EN 62035:2014/A1:2019
(Amendment)Discharge lamps (excluding fluorescent lamps) - Safety specifications
Discharge lamps (excluding fluorescent lamps) - Safety specifications
2019-02-26 PC: BT approved the European elements, standard can be published
2019-01-22SW: Waiting for BT document to approve annex ZZ.
2019-01-18; GEM: EY quality review confirmation to consider as 'compliant'
2018-09-26: PEC: LVD assessment 'compliant', can be cited for LVD
2018-07-13 - GEM: [assessment received:2018-07-13] [ref:CLCTC34_61527_PUB_M511_20180601_AR] [outcome:inconclusive] - CCMC/TC to advise how to adress this
2018-04-27: Annex zz recieved - waiting for consultant assessment - shall go to BT
2017-04-26 OD: Publication pending, missing annexZ and missing consultant assessment
Entladungslampen (ausgenommen Leuchtstofflampen) - Sicherheitsanforderungen
Lampes à décharge (à l'exclusion des lampes à fluorescence) - Prescriptions de sécurité
Razelektrilne sijalke (razen fluorescenčnih sijalk) - Varnostne specifikacije - Dopolnilo A1 (IEC 62035:2014/A1:2016)
General Information
- Status
- Published
- Publication Date
- 15-Aug-2019
- Withdrawal Date
- 15-Aug-2022
- Technical Committee
- CLC/TC 34 - 'Lamps and related equipment
- Drafting Committee
- IEC/SC 34A - IEC_SC_34A
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 16-Aug-2019
- Completion Date
- 16-Aug-2019
Relations
- Effective Date
- 03-Nov-2015
Overview
EN 62035:2014/A1:2019 is the CENELEC adoption of IEC 62035:2014/A1:2016 and provides safety specifications for discharge lamps (excluding fluorescent lamps). This amendment updates the 2014 base standard with clarified requirements for insulation, creepage and clearance, electrical strength, batch testing and certification support. It is intended to support compliance with the EU Low Voltage Directive (2014/35/EU) via the informative Annex ZZ.
Key topics and technical requirements
- Scope: Safety requirements cover discharge lamps other than fluorescent types; national adoptions (e.g., SIST EN 62035:2015/A1:2019) are aligned with the amendment.
- Creepage and clearance: New provisions specify minimum creepage distances tied to cap types. Lamps with cap codes such as GX8.5, GX10, GU8.5, PGZ12, PGZX18 reference relevant maximum voltages and pulse voltages (e.g., 305 V and 5 kV pulse; 5.9 kV pulse for PGZX18). For PGZ12 and GX8.5, a minimum creepage/clearance of 6.5 mm applies.
- Insulation resistance: Measured at 500 V d.c.; minimum values updated to 4 MΩ for caps listed in the amendment’s table and 2 MΩ for other caps.
- Dielectric (electric strength) test: Specified a.c. test voltages of 3 000 V for caps in Table 7 and 1 500 V for others, applied for 1 minute; test procedure requires initial application at half voltage then rapid increase to full value.
- Cap and luminaire interaction: Metal parts of lamps not connected to live parts (e.g., metal cap shells) must have reinforced or double insulation; guidance is included for use in Class II luminaires where additional insulation may be required.
- Environmental protection: Lamps should be protected from direct water contact when used in luminaires rated IPX1 or higher.
- Quality, batch testing and certification: Amendment refines batch sampling, whole-production assessment and adds Annex K with requirements for manufacturer records, sampling plans and acceptable quality levels (AQL) for certification.
Applications and who uses it
- Lamp manufacturers - design, testing and CE marking of discharge lamps to meet safety requirements.
- Luminaire designers and OEMs - ensure compatibility and safe installation, especially when using lamps with metal cap shells or in Class II luminaires.
- Test laboratories and certification bodies - perform insulation, dielectric and batch tests; apply Annex K for certification assessments.
- Regulatory and compliance teams - use Annex ZZ mapping to the Low Voltage Directive for conformity assessment and market surveillance.
Related standards and references
- IEC 62035:2014/A1:2016 (base international text)
- IEC 60598-1:2014 (Luminaires - Part 1: General requirements and tests) - added as a normative reference in the amendment
- EU Low Voltage Directive 2014/35/EU - relationship explained in Annex ZZ
Keywords: EN 62035, IEC 62035 amendment, discharge lamps safety, creepage distance, insulation resistance, dielectric strength, Low Voltage Directive, lamp certification.
Frequently Asked Questions
EN 62035:2014/A1:2019 is a amendment published by CLC. Its full title is "Discharge lamps (excluding fluorescent lamps) - Safety specifications". This standard covers: 2019-02-26 PC: BT approved the European elements, standard can be published 2019-01-22SW: Waiting for BT document to approve annex ZZ. 2019-01-18; GEM: EY quality review confirmation to consider as 'compliant' 2018-09-26: PEC: LVD assessment 'compliant', can be cited for LVD 2018-07-13 - GEM: [assessment received:2018-07-13] [ref:CLCTC34_61527_PUB_M511_20180601_AR] [outcome:inconclusive] - CCMC/TC to advise how to adress this 2018-04-27: Annex zz recieved - waiting for consultant assessment - shall go to BT 2017-04-26 OD: Publication pending, missing annexZ and missing consultant assessment
2019-02-26 PC: BT approved the European elements, standard can be published 2019-01-22SW: Waiting for BT document to approve annex ZZ. 2019-01-18; GEM: EY quality review confirmation to consider as 'compliant' 2018-09-26: PEC: LVD assessment 'compliant', can be cited for LVD 2018-07-13 - GEM: [assessment received:2018-07-13] [ref:CLCTC34_61527_PUB_M511_20180601_AR] [outcome:inconclusive] - CCMC/TC to advise how to adress this 2018-04-27: Annex zz recieved - waiting for consultant assessment - shall go to BT 2017-04-26 OD: Publication pending, missing annexZ and missing consultant assessment
EN 62035:2014/A1:2019 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 62035:2014/A1:2019 has the following relationships with other standards: It is inter standard links to EN 62035:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 62035:2014/A1:2019 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 62035:2014/A1:2019 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2019
Razelektrilne sijalke (razen fluorescenčnih sijalk) - Varnostne specifikacije -
Dopolnilo A1 (IEC 62035:2014/A1:2016)
Discharge lamps (excluding fluorescent lamps) - Safety specifications (IEC
62035:2014/A1:2016)
Entladungslampen (ausgenommen Leuchtstofflampen) - Sicherheitsanforderungen (IEC
62035:2014/A1:2016)
Lampes à décharge (à l'exclusion des lampes à fluorescence) - Prescriptions de sécurité
(IEC 62035:2014/A1:2016)
Ta slovenski standard je istoveten z: EN 62035:2014/A1:2019
ICS:
29.140.30 Fluorescenčne sijalke. Sijalke Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 62035:2014/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2019
ICS 29.140.30
English Version
Discharge lamps (excluding fluorescent lamps) - Safety
specifications
(IEC 62035:2014/A1:2016)
Lampes à décharge (à l'exclusion des lampes à Entladungslampen (ausgenommen Leuchtstofflampen) -
fluorescence) - Prescriptions de sécurité Sicherheitsanforderungen
(IEC 62035:2014/A1:2016) (IEC 62035:2014/A1:2016)
This amendment A1 modifies the European Standard EN 62035:2014; it was approved by CENELEC on 2016-12-29. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 62035:2014/A1:2019 E
European foreword
The text of document 34A/1873/CDV, future IEC 62035:2014/A1, prepared by SC 34A "Lamps" of
IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 62035:2014/A1:2019.
The following dates are fixed:
• latest date by which the document has to be (dop) 2020-02-16
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2022-08-16
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this
document.
Endorsement notice
The text of the International Standard IEC 62035:2014/A1:2016 was approved by CENELEC as a
European Standard without any modification.
In the Bibliography of EN 62035:2014, the following note has to be deleted for the standard indicated:
IEC 60598-1 NOTE Harmonized as EN 60598-1.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Addition to the Annex ZA of EN 62035:2014:
Publication Year Title EN/HD Year
IEC 60598-1 (mod) 2014 Luminaires -- Part 1: General requirements EN 60598-1 2015
and tests
Annex ZZ
(informative)
Relationship between this European standard and the safety objectives of
Directive 2014/35/EU [2014 OJ L96] aimed to be covered
This European Standard has been prepared under a Commission’s standardization request relating to
harmonized standards in the field of the Low Voltage Directive, M/511, to provide one voluntary means
of conforming to safety objectives of Directive 2014/35/EU of the European Parliament and of the
Council of 26 February 2014 on the harmonization of the laws of the Member States relating to the
making available on the market of electrical equipment designed for use within certain voltage limits
[2014 OJ L96].
Once this standard is cited in the Official Journal of the European Union under that Directive,
compliance with the normative clauses of this standard given in Table ZZ.1 confers, within the limits of
the scope of this standard, a presumption of conformity with the corresponding safety objectives of
that Directive, and associated EFTA regulations.
Table ZZ.1 – Correspondence between this European standard and Annex I of Directive
2014/35/EU [2014 OJ L96]
Clause(s) / sub-clause(s)
Safety objectives of Directive
Remarks / Notes
2014/35/EU
of this EN
1. General conditions
a) the essential characteristics, 4.2, 4.6.1.2, 4.6.2.2 and 5.2.2
the recognition and observance
of which will ensure that
electrical equipment will be used
safely and in applications for
which it was made, shall be
marked on the electrical
equipment, or, if this is not
possible, on an accompanying
document;
b) the electrical equipment, 4.3.1 and 4.3.2
together with its component
parts, shall be made in such a
way as to ensure that it can be
safely and properly assembled
and connected;
c) the electrical equipment shall See item 2 and 3 of this table
be so designed and
manufactured as to ensure that
protection against the hazards
set out in points 2 and 3 is
assured, providing that the
equipment is used in
applications for which it was
made and is adequately
maintained.
2. Protection against hazards
arising from the electrical
equipment
Measures of a technical nature
shall be laid down in
accordance with point 1, in
order to ensure that:
a) persons and domestic 4.4 and 4.5.
animals are adequately
protected against the danger of
physical injury or other harm
which might be caused by direct
or indirect contact;
Photobiological requirements;
b) temperatures, arcs or 4.6
EMF is not covered
radiation which would cause a
danger, are not produced;
c) persons, domestic animals 5
and property are adequately
protected against non-electrical
dangers caused by the electrical
equipment which are revealed
by experience;
d) the insulation is suitable for 4.4
foreseeable conditions.
3. Protection against hazards
which may be caused by
external influences on the
electrical equipment
Technical measures shall be
laid down in accordance with
point 1, in order to ensure that
the electrical equipment:
a) meets the expected 4.3
mechanical requirements in
such a way that persons,
domestic animals and property
are not endangered;
b) is resistant to non-mechanical 4.5
influences in expected
environmental conditions, in
such a way that persons,
domestic animals and property
are not endangered;
c) does not endanger persons, 4.5
domestic animals and property
in foreseeable conditions of
overload.
WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the product(s) falling within the scope of
this standard.
IEC 62035 ®
Edition 2.0 2016-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
A MENDMENT 1
AM ENDEMENT 1
Discharge lamps (excluding fluorescent lamps) – Safety specifications
Lampes à décharge (à l'exclusion des lampes à fluorescence) – Prescriptions de
sécurité
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.30 ISBN 978-2-8322-3774-8
– 2 – IEC 62035:2014/AMD1:2016
© IEC 2016
FOREWORD
This amendment has been prepared by subcommittee 34A: Lamps, of IEC technical
committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
CDV Report on voting
34A/1873/CDV 34A/1909/RVC
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC website under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
2 Normatives references
Add the following new reference:
IEC 60598-1:2014, Luminaires – Part 1: General requirements and tests
4.3.1.2 Creepage distance
Replace the existing text with the following new text including new Table 7:
The minimum creepage distance between contact pin(s) or contacts and a touchable metal
shell of the cap shall be in accordance with the requirements of IEC 60061-4 sheet
number 7007-6.
Metal parts of the lamp which are not connected to current carrying parts (for example a metal
cap shell) and which may be accessible in normal use or during lamp replacement, shall be
insulated from live parts by double or reinforced insulation. In these cases the minimum
creepage distance between live parts and a touchable metal part of the lamp or cap shall be
in accordance with the reinforced insulation requirements of IEC 60598-1:2014, Section 11.
Lamps with caps listed in Table 7 shall comply with these requirements.
IEC 62035:2014/AMD1:2016 – 3 –
© IEC 2016
Table 7 – Voltage to be considered for creepage and clearance
Cap Relevant maximum voltage according to Relevant maximum voltage according to
code IEC 60598-1:2014, Table 11.1 IEC 60598-1:2014, Table 11.2
GX8.5 305 V 5 kV pulse
GX10 305 V 5 kV pulse
GU8.5 305 V 5 kV pulse
PGZ12 305 V 5 kV pulse
a
PGZX18 305 V 5,9 kV pulse
a
5,9 kV is the equivalent peak voltage based on HF ignition currently used for this system.
For caps PGZ12 and GX8.5, minimum creepage distances and clearances of 6,5 mm apply.
NOTE See IEC 60061-4, sheet 7007-6 for information.
Compliance is checked by measurement.
4.4.2 Insulation resistance
Replace the existing text with the following new text:
Lamps where metal parts which are not connected to current carrying parts (for example a
metal cap shell) can be touched after insertion into the holder shall have an insulation
resistance between the metal parts and the pin(s) or contacts of not less than 4 MΩ for lamps
with a cap listed in Table 7 and 2 MΩ for all others
Compliance is checked by measurement with suitable test equipment using a d.c. voltage of
500 V.
4.4.3 Electric strength
Replace the existing text with the following new text:
The insulation between the same parts as those referred to in 4.4.2 shall have sufficient
dielectric strength.
For lamps with a cap listed in Table 7 compliance is checked with a 3 000 V a.c. vo
...
この記事は、欧州規格EN 62035:2014/A1:2019の承認プロセスについて取り上げています。この規格は蛍光灯を除く放電灯に関する安全仕様を扱っています。規格の発行はBTによって承認されましたが、まだZZ添付文書の承認を待っています。さらに、EYの品質レビューにより、この規格が準拠しているとの確認を受けました。LVDへの準拠評価など、他の評価も行われましたが、解決していない問題がまだいくつかあります。これには、2018年7月に受け取った評価の結果が明確でないことや、コンサルタントの評価とZZ添付文書が必要なことなどが含まれます。全体的には、この規格の発行はまだ保留中です。
이 기사는 유럽 표준인 EN 62035:2014/A1:2019에 대한 승인 프로세스에 대해 다루고 있습니다. 이 표준은 형광등을 제외한 방전등에 대한 안전 사양을 다루고 있습니다. 표준의 게시는 BT에 의해 승인되었지만, 아직 ZZ 부록을 승인하기 위한 문서가 대기 중입니다. 또한 EY의 품질 검토에서 이 표준이 준수되었다는 확인을 받았습니다. LVD 준수를 위한 평가 등 다른 평가가 진행되었지만, 미해결된 문제점이 여전히 있습니다. 이는 2018년 7월에 수신된 평가에서는 분명한 결론을 얻지 못했으며, 컨설턴트 평가와 ZZ 부록이 필요하다는 점입니다. 전반적으로, 이 표준의 게시는 아직 보류 상태입니다.
The article discusses the approval process for the European standard EN 62035:2014/A1:2019, which pertains to safety specifications for discharge lamps (excluding fluorescent lamps). The publication of the standard was approved by BT, but there is still a document awaiting approval for annex ZZ. Additionally, an EY quality review confirmed that the standard is compliant. Other assessments have been conducted, such as an assessment for LVD compliance, but there are still some outstanding issues to address. These include an inconclusive outcome from an assessment received in July 2018, and the need for a consultant assessment and annex ZZ. Overall, the publication of the standard is still pending.










Questions, Comments and Discussion