Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder

Compatibilité électromagnétique (CEM) - Partie 4-3: Techniques d'essai et de mesure - Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques

Elektromagnetna združljivost (EMC) - 4-3. del: Preskusne in merilne tehnike - Preskušanje odpornosti proti sevanim radiofrekvenčnim elektromagnetnim poljem (IEC 61000-4-3:2006/A1:2007)

General Information

Status
Withdrawn
Publication Date
12-Feb-2008
Withdrawal Date
31-Jan-2011
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Oct-2023
Completion Date
13-Oct-2023

Relations

Buy Standard

Amendment
EN 61000-4-3:2006/A1:2008
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61000-4-3:2006/A1:2008
01-junij-2008
(OHNWURPDJQHWQD]GUXåOMLYRVW (0& GHO3UHVNXVQHLQPHULOQHWHKQLNH
3UHVNXãDQMHRGSRUQRVWLSURWLVHYDQLPUDGLRIUHNYHQþQLPHOHNWURPDJQHWQLPSROMHP
,(&$
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test
Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung
der Störfestigkeit gegen hochfrequente elektromagnetische Felder
Compatibilité électromagnétique (CEM) - Partie 4-3: Techniques d'essai et de mesure -
Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences
radioélectriques
Ta slovenski standard je istoveten z: EN 61000-4-3:2006/A1:2008
ICS:
33.100.20 Imunost Immunity
SIST EN 61000-4-3:2006/A1:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 61000-4-3/A1

NORME EUROPÉENNE
February 2008
EUROPÄISCHE NORM

ICS 33.100.20


English version


Electromagnetic compatibility (EMC) -
Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test
(IEC 61000-4-3:2006/A1:2007)


Compatibilité électromagnétique (CEM) -  Elektromagnetische Verträglichkeit (EMV) -
Partie 4-3: Techniques d'essai Teil 4-3: Prüf- und Messverfahren -
et de mesure - Prüfung der Störfestigkeit gegen
Essai d'immunité aux champs hochfrequente elektromagnetische Felder
électromagnétiques rayonnés (IEC 61000-4-3:2006/A1:2007)
aux fréquences radioélectriques
(CEI 61000-4-3:2006/A1:2007)




This amendment A1 modifies the European Standard EN 61000-4-3:2006; it was approved by CENELEC on
2008-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-4-3:2006/A1:2008 E

---------------------- Page: 2 ----------------------

EN 61000-4-3:2006/A1:2008 - 2 -
Foreword
The text of document 77B/546/FDIS, future amendment 1 to IEC 61000-4-3:2006, prepared by SC 77B,
High frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 61000-4-3:2006
on 2008-02-01.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
(dop) 2008-11-01
an identical national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2011-02-01
with the amendment have to be withdrawn
__________
Endorsement notice
The text of amendment 1:2007 to the International Standard IEC 61000-4-3:2006 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________

---------------------- Page: 3 ----------------------

IEC 61000-4-3
Edition 3.0 2007-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Electromagnetic compatibility (EMC) –
Part 4-3: Testing and measurement techniques – Radiated, radio-frequency,
electromagnetic field immunity test

Compatibilité électromagnétique (CEM) –
Partie 4-3: Techniques d’essai et de mesure – Essai d’immunité aux champs
électromagnétiques rayonnés aux fréquences radioélectriques

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
R
CODE PRIX
ICS 33.100.20 ISBN 2-8318-9354-2

---------------------- Page: 4 ----------------------

– 2 – 61000-4-3 Amend.1 © IEC:2007
FOREWORD
This amendment ha
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.