Glass in building - Insulating glass units - Part 5: Evaluation of conformity

This European Standard specifies requirements, the evaluation of conformity and the factory production control of insulating glass units for use in buildings.
NOTE 1   For glass products with electrical wiring or connections for e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, roofs and partitions where there exists protection against direct ultraviolet radiation at the edges.
NOTE 2   In cases where there is no protection against direct ultra-violet radiation at the edges, such as structural sealant glazing systems, additional European technical specifications should be followed (e.g. !EN 15434", !EN 13022-1").
NOTE 3   Units for which the intended use is only ‘artistic’ and therefore no essential requirement is required, are not subject to CE marking and are not part of this European Standard.

Glas im Bauwesen - Mehrscheiben-Isolierglas - Teil 5: Konformitätsbewertung

Diese Europäische Norm legt Anforderungen an sowie die Konformitätsbewertung und die werkseigene Produktionskontrolle für Mehrscheiben Isolierglas zur Verwendung in Gebäuden fest.
ANMERKUNG 1   Für Glasprodukte mit elektrischer Verdrahtung oder elektrischen Anschlüssen, z. B. zu Alarm  oder Heizzwecken, gelten möglicherweise weitere Richtlinien, z. B. die Niederspannungsrichtlinie.
Der vorgesehene Hauptverwendungszweck der Mehrscheiben Isoliergläser ist der Einbau in Fenster, Türen, Vorhangfassaden, Dächer und Trennwände, wobei die Ränder des Glases gegen direkte UV Strahlung geschützt sind.
ANMERKUNG 2   Falls die Ränder nicht gegen direkte UV Strahlung geschützt sind, wie z. B. bei geklebten Verglasungen ("Structural Sealant Glazing"-Systeme), sollten zusätzliche Europäische Technische Spezifikationen befolgt werden (z. B. EN 15434, EN 13022-1).
ANMERKUNG 3   Einheiten, die nur für "künstlerische" Zwecke vorgesehen sind und für die daher keine wesentlichen Anforderungen gelten, sind nicht Gegenstand der CE Kennzeichnung und werden von dieser Europäischen Norm nicht erfasst.

Verre dans la construction - Vitrage isolant - Partie 5: Evaluation de la conformité

La présente Norme européenne spécifie des exigences relatives à l'évaluation de la conformité et au contrôle de la production en usine des vitrages isolants utilisés dans la construction.
NOTE 1   Pour les produits verriers équipés d'un câblage ou de branchements électriques pour les besoins d'alarme ou de chauffage, par exemple, d’autres directives, comme par exemple la Directive «Basse(s) Tension(s)», peuvent s’appliquer.
Les usages prévus des vitrages isolants sont principalement les installations dans des fenêtres, portes, murs rideaux, toitures et cloisons offrant une protection des bords contre les rayonnements ultraviolets directs.
NOTE 2   En l’absence de protection contre les rayonnements ultraviolets directs sur les bords, comme par exemple pour les vitrages extérieurs collés, il convient de se conformer à d'autres spécifications techniques européennes (par exemple !EN 15434", !EN 13022-1").
NOTE 3   Les vitrages de nature purement «artistique», et pour lesquels aucune exigence essentielle n’est requise, ne sont pas soumis au marquage CE et ne sont pas couverts par la présente Norme européenne.

Steklo v gradbeništvu - Izolacijsko steklo - 5. del: Ovrednotenje skladnosti

General Information

Status
Withdrawn
Publication Date
11-Nov-2008
Withdrawal Date
04-May-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
05-May-2010
Completion Date
05-May-2010

Relations

Buy Standard

Standard
EN 1279-5:2005+A1:2009
English language
31 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Steklo v gradbeništvu - Izolacijsko steklo - 5. del: Ovrednotenje skladnostiGlas im Bauwesen - Mehrscheiben-Isolierglas - Teil 5: KonformitätsbewertungVerre dans la construction - Vitrage isolant - Partie 5: Evaluation de la conformitéGlass in building - Insulating glass units - Part 5: Evaluation of conformity81.040.20Steklo v gradbeništvuGlass in buildingICS:Ta slovenski standard je istoveten z:EN 1279-5:2005+A1:2008SIST EN 1279-5:2005+A1:2009en,fr,de01-maj-2009SIST EN 1279-5:2005+A1:2009SLOVENSKI
STANDARDSIST EN 1279-5:20051DGRPHãþD



SIST EN 1279-5:2005+A1:2009



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1279-5:2005+A1
November 2008 ICS 81.040.20 Supersedes EN 1279-5:2005 English Version
Glass in building - Insulating glass units - Part 5: Evaluation of conformity
Verre dans la construction - Vitrage isolant - Partie 5: Evaluation de la conformité
Glas im Bauwesen - Mehrscheiben-Isolierglas - Teil 5: Konformitätsbewertung This European Standard was approved by CEN on 24 March 2005 and includes Amendment 1 approved by CEN on 2 October 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1279-5:2005+A1:2008: ESIST EN 1279-5:2005+A1:2009



EN 1279-5:2005+A1:2008 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Terms and definitions.5 4 Requirements.6 4.1 Product description.6 4.2 Conformity with the definition of insulating glass units.6 4.3 Determination of the characteristic’s performances.6 4.4 Durability.10 4.5 Dangerous substances.10 5 Evaluation of conformity.10 5.1 General.10 5.2 Initial type testing of the product (see 5.1, 2)).11 5.3 Factory production control and inspection of samples in accordance with a prescribed test plan (5.1, 1) and 2)).13 5.4 Initial inspection of factory and of factory production control (5.1, 1), 2)).14 5.5 Continuous surveillance an
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.