEN/TC 55 - Dentistry
- Drafting Committee
- CEN/TC 55 - Dentistry
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 05-Aug-2026
- Due Date
- 05-Aug-2026
- Completion Date
- 05-Aug-2026
EN ISO 11609:2026 is a European Standard published by CEN for dentifrices, including toothpastes, used daily with a toothbrush. It specifies physical and chemical requirements, gives guidance on suitable test methods, and covers marking, labelling, and packaging for products intended to promote oral hygiene. The standard is aimed at manufacturers, laboratories, and others who need to check composition, stability, abrasivity, and label information for consumer dentifrices.
What does EN ISO 11609:2026 specify?
EN ISO 11609:2026 applies to dentifrices for daily consumer use with a toothbrush. It sets product requirements and points to test methods that can be used to check those requirements.
The scope excludes specific qualitative and quantitative requirements for freedom from biological and toxicological hazards; those are addressed in ISO 7405 and ISO 10993-1. The document is organized into clauses 1 to 7, followed by three informative annexes and a bibliography.
| Annex | What it covers |
|---|---|
| Annex A | Abrasivity test procedure using the American Dental Association (ADA) method |
| Annex B | Relative dentifrice abrasivity to enamel and dentine by surface profile method, including RDA-PE and REA-PE |
| Annex C | Testing total fluoride in dentifrices, including two fluoride analysis methods |
What are the key requirements of EN ISO 11609:2026?
EN ISO 11609:2026 focuses on composition limits, test methods, and product information that matter in everyday manufacture and quality control. The main practical point is that a dentifrice has to stay within defined limits for fluoride, impurities, pH, abrasivity, stability, and carbohydrate content, and then be labelled and packaged in a way that matches those properties.
Composition and product limits
- Clause 4.1 - Total fluoride. The total fluoride concentration must not exceed a mass fraction of 0.15%, and a single-unit container must not contain more than 300 mg total fluoride. In practice, this is the main control for fluoride dose and consumer exposure.
- Clause 4.2 - Heavy metals (elemental impurities). The total maximum concentration of heavy metals must not exceed 20 mg/kg. The clause points to ISO 21392 for antimony, arsenic, cadmium, lead, mercury, and other elemental impurities, which matters for raw-material control and finished-product verification.
- Clause 4.3 - pH. When tested according to the document, the dentifrice must have a pH below 10.5. This gives formulators a clear upper limit to check product compatibility and consistency.
- Clause 4.4 - Microbiology. Microbiological contamination has to be tested, using suitable validated methods. For manufacturers, this means hygiene control and routine microbiological assessment are expected parts of product release.
- Clause 4.5 - Abrasivity. Dentine abrasivity must not exceed 2.5 times the primary reference material, and enamel abrasivity must not exceed 4.0 times the primary reference material. This matters because abrasivity is linked to how the product interacts with tooth surfaces in use.
- Clause 4.6 - Stability. The product must not deteriorate in a way that affects compliance or creates toxicological hazards after ageing or after 30 months at room temperature. If deterioration is detected, the dentifrice needs an expiry date.
- Clause 4.7 - Readily fermentable carbohydrates. The dentifrice must not contain readily fermentable carbohydrates. In practice, this supports control of formulations intended for oral hygiene use.
Test methods
- Clause 5.1 - pH test. The pH is measured in a suspension made from one part dentifrice and three parts water for analytical laboratory use in accordance with ISO 3696, with the measurement taken within 10 minutes. This gives a simple, repeatable check of the finished product.
- Clauses 5.2 and 5.3 - Abrasivity testing. Dentine and enamel abrasivity are determined as mean relative abrasivity against a primary reference sample or a calibrated reference material. Annex A or Annex B may be used, so labs can choose between the radio-tracer and profilometry approaches if they are validated.
- Clause 5.4 - Stability testing. One ageing option stores the product in its original container at 40 °C and 75% relative humidity for 3 months, or under equivalent conditions that simulate 30 months at room temperature. This is the basis for shelf-life checks and expiry-date decisions.
Marking, labelling, and packaging
- Clause 6 - Marking and labelling. For primary containers other than small single units under 10 ml, the label has to include the product name, trade name, manufacturer or responsible distributor, a tracking code with an intelligible production date, a complete ingredient list using INCI, fluoride content and type if present, net volume or mass, an expiry date when shelf life is less than 30 months, and a safety notice for children under 6 years when fluoride is 1 000 µg/g or more. This clause is the main link between formulation data and consumer-facing information.
- Clause 7 - Packaging. Packaging and the dispensing system must prevent contamination under normal handling and transport, including after ageing. For manufacturers, this means the container system has to protect the product through its declared shelf life.
What terms does EN ISO 11609:2026 define?
EN ISO 11609:2026 uses a short set of core terms that set the product boundary clearly.
- Dentifrice - A substance or mixture prepared for consumers to clean accessible tooth surfaces and surrounding tissues for hygiene purposes.
- Toothpaste - A semi-solid dentifrice supplied as a paste, cream, or gel, typically containing abrasives, humectants, binders, surfactants, flavourings, fluorides, and other oral-health ingredients.
- Single-unit container - A container of dentifrice sold to an individual consumer.
- Primary container - The container that is in direct contact with the product.
Who uses EN ISO 11609:2026?
EN ISO 11609:2026 is used by dentifrice manufacturers, toothpaste formulators, and quality control laboratories that need to verify fluoride content, pH, microbiology, abrasivity, and stability. It is also relevant to packaging and labelling teams because the clause on marking and labelling is specific about what must appear on the primary container.
Buyers, technical evaluators, and compliance teams in oral care and toiletries use it to compare products against a common technical basis. Responsible distributors and testing laboratories also use it when they need to document product identity, shelf life, and analytical results.
What changed in EN ISO 11609:2026 from the previous edition?
EN ISO 11609:2026 supersedes EN ISO 11609:2017. The foreword states that this fourth edition includes edits and clarifications aligned with ISO directives, updates for abrasive availability, corrections for contacting the manufacturer of the cross-brushing machine, a correction to Clause 2 and the bibliography, and a modification to Clause 4.2 that suggests ISO 21392 for analysis of five elemental impurities.
Which standards are used with EN ISO 11609:2026?
EN ISO 11609:2026 relies on several referenced standards and companion documents for vocabulary, test media, dating, analytical methods, microbiology, and safety evaluation.
| Reference | What it contributes |
|---|---|
| ISO 1942 | Dentistry vocabulary used in the terms and definitions clause |
| ISO 3696 | Water quality for the pH test |
| ISO 8601-1 and ISO 8601-2 | Date format for expiry-date marking |
| ISO 19448 | Fluoride analysis by fluoride ion-selective electrode in Annex C |
| ISO 21392 | Trace metal analysis for elemental impurities |
| ISO 7405 and ISO 10993-1 | Biological and toxicological hazard evaluation outside the scope of this document |
| ISO 16212, ISO 18416, ISO 21148, ISO 21149, ISO 21150, ISO 22717, ISO 22718, ISO 29621 | Microbiological examination and risk assessment methods |
| ISO 5725-1 to ISO 5725-6 | Accuracy, trueness, precision, and collaborative study principles used in abrasivity work |
The document also uses the International Nomenclature of Cosmetic Ingredients (INCI) for ingredient listing on labels.
What does the EN ISO 11609:2026 document contain?
EN ISO 11609:2026 contains product requirements in Clause 4, test methods in Clause 5, and marking, labelling, and packaging rules in Clauses 6 and 7. Its annexes give the detailed procedures behind the main performance checks rather than repeating them in a short form.
Annex A sets out an ADA brushing-based abrasivity method with specimen preparation, reference materials, counting approach, and calculation steps. Annex B gives a profilometry-based route for relative dentifrice abrasivity, including specimen preparation, brushing conditions, proportional-linearity checks, and calculation of RDA-PE and REA-PE. Annex C provides two total fluoride methods, one based on an ADA diffusion approach and one based on IS 6356, both intended for analytical control of fluoride-containing dentifrices.
Relations
- Effective Date
- 18-Jan-2023
- Effective Date
- 12-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.

Intertek Bangladesh
Intertek certification and testing services in Bangladesh.
Sponsored listings
Frequently Asked Questions
EN ISO 11609:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Dentistry - Dentifrices - Requirements, test methods and marking (ISO 11609:2026)". This standard covers: This document specifies requirements for the physical and chemical properties of dentifrices and provides guidelines for suitable test methods. It also specifies requirements for the marking, labelling and packaging of dentifrices. This document is applicable to dentifrices, including toothpastes, destined to be used by consumers on a daily basis with a toothbrush to promote oral hygiene. This document does not apply to specific qualitative and quantitative requirements for freedom from biological and toxicological hazards. These are covered in ISO 7405 and ISO 10993-1.
This document specifies requirements for the physical and chemical properties of dentifrices and provides guidelines for suitable test methods. It also specifies requirements for the marking, labelling and packaging of dentifrices. This document is applicable to dentifrices, including toothpastes, destined to be used by consumers on a daily basis with a toothbrush to promote oral hygiene. This document does not apply to specific qualitative and quantitative requirements for freedom from biological and toxicological hazards. These are covered in ISO 7405 and ISO 10993-1.
EN ISO 11609:2026 is classified under the following ICS (International Classification for Standards) categories: 71.100.70 - Cosmetics. Toiletries; 97.170 - Body care equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 11609:2026 has the following relationships with other standards: It is inter standard links to EN ISO 11609:2017, ISO 11609:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 11609:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 dentifrice
- 3.2 toothpaste
- 3.3 single-unit container
- 3.4 primary container
- 4 Requirements relative to the physical and chemical properties of dentifrices
- 4.1 Total fluoride
- 4.2 Heavy metals (elemental impurities)
- 4.4 Microbiology
- 4.5 Abrasivity
- 4.6 Stability
- 4.7 Readily fermentable carbohydrates
- 5 Test methods
- 5.1 Determination of pH
- 5.2 Determination of dentine abrasivity
- 5.3 Determination of enamel abrasivity
- 5.4 Determination of stability
- 6 Marking and labelling
- 7 Packaging
- Annex A
- Annex B
- Annex C
- Bibliography
Introduction
Dentifrices are not expected to cause adverse reactions to oral soft tissue when used in accordance with the manufacturer's recommendation for frequency and duration of use, nor cause any known side effects. Guidelines on assessing the claimed or implied efficacy of dentifrices for the prevention or control of oral conditions can be found through Reference [19], Reference [20] and Reference [21].
SIST EN ISO 11609:2026
SIST EN ISO 11609:2026 International Standard ISO 11609:2026(en) Dentistry — Dentifrices — Requirements, test methods and marking
1 Scope
This document specifies requirements for the physical and chemical properties of dentifrices and provides guidelines for suitable test methods. It also specifies requirements for the marking, labelling and packaging of dentifrices.
This document is applicable to dentifrices, including toothpastes, destined to be used by consumers on a daily basis with a toothbrush to promote oral hygiene.
This document does not apply to specific qualitative and quantitative requirements for freedom from biological and toxicological hazards. These are covered in ISO 7405 and ISO 10993-1.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1942, Dentistry — Vocabulary ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 8601-1, Date and time — Representations for information interchange — Part 1: Basic rules ISO 8601-2, Date and time — Representations for information interchange — Part 2: Extensions International Nomenclature of Cosmetic Ingredients (INCI), in International Cosmetic Ingredient Dictionary 1) and Handbook
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 1942 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 dentifrice
substance or combination of substances specially prepared for consumers for hygiene of the accessible surfaces of teeth and surrounding tissues 1) Nomenclature developed by the Personal Care Products Council (formerly CTFA). Available at: https:// access .personalcarecouncil .org/ eweb/ DynamicPage .aspx ?Site = pcpc & WebKey = 4513b14e -2f75 -4857 -85b4 -b3697be5d5d9.
SIST EN ISO 11609:2026 ISO 11609:2026(en)
3.2 toothpaste
semi-solid dentifrice preparation presented in the form of a paste, cream or gel Note 1 to entry: The product’s common constituents are abrasives, humectants, binders, surfactants, flavourings, fluorides and other agents for oral health benefits.
3.3 single-unit container
container of dentifrice marketed to individual consumers
3.4 primary container
container that is in direct contact with the product
4 Requirements relative to the physical and chemical properties of dentifrices
4.1 Total fluoride
4.1.1 Total fluoride concentration
The total fluoride concentration shall not exceed a mass fraction of 0,15 %. For an example method, see Annex C.
Other validated methods of similar sensitivity and accuracy may be used (see References [22] to [31]).
4.1.2 Total fluoride in a single-unit container
The amount of total fluoride in a single-unit container shall not exceed 300 mg. This requirement does not apply to containers of dentifrice to be dispensed under professionally supervised conditions or in community-based caries prevention programmes, e.g. school toothbrushing programmes.
4.2 Heavy metals (elemental impurities)
The total maximum concentration of heavy metals shall not exceed 20 mg/kg. See ISO 21392 for antimony, arsenic, cadmium, lead or mercury and for other elemental impurities. The methods described in References [32] and [33], or another validated method of similar sensitivity and accuracy, may be used.
4.3 pH When tested in accordance with 5.1, the dentifrice shall have a pH below 10,5.
4.4 Microbiology
Testing for microbiological contamination shall be carried out. For some methods, see ISO 16212, ISO 18416, ISO 21148, ISO 21149, ISO 21150, ISO 22717, ISO 22718 and ISO 29621 or any other validated method of equivalent sensitivity, accuracy and specificity.
4.5 Abrasivity
The abrasivity of the dentifrice shall not exceed the following limit for dentine:
- 2,5 times that of the primary reference material (see the procedure specified in Annex A or Annex B).
SIST EN ISO 11609:2026 ISO 11609:2026(en) The abrasivity of the dentifrice shall not exceed the following limit for enamel:
- 4,0 times that of the primary reference material (see the procedure specified in Annex A or Annex B). NOTE Abrasivity values below the limits specified in this document are not intended to be used to rank the safety of dentifrices. All dentifrices beneath the abrasivity limits are recognized as safe with respect to their abrasion of human hard tissues.
Test in accordance with 5.2 or 5.3 or any other validated method of similar sensitivity and accuracy. When an alternative abrasivity reference to the primary reference material (calcium pyrophosphate) is used, traceability to the primary reference material shall be maintained by the testing laboratory. When any alternative abrasivity reference is used, the results shall be reported with respect to the original primary reference material (calcium pyrophosphate).
4.6 Stability
The dentifrice shall show no deterioration that can affect conformity with this document or can result in toxicological hazards after being subjected to one of the ageing procedures specified in 5.4 or after 30 months of storage at room temperature. If deterioration is detected, the dentifrice shall be labelled with an expiry date.
4.7 Readily fermentable carbohydrates
The dentifrice shall not contain readily fermentable carbohydrates. Conformity shall be established by the absence of such compounds in the complete formula or by performing tests in accordance with commonly used analytical methods.
5 Test methods
5.1 Determination of pH
Suspend one part by mass of the dentifrice into three parts by mass of water for analytical laboratory use in accordance with ISO 3696 (grade 3). Determine the pH of the suspension within 10 min, using a pH-meter and electrode assembly.
5.2 Determination of dentine abrasivity
Determine the mean relative abrasivity compared to the primary reference sample or any other reference material calibrated to the primary reference sample for human dentine. One of the methods specified in Annex A or Annex B may be used. Other validated measurement methods on dentine of similar sensitivity and accuracy may be used. Conforming principles can be found in ISO 5725-1, ISO 5725-2, ISO 5725-3, ISO 5725-4, ISO 5725-5, and ISO 5725-6. For other references, see, for example, References [34] and [35].
5.3 Determination of enamel abrasivity
Determine the mean relative abrasivity compared to the primary reference sample, or any other reference material calibrated to the primary reference sample for human enamel. One of the methods specified in Annex A or Annex B or another validated measurement method on enamel of similar sensitivity and accuracy may be used. Principles can be found in ISO 5725-1, ISO 5725-2, ISO 5725-3, ISO 5725-4, ISO 5725-5, and ISO 5725-6. For other references, see, for example, References [34] and [35].
5.4 Determination of stability
For the accelerated ageing procedure, the dentifrice shall be stored in its original container at 40 °C ± 2 °C at 75 % ± 5 % relative humidity for 3 months or at such conditions of time and temperature as will simulate storage at room temperature for 30 months, see Reference [36]. Following storage, test the product according to this document.
SIST EN ISO 11609:2026 ISO 11609:2026(en)
6 Marking and labelling
With the exception of small single units (less than 10 ml), all primary containers shall be marked with the following information:
a) the word “dentifrice” or equivalent; b) the trade name; c) the name and contact information of the manufacturer or responsible distributor; d) the tracking code that includes an intelligible production date; e) a complete list of ingredients according to the International Nomenclature of Cosmetic Ingredients (INCI); f) the concentration and type of fluoride, if present, expressed in micrograms per gram, or percent by mass, or both; g) the net volume, in millilitres, or net mass in grams, or both; h) the expiry date, expressed in accordance with ISO 8601-1 and ISO 8601-2, if the period of stability (shelflife) is less than 30 months; i) a safety notice regarding the use, by children below 6 years of age, of dentifrices containing concentrations of fluoride of 1 000 µg/g or more.
7 Packaging
The product shall be packaged in such a way that under normal conditions of handling and transport, the container or dispensing system, or both, shall not contaminate or permit contamination of the dentifrice inside, so as to affect its conformity with this document, after being subjected to the ageing procedure described in 5.4.
SIST EN ISO 11609:2026 ISO 11609:2026(en)
Annex A
(informative)
Abrasivity test procedure — American Dental Association (ADA) method A.1 General This annex identifies the specific procedures for determination of the dentifrice abrasivity using the ADA [37] laboratory method. Other validated methods of similar or better sensitivity and accuracy may also be used.
A.2 Sampling A representative sample shall be taken from at least two batches. A.3 Procedure A.3.1 Standard reference abrasive 2) The primary reference abrasive is from a specific lot of calcium pyrophosphate . An alternate, silica 3) reference abrasive , or another well characterized material or composition that is well characterized and 2,3 its performance understood in the laboratory of choice may be used instead of calcium pyrophosphate. A.3.2 Apparatus A.3.2.1 Brushing machine 4) A cross-brushing machine is the apparatus of choice . The apparatus should have eight positions for holding specimens. A toothbrush shall be positioned to pass reciprocally at a small angle (approximately 5 °) over the mounted specimens, with a designated tension on the brush, while immersed in a dentifrice slurry. The distance traversed by the brush should not be longer than the brush head so that the specimen does not lose contact with the brush. The mechanism for holding the dentifrice slurry may vary with different machine designs but should allow for easy removal of the slurry sample. It is recommended to have some mechanism for the agitation of the slurry while the brushing is taking place. A convenient method to accomplish this is to attach rubber mixing vanes just below the brush head. As the brushing takes place, these vanes prevent the abrasive from settling to the bottom of the slurry container. A.3.2.2 Radioactivity detector The two recommended methods for the determination of the radioactivity of the used dentifrice slurries are a Geiger-Müller planchet counter and a liquid scintillation detector. The use of the Geiger counter requires 2) Reference calcium pyrophosphate was historically available from Odontex Inc. For more information contact ADA/ ANSI standards. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product.
3) One alternative reference silica is available from Evonik, Rodenbacher Chaussee 4, 63457 Hanau Wolfgang, Germany. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product.
4) One acceptable product is available from ODEME, odeme@odeme .com .br; https:// www .odeme .com .br the MEV 5 Series of cross-brushing machines. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product.
SIST EN ISO 11609:2026 ISO 11609:2026(en) that the samples be dried under defined controlled conditions. The liquid scintillation method has the advantage of reading directly from the slurry.
Counting should be done for a period, expected to reduce the alpha value for counting error to less than 2 %. Counting should be performed for a minimum of 1 000 counts and for at least 1 min. The number of brushing strokes may be increased if counting times become too long.
A.3.3 Preparation of tooth specimens A.3.3.1 Dentine specimens A.3.3.1.1 Selection Human root dentine of extracted permanent teeth is used as the substrate. Single-rooted teeth that were vital at extraction should be selected. An exception, because of the small size, are mandibular incisors: these should not be used. The specimen should be at least 14 mm long and 2 mm wide at the narrow end. All roots shall be caries-free and free of anatomical defects. After extraction, the roots should be stored in a neutralized solution that disinfects but does not alter the physical properties. A.3.3.1.2 Preparation Scrape the roots clean of all soft tissue and as much cementum as possible. Then remove the crown and the root tips using a separating disc under a flow of water.
A.3.3.1.3 Irradiation For each set of eight specimens to be irradiated, add one or two extra roots for use in correction factors. Pack the specimens in disinfection solution and submit to a nuclear reactor for irradiation. The neutron
flux should be sufficient to produce about 37 MBq (1 mCi) of P beta radiation after several hours. Elevated temperatures in the reactor (above 65 °C) should be avoided. A specific position shall be requested to shield the samples from fast neutrons and gamma radiation. Handling of the irradiated specimens should be done with care using good laboratory practice. The specimens should not be used during the first half-life because of excess radiation and should be used before the end of the third half-life because of lack of activity. The
half-life of P is 14,3 days so the usable life span of a set of teeth is 4 weeks. A.3.3.1.4 Mounting of specimens Mount the specimens individually in a mould in cold-cure methyl methacrylate resin such that either the buccal or lingual surface protrudes at least 2 mm above and parallel to the resin. Orient the mould in the brushing machine such that the direction of brushing is perpendicular to the long dimension of the root. Store the mounted specimens in a neutralized solution that disinfects but does not alter the physical properties.
NOTE The type and configuration of the mould depend on the holder of the brushing machine. A.3.3.2 Enamel specimens A.3.3.2.1 Selection Selection criteria for enamel specimens are the same as for dentine. The enamel specimens should be obtained from human maxillary incisors.
A.3.3.2.2 Preparation The entire labial surface of the specimen is used after removing the root. Clean the enamel in the same way as the root.
SIST EN ISO 11609:2026 ISO 11609:2026(en) A.3.3.2.3 Irradiation Irradiation of the enamel is identical to the method used with the roots. The roots and enamel specimens may be packed together for submission to the reactor.
A.3.3.2.4 Mounting Mount the enamel specimens in the same way as the roots. The labial surface shall protrude 2 mm and be parallel to the resin surface.
A.3.4 Toothbrushes The toothbrushes used should have Polyamid 66 (nylon) filaments about 10 mm in length. Filament ends should lie in a plane.
Store the brushes in water overnight prior to their first use and then keep them in water until they are discarded. Use a new set of brushes for each set of teeth. Do not remove the brushes from the machine between runs but raise the tufts off the specimen so as not to bend the bristles. At the beginning of each run, set the tension of the brush on the specimen to 150 g using a Chatillon spring gauge or equivalent. This tension should be rechecked at least twice daily. The method of adjusting the tension will vary depending upon the type of mechanism on the brushing machine.
A.3.5 Reference diluent 5) The diluent is a 0,5 % carboxymethyl cellulose (7MF CMC) solution in 10 % glycerine. To prepare 1 l of the diluent, heat 50 ml of glycerine to 60 °C and add 5 g of CMC while stirring. When the mixture is homogeneous, add another 50 ml of heated glycerine and continue stirring for 60 min. Transfer the solution to a 1 l flask and add 900 ml of distilled water. Allow to cool but continue stirring slowly overnight. To stabilize the viscosity, allow the solution to stand overnight before using. This solution is used to make up slurries of the reference abrasive or any powder being tested.
A.3.6 Reference abrasive slurry Using the reference material described in A.3.1, dilute 10 g of the abrasive with 50 ml of the diluent (see A.3.5). The same ratio is used for all powders. The reference abrasive can be used as a dentifrice. If this is the case, it shall be made up as a 40 % abrasive dentifrice with the rest of the constituents being conventional dentifrice components. The slurry is then made using 25 g of reference dentifrice and 40 ml of water. A.3.7 Dentifrice slurries To prepare the test slurries, add 40 ml of water to 25 g of each dentifrice. For the machine, prepare eight slurries of each dentifrice. This dilution produces a final slurry volume and concentration similar to those of the reference abrasive slurry. All slurries (reference and test) shall be used shortly after preparation and after vigorous mechanical stirring to prevent particles from settling. A.3.8 Preconditioning of tooth specimens A.3.8.1 Dentine To reduce the variation caused by dentine surface differences, precondition the specimens prior to each use. The preconditioning treatment consists of brushing with a slurry of the reference abrasive but not taking a sample. The first-time dentine specimens are used, the preconditioning should be for 6 000 strokes. Each successive daily run should begin with a shorter preconditioning brushing of 1 000 strokes. The tension of the toothbrush on the roots shall be 150 g.
5) An acceptable CMC is available from Hercules Incorporated, Aqualon Division, 1111 Hercules Road, Hopewell, VA 23860, USA, http:// www .ashland .com/ industries/ pharmaceutical/ oral -solid -dose/ aqualon -sodium -ca rboxymethylcellulose. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product.
SIST EN ISO 11609:2026 ISO 11609:2026(en) Discard the preconditioning slurries.
A.3.8.2 Enamel Preconditioning of the enamel is similar to that of the dentine, except that 10 000 strokes are used prior to the first use and 1 000 strokes are given at the beginning of each day. Discard the preconditioning slurries.
...



