EN IEC 63086-2-2:2026
(Main)Household and similar electrical air cleaning appliances - Method for measuring the performance - Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
- Status
- Published
- Publication Date
- 12-Nov-2026
- Technical Committee
- CLC/TC 59X - Performance of household and similar electrical appliances
- Drafting Committee
- TC 59 - Performance of household and similar electrical appliances
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 13-Nov-2026
- Due Date
- 30-Dec-2024
- Completion Date
- 30-Dec-2024
EN IEC 63086-2-2:2026 is a CLC standard for measuring the performance of household and similar electrical air cleaning appliances. It specifies how to determine reduction of gas-phase pollutants in a test chamber, including the test gases, measurement methods, calculations, and reporting needed to compare devices. The document is for laboratories, manufacturers, and other users who need repeatable gas-phase air-cleaner performance data.
What does EN IEC 63086-2-2:2026 specify?
EN IEC 63086-2-2:2026 specifies test methods for electrically powered household and similar air cleaners intended to reduce gas-phase pollutants. It focuses on measuring reduction of specific gases in a controlled chamber, not on odour intensity testing.
The document is organized into 9 clauses and 7 annexes:
- Clause 1 gives the scope.
- Clause 2 lists the normative references.
- Clause 3 defines the key terms and abbreviations.
- Clauses 4 to 7 cover test gases, measurement methods, gas generation, and the test chamber.
- Clauses 8 and 9 cover the natural decay test, total decay test, data treatment, and CADR calculation.
| Annex | What it covers |
|---|---|
| A | Representative and optional test gases, plus alternative instruments |
| B | Calculation of the 99 % prediction interval of the regression line |
| C | Test report information |
| D | Background concentration and initial concentration |
| E | Limits of measurability |
| F | Schematic representation of a CADR measurement |
| G | Particular requirements for ozone reduction |
What are the key requirements of EN IEC 63086-2-2:2026?
EN IEC 63086-2-2:2026 sets out a complete chamber test sequence for gas-phase performance. The most important requirements are the choice of test gas, the measurement method for that gas, the way the chamber is prepared, and the way decay data are accepted and converted into clean air delivery rate (CADR).
Test gases and measurement methods
- Clause 4 defines six representative test gases: formaldehyde, toluene, n-heptane, d-limonene, ammonia, and nitrogen dioxide. In practice, a lab chooses the gas or gases that match the pollutant class it wants to claim performance against.
- Clause 4 also allows optional gases listed in Annex A, and it allows parallel testing only when gases do not react with each other or change the performance of the technology under test. This matters because incompatible gases can distort the measured result or force a repeat test.
- Clause 5 assigns the measurement approach for each gas and allows an alternative method when it has equivalent or better accuracy. Formaldehyde uses DNPH sampling and HPLC, while toluene, n-heptane, and d-limonene use sorbent tubes with GC/MS or GC/FID, with SIFT-MS allowed as an alternative in the stated cases.
Test chamber and gas generation
- Clause 6 allows two ways to generate the initial gas concentration: the gas cylinder method or the temperature-controlled vaporization method. The method has to deliver the initial concentration required for the selected gas.
- Clause 7 keeps the chamber aligned with IEC 63086-1 and adds a requirement for the wall-mounted recirculation fan. That fan condition is important because it helps keep the chamber mixed so the decay measurements are consistent.
- Clause 7 also ties the chamber conditions to the general air cleaner test setup in IEC 63086-1. In practice, the test lab must use a chamber that meets the base standard and then apply this part’s extra fan requirement.
Natural decay, total decay, and CADR
- Clause 8 requires two runs: a natural decay test without the DUT and a total decay test with the DUT operating in maximum performance operation mode. The natural decay run establishes the chamber baseline, and the total decay run shows the chamber plus device performance.
- Clause 8 requires chamber cleaning, stable temperature and relative humidity, controlled gas emission, and initial concentration checks before the decay run starts. If the concentration is outside the required range, the run is terminated.
- Clause 8 also requires the DUT to be switched on from outside the chamber, by remote operation, remote-controlled power supply, or a robotic setup. That avoids disturbing the chamber conditions at the start of the test.
Data acceptance and calculations
- Clause 9 rejects outliers outside the 99 % prediction interval of the regression line, and it also removes later data points once the concentration falls below 3 % of the initial concentration. This protects the calculation from points that no longer represent the decay process well.
- Clause 9 calculates the decay constant from a linear regression of the logarithm of concentration versus time, then derives CADR from the chamber volume and the difference between total decay and natural decay. For the reader, this means the reported CADR is not a direct measurement from one instrument reading but a calculated performance value.
- Clause 9 uses the sample standard deviation of the regression slope to judge run acceptability, and Annex E defines the measurability limits. In practice, the lab must confirm that the test data are stable enough and that the resulting CADR falls within the measurable range of the method.
Ozone reduction
- Annex G gives special requirements for ozone. Ozone is measured by UV absorption spectrometer, generated by an ozone generator, tested alone, and given its own background and variability limits. That matters because ozone is highly reactive and can affect other gases if tested in sequence.
What terms does EN IEC 63086-2-2:2026 define?
EN IEC 63086-2-2:2026 defines the core terms used in the chamber test and calculation steps.
- Gas-phase pollutants - gaseous compounds found indoors from outdoor air, human activities, or materials brought into the home.
- Test gases - the selected gas-phase pollutants used for air-cleaner performance measurement.
- Background concentration - the concentration in the chamber after cleaning and before test gas is added.
- Initial concentration - the concentration at the start of sampling for the natural decay or total decay run.
- Natural decay rate - the reduction rate caused by natural factors such as adsorption, chemical reaction, and air exchange.
- Total decay rate - the reduction rate caused by natural factors plus operation of the DUT.
- CADR (clean air delivery rate) - the flow rate of clean air delivered by the DUT, calculated from decay rate and chamber volume.
- Maximum performance operation mode - the manual mode in which the DUT is set to the highest flow rate with all air-cleaning functions on, where applicable.
Who uses EN IEC 63086-2-2:2026?
EN IEC 63086-2-2:2026 is used by test laboratories, appliance manufacturers, and conformity assessment bodies that measure gas-phase air-cleaner performance. Quality managers and product engineers use it to set up tests, compare technologies, and document results in a consistent way.
It is also relevant to buyers, certification teams, and technical reviewers who need to interpret reported CADR values for specific gases. The document helps them understand what was tested, how the test was run, and whether the result applies to a particular gas or product configuration.
What changed in EN IEC 63086-2-2:2026 from the previous edition?
EN IEC 63086-2-2:2026 is identified as identical with prEN IEC 63086-2-2:2025, and it supersedes documents 59N/39/CD and 59N/67/CC.
Which standards are used with EN IEC 63086-2-2:2026?
EN IEC 63086-2-2:2026 relies on a small set of companion standards and sampling methods.
- IEC 63086-1:2020 - provides the general requirements and shared definitions for household and similar electrical air cleaning appliances, including the base terms for air cleaner, DUT, test chamber, and CADR.
- IEC 63086-2-1:2024 - provides the companion method for determination of reduction of particles, and it is referenced for the measurability framework used here.
- ISO 16000-3 - provides the formaldehyde sampling and analysis method used for this part.
- ISO 16000-6 - provides the VOC sampling and analysis method used for toluene, n-heptane, and d-limonene.
- ISO 16000-9 - supports chamber-based methods used for cleaning and background control, and it is also referenced for TVOC-related work.
What does the EN IEC 63086-2-2:2026 document contain?
EN IEC 63086-2-2:2026 contains the test logic, calculation methods, and reporting structure needed to measure gas-phase pollutant reduction. It does not just name the gases - it also gives the chamber setup, decay-test sequence, regression treatment, and CADR calculation.
The document includes:
- Table 1 with the representative test gases.
- Table 2 with target background concentration levels.
- Tables 3 and 4 with acceptability limits for the sample standard deviation of the regression slope.
- Annex A with optional gases and alternative instruments.
- Annex B with the 99 % prediction interval method and t-values.
- Annex C with test report information.
- Annex D with guidance on background and initial concentration.
- Annex E with limits of measurability.
- Annex F with a schematic of the CADR measurement.
- Annex G with ozone-specific requirements.
Relations
- Effective Date
- 27-Oct-2026
- Effective Date
- 27-Oct-2026
- Effective Date
- 27-Oct-2026
- Effective Date
- 27-Oct-2026
- Effective Date
- 27-Oct-2026
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
EN IEC 63086-2-2:2026 is a draft published by CLC. Its full title is "Household and similar electrical air cleaning appliances - Method for measuring the performance - Part 2-2: Particular requirements for determination of gas-phase pollutant reduction". This standard covers: Household and similar electrical air cleaning appliances - Method for measuring the performance - Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
Household and similar electrical air cleaning appliances - Method for measuring the performance - Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
EN IEC 63086-2-2:2026 is classified under the following ICS (International Classification for Standards) categories: 23.120 - Ventilators. Fans. Air-conditioners; 97.080 - Cleaning appliances. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 63086-2-2:2026 has the following relationships with other standards: It is inter standard links to EN IEC 63086-2-1:2024, ISO 16000-6:2021, EN ISO 16000-9:2024, ISO 16000-3:2022, EN IEC 63086-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 63086-2-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms
- 3.1 Terms and definitions
- 3.1.1 gas-phase pollutants
- 3.1.2 test gases
- 3.1.3 natural decay rate
- 3.1.4 total decay rate
- 3.1.5 background concentration
- 3.1.6 initial concentration
- 3.1.7 TVOC
- 3.1.8 real-time measurement method
- 3.1.9 non-real-time measurement method
- 3.2.1 air cleaner
- 3.2.2 robotic air cleaner
- 3.2.3 fresh-air air cleaner
- 3.2.4 combination products
- 3.2.5 DUT
- 3.2.6 test chamber
- 3.2.7 target pollutant
- 3.2.8 operation decay rate
- 3.2.9 CADR
- 3.2.10 automatic operation mode
- 3.2.11 manual operation mode
- 3.2.12 maximum performance operation mode
- 3.2.13 energy efficiency in maximum performance operation mode
- 3.3 Abbreviated terms
- 4 Test gases and initial concentrations for testing
- 4.1 General
- 4.2 Representative test gases
- 5 Measurement method for test gas concentration
- 5.1 General
- 5.2 Measurement and analysis method for formaldehyde
- 5.3 Measurement and analysis method for toluene, n-heptane, and d-limonene
- 5.4 Measurement and analysis method for ammonia
- 5.5 Measurement and analysis method for nitrogen dioxide
- 6 Generation of initial gas concentrations
- 6.1 General
- 7 Test chamber
- 8 Measurement of the CADR in maximum performance operation mode
- 8.1 General
- 8.2 Natural decay test
- 8.3 Total decay test
- 8.4 Calculation of the clean air delivery rate
- 9 Calculation Procedures
- 9.1 Criteria for the acceptance of data points
- 9.2 Calculation of decay constants
- 9.3 Sample standard deviation of the slope of the regression line
- 9.4 Calculation of the clean air delivery rate
- 9.5 Sample standard deviation of the clean air delivery rate
- Annex A
- Annex B
- Annex C
- Annex D
- Annex E
- Annex F
- Annex G
- Bibliography
INTRODUCTION The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent. IEC takes no position concerning the evidence, validity, and scope of this patent right. The holder of this patent right has assured IEC that s/he is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. Information may be obtained from the patent database available at patents.iec.ch/. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those in the patent database. IEC shall not be held responsible for identifying any or all such patent rights.
oSIST prEN IEC 63086-2-2:2025
Household and similar electrical air cleaning appliances - Method for measuring performance - Part 2-2: Particular requirements for determination of gas-phase pollutant reduction –
1 Scope
This part of IEC 63086 specifies test methods for measuring the performance of electrically powered household and similar air cleaners intended for the reduction of gas-phase pollutants. This document is intended for measuring the reduction of the concentration of specific gasphase pollutants. This does not necessarily correlate with the reduction of odour intensity in the case of odorous gas-phase pollutants. Such a reduction can only be tested by olfactory tests, which are not part of this document.
NOTE Test methods for the determination of possible gas-phase by-products are under consideration.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 63086-1:2020, Household and similar electrical air cleaning appliances - Methods for measuring the performance - Part 1: General requirements IEC 63086-2-1:2024, Household and similar electrical air cleaning appliances - Methods for measuring the performance - Part 2-1: Particular requirements for determination of reduction of particles ISO 16000-3, Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method ISO 16000-6, Indoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MSFID ISO 16000-9, Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 63086-1:2020 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1.1 gas-phase pollutants
gaseous compounds that can be found in residential dwellings either from entrance from the outside, from human activities in dwelling, or from materials brought into the home
oSIST prEN IEC 63086-2-2:2025
3.1.2 test gases
selected gas-phase pollutants for measuring the performance of air cleaners
3.1.3 natural decay rate
reduction rate of target test gas in the test chamber due to natural factors, surface adsorption, chemical reaction, and air exchange −1 Note 1 to entry: The unit is per hour (h ).
3.1.4 total decay rate
reduction rate of target test gas in the test chamber due to combined effect of the natural decay rate and the operation decay rate −1 Note 1 to entry: The unit is per hour (h ).
3.1.5 background concentration
concentration of test gases in the test chamber after the test chamber has undergone cleaning and prior to any testing or addition of target test gases
3.1.6 initial concentration
concentration of test gases being measured inside the test chamber immediately at the start time of sampling of either the natural decay or the total decay
3.1.7 TVOC
total volatile organic compounds sum of the concentrations of identified and unidentified volatile organic compounds eluting between and including n-hexane and n-hexadecane (in accordance with ISO 16000-9)
3.1.8 real-time measurement method
method to measure the concentration of target test gas with continuous sampling and measurement by instrument such as Chemiluminescence analyser and so on.
3.1.9 non-real-time measurement method
method to measure the concentration of target test gas with non-continuous process of air sampling by sampling device, desorption of chemicals and measurement by instrument such as High Performance Liquid Chromatography (HPLC) and so on.
3.2 Terms defined in IEC 63086-1:2020
3.2.1 air cleaner
electrically powered household, or similar, appliance that employs one or multiple technologies to reduce one or more types of indoor air pollutants [SOURCE: IEC 63086-1:2020, 3.1]
3.2.2 robotic air cleaner
air cleaner that operates and changes its physical location autonomously without user intervention Note 1 to entry: The robotic air cleaner can consist of a part that houses the air cleaning function and can have a docking station and/or other accessories to assist its operation. [SOURCE: IEC 63086-1:2020, 3.2]
oSIST prEN IEC 63086-2-2:2025
3.2.3 fresh-air air cleaner
air cleaner connected to the external environment, which provides pollutant-reduced outdoor air into an indoor space Note 1 to entry: The fresh-air air cleaner can also include other auxiliary functions, such as heat exchange. [SOURCE: IEC 63086-1:2020, 3.3]
3.2.4 combination products
air cleaner that includes a secondary function besides air cleaning within the same housing, such as humidifying, dehumidifying, heating, or air conditioning [SOURCE: IEC 63086-1:2020, 3.4]
3.2.5 DUT
device under test air cleaner undergoing examination [SOURCE: IEC 63086-1:2020, 3.5]
3.2.6 test chamber
self-contained room with determined volume, shape, and dimensions, which is used to measure the performance of the DUT [SOURCE: IEC 63086-1:2020, 3.6]
3.2.7 target pollutant
specific air pollutant with defined components, including three main categories: particulate matter, gaseous pollutants, and microorganisms [SOURCE: IEC 63086-1:2020, 3.7]
3.2.8 operation decay rate
reduction rate of the target pollutant in the test chamber, due to operation of the DUT −1 Note 1 to entry: Units are per hour (h ).
[SOURCE: IEC 63086-1:2020, 3.8]
3.2.9 CADR
clean air delivery rate flow rate of clean air (with respect to the target pollutant) delivered by the DUT calculated as the product of the measured operation decay rate and the associated test chamber volume 3 −1 Note 1 to entry: The unit is cubic metres per hour (m h ).
[SOURCE: IEC 63086-1:2020, 3.9]
3.2.10 automatic operation mode
setting of the DUT chosen by the user in which the performance is regulated by the air cleaner without further user interaction [SOURCE: IEC 63086-1:2020, 3.10]
oSIST prEN IEC 63086-2-2:2025
3.2.11 manual operation mode
setting of the DUT, chosen by the user, that is not influenced by further external operator interaction, air quality sensor data, and/or timers throughout the duration of the test [SOURCE: IEC 63086-1:2020, 3.11]
3.2.12 maximum performance operation mode
manual operation mode where the DUT is set to the highest flow rate with all air cleaning functions switched on and set to maximum, where applicable Note 1 to entry: If the DUT has zero flow rate, the CADR is measured with all air cleaning functions switched on Note 2 to entry: "All air cleaning functions switched on" implies that the requirements for testing are that all available filters, either for particle and gas filtration, or a combination of both, are inserted in the DUT for each type of test described in the applicable parts of IEC 63086-2.
3.2.13 energy efficiency in maximum performance operation mode
volume of cleaned air provided by consumption of a certain amount of energy calculated by dividing the CADR of the DUT by the electrical power input 3 −1 −1 Note 1 to entry: The unit is cubic metres per watt hour (m W h ).
3.3 Abbreviated terms
CADR clean air delivery rate DNPH 2,4- dinitrophenylhidorazine DUT device under test FID flame ionization detector GC gas chromatography HPLC high performance liquid chromatography IC ion chromatography MS mass spectrometry PTFE polytetrafluoroethylene SIFT-MS selected ion flow tube mass spectrometry TVOC total volatile organic compounds
4 Test gases and initial concentrations for testing
4.1 General
gas-phase pollutants are mainly classified into 6 groups as a) aldehydes, b) aromatic hydrocarbons, c) aliphatic hydrocarbons, d) cyclic terpenes, e) inorganic odorant gases and f) inorganic combustion gases. The test gases representing each group are described in Table 1 in accordance with factors considered comprehensively such as commonly observed as indoor pollutants, suitability for standard test methods in terms of availability, stability, and relatively low toxicity, and typical chemical substances of the group.
The CADR of an air cleaner generally depends on the test gases, and individual representative test gases differ in appropriate initial concentration, generation method, and measurement method of concentration. It is not mandatory to perform tests with all representative test gases, but individual ones relevant for the specific application may be chosen. Also, other test gases which are not described as representative test gases may be chosen for example see Annex A.
The initial concentration of the test gases shall be determined within the range described in each clause in accordance with the purpose of the test and the accuracy of the measuring instrument.
oSIST prEN IEC 63086-2-2:2025
Multiple test gases may be dosed at the same time for parallel measurement of the CADR if they do not react with each other or modify the performance of the technology tested regarding the pollutant(s) tested (ex: lead to competitive adsorption). If gases that can react with each other or if a gas can modify the performance of the technology regarding the gas tested after are used in two consecutive tests, the filter of the DUT shall be changed between the measurements if it is replaceable. Otherwise, the DUT shall be operated in the test chamber while the test chamber air treatment unit is running until the background concentration is below the values described in 8.2.3.
Table 1 – Representative test gases Group of gas-phase pollutants Representative test gas a) Aldehydes Formaldehyde b) Aromatic hydrocarbons Toluene c) Aliphatic hydrocarbons n-Heptane d) Cyclic terpenes d-Limonene e) Inorganic odorant gases Ammonia f) Inorganic combustion gases Nitrogen dioxide NOTE 1 Technical methods such as adsorption (physical or chemical) and decomposition (oxidation and so on) are used for removal of gas-phase pollutants. gas-phase pollutants have different physical and chemical properties, for example, polar or nonpolar, acidic or basic, vapor pressure, resistance to decomposition by oxidative substances, and so on. air cleaner performance for removal of each target gas-phase pollutants differs by the combination of substance and technical method of removal. The performance for removal of one kind of gas -phase pollutants shall not be applied to the other gas-phase pollutant. Therefore, it is important that certification and appeal and explanation to consumers is based on the performance for multiple gas-phase pollutants in accordance with purposes.
NOTE 2 For example, toluene, n-hexane and d-limonene can be tested in parallel, but formaldehyde shall not be tested along with ammonia as they may react with each other.
NOTE 3 Testing individual test gases. The laboratory may select to test each gas individually. If this method is chosen, the laboratory should choose a test sequence that avoid changing the performance of the technology tested from one test to another. An example of sequence that can be applied for adsorption technology is: (cleaning) → Toluene → (cleaning) → d-Limonene → (cleaning) → n-Heptane → (cleaning) → Ammonia → (cleaning) → Formaldehyde → (cleaning) → Nitrogen dioxide → (cleaning). Testing in combination. If the laboratory has the measurement instruments that are capable of measuring and delineating quantities of Toluene, d -Limonene, and n- Heptane from each other, the laboratory may elect to test these three chemicals at the same time. In this case an example of sequence for adsorption technology would be:(cleaning) → [combination of Toluene, d-Limonene and n- Heptane] → (cleaning) → Ammonia → (cleaning) → Formaldehyde → (cleaning) → Nitrogen dioxide → (cleaning). NOTE 4 The information of optional gases such as acetaldehyde and so on is described in Annex A.
4.2 Representative test gases
4.2.1 Formaldehyde
Use commercial gas mixed with nitrogen (N ) for gas cylinder method, an aquous solution of
formaldehyde (formalin, CAS 50-00-0, methanol free) or solid paraformaldehyde (CAS 30525- 89-4) for temperature-controlled vaporization method. initial concentration of formaldehyde is −3 400 µg m (+20%)
4.2.2 Toluene
Use commercial gas mixed with nitrogen (N ) for gas cylinder method, or liquid-phase toluene
(CAS 108-88-3) with at least 99,9 % GC grade purity for temperature-controlled vaporization −3 method. initial concentration of toluene is 800 µg m (+20 %) 4.2.3 n-Heptane Use commercial gas mixed with nitrogen (N ) for gas cylinder method, or liquid-phase n-
heptane (CAS 142-82-5) with at least 99,0 % GC grade purity for temperature-controlled −3 vaporization method. initial concentration of n-heptane is 800 µg m (+20 %).
oSIST prEN IEC 63086-2-2:2025
4.2.4 d-Limonene Use commercial gas mixed with nitrogen (N ) for gas cylinder method, or liquid-phase d-
limonene (CAS 5989-27-5) with at least 95 % purify for temperature-controlled vaporization −3 method. initial concentration of d-limonene is 800 µg m (+20 %)
4.2.5 Ammonia
Use commercial gas mixed with nitrogen (N ) for gas cylinder method, or aqueous ammonia
solution for temperature-controlled vaporization method. initial concentration of ammonia is −3 700 µg m (+20 %).
NOTE It should be recognized that the odour may still be present although the concentration of odorants such as ammonia is reduced.
4.2.6 Nitrogen dioxide
Use commercial gas mixed with nitrogen (N ) for gas cylinder method. initial concentration of
−3 nitrogen dioxide is 500 µg m (+20 %).
The presence of and concentration of nitric oxide and nitrogen dioxide are inextricably linked. Therefore, the concentration of both nitric oxide and nitrogen dioxide throughout the test should be monitored and reported as the concentration and CADR for both gases where found. The natural decay rate and total decay rate tests shall be conducted with nitrogen dioxide exclusively in the chamber.
5 Measurement method for test gas concentration
5.1 General
The measurement method for each substance is specified as follows. In case that it is confirmed that an alternative method has same or higher accuracy than the specified method, it may be used. The information of alternative methods is described in Annex A. Maintenance of all measurements instruments shall be done as defined by the manufacturer´s instructions. Calibration of the instruments with gas standards shall be regularly performed in accordance with the standard operating procedures of the laboratory.
5.2 Measurement and analysis method for formaldehyde
According to ISO 16000-3, silica gel coated with 2,4-dinitrophenylhidorazine (DNPH 3.3) cartridges and High Performance Liquid Chromatography (HPLC 3.3) shall be used for the measurement and analysis of formaldehyde. In tests where there is a possibility that oxidative substances such as ozone are generated, the ozone scrubber described in 5.2 of ISO16000-3 shall be installed in front of the DNPH 3.3 cartridge.
5.3 Measurement and analysis method for toluene, n-heptane, and d-limonene
According to ISO 16000-6, thermal desorption tubes and either Gas Chromatography / Mass Spectrometry (GC/MS 3.3) or Gas Chromatography / Flame Ionization Detector (GC/FID 3.3) shall be used for the measurement and analysis of toluene, n-heptane and d-limonene. Selected Ion Flow Tube Mass Spectrometry (SIFT-MS 3.3) may be used instead of GC/MS 3.3or GC/FID 3.3.
5.4 Measurement and analysis method for ammonia
Distilled water and Ion Chromatography (IC 3.3) or Chemiluminescence analyser shall be used for the measurement and analysis of ammonia.
5.5 Measurement and analysis method for nitrogen dioxide
Chemiluminescence analyser shall be used for the measurement and analysis of nitrogen dioxide.
oSIST prEN IEC 63086-2-2:2025
6 Generation of initial gas concentrations
6.1 General
Each test gases is supplied into the test chamber by the gas cylinder method or the temperature-controlled vaporization method and adjusted to the initial concentration shown in 4.2.
6.1.1 Gas cylinder method
The test gases in the cylinder, which has been adjusted to a predetermined concentration in advance by nitrogen balance, is supplied into the test chamber through an appropriate regulator and polytetrafluoroethylene (PTFE 3.3) or stainless-steel tube.
6.1.2 Temperature-controlled vaporization method
The high-purity reagent of the test gases in the permeation tube, the diffusion tube or the other injection system is temperature-controlled and vaporized, and filtered air or nitrogen gas is used as a carrier gas to supply the test gases into the test chamber.
7 Test chamber
The test chamber is in accordance with 5.6 of IEC 63086-1 except for the following changes:
3 −1 The wall-mounted recirculation fan shall have a flow rate of between 300 − 500 m h and a −1 maximum airspeed of 15 m s measured at the centre of the fan exhaust at 0.5 m from the face.
8 Measurement of the CADR in maximum performance operation mode
8.1 General
Perform the test procedure prescribed in 8.2 (natural decay rate) and 8.3 (total decay rate) to determine the CADR of the DUT.
8.2 Natural decay test
8.2.1 General
natural decay rate shall be carried out without placement of the DUT to keep it away the influence of the contamination by the gas-phase pollutants.
It is permissible to apply the results of the natural decay rate within one week instead of results of a new test.
...