FprEN 14511-4
(Main)Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 4: Requirements
Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 4: Requirements
1.1 The scope of FprEN 14511-1:2022 is applicable, with the exception of process chillers.
1.2 This document specifies minimum operating requirements which ensure that air conditioners, heat pumps and liquid chilling packages using either air, water or brine as heat transfer media, with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.
Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen für die Raumbeheizung und kühlung und Prozess-Kühler mit elektrisch angetriebenen Verdichtern - Teil 4: Anforderungen
1.1 Es gilt der Anwendungsbereich von FprEN 14511-1:2022 mit Ausnahme von Prozess-Kühlern.
1.2 Dieses Dokument legt Mindestbetriebsanforderungen fest, durch die sichergestellt ist, dass Luft-konditionierer, Wärmepumpen und Flüssigkeitskühlsätze, die Luft, Wasser oder Sole als Wärmeträger nutzen und mit elektrisch angetriebenen Verdichtern betrieben werden, für die vom Hersteller vorgesehene Anwendung geeignet sind, wenn sie für die Raumbeheizung und/oder -kühlung eingesetzt werden.
Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur pour le chauffage et le refroidissement des locaux et refroidisseurs industriels avec compresseur entraîné par moteur électrique - Partie 4 : Exigences
1.1 Le domaine d’application du FprEN 14511-1:2022 est applicable, à l’exception des refroidisseurs industriels.
1.2 Le présent document spécifie les exigences minimales permettant d’assurer que des climatiseurs, des pompes à chaleur et des groupes refroidisseurs de liquide utilisant l’air, l’eau ou l’eau glycolée comme fluide caloporteur, avec compresseur entraîné par moteur électrique, sont aptes à l’emploi prévu par le fabricant lorsqu’ils sont utilisés pour le chauffage et/ou le refroidissement des locaux.
Klimatske naprave, enote za hlajenje kapljevine, toplotne črpalke za ogrevanje in hlajenje prostora ter procesne hladilne naprave z električnimi kompresorji - 4. del: Zahteve
General Information
RELATIONS
Standards Content (sample)
SLOVENSKI STANDARD
oSIST prEN 14511-4:2021
01-april-2021
Klimatske naprave, enote za hlajenje kapljevine, toplotne črpalke za ogrevanje in
hlajenje prostora ter procesne hladilne naprave z električnimi kompresorji - 4. del:
ZahteveAir conditioners, liquid chilling packages and heat pumps for space heating and cooling
and process chillers, with electrically driven compressors - Part 4: Requirements
Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen für die Raumbeheizung und
-kühlung und Prozess-Kühler mit elektrisch angetriebenen Verdichtern - Teil 4:Anforderungen
Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur pour le chauffage et
le refroidissement des locaux et refroidisseurs industriels avec compresseur entraîné par
moteur électrique - Partie 4: ExigencesTa slovenski standard je istoveten z: prEN 14511-4
ICS:
23.120 Zračniki. Vetrniki. Klimatske Ventilators. Fans. Air-
naprave conditioners
27.080 Toplotne črpalke Heat pumps
91.140.30 Prezračevalni in klimatski Ventilation and air-
sistemi conditioning systems
oSIST prEN 14511-4:2021 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------oSIST prEN 14511-4:2021
---------------------- Page: 2 ----------------------
oSIST prEN 14511-4:2021
DRAFT
EUROPEAN STANDARD
prEN 14511-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2021
ICS Will supersede EN 14511-4:2018
English Version
Air conditioners, liquid chilling packages and heat pumps
for space heating and cooling and process chillers, with
electrically driven compressors - Part 4: Requirements
Climatiseurs, groupes refroidisseurs de liquide et Luftkonditionierer, Flüssigkeitskühlsätze und
pompes à chaleur pour le chauffage et le Wärmepumpen für die Raumbeheizung und -kühlung
refroidissement des locaux et refroidisseurs industriels und Prozess-Kühler mit elektrisch angetriebenen
avec compresseur entraîné par moteur électrique - Verdichtern - Teil 4: Anforderungen
Partie 4: ExigencesThis draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 113.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14511-4:2021 E
worldwide for CEN national Members.---------------------- Page: 3 ----------------------
oSIST prEN 14511-4:2021
prEN 14511-4:2021 (E)
Contents
European foreword ....................................................................................................................................................... 3
1 Scope .................................................................................................................................................................... 4
2 Normative references .................................................................................................................................... 4
3 Terms and definitions ................................................................................................................................... 4
4 Operating requirements ............................................................................................................................... 5
4.1 General ................................................................................................................................................................ 5
4.2 Temperature operating range .................................................................................................................... 5
4.3 Outside the operating range ....................................................................................................................... 8
4.4 Freeze-up test in cooling mode .................................................................................................................. 8
4.5 Shutting off the heat transfer medium flows ........................................................................................ 9
4.6 Complete power supply failure .................................................................................................................. 9
4.7 Condensate draining and enclosure sweat test.................................................................................... 9
4.8 Other requirements .................................................................................................................................... 10
5 Marking ............................................................................................................................................................ 11
6 Technical data sheet ................................................................................................................................... 11
6.1 General description ..................................................................................................................................... 11
6.2 Performance characteristics .................................................................................................................... 12
6.2.1 Rating characteristics ................................................................................................................................. 12
6.2.2 Additional characteristics ......................................................................................................................... 12
6.2.3 Sound characteristics ................................................................................................................................. 12
6.3 Electrical characteristics ........................................................................................................................... 12
6.4 Operating range ............................................................................................................................................ 12
7 Instructions .................................................................................................................................................... 13
7.1 General ............................................................................................................................................................. 13
7.2 Physical description .................................................................................................................................... 13
7.2.1 Refrigerant, air and/or liquid circuits .................................................................................................. 13
7.2.2 Additional heating devices, when integral to the unit .................................................................... 13
7.2.3 Control and safety ........................................................................................................................................ 13
7.3 Instructions for installation ..................................................................................................................... 13
7.4 Instruction for maintenance .................................................................................................................... 14
7.5 Instructions to test houses ........................................................................................................................ 14
Bibliography ................................................................................................................................................................. 15
---------------------- Page: 4 ----------------------oSIST prEN 14511-4:2021
prEN 14511-4:2021 (E)
European foreword
This document (prEN 14511-4:2021) has been prepared by Technical Committee CEN/TC 113 “Heat
pumps and air conditioning units”, the secretariat of which is held by UNE.This document is currently submitted to the Enquiry.
This document will supersede EN 14511-4:2018.
This document has been prepared in the frame of:
— the Commission Regulation (EU) No 206/2012 implementing Directive 2009/125/EC with regard to
ecodesign requirements for air conditioners;— the Commission Regulation (EU) n° 626/2011 supplementing Directive 2010/30/EU with regard to
energy labelling for air conditioners;— the Commission Regulation (EU) No 813/2013 implementing Directive 2009/125/EC with regard to
ecodesign requirements for air-to-water and water-to-water heat pump space heaters;
— the Commission Regulation (EU) n° 811/2013 supplementing Directive 2010/30/EU with regard to
energy labelling for air-to-water and water-to-water heat pump space heaters;— the Commission Regulation (EU) n° 2015/1095 implementing Directive 2009/125/EC of the
European Parliament and of the Council with regard to ecodesign requirements for process chillers;
— Commission Regulation (EU) 2016/2281 implementing Directive 2009/125/EC of the European
Parliament and of the Council with regard to ecodesign requirements for air heating products,
cooling products, high temperature process chillers and fan coil units.EN 14511, Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and
process chillers, with electrically driven compressors currently comprises the following parts:
— Part 1: Terms and definitions— Part 2: Test conditions
— Part 3: Test methods
— Part 4: Requirements
---------------------- Page: 5 ----------------------
oSIST prEN 14511-4:2021
prEN 14511-4:2021 (E)
1 Scope
1.1 The scope of prEN 14511-1:2021 is applicable, with the exception of process chillers.
1.2 This document specifies minimum operating requirements which ensure that air conditioners, heat
pumps and liquid chilling packages using either air, water or brine as heat transfer media, with electrical
driven compressors are fit for the use designated by the manufacturer when used for space heating
and/or cooling.2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 12102-1:2017, Air conditioners, liquid chilling packages, heat pumps, process chillers and dehumidifiers
with electrically driven compressors - Determination of the sound power level - Part 1: Air conditioners,
liquid chilling packages, heat pumps for space heating and cooling, dehumidifiers and process chillers
prEN 14511-1:2021, Air conditioners, liquid chilling packages and heat pumps for space heating and
cooling and process chillers, with electrically driven compressors — Part 1: Terms and definitions
prEN 14511-2:2021, Air conditioners, liquid chilling packages and heat pumps with electrically driven
compressors for space heating and cooling and process chillers, with electrically driven compressors —
Part 2: Test conditionsprEN 14511-3:2021, Air conditioners, liquid chilling packages and heat pumps for space heating and
cooling and process chillers, with electrically driven compressors — Part 3: Test methods
EN 60204-1:2018, Safety of machinery - Electrical equipment of machines - Part 1: General requirements
(IEC 60204-1:2016)prEN IEC 60335-2-40:2020, Household and similar electrical appliances — Safety — Part 2-40: Particular
requirements for electrical heat pumps, air-conditioners and dehumidifiers (IEC 60335-2-40:2018)
EN IEC 61000-3-11:2019, Electromagnetic compatibility (EMC) — Part 3-11: Limits — Limitation of
voltage changes, voltage fluctuations and flicker in public low-voltage supply systems — Equipment with
rated current ≤ 75 A and subject to conditional connection (IEC 61000-3-11:2017)3 Terms and definitions
For the purposes of this document, the terms and definitions given in prEN 14511-1:2021 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropedia.org/— ISO Online browsing platform: available at http://www.iso.org/obp
---------------------- Page: 6 ----------------------
oSIST prEN 14511-4:2021
prEN 14511-4:2021 (E)
4 Operating requirements
4.1 General
Except where otherwise stated, tests shall be conducted as described in prEN 14511-2:2021 and
prEN 14511-3:2021.4.2 Temperature operating range
4.2.1 Starting and operating tests
4.2.1.1 General
The unit shall be capable of starting and/or operating within the limit of use (temperatures and flows)
specified by the manufacturer.Rated voltage shall be set at the beginning of the test and maintained constant during the test.
The environmental conditions during the test shall be as specified in prEN 14511-2:2021, Tables 1 and
Air flow rates shall be the same as that used for the rating capacity test, as specified in
prEN 14511-2:2021.The temperatures shall be set at the beginning of the test and maintained constant during the test.
For a given air dry bulb temperature, the relative humidity shall be defined accordingly to Table 1 and
used for the calculation of the wet bulb temperature to be set.Table 1 — Determination of wet bulb temperature related to dry bulb temperature
Dry bulb temperature T Wet bulb temperature T
DB WB
°C °C
T < −11 Not defined
−10 ≤ T ≤ 12 T = T −1
DB WB DB
12 < T ≤ 20 T = 0,34 * T + 6,95
DB WB DB
T > 20 T = 0,6414 * T + 1,5931
DB WB DB
Deviation between individual values and set values shall be between:
— zero and minus twice the permissible deviation according to prEN 14511-3:2021, Table 4 for the
upper limit of use;— zero and plus twice the permissible deviation according to prEN 14511-3:2021, Table 4 for the lower
limit of use.Uncert
...
Questions, Comments and Discussion