General Information

Abstract

This standard specifies instructions for mounting and fixing for reaction to fire testing of factory made thermal insulation products.

Status
Published
Publication Date
03-Nov-2009
Current Stage
9092 - Decision on results of review/2YR ENQ - revise - Review Enquiry
Start Date
05-Jun-2026
Completion Date
02-Sep-2026

Buy Documents

Overview

EN 15715:2009 - Thermal insulation products: Instructions for mounting and fixing for reaction to fire testing (factory made products) is a CEN European Standard that specifies how factory-made thermal insulation products must be mounted and fixed when subjected to reaction-to-fire tests. The standard ensures reproducible laboratory conditions so that fire performance test results (ignitability, spread, heat release) are comparable and valid for product assessment and classification.

Key topics and requirements

  • Scope & principle: Defines the purpose and testing principle for mounting specimens to assess reaction to fire.
  • Product and installation parameters: Lists required parameters to be recorded (material type, thickness, geometry) and installation conditions affecting test outcomes.
  • Mounting and fixing rules: Detailed instructions on how to mount and mechanically fix specimens for:
    • Ignitability tests (EN ISO 11925-2) - single-flame exposure methods.
    • Single Burning Item (SBI) tests (EN 13823) - room-corner test assessing heat release and flaming behavior.
  • Standardised assemblies: Procedures for testing products installed in assemblies that simulate end-use applications (walls, façades, roofs, pipes).
  • Field of application / validity: Guidance on the applicability of test results across product families and similar installations.
  • Product-specific annexes: Annex A contains product-specific mounting parameters and tables for a wide range of materials (mineral wool, EPS, XPS, PUR/PIR, phenolic foam, cellular glass, wood-based insulants, elastomeric foams, calcium silicate, polyethylene foam, etc.).

Applications and who uses it

  • Manufacturers use EN 15715 to prepare specimens and test reports that reliably reflect in-service fire behaviour and to support CE marking or product declarations.
  • Test laboratories follow the standard to ensure consistent mounting and fixing procedures during EN ISO 11925-2 and EN 13823 testing.
  • Certification bodies and regulators use the standardised test set-up as part of assessment and product classification workflows.
  • Specifiers, architects and installers rely on test-based fire performance data produced using EN 15715 to select suitable thermal insulation for building envelopes, façades, roofs and services insulation where reaction-to-fire performance is critical.

Related standards

  • EN ISO 11925-2 - Ignitability (single-flame exposure)
  • EN 13823 - Single Burning Item (SBI) test
  • Often used together with fire classification standards from the EN 13501 family for assigning reaction-to-fire classes.

EN 15715:2009 is essential for ensuring repeatable, reliable reaction-to-fire test results for factory-made thermal insulation products and for translating laboratory data into practical, code-compliant product information.

Relations

Effective Date
05-Aug-2026
Effective Date
22-Jul-2026
Effective Date
04-Feb-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Building products evaluation and certification.

ANAB United States Verified

QAI Laboratories

Building and construction product testing and certification.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 15715:2009 is a standard published by the European Committee for Standardization (CEN). Its full title is "Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products". This standard covers: This standard specifies instructions for mounting and fixing for reaction to fire testing of factory made thermal insulation products.

This standard specifies instructions for mounting and fixing for reaction to fire testing of factory made thermal insulation products.

EN 15715:2009 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 15715:2009 has the following relationships with other standards: It is inter standard links to EN 13238:2026, EN 312:2010, EN ISO 11925-2:2026, EN 13823:2020+A1:2022, EN 13501-1:2018, EN 13172:2024, EN 13238:2010, EN ISO 9229:2007, EN 508-1:2021, EN ISO 11925-2:2020, EN ISO 1716:2018, EN 13963:2014, EN 520:2004+A1:2009, EN ISO 1182:2020, EN 14305:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 15715:2009 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 15715:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)