General Information

Abstract

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and could be replaced independently of it.
This standard applies to curtain walling kit ranging from a vertical position to ± 15° from the vertical. Any sloping parts should be contained within the curtain walling kit.
This standard is applicable to the whole of the curtain walling kits, including the fixings.
Curtain walling according to this standard is intended to be used as part of the building envelope.
This European Standard does not include:
—   “Patent glazing” (glazed sloping roofs) kits;
—   Roof glazing constructions;
—   Façades made of precast concrete panels as part of the wall (see EN 14992).
NOTE 1   Precast concrete panels may be used in curtain walling kits as infill panels.
NOTE 2   Durability of structural sealed glazing infills is not covered by this standard.

Status
Published
Publication Date
10-May-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
11-May-2022
Completion Date
11-May-2022

Buy Documents

Corrigendum

EN 13830:2015+A1:2020/AC:2022

English language (3 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
16-Feb-2022

Buy Documents

Corrigendum

EN 13830:2015+A1:2020/AC:2022

English language (3 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Building products evaluation and certification.

ANAB United States Verified

QAI Laboratories

Building and construction product testing and certification.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 13830:2015+A1:2020/AC:2022 is a corrigendum published by the European Committee for Standardization (CEN). Its full title is "Curtain walling - Product standard". This standard covers: This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances. The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and could be replaced independently of it. This standard applies to curtain walling kit ranging from a vertical position to ± 15° from the vertical. Any sloping parts should be contained within the curtain walling kit. This standard is applicable to the whole of the curtain walling kits, including the fixings. Curtain walling according to this standard is intended to be used as part of the building envelope. This European Standard does not include: — “Patent glazing” (glazed sloping roofs) kits; — Roof glazing constructions; — Façades made of precast concrete panels as part of the wall (see EN 14992). NOTE 1 Precast concrete panels may be used in curtain walling kits as infill panels. NOTE 2 Durability of structural sealed glazing infills is not covered by this standard.

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances. The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and could be replaced independently of it. This standard applies to curtain walling kit ranging from a vertical position to ± 15° from the vertical. Any sloping parts should be contained within the curtain walling kit. This standard is applicable to the whole of the curtain walling kits, including the fixings. Curtain walling according to this standard is intended to be used as part of the building envelope. This European Standard does not include: — “Patent glazing” (glazed sloping roofs) kits; — Roof glazing constructions; — Façades made of precast concrete panels as part of the wall (see EN 14992). NOTE 1 Precast concrete panels may be used in curtain walling kits as infill panels. NOTE 2 Durability of structural sealed glazing infills is not covered by this standard.

EN 13830:2015+A1:2020/AC:2022 is classified under the following ICS (International Classification for Standards) categories: 91.060.10 - Walls. Partitions. Facades. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 13830:2015+A1:2020/AC:2022 has the following relationships with other standards: It is inter standard links to EN 13830:2015+A1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 13830:2015+A1:2020/AC:2022 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/108. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 13830:2015+A1:2020/AC:2022 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2022
Obešene fasade - Standard za proizvod - Popravek AC
Curtain walling - Product standard
Vorhangfassaden - Produktnorm
Façades rideaux - Norme de produit
Ta slovenski standard je istoveten z: EN 13830:2015+A1:2020/AC:2022
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 13830:2015+A1:2020/AC

NORME EUROPÉENNE
May 2022
EUROPÄISCHE NORM
ICS 91.060.10
English version
Curtain walling - Product standard
Façades rideaux - Norme de produit Vorhangfassaden - Produktnorm
This corrigendum becomes effective on 11 May 2022 for incorporation in the official English
version of the EN.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATIO N

EUROPÄISCHES KOMITEE FÜR NORMUN G

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members.

Ref. No.:EN 13830:2015+A1:2020/AC:2022 E

1 Modifications to Annex D, “Characteristics and range of direct application”
In Table D.1, row 4.12, last column, the table formatting has been corrected to make the full text after
“Profiles” visible. In row 4.13, last column, the table formatting has been corrected to make the full text after
“b) Rules for vertical flanking transmission” visible. These two rows now read as follows:

Glazing: Test results on airborne
sound insulation of a complete
façade element can be transferred
to a façade element with a different
glazing configuration if the new
glazing has a sound insulation
equal or higher than the glazing in
the tested element. Sound
insulation of the glazing shall be
derived from acoustic tests on a
test specimen (in dimensions 1,23
m × 1,48 m) acc. to EN ISO 10140-2
together with the rules from
EN 12758.
Panels: Test results on airborne
sound insulation of a complete
façade element can be transferred
to a façade element with a different
panel configuration if the new
panel has a sound insulation equal
or higher than the panel in the
tested element. Sound insulation of
EN ISO 10140-2
Direct airborne Non-
4.12 EN ISO 717-1   the panel shall be derived from
sound insulation destructive
acoustic tests on
...