Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges

IEC 61010-2-020:2016 is available as IEC 61010-2-020:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61010-2-020:2016 is applicable to electrically powered LABORATORY CENTRIFUGES. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision and includes the following significant changes from the second edition: a) This Part 2 is established on the basis of the third edition (2010) of IEC 61010-1. The changes listed in its foreword affect this Part 2, too. b) The language has been updated to reflect current terminology for LABORATORY CENTRIFUGES used in the industry today. It has the status of a group safety publication in accordance with IEC Guide 104. This publication is to be read in conjunction with IEC 61010-1:2010

Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2-020: Besondere Anforderungen an Laborzentrifugen

Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-020: Exigences particulières pour centrifugeuses de laboratoire

L'IEC 61010-2-020:2016 s'applique aux CENTRIFUGEUSES DE LABORATOIRE alimentées en énergie électrique. Cette troisième édition annule et remplace la deuxième édition parue en 2006. Cette édition constitue une révision technique et inclut les modifications majeures suivantes par rapport à la deuxième édition: a) La présente Partie 2 est établie sur la base de la troisième édition (2010) de l'IEC 61010-1. Les modifications énumérées dans son Avant-propos affectent également la présente Partie 2. b) Le langage a été mis à jour pour refléter la terminologie des CENTRIFUGEUSES DE LABORATOIRE utilisée actuellement dans l'industrie. Elle a le statut d'une publication groupée de sécurité conformément au Guide IEC 104. Cette publication doit être lue conjointement avec la IEC 61010-1:2010

Varnostne zahteve za električno opremo za meritve, nadzor in laboratorijsko uporabo - 2-020. del: Posebne zahteve za laboratorijske centrifuge (IEC 61010-2-020:2016)

Ta 2. del se uporablja za električne LABORATORIJSKE CENTRIFUGE.
Ta publikacija skupinske varnosti se uporablja predvsem kot standard o varnosti izdelka za izdelke, ki so omenjeni v okviru publikacije, vendar je namenjena tudi tehničnim odborom pri pripravi publikacij za izdelke, ki so podobni izdelkom, omenjenim v okviru tega standarda, skladno z načeli vodil IEC 104 in ISO/IEC 51.

General Information

Status
Published
Publication Date
27-Apr-2017
Current Stage
6060 - Document made available - Publishing
Start Date
28-Apr-2017
Completion Date
28-Apr-2017

Relations

Buy Standard

Standard
EN 61010-2-020:2017
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2017
1DGRPHãþD
SIST EN 61010-2-020:2007
9DUQRVWQH]DKWHYH]DHOHNWULþQRRSUHPR]DPHULWYHQDG]RULQODERUDWRULMVNR
XSRUDERGHO3RVHEQH]DKWHYH]DODERUDWRULMVNHFHQWULIXJH ,(&

Safety requirements for electrical equipment for measurement, control, and laboratory
use - Part 2-020: Particular requirements for laboratory centrifuges (IEC 61010-2-
020:2016)
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2
-020: Besondere Anforderungen an Laborzentrifugen (IEC 61010-2-020:2016)
Règles de sécurité pour appareils électriques de mesurage, de régulation et de
laboratoire - Partie 2-020: Exigences particulières pour centrifugeuses de laboratoire
(IEC 61010-2-020:2016)
Ta slovenski standard je istoveten z: EN 61010-2-020:2017
ICS:
19.080 (OHNWULþQRLQHOHNWURQVNR Electrical and electronic
SUHVNXãDQMH testing
71.040.10 Kemijski laboratoriji. Chemical laboratories.
Laboratorijska oprema Laboratory equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61010-2-020

NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2017
ICS 19.080; 71.040.10 Supersedes EN 61010-2-020:2006
English Version
Safety requirements for electrical equipment for measurement,
control, and laboratory use - Part 2-020: Particular requirements
for laboratory centrifuges
(IEC 61010-2-020:2016)
Règles de sécurité pour appareils électriques de mesurage, Sicherheitsbestimmungen für elektrische Mess-, Steuer-,
de régulation et de laboratoire - Partie 2-020: Exigences Regel- und Laborgeräte - Teil 2-020: Besondere
particulières pour centrifugeuses de laboratoire Anforderungen an Laborzentrifugen
(IEC 61010-2-020:2016) (IEC 61010-2-020:2016)
This European Standard was approved by CENELEC on 2016-07-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61010-2-020:2017 E

European foreword
The text of document 66/542/CDV, future edition 3 of IEC 61010-2-020, prepared by IEC/TC 66
"Safety of measuring, control and laboratory equipment" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN 61010-2-020:2017.
The following dates are fixed:
(dop) 2017-10-28
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
• latest date by which the national standards conflicting with (dow) 2020-04-28
the document have to be withdrawn

This document supersedes EN 61010-2-020:2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
Endorsement notice
The text of the International Standard IEC 61010-2-020:2016 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standards indicated:
Addition
IEC 60034 (series) NOTE Harmonized as EN 60034 (series).

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Addition
Publication Year Title EN/HD Year
ISO 3864 series Graphical symbols - Safety colours and - series
safety signs - Part 1: Design principles for
safety signs and safety markings

IEC 61010-2-020 ®
Edition 3.0 2016-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
GROUP SAFETY PUBLICATION
PUBLICATION GROUPÉE DE SÉCURITÉ

Safety requirements for electrical equipment for measurement, control, and

laboratory use –
Part 2-020: Particular requirements for laboratory centrifuges

Exigences de sécurité pour appareils électriques de mesurage, de régulation et

de laboratoire –
Partie 2-020: Exigences particulières pour centrifugeuses de laboratoire

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 19.080, 71.040.10 ISBN 978-2-8322-3398-6

– 2 – IEC 61010-2-020:2016  IEC 2016
CONTENTS
FOREWORD . 3
1 Scope and object . 5
2 Normative references. 6
3 Terms and definitions . 6
4 Tests . 8
5 Marking and documentation . 8
6 Protection against electric shock . 11
7 Protection against mechanical HAZARDS . 11
8 Mechanical resistance to shock and impact . 17
9 Protection against the spread of fire . 17
10 Equipment temperature limits and resistance to heat . 17
11 Protection against HAZARDS from fluids . 17
12 Protection against radiation, including laser sources, and against sonic and
ultrasonic pressure . 19
13 Protection against liberated gases and substances, explosion and implosion . 19
14 Components . 19
15 Protection by interlocks . 19
16 Hazards resulting from application . 19
17 Risk assessment . 19
Annexes . 20
Annex L Index of defined terms . 20
Annex AA (normative) Dynamic microbiological test method for BIOSEALS . 21
Annex BB (informative) General guidance and rationale for particular subclauses . 24
Annex CC (informative) General guidance for an empirical method to determine the
kinetic energy of a ROTOR . 28
Bibliography . 30

Figure 101 – Rotor test setup . 28

Table 101 – Time-temperature conditions . 18

IEC 61010-2-020:2016  IEC 2016 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR
MEASUREMENT, CONTROL, AND LABORATORY USE –

Part 2-020: Particular requirements for LABORATORY CENTRIFUGES

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61010-2-020 has been prepared by IEC technical committee 66:
Safety of measuring, control and laboratory equipment.
This third edition cancels and replaces the second edition published in 2006. It constitutes a
technical revision and includes the following significant changes from the second edition:
a) This Part 2 is established on the basis of the third edition (2010) of IEC 61010-1.The
changes listed in its foreword affect this Part 2, too.
b) The language has been updated to reflect current terminology for LABORATORY
CENTRIFUGES used in the industry today.
It has the status of a group safety publication in accordance with IEC Guide 104.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.