prEN 15269-4
(Main)'Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 4: Fire resistance of hinged and pivoted glass doorsets'
'Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 4: Fire resistance of hinged and pivoted glass doorsets'
This European Standard covers hinged and pivoted doors, doorsets and door assemblies with glass based
leaves. Throughout this document the term “doorset” will be used to cover doors, doorsets and door
assemblies. It prescribes the methodology for extending the application of test results obtained from fire
resistance test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some
of the following examples:
integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classification;
ambient temperature smoke control (Sa) and medium temperature smoke control (S200)
classifications;
ability to close and durability of self-closing (C0 – C5);
glazed elements;
side, transom or over panels;
items of building hardware;
decorative and protective finishes;
intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals;
alternative supporting construction(s).
This standard does not cover horizontal doorsets and windows.
Erweiterter Anwendungsbereich von Prüfergebnissen zur Feuerwiderstandsfähigkeit und/oder Rauchdichtigkeit von Türen, Toren und Fenstern einschließlich ihrer Baubeschläge - Teil 4: Feuerwiderstand von Drehflügeltüren aus Glas
Dieses Dokument gilt für Dreh- und Schwenktüren, Türelemente und Türbaugruppen mit Glasflügeln. In diesem Dokument wird der Begriff „Tür“ verwendet, um sowohl Türen, als auch Türelemente und die aus verschiedenen Elementen bestehende Türeinheit abzudecken. Es schreibt die Methodologie zur Erweiterung der Anwendung von Ergebnissen der Prüfung(en) der Feuerwiderstandsfähigkeit nach EN 1634-1 und/oder EN 1634-3 und/oder EN 1191 vor.
In Abhängigkeit von der Durchführung der entsprechenden Prüfung(en) kann der erweiterte Anwendungsbereich einige oder alle der folgenden Bereiche abdecken:
— Klassifizierungen von nicht wärmegedämmten Elementen (E) sowie solchen mit Anforderungen an die Strahlung (EW) oder wärmegedämmten Elementen (EI1 oder EI2);
— Klassifizierungen der Rauchdichtheit bei Umgebungstemperatur (Sa) und der Rauchdichtheit bei erhöhter Temperatur (S200);
— Fähigkeit zum Schließen und Dauerhaftigkeit der Selbstschließung (C0 – C5);
— verglaste Bauteile;
— Seiten-, Querträger- oder Oberteile;
— Baubeschläge;
— dekorative Beschichtungen und/oder Schutzbeschichtungen;
— dämmschichtbildende Dichtungen und nicht dämmschichtbildende Dichtungen zur Behinderung von Rauchdurchtritt (Rauchschutzdichtungen), Durchzug oder Schallübertragung (Schallschutzdichtungen);
— alternative Tragkonstruktion(en).
Dieses Dokument behandelt keine horizontalen Türen und Fenster.
Application étendue des résultats d’essais en matière de résistance au feu et/ou d’étanchéité à la fumée des blocs-portes, blocs-fermetures et ouvrants de fenêtre, y compris leurs éléments de quincaillerie intégrés - Partie 4 : Résistance au feu des blocs-portes battants et pivotants en verre
Le présent document couvre les portes battantes et pivotantes, les blocs-portes et les ensembles de
portes avec des vantaux à base de verre. Tout au long du présent document, le terme « bloc-porte »
servira à désigner les portes, les blocs-portes et les ensembles de portes. En effet, cet emploi induit
l’application de la méthodologie permettant d’étendre les résultats d’essais obtenus lors du ou des
essais de résistance au feu effectués conformément à l’EN 1634-1 et/ou EN 1634-3 et/ou EN 1191.
Sous réserve de la réalisation de l’essai ou des essais appropriés, l’application étendue peut couvrir tout
ou partie des exemples suivants :
— les classements d’étanchéité au feu (E), d’étanchéité au feu/rayonnements (EW) ou d’étanchéité au
feu/isolation thermique (EI1 ou EI2) ;
— les classements d’étanchéité à la fumée à température ambiante (Sa) et d’étanchéité à la fumée à
température moyenne (S200) ;
— la capacité de fermeture et la durabilité de la fermeture automatique (C0 – C5) ;
— les éléments vitrés ;
— les panneaux latéraux, d’imposte ou supérieurs affleurants ;
— les éléments de quincaillerie de bâtiment ;
— les finitions décoratives et de protection ;
— les joints intumescents et les joints non-intumescents (étanchéité à la fumée, l’air, acoustique) ;
— une ou plusieurs autres constructions supports.
Le présent document ne couvre pas les blocs-portes et fenêtres au format paysage.
Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti za vrata, zapore in okna, ki se odpirajo, vključno z njihovim okovjem - 4. del: Požarna odpornost steklenih vrat na tečajih z vrtljivim krilom
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2022
Razširjena uporaba rezultatov preskusov požarne odpornosti in/ali dimotesnosti
za vrata, zapore in okna, ki se odpirajo, vključno z njihovim okovjem - 4. del:
Požarna odpornost steklenih vrat na tečajih z vrtljivim krilom
'Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware -
Part 4: Fire resistance of hinged and pivoted glass doorsets'
Erweiterter Anwendungsbereich von Prüfergebnissen zur Feuerwiderstandsfähigkeit
und/oder Rauchdichtigkeit von Türen, Toren und Fenstern einschließlich ihrer
Baubeschläge - Teil 4: Feuerwiderstand von Drehflügeltüren aus Glas
Application étendue des résultats d ’essais en matière de résistance au feu et/ou
d’étanchéité à la fumée des blocs-portes, blocs-fermetures et ouvrants de fenêtre, y
compris leurs éléments de quincaillerie intégrés - Partie 4 : Résistance au feu des blocs-
portes battants et pivotants en verre
Ta slovenski standard je istoveten z: prEN 15269-4
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.50 Vrata in okna Doors and windows
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2022
ICS 13.220.50; 91.060.50
English Version
'Extended application of test results for fire resistance
and/or smoke control for door, shutter and openable
window assemblies, including their elements of building
hardware - Part 4: Fire resistance of hinged and pivoted
glass doorsets'
Application étendue des résultats d'essais en matière Erweiterter Anwendungsbereich von Prüfergebnissen
de résistance au feu et/ou d'étanchéité à la fumée des zur Feuerwiderstandsfähigkeit und/oder
blocs-portes, blocs-fermetures et ouvrants de fenêtre, y Rauchdichtigkeit von Türen, Toren und Fenstern
compris leurs éléments de quincaillerie intégrés - einschließlich ihrer Baubeschläge - Teil 4:
Partie 4 : Résistance au feu des blocs-portes battants et Feuerwiderstand von Drehflügeltüren aus Glas
pivotants en verre
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 127.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15269-4:2022 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Determination of the field of extended application . 7
5 Extended application report . 9
6 Classification report. 9
Annex A (normative) Construction parameter variations . 10
Annex B (normative) Configurations for doorsets incorporating side and/or over panels . 97
Annex C (normative) Construction parameter variations - weight . 120
Annex D (normative) Construction parameter variations - timber replacement . 121
Annex E (normative) Test scenarios for Butt joint glazing as supporting construction . 122
Bibliography . 125
European foreword
This document (prEN 15269-4:2022) has been prepared by Technical Committee CEN/TC 127 “Fire
safety in buildings”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
This document is one of a series entitled EN 15269 or EN 17020. A list of all parts in the EN 15269 and
the EN 17020 series can be found on the CEN website.
Introduction
This document is one of the EN 15269 and EN 17020 series of standards to be used for the purpose of
producing an extended application report based on the evaluation of one or more fire resistance and/or
smoke control and/or durability of self-closing tests. These standards may also be used to identify the
best selection of test specimens required to cover a wide range of product variations.
A review of the doorset construction parameters can indicate that one or more characteristics may be
improved by a particular parameter variation. All evaluations need to be made on the basis of retaining
the fire resistance and/or smoke control and/or durability of self-closing classification(s) obtained from
testing to the relevant test standard. However, this will never lead to an increased classification for any
specific performance parameter beyond that achieved during any one test unless specifically identified
in the relevant Construction Parameter Variation Table within this standard.
For general requirements for applying this standard see EN 15269-1.
1 Scope
This document covers hinged and pivoted doors, doorsets and door assemblies with glass based leaves.
Throughout this document the term “doorset” will be used to cover doors, doorsets and door assemblies.
It prescribes the methodology for extending the application of test results obtained from fire resistance
test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some
of the following examples:
— integrity (E), integrity & radiation (EW) or integrity & insulation (EI or EI ) classification;
1 2
— ambient temperature smoke control (Sa) and medium temperature smoke control (S )
classifications;
— ability to close and durability of self-closing (C0 – C5);
— glazed elements;
— side, transom or over panels;
— items of building hardware;
— decorative and protective finishes;
— intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals;
— alternative supporting construction(s).
This document does not cover horizontal doorsets and windows.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 179, Building hardware - Emergency exit devices operated by a lever handle or push pad, for use
on escape routes - Requirements and test methods
EN 844 (all parts), Round and sawn timber — Terminology
EN 1154, Building hardware - Controlled door closing devices - Requirements and test methods
EN 1191, Windows and doors - Resistance to repeated opening and closing - Test method
EN 1363-1, Fire resistance tests - Part 1: General requirements
EN 1364-1:2015, Fire resistance tests for non-loadbearing elements - Part 1: Walls
EN 1634-1, Fire resistance and smoke control tests for door, shutter and openable window assemblies
and elements of building hardware — Part 1: Fire resistance test for doors, shutters and openable
windows
EN 1634-2, Fire resistance and smoke control tests for door, shutter and openable window assemblies
and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building
hardware
EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows
and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
EN 1935, Building hardware - Single-axis hinges - Requirements and test methods
EN 12150-1, Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition
and description
EN 12519, Windows and pedestrian doors - Terminology
EN 13501-2, Fire classification of construction products and building elements - Part 2: Classification
using data from fire resistance tests, excluding ventilation services
EN 15254-4:2018, Extended application of results from fire resistance tests - Non-loadbearing walls -
Part 4: Glazed constructions
EN 15269-1, Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware - Part 1: General
requirements
EN ISO 13943, Fire safety - Vocabulary (ISO 13943)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1363-1, EN 12519,
EN ISO 13943, EN 1634-1, EN 1634-2, EN 1634-3, EN 1191 and EN 15269-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at https://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
most onerous configuration
configuration with the lowest relevant performance in terms of mode of failure and/or highest distortion,
also be evaluated taking the intended construction parameter variation(s) into account
Note 1 to entry: For example if the construction parameter variation involves a change to glazing or side panel and
over panel configurations then the previous result where these have been tested would need to be used to make the
evaluation of most onerous.
3.2
effective rebate depth
dimension of the door leaf thickness of overlapping adjacent edges of door leaf relative to the door frame,
transom or side panel or flush over panel
3.3
hybrid frame
frame constructed of a steel core material, cladded with insulating inorganic materials (e.g. gypsum)
3.4
doorset without frame
door leaf directly installed in the supporting construction (low or high density rigid supporting
construction or a previously tested non-standard supporting construction)
3.5
representative specimen
similar design
fundamentally the same
door leaf design which has ‘fundamentally the same’ or ‘similar’ construction as another door leaf design
for the purpose of evaluating parameter variations providing the relevant aspects of tested performance
are considered
Note 1 to entry: see EN 15269-1 for further guidance on evaluation of similar/fundamentally the same
3.6
single action doorset
doorset which opens only in one direction, from closed position up to a maximum of 180°
3.7
double action doorset
swing door
doorset which opens in both directions, from closed position up to a maximum of ±180°
3.8
full scale test
test of a doorset in accordance with EN 1634-1
3.9
small scale test
test on elements of building hardware in accordance with EN 1634-2 and where the decision process,
given in EN 1634-2, permits its use
3.10
flush over panel
panel above the door without a transom
4 Determination of the field of extended application
4.1 General
4.1.1 Before there can be any consideration for extended application, a representative doorset shall have
been tested in accordance with EN 1634-1 and/or EN 1634 3 and/or EN 1191 to achieve a test result
which could generate a classification in accordance with EN 13501-2 at least equal to the classification
subsequently required from extended application considerations.
4.1.2 A review of the d
...