EN 62817:2015/A2:2026
(Amendment)Photovoltaic systems - Design qualification of solar trackers
- Status
- Published
- Publication Date
- 12-Nov-2026
- Technical Committee
- CLC/TC 82 - Solar photovoltaic energy systems
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 13-Nov-2026
- Due Date
- 30-Apr-2026
- Completion Date
- 30-Apr-2026
EN 62817:2015/A2:2026 is the CLC amendment to the European standard on photovoltaic systems - design qualification of solar trackers. It updates the requirements and test methods used to specify, design, qualify and document solar trackers for PV applications, mainly for manufacturers, project engineers, test laboratories and buyers who need a common technical basis.
What does EN 62817:2015/A2:2026 specify?
EN 62817:2015/A2:2026 updates the design-qualification rules for solar trackers used in photovoltaic (PV) systems. The document is organized around normative references, terms and definitions, tracker specifications, environmental conditions, construction requirements, and performance and durability tests.
The amendment focuses on how a solar tracker is specified, built and verified for outdoor PV use. It also makes clear where the standard hands off to project-specific or local requirements, such as site-specific corrosion design, flooding and seismic rules.
The main parts touched by the amendment are Clause 2 on normative references, Clause 3 on terms and definitions, Clause 4 on specifications, Clause 5 on reports, Clause 6 on environmental conditions, Clause 7 on construction, and Clauses 9 to 11 on test methods and accuracy guidance.
A few important limits are explicit in the text:
- The wiring requirements in 7.1.1 do not apply to integral wiring in assemblies, subassemblies and devices already tested to their relevant IEC standard.
- Below-ground corrosion design is left to site-specific geotechnical analysis.
- Snow and wind combined loading is not addressed together; local codes govern combined loads.
What are the key requirements of EN 62817:2015/A2:2026?
EN 62817:2015/A2:2026 tightens the technical basis for tracker design qualification in several areas. The most important points are environmental robustness, electrical and mechanical construction, and the way test results are measured and compared.
Environmental design and site conditions
Clause 6.12 sets a baseline for outdoor service conditions. Solar trackers must at minimum be able to operate and be stored in climatic class 4K26, and Clause 6.12.1 gives a minimum operating temperature range of -20 °C to 50 °C, with wider ranges allowed for hotter or colder sites when justified by the design.
Clause 6.12 also covers humidity, rain, air pressure, flooding, seismic loading, dust/sand, corrosion, EMC, shock and vibration, ingress and electrical supply. In practice, this means the designer has to show that the tracker, its controls and its moving parts can survive the real site climate, not just a laboratory condition.
Corrosion, EMC and ingress protection
Clause 6.12.9 requires corrosion design to be split between below-ground and above-ground exposure. Above ground, the tracker and equipment must at least meet atmospheric corrosion category C2 per ISO 9223 for the design life of the tracker, and the site-specific corrosion environment and service life must be documented.
Clause 6.12.10 requires all solar tracker components to meet EMC immunity and emission requirements for industrial environments. Clause 6.12.12 sets a minimum enclosure protection of IP55 for enclosed tracker components. For the reader, this means corrosion analysis, EMC test evidence and enclosure selection are part of the qualification package, not afterthoughts.
Cables, conductors and wiring
Clause 7.1 adds detailed requirements for conductors, insulation, current-carrying capacity and voltage drop. Copper is the preferred conductor material, flexible conductors used on moving parts should be class 5 or class 6, and power-circuit voltage drop must stay within 5 % under normal operating conditions.
Clause 7.2 then controls how conductors are connected, routed, identified and protected. Protective conductors must be clearly distinguishable, neutral conductors use light blue when color is used, and conductor runs should avoid unnecessary splices or joints. In practice, this reduces heating, wear, wrong connections and maintenance errors.
Motors and control gear
Clause 7.3 requires tracker motors to follow the relevant IEC 60034 series and to have at least IP55 protection, with IP65 or better suggested. Clause 7.4 requires control gear to be mounted for access, maintenance, protection from the environment and safe operation.
The enclosure rules in 7.4 also require at least IP55, appropriate grouping of terminals and devices, and enclosure construction that withstands humidity, thermal stress and mechanical stress. This matters because tracker faults often start in the electrical enclosure rather than in the structure itself.
Test method, payload and acceptance criteria
Clause 6.8.3 revises the payload used for accuracy testing: the tracker is tested with an installed payload, either real modules or weights that reproduce the mass, mass distribution and wind resistance of the modules. Clause 9.4.4.2 revises the torque test to use three wind-loading conditions, including the manufacturer’s stow wind speed or, when there is no stow position, the maximum operational wind speed.
Clauses 9.5 and 9.6 revise environmental cycling and mechanical cycling checks. The amendment also updates the energy-measurement setup when a battery is included, and it requires post-cycling performance to stay close to the pre-cycling results. For a qualification program, that means the test report must show comparable energy use, motion behavior and tracking accuracy before and after endurance exposure.
What terms does EN 62817:2015/A2:2026 define?
- Solar tracker - a PV support system that moves modules so they follow the sun during the day.
- Payload - the installed modules, or equivalent weights, used during testing to represent the real mechanical load and wind resistance.
- Control gear - the electrical control, switching and protective equipment used to operate the tracker.
- Protective conductor / protective bonding conductor - the conductor used to bond exposed conductive parts and carry fault current safely; the document gives specific identification rules for it.
- Neutral conductor - the conductor identified by light blue when color identification is used in a circuit with a neutral.
- Electromagnetic compatibility (EMC) - the ability of tracker equipment to operate without unacceptable disturbance and without creating unacceptable disturbance for other equipment.
- Protective extra-low voltage (PELV) - the low-voltage circuit category used when the document sets reduced insulation test levels.
- Ingress Protection (IP) - the enclosure protection rating used to show resistance to dust and water, such as the minimum IP55 requirement in the document.
Who uses EN 62817:2015/A2:2026?
EN 62817:2015/A2:2026 is used by solar tracker manufacturers, PV system designers, electrical and mechanical engineers, and project developers who need a common basis for tracker qualification. It is also used by test laboratories, certification bodies and quality managers who prepare or review design-qualification testing.
In practice, it supports utility-scale ground-mounted PV projects, specification sheets, factory and type testing, environmental suitability checks, and documentation for installation, maintenance and acceptance.
What changed in EN 62817:2015/A2:2026 from the previous edition?
EN 62817:2015/A2:2026 updates EN 62817:2015 by:
- adding and revising normative references, including IEC 61836, IEC 61800 Series, IEC TS 62738, IEC 60034-1, IEC 60034-5 and several EMC standards
- revising the terms clause to rely on IEC TS 61836 and tracker-specific terminology
- adding an alternate template for presenting accuracy specifications in Clause 4
- deleting the earlier ISO/IEC 17025 report wording in Clause 5
- clarifying payload use for accuracy testing
- expanding environmental-condition requirements in Clause 6.12
- adding construction requirements for cables, wiring, motors and control gear in Clause 7
- revising wind-loading, energy-measurement, cycling and UV-test procedures in Clauses 9 and 10
Which standards are used with EN 62817:2015/A2:2026?
| Standard | What it contributes |
|---|---|
| IEC 61836 | Terms, definitions and symbols for solar photovoltaic energy systems |
| IEC 61800 Series | Requirements for adjustable speed electric DC power drive systems |
| IEC TS 62738 | Design guidelines and recommendations for ground-mounted power plants |
| IEC 60034-1 | Motor rating, performance and thermal protection-related requirements |
| IEC 60034-5 | Motor enclosure and IP classification |
| IEC TR 60890 | Temperature-rise verification by calculation for low-voltage assemblies |
| IEC 60216 Series | Thermal endurance properties of insulating materials |
| IEC 60085 | Thermal evaluation and designation of electrical insulation |
| IEC 61000-6-1 / -6-2 / -6-3 / -6-4 | EMC immunity and emission requirements for residential and industrial environments |
| IEC 60904-3 | Measurement principles for terrestrial PV reference spectral irradiance |
| IEC 61000-4-5 | Surge immunity testing |
| IEC 60529 | IP ratings for enclosures |
| IEC 60721-3-4 | Climatic conditions classification used for outdoor tracker design |
What does the EN 62817:2015/A2:2026 document contain?
EN 62817:2015/A2:2026 contains the amendment text that modifies the base tracker qualification standard, including updated clause text, revised requirements, and revised test procedures. It includes a climatic classification table, conductor size and current-carrying examples, and a bending-radius table for flexible cables.
The document also refers to a climatogram, an idealized torque-versus-displacement plot, and tables used for accuracy specifications and environmental qualification. These parts support design checks, type testing, energy-measurement setups, and verification of mechanical endurance and tracking accuracy.
Relations
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 03-Nov-2026
- Effective Date
- 13-May-2025
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

DNV Energy Systems
Energy and renewable energy certification.
Sponsored listings
Frequently Asked Questions
EN 62817:2015/A2:2026 is a draft published by CLC. Its full title is "Photovoltaic systems - Design qualification of solar trackers". This standard covers: Photovoltaic systems - Design qualification of solar trackers
Photovoltaic systems - Design qualification of solar trackers
EN 62817:2015/A2:2026 is classified under the following ICS (International Classification for Standards) categories: 27.160 - Solar energy engineering. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 62817:2015/A2:2026 has the following relationships with other standards: It is inter standard links to EN IEC 60721-3-4:2019, EN IEC 61000-6-4:2019, EN IEC 60904-3:2019, EN 60204-1:2018/A1:2025, EN IEC 60228:2024, EN 61000-4-5:2014, EN IEC 61000-6-3:2021, EN IEC 60664-1:2020, EN IEC 61000-6-2:2019, EN 60204-1:2018, IEC TS 61836:2016, EN ISO 9223:2012, EN IEC 61000-6-1:2019, EN 62817:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 62817:2015/A2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 62817:2015/oprA2:2026
01-januar-2026
Fotonapetostni sistemi - Osnova zasnove sledilnikov sonca - Dopolnilo A2
Amendment 2 - Photovoltaic systems - Design qualification of solar trackers
Sonnen-Nachführeinrichtungen für photovoltaische Systeme - Bauarteignung
Systèmes photovoltaïques - Qualification de conception des suiveurs solaires
Ta slovenski standard je istoveten z: EN 62817:2015/prA2:2025
ICS:
27.160 Sončna energija Solar energy engineering
SIST EN 62817:2015/oprA2:2026 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 62817:2015/oprA2:2026
SIST EN 62817:2015/oprA2:2026
82/2507/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 62817/AMD2 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2025-11-14 2026-02-06
SUPERSEDES DOCUMENTS:
82/2420/CD, 82/2470A/CC
IEC TC 82 : SOLAR PHOTOVOLTAIC ENERGY SYSTEMS
SECRETARIAT: SECRETARY:
United States of America Mr George Kelly
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the
final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Amendment 2 - Photovoltaic systems - Design qualification of solar trackers
PROPOSED STABILITY DATE: 2030
NOTE FROM TC/SC OFFICERS:
This project was discussed and supported by WG9 during their meeting in 2025-05.
[Type here] -1- IEC 62817-1 ED1 AM2
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION
2 ____________
4 PHOTOVOLTAIC SYSTEMS –
6 Design qualification of Solar Trackers
8 AMENDMENT 2
10 FOREWORD
11 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
12 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
13 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
14 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
15 Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
16 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
17 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
18 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
19 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
20 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
21 consensus of opinion on the relevant subjects since each technical committee has representation from all
22 interested IEC National Committees.
23 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
24 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
25 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
26 misinterpretation by any end user.
27 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
28 transparently to the maximum extent possible in their national and regional publications. Any divergence between
29 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
30 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
31 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
32 services carried out by independent certification bodies.
33 6) All users should ensure that they have the latest edition of this publication.
34 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
35 members of its technical committees and IEC National Committees for any personal injury, property damage or
36 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
37 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
38 Publications.
39 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
40 indispensable for the correct application of this publication.
41 9) [IEC/IEC and ISO] [draws/draw] attention to the possibility that the implementation of this document may involve
42 the use of (a) patent(s). [IEC/IEC and ISO] [takes/take] no position concerning the evidence, validity or
43 applicability of any claimed patent rights in respect thereof. As of the date of publication of this document,
44 [IEC/IEC and ISO] [had/had not] received notice of (a) patent(s), which may be required to implement this
45 document. However, implementers are cautioned that this may not represent the latest information, which may
46 be obtained from the patent database available at https://patents.iec.ch [and/or] www.iso.org/patents. [IEC/IEC
47 and ISO] shall not be held responsible for identifying any or all such patent rights.
48 Amendment 2 to IEC 62817-1:2014 has been prepared by subcommittee TC 82: Solar
49 photovoltaic energy systems.
50 The text of this Amendment is based on the following documents:
Draft Report on voting
82/2420/CD 82/2470A/CC
52 Full information on the voting for its approval can be found in the report on voting indicated in
53 the above table.
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
54 The language used for the development of this Amendment is English.
55 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
56 accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement,
57 available at www.iec.ch/members_experts/refdocs. The main document types developed by
58 IEC are described in greater detail at www.iec.ch/publications/.
59 The committee has decided that the contents of this document will remain unchanged until the
60 stability date indicated on the IEC website under webstore.iec.ch in the data related to the
61 specific document. At this date, the document will be
62 – reconfirmed,
63 – withdrawn, or
64 – revised.
65 ___________
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
66 PHOTOVOLTAIC SYSTEMS –
67 DESIGN QUALIFICATION OF SOLAR TRACKERS
68 2 Normative references
69 ADD:
70 IEC 61836:2016, Solar photovoltaic energy systems - Terms, definitions and symbols
71 IEC 61800 Series, Adjustable speed electric DC power drive systems
72 IEC TS 62738:2018, Ground-mounted power plants – Design guidelines and
73 recommendations
74 IEC 60034-1:3022, Rotating Electrical machines – Part 1: Rating and performance
75 IEC 60034-5:2020, Rotating electrical machines - Part 5: Degrees of protection provided by
76 the integral design of rotating electrical machines (IP code) - Classification
77 IEC TR 60890:2022, A method of temperature-rise verification of low-voltage switchgear and
78 control-gear assemblies by calculation
79 IEC 60216 Series, determining the thermal endurance properties of electrical insulating
80 materials and simple combinations
81 IEC 60085:2007, Electrical insulation - Thermal evaluation and designation
82 IEC 61000-6-1:2016, Electromagnetic compatibility (EMC) - Part 6-1: Generic standards -
83 Immunity standard for residential, commercial and light-industrial environments
84 IEC 61000-6-2:2016, Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
85 Immunity standard for industrial environments
86 IEC 61000-6-3:2020, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards -
87 Emission standard for equipment in residential environments
88 IEC 61000-6-4:2018, Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -
89 Emission standard for industrial environments
90 REVISE DATED REFERENCES:
91 IEC 60904-3: 2019, Photovoltaic devices – Part 3: Measurement principles for terrestrial photovoltaic
92 (PV) solar devices with reference spectral irradiance data
93 IEC 61000-4-5: 2014, Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement
94 techniques – Surge immunity test
95 DELETE:
96 ISO/IEC 17025, General requirements for the competence of testing and calibration
97 laboratories
98 3 Terms and definitions
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
99 Revise first sentence:
100 For the purposes of this document, the following terms and definitions in IEC TS 61836 and the
101 following apply. For additional tracker-specific terminology, see Clause 6.
102 4 Specifications for solar trackers for PV applications
103 ADD the following text after Table 1:
104 For an alternate template for the presentation of accuracy specifications, see Table 6 in
105 clause 8.4.
106 5 Report
107 DELETE the following text:
108 A certified report of the qualification tests, with measured performance characteristics and
109 details of any failures and re-tests, shall be prepared. by the test agency in accordance with
110 ISO/IEC 17025. The report shall contain the specification sheet per Table 1.
111 6.8.3 Payload
112 REVISE the following text:
113 Accuracy testing (detailed in 7.4.6 8.4) will be carried out with an installed payload, either an array
114 of actual modules or an array of weights that simulate the mass, mass distribution, and wind
115 resistance of these modules.
116 6.12 Environmental conditions
117 ADD:
119 Solar trackers must be suitable for a wide range of outdoor environmental and climatic conditions. While
120 it is impossible to identify all combinations of the physical environment and operating conditions that
121 may be encountered at solar tracker installations, a framework for the definition of global environmental
122 conditions is presented in the IEC 60721 series of standards.
123 Each of the subcomponents should be chosen to meet related requirements within their relevant
124 standards for below operating conditions.
125 At a minimum, solar trackers must be capable of operation and storage in climatic conditions classified
126 as 4K26, in accordance with IEC 60721-3-4. Specifications for solar trackers may exceed these
127 minimum requirements as appropriate or necessary for the installed location, in particular, for hot or cold
128 weather environments.
129 6.12.1 to 6.12.20 specify additional requirements or modifications to the 4K26 classification, if any,
130 related to individual environmental parameters.
131 Table 2 - Classifications of climatic conditions
Classification
Environmental parameter Unit Sheltered Open-air
4K23 4K24 4K25 4K26 4K27
Low air temperature °C −45 −50 +5 −20 -50
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
Classification
Environmental parameter Unit Sheltered Open-air
4K23 4K24 4K25 4K26 4K27
i i i
°C +70 +70
High air temperature +45 +50 +45
a
% 4 4 30 4 10
Low relative humidity
a
% 100 100 100 100 100
High relative humidity
a 3
0,2 0,003 6 0,1 0,003
Low absolute humidity g/m
a 3
35 20 35 30 25
High absolute humidity g/m
b
°C/min 1,0 1,0 1,0 1,0 1,0
Rate of change of temperature
c
kPa 70 70 70 70 70
Low air pressure
c
kPa 106 106 106 106 106
High air pressure
l l l
h h
1 090 1 090 1 090
Solar radiation W/m
f f
Heat radiation Not specified No No No
d d, f d, f f f f
m/s
Movement of surrounding air 5,0 5,0 22 22 22
Condensation Not specified Yes Yes Yes Yes Yes
m g g
Not specified Yes Yes Yes
Precipitation (rain, snow, hail, etc.) Yes Yes
g g
mm/min 15 15 15
Rain intensity No No
Driving rain m/s No No 18 18 18
2 g g
No No No
Snow load kg/m
e g g
°C +5 +5 +5
Low rain temperature No No
j j j
Not specified Dripping Dripping
Water from sources other than rain
water water
k k k
Not specified Yes Yes
Formation of ice and frost
Yes Yes Yes
a
The low and high relative humidity levels are limited by the low and high absolute humidity.
b
Averaged over a period of 5 min.
c
The value of 70 kPa represents a limit for open-air conditions, normally at an altitude of 3 000 m. In some
geographical areas, open-air conditions may occur at higher altitudes. Conditions in mines are not considered.
If applicable, a special value may be selected from IEC 60721-3-4, Table 2.
d
A cooling system based on non-assisted convection may be disturbed by adverse movement of surrounding air.
e
This rain temperature should be considered together with high air temperature and solar radiation. The cooling
effect of the rain should be considered in connection with the surface temperature of the product.
f
If applicable, a special value may be selected from IEC 60721-3-4, Table 2.
g
Applies only to wind-driven precipitation at sheltered locations.
h
Thermal effect of solar radiation is included in the temperature.
i
Thermal effect of solar radiation is not included in the temperature.
j
Sources of water other than rain are encompassed in driving rain.
k
Formation of frost can occur due to heat radiation to a clear sky.
l
From sea level.
m
See IEC 60721-2-2 for additional information.
133 6.12.1 Operating temperature range
134 ADD:
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
136 All solar tracker systems and components shall be designed for a temperature range of -20˚C to 50˚
137 C at minimum.
138 The upper-temperature limit may also be increased up to 65˚C for products to be deployed in Arid and
139 equatorial regions, and the low-temperature limit may be reduced up to -40˚C for colder sites. This
140 may be accomplished by means of design or by additional equipment (E.g., adding heater elements
141 to enhance battery performance, or replacing with alternate or redundant power sources such as AC
142 from inverter, grid, active cooling components etc.).
143 ADD:
145 6.12.3 Humidity
146 Absolute air humidity range, minimum: 0,1 to 30 g/m
147 Relative air humidity range, minimum: 4% to 100% considering the interdependence of air temperature
148 and absolute air humidity according the Climatogram below (Referenced from IEC 60721-3-4).
149 Figure 1: Climatogram showing interdependence of air temperature and absolute air humidity.
151 6.12.4 Rain
152 Rain intensity, minimum: 15 mm/h
153 Wind Borne Rain velocity, minimum: 18 m/s
154 6.12.5 Air pressure (altitude)
155 Air pressure range, minimum: 79,5 kPa to 106 kPa (2,000 m to -400 m)
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
156 For solar tracker installations at altitudes higher than 2,000 m, it may be necessary to account for
157 reduced air density in the calculations of dielectric strength, cooling effect and switching capability of
158 devices.
159 6.12.6 Flooding
160 Requirements to accommodate flooding are highly localized and determined on a site-specific basis. At
161 a minimum, electrical components are to be mounted higher than the peak expected flood level.
162 Particular attention shall be given to site hydrology considerations such as drainage and grading while
163 planning the foundation design.
164 6.12.7 Seismic (earthquake)
165 The system shall be designed to tolerate seismic shocks. Seismic (earthquake) requirements are
166 defined by local codes. Seismic retainer fasteners should be used for impacted sites and component
167 designs.
168 6.12.8 Dust/sand
169 Performance of tracker controls and moving components can be affected by dust and sand. Section
170 9.5.2 (a) and section 10.2.4 identify test requirements that include dust exposure testing.
171 6.12.9 Corrosion
172 Tracker components can experience different corrosion environments depending on their location. Piles
173 and foundations that penetrate the ground are subject to below ground corrosion mechanisms and
174 components above the ground experiences above ground corrosion. Each of these are treated
175 separately:
176 6.12.9.1 Below Ground Corrosion:
177 Requirements for corrosion design of below ground foundations are not covered in this standard as the
178 corrosion design for below ground corrosion needs to be tailored for the local site-specific conditions
179 based on a detailed geotechnical analysis. However, the scope of geotechnical studies should include
180 the following at a minimum to gather a comprehensive dataset for proper corrosion design.
181 1. Soil resistivity, corrosivity, aeration
182 2. Redox potential
183 3. pH, Sulphates, Sulfides, Chlorides,
184 The design life of the power plants is typically in the range of 25 to 50 years and the engineer of record
185 design shall document the approved design life from the project developer. Appropriate design using
186 coatings, sacrificial steel or a combination of both is allowed. Bare steel (black steel) designs are not
187 excluded from consideration for corrosion engineers.
188 The findings of the corrosion analysis shall consider inputs from the geotechnical analysis, and the
189 corrosion design reviewed and certified by a licensed geotechnical engineer with corrosion experience.
190 Trackers foundations are custom designed for the local site corrosion environment. The site specific
191 below ground design environment (Ex C2) and service life shall be identified in the site-specific product
192 documentation.
193 6.12.9.2 Above Ground Corrosion:
194 There are multiple parameters that influence atmospheric corrosivity above ground, but the three most
195 important are as follows:
SIST EN 62817:2015/oprA2:2026
IEC CDV 62817/AMD2 © IEC 2025
196 ▪ Time of wetness.
197 ▪ Atmospheric chloride content (salinity).
198 ▪ Atmospheric sulfur dioxide content.
200 Iron and steel parts shall be protected against corrosion by enameling, galvanizing, plating, sacrificial
201 corrosion coatings, painting or other equivalent means. This applies to all framing, fasteners, springs
202 and other parts which are relied upon for the intended mechanical operation.
204 At a minimum, solar trackers and equipment shall be designed to resist atmospheric corrosion category,
205 C2 per ISO 9223 Corrosivity of atmospheres – classification, determination, and estimation for the
206 design life of the tracker. Specifications for solar trackers may exceed these minimum requirements as
207 appropriate or necessary for the installed location, particularly in high-corrosion environments.
208 The design life of the power plants is typically in the range of 25 to 50 years and the engineer of record
209 design shall document the approved design life from the project developer. The findings of the corrosion
...