Communication system for meters - Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information

This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.

Kommunikationssysteme für Zähler - Begleitender Technischer Bericht zu EN 13757-2, -3 und -7, Beispiele und ergänzende Informationen

Systèmes de communication pour compteurs - Rapport technique accompagnant les EN 13757-2,-3 et -7 - Exemples et informations supplémentaires

Komunikacijski sistemi za merilnike - Spremno tehnično poročilo k EN 13757-2,-3 in -7 - Primeri in dodatni podatki

To tehnično poročilo vsebuje dodatne podatke k zahtevam, opredeljenim v standardih EN 13757-2, EN 13757-3 in EN 13757-7, predvsem primere uvedbe, primere datagramov, ki jih zadrži varnostni mehanizem, opredeljen v 7. delu, ter dodatne zahteve, ki niso normativne in presegajo področje komunikacije merilnikov.

General Information

Status
Withdrawn
Publication Date
03-Apr-2018
Withdrawal Date
19-Dec-2023
Current Stage

Relations

Buy Standard

Technical report
TP CEN/TR 17167:2018 - BARVE
English language
87 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2018
.RPXQLNDFLMVNLVLVWHPL]DPHULOQLNH6SUHPQRWHKQLþQRSRURþLORN(1
LQ3ULPHULLQGRGDWQLSRGDWNL
Communication system for meters - Accompanying TR to EN 13757-2,-3 and -7,
Examples and supplementary information
Kommunikationssysteme für Zähler - Begleitender Technischer Bericht zu EN 13757-2, -
3 und -7, Beispiele und ergänzende Informationen
Systèmes de communication pour compteurs - Rapport technique accompagnant les EN
13757-2,-3 et -7 - Exemples et informations supplémentaires
Ta slovenski standard je istoveten z: CEN/TR 17167:2018
ICS:
33.200 Daljinsko krmiljenje, daljinske Telecontrol. Telemetering
meritve (telemetrija)
35.240.99 8SRUDEQLãNHUHãLWYH,7QD IT applications in other fields
GUXJLKSRGURþMLK
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CEN/TR 17167
TECHNICAL REPORT
RAPPORT TECHNIQUE
April 2018
TECHNISCHER BERICHT
ICS 33.200; 35.240.99; 91.140.50
English Version
Communication system for meters - Accompanying TR to
EN 13757-2,-3 and -7, Examples and supplementary
information
Systèmes de communication pour compteurs - Rapport Kommunikationssysteme für Zähler - Begleitender
technique accompagnant les EN 13757-2,-3 et -7 - Technischer Bericht zu EN 13757-2, -3 und -7,
Exemples et informations supplémentaires Beispiele und ergänzende Informationen

This Technical Report was approved by CEN on 13 November 2017. It has been drawn up by the Technical Committee CEN/TC
294.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 17167:2018 E
worldwide for CEN national Members.

Contents Page
European foreword . 5
Introduction . 6
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 8
4 Symbols and abbreviations . 9
4.1 Abbreviations . 9
4.2 Symbols . 10
5 Overview . 10
Annex A (informative) Examples . 12
A.1 General . 12
A.2 Example for a RSP-UD . 12
A.3 Example baud rate switch . 12
A.4 Example application select with subcode . 13
A.5 Writing data to a slave . 13
A.6 Configuring M-Bus data output . 14
A.6.1 General . 14
A.6.2 Selection of data records with special data field . 15
A.6.3 Selection of data records with object action code . 16
A.6.4 Deselection of data records . 16
A.7 FCB and selection . 17
A.7.1 FCB-implementation slave . 17
A.7.2 FCB-implementation master . 17
A.8 Use of the fabrication number . 18
Annex B (informative) Secondary search - Instructions for implementation of wildcard
search . 20
Annex C (informative) Consumer feedback for smart metering applications . 22
C.1 General . 22
C.2 Resolution of required values and accuracy of time information . 22
C.2.1 General . 22
C.2.2 Resolution in case of transmission of extra data points for power/flow rate . 23
C.2.3 Resolution in case of non-transmission of extra data points for power/flow rate . 23
C.2.3.1 General . 23
C.2.3.2 Assumptions on time information for wireless connections . 24
C.2.3.2.1 General . 24
C.2.3.2.2 Correlated transmission . 24
C.2.3.2.3 Uncorrelated transmission . 24
C.2.4 Transmission on request . 24
Annex D (informative) Installation and registration . 25
D.1 General . 25
D.2 Registration with meter support . 26
D.2.1 Introduction. 26
D.2.2 RF-Link feedback . 26
D.2.3 Registration feedback . 26
D.3 Registration without meter support . 26
Annex E (informative) M-Bus data container . 28
E.1 Explanation . 28
E.2 Definition . 28
E.3 Example . 29
Annex F (informative) Datagram examples for the M-Bus and the wM-Bus . 30
F.1 Colour coding of the datagram examples . 30
F.2 Security mode 5 example . 30
F.3 Security mode 7 example . 34
F.4 Security mode 8 example . 42
F.5 Security Mode 9 example . 46
F.5.1 General . 46
F.5.2 Example input vectors . 46
F.5.3 Example Mode 9 on SND-NR datagram . 47
F.5.4 Example applying Mode 9 on RSP-UD datagram . 49
F.6 Security mode 10 example . 52
F.7 Special messages . 57
F.7.1 Installation procedure with a special installation message . 57
F.7.2 Send a command with an acknowledge . 62
F.7.3 Request of the selected data . 66
F.7.4 Reset of the link by a SND-NKE . 69
F.7.5 Key transfer according SITP . 71
F.7.6 Transfer secured application data according SITP . 76
Annex G (informative) Descriptors . 81
G.1 General . 81
G.2 Storage descriptors . 81
G.2.1 Storage interval descriptor . 81
G.2.2 Storage range descriptor . 82
G.3 Subunit descriptor . 82
G.4 Tariff descriptor . 83
G.5 Examples . 84
G.5.1 Example: Storage descriptor . 84
G.5.2 Example: Subunit descriptor . 86
G.5.3 Example: Tariff descriptor . 86
Bibliography .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.