This standard describes a set of procedures for using existing standardized CEN or ISO test and calculation methods to determine the declared thermal performance of reflective insulation products. This standard supports and does not replace existing CEN or ISO test methods.This standard applies to any thermal insulation product that derives a proportion of its claimed thermal properties from the presence of one or more reflective or low emissivity surfaces together with any associated airspace(s). It does not replace the existing procedures for the determination of the thermal performance of products already covered by an existing harmonized product standard where the declared value of these products does not specifically include any claims attributable to the emissivity of the facing.
Wärmedämmstoffe für Gebäude - Reflektierende Wärmedämm-Produkte - Bestimmung der Nennwerte der wärmetechnischen Eigenschaften
Isolation thermique des bâtiments - Produits d’isolation réfléchissants - Détermination de la performance thermique déclarée
Toplotnoizolacijski proizvodi za stavbe - Odsevni izolacijski proizvodi - Ugotavljanje nazivnih toplotnih lastnosti
General Information
- Status
- Not Published
- Technical Committee
- CEN/TC 89 - Thermal performance of buildings and building components
- Drafting Committee
- CEN/TC 89/WG 12 - Reflective insulation products
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 22-Oct-2014
- Due Date
- 28-Jul-2015
- Completion Date
- 22-Oct-2014
- Directive
- 89/106/EEC - Construction products
Relations
- Effective Date
- 16-Nov-2014
- Effective Date
- 18-Apr-2012
Overview
EN 16012:2012/FprA1 is a CEN draft amendment that defines how to determine the declared thermal performance of reflective insulation products used in buildings. The standard provides procedures for combining existing CEN/ISO test methods (hot plate, hot box, emissivity measurement and calculation techniques) to produce a declared thermal resistance (R‑value) for products that derive part of their performance from reflective or low‑emissivity surfaces plus associated airspace(s). It supports - but does not replace - existing harmonized product standards.
Key topics and technical requirements
- Purpose: determine declared thermal resistance (R) for reflective insulation products using standardized tests and calculation rules.
- Product scope: any insulation whose claimed performance depends on one or more reflective/low‑emissivity faces and associated airspace(s). Excludes products already covered by harmonized standards where emissivity is not claimed.
- Statistical declaration: declared values must represent at least 90% of production at 90% confidence using the 90/90 fractile rules from EN ISO 10456.
- Minimum testing: at least 3 test results (preferably from 3 different production batches) are required for calculation; manufacturers may use more.
- Specimen size and numbers: specimen minimum size 250 mm × 250 mm; when faces differ, take at least three specimens per face.
- Emissivity measurement (Annex D): express emissivity to two decimal places; single measurements outside apparatus range are clamped to 0.02 (min) or 0.94 (max); a mean emissivity below 0.05 is declared as 0.05.
- Rounding rules: core thermal resistance rounded down to nearest 0.01 m²·K/W; airspace resistances rounded down to 0.05 m²·K/W.
- Calculation options: combine core R, measured emissivity and calculated air cavity resistances (EN ISO 6946) or use measured hot box/hot plate results depending on product type (Types 1–4 described in EN 16012).
Applications and who uses it
- Manufacturers of reflective insulation: to generate robust, defendable declared R‑values for labels, datasheets and CE marking.
- Test laboratories: to perform hot plate, hot box and emissivity testing to the specified sampling, reporting and rounding rules.
- Product certifiers and regulators: to assess conformity of declared thermal performance and ensure statistical basis of claims.
- Architects, specifiers and energy consultants: to compare reflective insulation products using consistent declared R‑values for building design and energy calculations.
Related standards
- EN ISO 10456 - statistical calculation rules and declared values (90/90 fractile)
- EN ISO 6946 - thermal resistance calculation for building components and air cavities
- EN 823 - thickness measurement for thermal insulation products
EN 16012:2012/FprA1 ensures consistent, statistically sound determination of thermal performance for reflective insulation products, aligning emissivity testing and R‑value declaration with established CEN/ISO methods.
Frequently Asked Questions
EN 16012:2012/FprA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance". This standard covers: This standard describes a set of procedures for using existing standardized CEN or ISO test and calculation methods to determine the declared thermal performance of reflective insulation products. This standard supports and does not replace existing CEN or ISO test methods.This standard applies to any thermal insulation product that derives a proportion of its claimed thermal properties from the presence of one or more reflective or low emissivity surfaces together with any associated airspace(s). It does not replace the existing procedures for the determination of the thermal performance of products already covered by an existing harmonized product standard where the declared value of these products does not specifically include any claims attributable to the emissivity of the facing.
This standard describes a set of procedures for using existing standardized CEN or ISO test and calculation methods to determine the declared thermal performance of reflective insulation products. This standard supports and does not replace existing CEN or ISO test methods.This standard applies to any thermal insulation product that derives a proportion of its claimed thermal properties from the presence of one or more reflective or low emissivity surfaces together with any associated airspace(s). It does not replace the existing procedures for the determination of the thermal performance of products already covered by an existing harmonized product standard where the declared value of these products does not specifically include any claims attributable to the emissivity of the facing.
EN 16012:2012/FprA1 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 16012:2012/FprA1 has the following relationships with other standards: It is inter standard links to EN 16012:2012+A1:2015, EN 16012:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 16012:2012/FprA1 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 16012:2012/FprA1 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2014
Toplotnoizolacijski proizvodi za stavbe - Odsevni izolacijski proizvodi -
Ugotavljanje nazivnih toplotnih lastnosti
Thermal insulation for buildings - Reflective insulation products - Determination of the
declared thermal performance
Wärmedämmstoffe für Gebäude - Reflektierende Wärmedämm-Produkte - Bestimmung
der Nennwerte der wärmetechnischen Eigenschaften
Isolation thermique des bâtiments - Produits d’isolation réfléchissants - Détermination de
la performance thermique déclarée
Ta slovenski standard je istoveten z: EN 16012:2012/FprA1
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
FINAL DRAFT
EN 16012:2012
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
May 2014
ICS 91.100.60
English Version
Thermal insulation for buildings - Reflective insulation products -
Determination of the declared thermal performance
Isolation thermique des bâtiments - Produits d'isolation Wärmedämmstoffe für Gebäude - Reflektierende
réfléchissants - Détermination de la performance thermique Wärmedämm-Produkte - Bestimmung der Nennwerte der
déclarée wärmetechnischen Eigenschaften
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 89.
This draft amendment A1, if approved, will modify the European Standard EN 16012:2012. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16012:2012/FprA1:2014 E
worldwide for CEN national Members.
Contents Page
Foreword .3
1 Modification to Clause 2 .4
2 Modification to 3.2 .4
3 Modifications to Clause 5 .4
3.1 Modification to 5.2, Thickness measurement .4
3.2 Modification to 5.3, Conditioning and specimen preparation .4
3.3 Modification to 5.4, Determination of thermal resistance – outline .4
4 Modifications to Clause 7 .5
4.1 Modification to 7.1, Results derived from hot plate and emissivity measurements
(Products Type 1 & 2) .5
4.2 Modification to 7.2, Results derived from hot box and emissivity measurements (Product
Types 1, 2 & 3) .5
4.3 Modification to 7.3 Results derived from emissivity measurements only (product Type 4) .6
5 Modifications to Annex D, Measurement of emissivity using a Thermal Infra-Red
apparatus .6
5.1 Modification to D.5.2, Dimensions and numbers of specimens .6
5.2 Modification to D.7, Expression of results .6
Foreword
This document (EN 16012:2012/FprA1:2014) has been prepared by Technical Committee CEN/TC 89
“Thermal performance of buildings and building components”, the secretariat of which is held by SIS.
This document is currently submitted to the Unique Acceptance Procedure.
1 Modification to Clause 2
After EN 823, delete the reference to the date "1994".
2 Modification to 3.2
Add the following symbols:
1) In the Table of Symbols:
Symbol Quantity Unit
"R thermal resistance m²·K/W"
2) In the Table of Subscripts:
Subscripts
"90/90 90 % fractile with a confidence level of 90 %"
3 Modifications to Clause 5
3.1 Modification to 5.2, Thickness measurement
In the second line of 5.2 delete the reference ":1994
...